arxiv:submit/ [math.gm] 27 Mar 2018

Similar documents
State of Health Estimation for Lithium Ion Batteries NSERC Report for the UBC/JTT Engage Project

This short paper describes a novel approach to determine the state of health of a LiFP (LiFePO 4

An Impedance-Based BMS to Identify Bad Cells Rengaswamy Srini Srinivasan Bliss G. Carkhuff

Novel Charging Protocols in Lithium Ion Battery

Analytical thermal model for characterizing a Li-ion battery cell

Battery Pack Design. Mechanical and electrical layout, Thermal modeling, Battery management. Avo Reinap, IEA/LU

Study on the Performance of Lithium-Ion Batteries at Different Temperatures Shanshan Guo1,a*,Yun Liu1,b and Lin Li2,c 1

GeePower Energy Technology Co., Limited

Dr. Pierrot S. Attidekou RA Newcastle University

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

PERFORMANCE CHARACTERIZATION OF NICD BATTERY BY ARBIN BT2000 ANALYZER IN BATAN

Comparative Analysis of Features for Determining State of Health in Lithium-Ion Batteries

Capacity fade analysis of a battery/super capacitor hybrid and a battery under pulse loads full cell studies

Modeling and thermal simulation of a PHEV battery module with cylindrical LFP cells

New energy for the future

Specification Approval Sheet

Modeling the Lithium-Ion Battery

EE152 Green Electronics

Programming of different charge methods with the BaSyTec Battery Test System

Battery Response Analyzer using a high current DC-DC converter as an electronic load F. Ibañez, J.M. Echeverria, J. Vadillo, F.Martín and L.

WORKSHOP ON BATTERY TESTING

CALL FOR A QUOTE (877)

Exploring Electric Vehicle Battery Charging Efficiency

Performance optimization of a battery capacitor hybrid system

UN Transportation Tests and UL Lithium Battery Program

BATTERIES & SUPERCAPS POST MORTEM ANALYSIS PLATFORM EXTERNAL SERVICES

Hybrid Electric Vehicle End-of-Life Testing On Honda Insights, Honda Gen I Civics and Toyota Gen I Priuses

Standby Battery Life Management: Breaking the Price Barrier

Stefan van Sterkenburg Stefan.van.sterken

Online Estimation of Lithium Ion Battery SOC and Capacity with Multiscale Filtering Technique for EVs/HEVs

Mini Project. Classification of 2 Lithium Iron Phosphate Batteries to increase state of charge estimation accuracy.

Towards advanced BMS algorithms development for (P)HEV and EV by use of a physics-based model of Li-ion battery systems

Improvements to the Hybrid2 Battery Model

DC Electronic Loads simulate NTC devices for temperature monitoring in battery test applications

Accelerated Testing of Advanced Battery Technologies in PHEV Applications

Model Comparison with Experiments. 341 N. Science Park Road State College, PA U.S.A.

NaS (sodium sulfura) battery modelling

80V 300Ah Lithium-ion Battery Pack Data Sheet

Energy Storage. 9. Power Converter Demo. Assoc. prof. Hrvoje Pandžić. Vedran Bobanac, PhD

Testing Lead-acid fire panel batteries

Chapter 1: Battery management: State of charge

12V Start-Stop and 48V Mild Hybrid LMO-LTO Batteries

Battery Pack Laboratory Testing Results

Energy Storage (Battery) Systems

Understanding Lithium-Ion Technology Jim McDowall (updated from Battcon 2008)

Modeling Reversible Self-Discharge in Series- Connected Li-ion Battery Cells

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Investigation into partial cycling of lithium-ion cells Report

End-To-End Cell Pack System Solution: Rechargeable Lithium-Ion Battery

Improved Functional Safety with Advanced Real Time Embedded Battery Diagnostics

INTERNATIONAL STANDARD

Common Mistakes in Battery Pack Development (And how to avoid them) By Katherine Mack, Rose Electronics

THINERGY MEC220. Solid-State, Flexible, Rechargeable Thin-Film Micro-Energy Cell

ETX Lithium Battery User s Manual

Presented at the 2012 Aerospace Space Power Workshop Manhattan Beach, CA April 16-20, 2012

USABC Development of 12 Volt Energy Storage Requirements for Start-Stop Application

SOH Estimation of LMO/NMC-based Electric Vehicle Lithium-Ion Batteries Using the Incremental Capacity Analysis Technique

