Self-Exciting Flameproof Alternator

Similar documents
Flameproof Alternator

Flameproof Alternator

Flameproof Alternator

Flameproof Alternators

SELECTION, APPLICATION AND MAINTENANCE

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

Diesel Engine Shutdown System

Automatic Fuel Shut Down Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Diesel Engine Air Intake Shutoff Valves

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Operating Instructions

Cable Glands - American Series - NEC/IEC

ABG Cable Glands Installation Procedure

System Selection Guide

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

by AMOT World class diesel engine safety solutions Product Selection Guide

Zone 1 Linear Range - Installation Guide

Armoured / Un-armoured Cable Gland

INSTRUCTION MANUAL (ATEX / IECEx)

Pressure and Temperature Switches

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

INSTRUCTION MANUAL (ATEX / IECEx)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

VALIADIS S.A. HELLENIC MOTORS

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Operating Instructions

Diesel Engine Shutdown Valve

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

ADE 6F ADE 6F. page 46

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS SOLAS LED Luminaire ATEX & IECEx

Linear luminaire with LED Series EXLUX 6002

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

The ultimate low voltage temporary LED lighting solution

EXEL-L. Detail of the internal side. Transparent polycarbonate

Ex m Solenoid Operator Type 0519

Amphenol Cable Glands and Cord Grips Amphenol

Linear Luminaire with LED Series EXLUX 6002

CCAI, CCAIF, CCAIF..H

Solenoid coil for control in potentially explosive areas Type BZ

Floodlight Range Installation Guide

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Pneumatic Indicating Relay

Operating Instructions

IECEx Certificate of Conformity

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Floodlight Series 6121

Flameproof Level Sensor (Flameproof F/S FP)

The ultimate low voltage temporary LED lighting solution

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Pan and Tilt Head CDD2416-T

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

A Full Line of Low Voltage IEC Motors In-Stock

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ILED Dorado. User Manual

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

The safety you rely on.

SERIES R - MD MOR & GOR

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

PPT 802, Proximity Probe Transducer System

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

Modular Explosion Proof Brakes. IECLine rev 0

Glass Reinforced Polyester Enclosures

Position Switches Series 8074/2

Thermostatic Control Valve

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Optimise your temperature control

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

HTSB system System overview

INSTALLATION &SAFETY DATA SHEET

3-Way Temperature Control Valve

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

TIMING BELT COMPONENTS EM 15

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

DIAMOND POINT VIBRATING PROBES

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

Explosion and flame-proof single phase electric motors

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

Transcription:

Self-Exciting Flameproof Alternator Model ASX-310 Application l For use use in in hazardous hazardous areas areas classified classified as as Zone 1, For Zone 1, Gas Group IIB, T4 and Dust Group IIIC, T135 Gas Group IIB, T4 and Dust Group IIIC, T135 Suitable l Suitable for for local local ambient ambient temperature temperature range -30 C to +55 C range -30 C to +55 C Designed as a belt driven diesel engine mounted Designed as a belt driven diesel engine l alternator mounted alternator Key benefits l l l l Compact high high performance performance design design Compact Certified for ATEX and IEC Ex T4 rating gives safe performance in T3 areas Will produce power without connection to battery T4 rating gives safe for performance T3 areas Speed signal output overspeedinshutdown Certified gland included Suitable cable for offshore conditions Wide choice of optional pulleys Will produce power without connection to Group 1 mining version available battery Model ASX-310 Self-Exciting Flameproof Alternator l Speed signal output for overspeed shutdown l Certified cable gland included l Wide choice of optional pulleys l Group 1 mining version available www.chalwyn.com

Pulley Back Face Self-Exciting Flameproof Alternator - Model 310 Description Twelve pole rotating field coil type self exciting alternators. To provide a speed signal and sufficient power output to charge a typical small to medium sized diesel engine start battery. Designed as Category 2G/D equipment and marked : CHALWYN by AMOT, UK 0518 SIRA 99ATEX1127X TYPE ASX-310 SERIAL NO. xxxxx Bury St Edmunds, UK T: +44(0)1284 715739 E llb T4 (Tamb = -30 to 5 ) IP 6 II 2 GD TMAX 125 C OUTPUT 28V 25A MAX DO NOT OPEN WHEN EXPLOSIVE ATMOSPHERE IS PRESENT ASX-310 alternators also meet the Electromagnetic Compatibility (EMC) requirements of MIL STD 461E Clauses RE102 and RS103. The outer enclosure of these alternators is manufactured from LM 25 die castings. Fan, fan discs, and pulleys are manufactured from carbon steel. Overall dimensions are as given below. 158.0 Optional Side Entry Gland Position External Earthing Point 118.0 32.5 94 Ø 163 Ø 10.5 210.5 94 193.5 Note: To maintain full compliance with hazardous area and EMC requirements ensure:- a. The external earthing point of the alternator and any armoured/screened cable are properly bonded to the engine/engine frame. b. Any connected electrical equipment is engineered to the requisite standard. page 2