SB LiMotive Automotive Battery Technology. Kiho Kim

Optimizing Battery Accuracy for EVs and HEVs

SimpliPhi Power PHI Battery

Use of EV battery storage for transmission grid application

I. Equivalent Circuit Models Lecture 3: Electrochemical Energy Storage

Midterm Event. Holger Czuday, Bayern Innovativ 7th February Automotive Battery Recycling and 2nd Life

VARIABLE DISPLACEMENT OIL PUMP IMPROVES TRACKED VEHICLE TRANSMISSION EFFICIENCY

Lithium battery charging

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Aalborg Universitet. Published in: ECS Transactions. DOI (link to publication from Publisher): / ecst. Publication date: 2015

6.UAP Thesis Proposal: Design of an Inductively-Coupled. AUV Recharging System

Datasheet-based modeling of Li-Ion batteries Barreras, Jorge Varela; Schaltz, Erik; Andreasen, Søren Juhl; Minko, Tomasz

Lithium Ion Medium Power Battery Design

Phosphate-base Lithium-ion Battery Pack Model:LFP V 1350Ah Product Specifications Lithium Energy Solution 1/8

Power Management Solution: Constant Voltage (CV) Pulse Charging of Hybrid Capacitors

Modeling of Battery Systems and Installations for Automotive Applications

Development of a Smart High-power Battery for CubeSats

Battery durability. Accelerated ageing test method

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Topic 5 Lecture 3 Estimating Policy Effects via the Simple Linear. Regression Model (SLRM) and the Ordinary Least Squares (OLS) Method

12-Batteries and Inverters. ECEGR 452 Renewable Energy Systems

PSIM Tutorial. How to Use Lithium-Ion Battery Model

Conductive Polymer Aluminum Capacitors SMD (Chip), Low Impedance

Specification. Cylindrical Li-ion battery. Type: Product model battery VER A Product Specification 3. 6 V 2600 mah

Lab 3 : Electric Potentials

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

Battery Evaluation for Plug-In Hybrid Electric Vehicles

BOOST POWER 1212 Product Description

LITHIUM BATTERY AND ULTRA-CAPACITOR AGING

Lithium-ion Battery DATA SHEET

APPLICATION NOTE

INSTALLATION INFORMATION

Aging and Characterization of Li-Ion Batteries in a HEV Application for Lifetime Estimation

AEG Belgium customer day Telecom products & systems

Impact of Vehicle-to-Grid (V2G) on Battery Life

A Battery Smart Sensor and Its SOC Estimation Function for Assembled Lithium-Ion Batteries

Turbo-charging Your Forklift Fleet: The Power of Industrial Lithium Forklift Batteries

Lithium-ion Battery DATA SHEET

DYNAMIC BOOST TM 1 BATTERY CHARGING A New System That Delivers Both Fast Charging & Minimal Risk of Overcharge

Rechargeable Lithium Ion Battery Model : ICR18650 A2

TUTORIAL Lithium Ion Battery Model

Transcription:

arxiv:submit/2209270 [math.gm] 27 Mar 2018 State of Health Estimation for Lithium Ion Batteries NSERC Report for the UBC/JTT Engage Project Arman Bonakapour Wei Dong James Garry Bhushan Gopaluni XiangRong Kong Alex Pui Daniel Wang Brian Wetton 1 Overview March 27, 2018 JTT Electronics (JTT) is a Vancouver-based firm that develops Lithium Ion battery packs, optimized for different applications that include electric vehicles, electric scooters, and back-up power systems of several scales. A key aspect of their technology is their proprietary Battery Management Systems (BMS), that monitor the battery pack to maintain safe operation during charging and use, and allow some performance optimization. Such systems have a component that estimates the pack State of Charge (SoC), that is the amount of charge still in the pack to deliver application power. The simplest SoC indicators rely on an invariant model of the cell s performance to yield their output and do not take into account how a pack is changing over time. The performance of batteries decreases over time and with use, described as a change in the battery s State of Health (SoH). All commercially available BMS devices that we are aware of do not currently monitor SoH. Some aspects of SoH are easy to determine (total charge capacity of a cell can be determined through a discharge and full charge cycle if the application permits this) but others are not. Ideally, SoH would be determined by a BMS without recording and analyzing extensive use history. Knowing the characteristics of a battery (and when it should be replaced) as it ages and in different conditions is important for many applications (electric vehicles, electric scooters for people with disabilities, remote sensing). Such estimates also allow more optimal operation of larger systems with many packs. A next generation of BMS with SoH estimation capability would be a valuable product for JTT. SoH modelling requires experimental results of battery performance over a long time period. Several months of experimenting has been done in the battery laboratory in the UBC CHBE department, with results shown below. 1

These experiments were done by Arman Bonakapour, a research associate in that department, and XiangRong (David) Kong, the graduate student involved in the project. A novel method to determine SoH was proposed by Daniel Wang, an engineer at JTT, and its possible utility was backed by an analysis of our experimental results. 2 Experimental On the recommendation of James Garry, a consultant at JTT at the beginning of the project, cylindrical 18650 lithium-ion rechargeable cells (Panasonic NCR18650B, Figure 1) of LiCoO 2 chemistry were tested in this work. This is a well-known and commonly used battery, and it has been used in larger packs (the early Tesla battery packs for example). It was felt that using a well-known commercial battery type would make the results of greater interest to the larger scientific community and would avoid the IP issues of using proprietary JTT cells. The nominal cell voltage and capacity of these cells are 3.6V and 3.2Ah, respectively. The manufacturer recommended charge/discharge voltage boundaries are between 2.5 and 4.2V. Figure 1: Panasonics NCR18650B Lithium-ion Batteries So far, we have done 100+ 1C charge and discharge cycles for these cells. As you can see below, this is enough to see some SoH loss (increased DC resistance and loss of capacity). Galvanostatic cycling is performed within the manufacturer specified voltage range of 2.5-4.2V. Electrochemical impedance was measured between 50kHz-10mHz by applying a voltage perturbation of 40mV. The typical protocol for EIS data collection is shown below, with steps 1-10 considered one cycle: 1. Rest 30min under open circuit condition 2. Collect electrochemical impedance spectra (EIS); 50kHz-10mHz at 40mV amplitude 3. Constant current (CC) discharge to 2.5V at 3.2A (1C) 2

4. Rest 30min under open circuit condition 5. Collect (EIS); 50kHz-10mHz at 40mV amplitude 6. CC charge to 4.2V at 3.2A (1C) 7. rest 30min under open circuit condition 8. Collect (EIS); 50kHz-10mHz at 40mV amplitude 9. Constant voltage (CV) charge at 4.2V until I<0.01A 10. Collect (EIS); 50kHz-10mHz at 40mV amplitude Figure 2 shows a typical current and voltage profile of the batteries for one charge/discharge cycle. It can be seen that a cycle is made up of three stages. During constant current discharging, the current is denoted as a negative value and the voltage decreases non-linearly until it reaches the pre-designated cut-off voltage (2.5V). During constant current charging, the current is held constant with a floating voltage until the voltage reaches its designated maximum charging voltage (4.2V), at which point constant voltage charging begins. When the battery is held at a constant voltage, its current decreases until it reaches a very low cut-off value. Figure 2: Discharge/Charge Current and Voltage Profile Throughout all cycles, the anode and body temperature of the battery cells are measured and recorded by attaching thermocouples and then insulated with tape. This generates a temperature profile for the chosen current rate (1C). All five treatments include electrochemical impedance spectroscopy (EIS) conducted under room temperature. EIS data is fitted with appropriate equivalent circuit model shown in Figure 3. This fitting allows the extraction of (high frequency) resistance and capacitance of the battery versus cycle number. The fitting was performed using the EC-Lab software from Bio-logic, with the quality of the fitting indicated by Chi-squared test. 3

Figure 3: Equivalent Circuit Model for EIS Data Fitting 3 Industrially Relevant Results Figure 4 shows the voltage vs. capacity curves for every twenty discharge cycles starting from cycle 2. Discharging curves move to the left as cycle number increases, indicating that the capacity, or the amount of charge the battery is able to hold, decreases as it is cycled. Also shown are the voltage versus capacity for the CC portion of the charging cycles, which show a similar trend. Figure 4: Voltage vs. Capacity Curves Overall charging capacity (CC plus CV) is nearly identical to discharge and shows a similar trend of lower capacity with cycling as shown in Figure 5 (discharge and total charging results overlap on the figure). The figure shows that the CC portion of charging capacity decreases with cycle as predicted by the results shown in Figure 4 (right). However, CV charging capacity increases with cycle number and the lower figure shows a magnified version of the trend, which looks initially linear but appears to be saturating. The most likely explanation for the trend is that battery internal resistance increases with use, and thus the CC cycle ends earlier. SoH Measuring Strategy It is clear from the literature and our experimental results that total battery capacity decreases with use. However, the only way this can be put to use to measure SoH is to fully charge then discharge (or vice-versa) the battery in 4