Self-Exciting Flameproof Alternator - Model 310 Application The ASX-310 is designed for application as a belt driven diesel engine mounted alternator for use in hazardous areas classified as Zone1, Group IIB, It is suitable for a local ambient temperature range between -30 C and +5 C. This equipment must not be used for other applications/ambient conditions without the prior approval of Chalwyn. The continu- ous alternator output must not exceed 25 amperes. Important Note: If a significant proportion of the alternator output is used to light incandescent lamps, due allowance must be made for the low cold electrical resistance and hence current surge when the lamps are first lit. When the ASX-310 is used to power the Chalwyn Series 110 engine shut down control system a special circuit external to the ASX-310 is incorporated to limit any such high transient current and hence any lamps powered via the Series 110 may take a few seconds to reach full brightness. If no current limiting circuit is incorporated and the engine started with a significant incandescent lamp load in circuit or, if a significant incandescent lamp load is switched on whilst the engine (alternator) is running at low speed, the ASX-310 may fail to excite or cease to excite until the engine is run up to moderate/high speed. Pulley Selection Note the belt section size and select the appropriate width pulley from the table below. Take into account alternator speed range (see Installation paragraph 2) when selecting the most suitable diameter of a pulley. For latest details of the range of suitable pulleys please contact your Chalwyn distributor. Note, if a non Chalwyn pulley is to be fitted please forward design details to your Chalwyn distributor for approvals. When fitting a pulley use a 8mm hexagonal Allen drive in the rotor hole and tighten the nut supplied to 60 NM (44 lb feet) torque. General Form Belt Width Drive Diameter (mm) Pulley SPA (Small) 1/2 / 13mm 55 ASX-546 SPA (Medium) 1/2 / 13mm 71 ASX-549 SPA (Large) 1/2 / 13mm 80 ASX-574 SPB (Small) 5/8 / 16mm 66 ASX-539 SPB (Medium) 5/8 / 16mm 71 ASX-548 SPB (Large) 5/8 / 16mm 90 ASX-563 6 Groove Poly-V DIN 6-PK 56 ASX-575 6 Groove Poly-V DIN 6-PK 66 ASX-556 Speed calculation formula Crankshaft pulley diameter (mm) X Engine Speed = Chalwyn pulley drive diameter Alternator Speed page 3

Self-Exciting Flameproof Alternator - Model 310 Installation 1. Remove any existing non flameproof alternator from the diesel engine. 2. Check the alternator drive pulley ratio. In the case of fixed speed applications the pulley drive should be arranged to give a continuous alternator speed of between 5,000 rpm and 7,000 rpm. In the case of variable speed applications the pulley ratio should be selected to give an alternator speed of 2000 to 2,500 rpm at the engine low idle. This typically equates to a normal operating alternator speed range of about 3,500 rpm to 8,000 rpm. NOTE: a) The rear cover of the alternator may be rotated to give alternative cable entry positions. b) The standard cable entry gland supplied with the alternator is suitable for sealing on the outer sheath of unarmoured cable or on the inner sheath of armoured cable within the size range of 8.5 to 16mm diameter. c) The recommended inner core sizes for ASX-310 are 4mm². If suitable metric standard cable is not easily available and SWG or AWG must be used, please contact the Chalwyn factory with application details for technical advice on alternative possible cable core sizes. d) After installing the cable, a cable clamping device should be applied as near as possible to the cable gland. ASX-310 Rear Cover removed to show Terminals Negative (B- Terminal) Positive (B+ Terminal) 3. Prepare to fit the Chalwyn ASX-310 alternator in place of the standard alternator by modifying the support bracket and belt tensioning link as necessary. Check that adequate belt adjustment is available. Ensure that with the selected cable entry position, the alternator cable can be routed away from the alternator in such a way as to avoid potential mechanical or heat damage. 4. Remove rear cover of alternator. Prepare correctly rated cable for fitting to the terminals as shown below. Note, the main positive and negative terminals are designed for M5 ring connections. When slackening or tightening the terminal nuts, particular care should be taken not to slacken the M5 nuts at the base of the terminal posts. The speed signal connection should be made using a right angle spade connector to avoid bending the cable (eg. RS part 161-2008). Use ties to restrain the cables to prevent mechanical damage 5. Refit the rear cover after ensuring the O ring seal is undamaged and is properly seated in the seal groove. Torque the rear cover fasteners to 15Nm (11 lb feet). 6. Fit alternator to engine. See diagram page 2 for location of earth / ground threaded hole. Fit external earth wire from M4 tapped hole in the alternator rear cover to a clean position on the engine. Use a 4mm 2 section cable, ring terminals and shake proof washers. Also check that the engine is electrically bonded to its base frame or equivalent and, if metal braided armoured cable is used, the braiding is electrically bonded to the engine. 7. Fit an antistatic (conductive) drive belt and check it is correctly tensioned. The maximum side force must not exceed 565 Newtons (127 lbs) to avoid premature wear and alternator failure. Any sprung tensioner as used in serpentine drive arrangements must be adjusted so that the side force limit is not exceeded. Speed Signal (W Terminal) Regulator Special Notes: a. The cable entry point exceeds 70 C under rated conditions, therefore, in accordance with EN60079-0 clause 16-6, suitably rated cable shall be selected for installation. b. The output voltage from the alternator is controlled by an internal regulator. It is recommended however that over voltage protection is fitted to any circuit supplied by the alternator in which one or more components could become a potential source of ignition should over voltage occur. page 4