controlled conditions. This would be time consuming and could waste power. However, whatever the battery usage was, the CV charging cycle begins in a reproducible way. If the CV charge can be run to completion (in an evening off duty cycle period, for example) the CV capacity can identify the cycle number in our tests (see Figure 5, lower graph). We consider 1C cycle number as a proxy for general SoH but this requires further experimental work as described in Section 5 below. Figure 5: Capacity Versus Cycle 4 Other Results Figure 6 shows the battery temperature vs. time for every six cycles starting from cycle 1, with the left graph the anode temperature and the right graph the body temperature. Notice the peaks of the anode temperature is in general about 2 degrees Celsius higher than that of the body temperature. These need to be processed to remove ambient temperature trends. After that, we may be able to observe trends in these profiles with cycle number. Figure 7 shows a typical EIS curve in blue, along with its equivalent circuit model fit in red. The dual semi-circles inform resistance and capacitance of the battery, and the rising tail informs the Wahlberg unit which represents the resistance due to electrochemical mass transfer of ions inside the battery. Figure 8 shows the all EIS measurement taken during the 101 cycles. Recall 5

Figure 6: Battery Temperature vs. Cycles Figure 7: Typical EIS data and its Fitting that in each cycle, EIS measurement is taken once before discharging, once after discharging, once after CC charging, and once after CV charging. The left y-axis and the blue data points show the resistance while the right y-axis and the orange data points show the capacitance. All axes are normalized for easy comparison. On the graphs, the total resistance and capacitance of the equivalent circuit in Figure 3 are shown. Figure 7a shows a nearly linear increase in resistance and a slowly increasing capacitance, which is observed in many literature studies as well. Notice that figure 7a and 7d are nearly identical, since no operation is performed after CV charging (7d) and before discharging (7a). What is interesting is Figure 7b and 7c, taken after discharge and after CC charge, respectively. The former shows the highest resistance and capacitance in all four stages while the latter shows the lowest. The EIS profile data show that a charging battery and a discharging battery do not have the same characteristics. While resistance shows an increasing trend in all four stages, it decreases after discharge in Figure 7b. This is 6

Figure 8: Resistance and Capacitance versus Cycles unexpected and requires further investigation. In general, the interpretation of these high frequency impedance curves will take some thought. Note that the resistance here is not the DC resistance observed in the charge and discharge cycles in Figure 4. 5 Planned Experimental Continuation Consider the limited (to 1C charging and discharging cycles) measurements of SoH decay that we have. Consider specifically the discharge curve on the left side of Figure 4. We can consider the voltage V as a function of θ, the cumulative discharge in Ah and γ, the 1C cycle number. Here, we are considering γ as a proxy for age, as a parameter for SoH. We plan to make a fit of V (θ, γ) for 1C discharge in a way that allows extension to other discharge rates. We plan to do lifetime testing for three other operating conditions: 1. 2C cycling 2. No current (shelf life degradation) 3. Thermal cycling with no current. We are getting equipment in place to be able to thermally cycle batteries with external heating to match the thermal cycles in Figure 5. The results would disambiguate SoH loss to 1C cycling versus just the thermal effects of the cycling. This novel experimental work, suggested by James Garry, would make the study publishable. 7

What will be interesting if the SoH loss from these other cases follows the same parametrization of V (θ, γ), although γ will no longer correspond to cycle number. If so, this could also be of relevance to JTT technology: Imagine a BMS running a battery of unknown SoH γ but well characterized as we have done for NCR18650B cells. After charging, the BMS keeps track of discharge θ. As it draws current, it can check the measured voltage against θ. Consider for example 1C current at 1.5Ah discharge on figure 4. From the voltage, the cycle number γ can be inferred. Then, the BMS can predict later performance of the cell, knowing an estimate of its SoH. Of course, we do not know if different conditions affect the SoH in a similar enough way to make this parametrization, but it is an idea we plan to explore. 6 Outcomes Discussions with JTT so far have not led to concrete plans to continue the collaboration. They were potentially interested in participating in a larger battery research consortium that would bring together the several companies in the Vancouver area that are developing or using battery technology. The Engage grant provided experimental equipment for the UBC CHBE battery lab that will see ongoing use in this and other projects. In addition, it provided the graduate student, David Kong, with experience in battery experimental work and data analysis. We would like to thank NSERC for the opportunity to develop our expertise in this area of increasing commercial and scientific interest, working with JTT. 8