Self-Exciting Flameproof Alternator - Model 310 Operation Reduce the electrical load to the minimum possible whilst starting the engine. In particular any incandescent lamps to be powered by the ASX-310 should be switched off prior to starting engine (see also APPLICATION ). Once the engine fires and runs it may be necessary to accelerate to a moderate speed to start the alternator excitation. Once an output is established and the electrical load fully switched on the engine r.p.m. may then be reduced. Maintenance Routine maintenance is to be undertaken as follows : MONTHLY - Check drive belt is in serviceable condition and is correctly tensioned. - Check alternator mounting fasteners are tight. - Check alternator cable is properly supported and free from damage. - Check air passages under fan cowl are clear of any significant build up of foreign matter. - Check to ensure good electrical bonding exists between the alternator, engine and engine base frame and, if applicable, the metal braiding of the alternator output armoured cable. THREE MONTHLY YEARLY (or each 2,000 hours - whichever occurs sooner) - Check end float at alternator cooling fan. This must not exceed 0.2mm (0.008 ) when alternator is cold. - Check fan to cowl clearance. At worst point this must be greater than 1.0mm (0.040 ). - Remove alternator rear cover. Loosen the two fasteners locating the regulator carefully noting the position of the insulating and steel washers (see diagram under INSTALLATION). Replace regulator and brush assembly with a new assembly ensuring the various washers are replaced correctly and the fasteners are re-tightened. - Clear any dust from the rear cover area. Check cable condition is acceptable for further service. Check and tighten as necessary all terminals. - Check in turn that each alternator terminal is electrically isolated from the alternator body. - Check rear cover O ring seal is suitable for further service and is properly located in the seal groove. Refit rear cover torqueing fasteners to 15Nm. Tighten cable gland. Maintenance Note:- a. The M6 socket head cap screws utilised for fastening the end covers must only be replaced by cap screws with a yield strength better or equal to 830 N/mm 2. b. Any maintenance problems not covered by the above routine maintenance schedule should be discussed with your Chalwyn Distributor before any repair work is undertaken. page 5

Chalwyn by AMOT sales@chalwyn.co.uk www.chalwyn.com A division of Roper Industries Limited UK Western Way Bury St Edmunds Suffolk, IP33 3SZ Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 China Rm 308, Building No A8 Jiahua Business Center 808 Hongqiao Road Shanghai 200030 Tel +86 (0) 21 6447 9708 Fax +86 (0) 21 6447 9718 USA 8824 Fallbrook Drive Houston TX 77064 Tel: +1 281 940 1800 Fax: +1 713 559 9419 Canada 3230 97 Street Edmonton Alberta, T6N 1K4 Tel: +1 780 465 4429 Fax: +1 780 469 6275 CHALWYN RESERVES THE RIGHT TO UPDATE THIS PRODUCT SPECIFICATION WITHOUT PRIOR NOTICE.