PB-Series. GFCI/ELCI & Panel Seal

Similar documents
G-Series. Circuit Breaker.

PD-Series Ground Fault Circuit Protection

F-Series. Circuit Breaker

F-Series. Circuit Breaker

CX-Series. Circuit Breaker

MS-Series. Circuit Breaker

Renewable Energy. Circuit Breakers and Disconnects

G-Series DIN-RAIL CIRCUIT BREAKER

J-Series CIRCUIT BREAKER

L-Series. Circuit Breaker

H-Series. Circuit Breaker.

PDR circuit breaker - Ground fault Datasheet

FR circuit breaker - hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

ER circuit breaker - Hydraulic magnetic,

209 Series. Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors

Carling Circuit Breakers

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

F-Series General Specifications

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Products :: Circuit Protection :: Thermal Circuit Breakers

Catalog Issued 3-03 (PDF Rev )

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

CR circuit breaker - hydraulic magnetic,

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

Thermal Overcurrent Circuit Breaker 3120-F...

Selection Guide. Control Circuit and Load Protection

RBR circuit breaker - Remote operated

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

ID ID. Series 19. Mechanical Products Company

Thermal-Magnetic Circuit Breaker M1-...

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Thermal Overcurrent Circuit Breaker 3120-F...

DD Frame - Series Circuit Breakers

Thermal Overcurrent Circuit Breaker 3120-F...

Transfer switch OTEC open or delayed transition

Electronic Circuit Breaker ESS20-0..

Thermal-Magnetic Circuit Breaker 201/-WA

Circuit Breakers Circuit breakers are

Magnetic and Hydraulic-Magnetic Circuit Breaker

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Thermal Overcurrent Circuit Breaker 3130

Magnetic Overcurrent Circuit Breaker

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

1492-CB 1492-GH 1492-GS

Thermal-Magnetic Circuit Breaker M1-..

Thermal Circuit Breaker 3120-F...

Circuit Breakers Series AM/S

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

OTEC Transfer switch open transition

SECTION MOTOR CONTROL

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

SECTION PANELBOARDS

TMC 91H is now TMC 60 C Series

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

Thermal Overcurrent Circuit Breaker 3130

Magnetic and Hydraulic-Magnetic Circuit Breaker

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker

Transfer switch OTEC and OTECSE open transition

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Thermal Circuit Breaker / Switch Series 3131

1489-M Circuit Breakers

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

Thermal Overcurrent Circuit Breaker 3130

Industrial Control Transformers

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Electronic Circuit Breaker ESS20

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Horizontal Circuit Switchers

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors

Horizontal Circuit Switchers

IN2 Enclosed Switches and Circuit Breakers

Electromagnetic Industries LLP

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Typical Applications: Product Highlights:

BD-SERIES. BD-Series BATTERY DISCONNECT POWER SWITCH. Resources: Product Highlights: Typical Applications:

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Transcription:

PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heat-induced nuisance tripping is avoided. Features: Overload, short circuit and ground fault protection in a single package Handle or rocker style actuators Wiping Contacts - Mechanical linkage with two-step actuation cleans contacts, provides high, positive contact pressure & longer contact life. A trip-free mechanism, a safety feature which makes it impossible to manually hold the contacts closed during overload or fault conditions. A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. Front panel mounting Integral push-to-test button Benefits: Increases safety around boats and marinas Protects against electrical shock hazards in areas near water Protects against defects in wires & conductors Reduces fire and shock hazards from defects in permanently installed appliances such as water heaters, battery chargers, lighting fixtures, etc. Detects lower level ground faults which do not trip ordinary circuit breakers, but can lead to fires, and shock hazards for boating occupants Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062-77 Phone: (860) 793-928 Fax: (860) 793-923

2 PB-Series Circuit Breaker - General Specifications Electrical Tables Table A: UL Listed configurations and performance capabilities as Circuit Breakers. Electrical O H M S 000 00 0 0. 0.0 0.00 0.0 VOLTS HERTZ (AMPS) Maximum Voltage 20/240VAC 60 Hz Current Ratings Standard current coils: 0.00, 0.250, 0.500, 0.750,.00, 2.50, 5.00, 7.50, 0.0, 5.0, 20.0, 25.0 & 30.0 amps. Other ratings available, see ordering scheme. Insulation Resistance Minimum of 00 Megohms at 500 VDC. Dielectric Strength UL, CUL - 500 V 60 Hz for one minute between all electrically isolated terminals. PB-Series circuit breakers comply with the 8mm spacing and 3750V 60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between adjacent poles Impedance Values from Line to Load Terminal. 0. 0 00 AMPERE RATING Leakage To Ground Multiple of Rated Current Ampere Rating CURRENT (AMPS) 0.00-5.0 5. - 20.0 20. - 30.0 *Manufacturer reserves the right to change product specification without prior notice. 2x I r 60 Hz /2 Cycle Inrush Pulse Tolerance 4.65 8.33 TOLERANCE (%) ± 5% ± 25% ± 35% Pulse Tolerance Curve Time Delay Curves 22, 24, 26 t 6.67 Time in Milliseconds Standard Must Trip 20/240VAC 60 Hz Leakage Current Ratings 5 & 30 milliamps. 5± ma for UL943, other leakage ratings test to UL053. For other ratings, consult factory. Trip Time 300 ms Max. @ 00%, 40ms Max. @ 500% of must trip leakage current. Test Button On unit face along side of actuator. Mechanical Endurance Trip Free Trip Indication Physical Number of Poles Internal Circuit Config. Weight Standard Colors 0,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All PB-Series Circuit Breakers will trip on overload or ground fault, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the OFF position when an overload or ground fault causes the breaker to trip. - 3 poles, where the third pole is neutral Series Trip Approximately 65 grams/pole. (2.32 ounces/pole.) Housing- Black; Actuator - See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 00 Gs, 6ms, sawtooth while carrying rated current per Method 23, Test Condition I. Ultrashort curves tested @ 90% of rated current. Vibration Withstands 0.060 excursion from 0-55 Hz, and 0 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 06D, i.e., ten 24-hour cycles @ + 25 C to +65 C, 80-98% RH. Salt Spray Method 0, Condition A (90-95% RH Thermal Shock @ 5% NaCl Solution, 96 hrs). Method 07D, Condition A (Five cycles @ -55 C to +25 C to +85 C to +25 C). Operating Temperature -35 C to +65 C Corrosion Tested per UL943 FMG Test. 3 weeks @ 30 C 75% RH, 00ppb H2S, 20ppb CI2, 200ppb NO2 Agency Certifications UL Listed UL Standard 489 UL Standard 077 UL Standard 943 UL Standard 053 Circuit Breakers, Molded Case, (Guide DIVQ, File E29899) Supplementary Protectors Class A Ground Fault Circuit Interrupters Ground Fault Sensing and Relaying Equipment

PB-Series Ordering Scheme 3 PB A B A 24 620 2 B A A G Series 2 System Voltage/Poles 3 Circuit 4 Actuator 5 Frequency & Delay 6 Current Rating 7 Terminal 8 Actuator Color 9 Mounting/ Barriers 0 Trip Level Agency Approval SERIES PB 2 SYSTEM VOLTAGE / POLES A single phase, one pole B 20/240 VAC single phase, two pole C 20/240 VAC single phase with switched neutral, three pole D two pole with switched neutral 3 CIRCUIT B Series Trip (Current) 4 ACTUATOR Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Flat Visi-Rocker Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single Color Flat Rocker 3 Vertical legend 4 Horizontal legend 7 TERMINAL 2 3 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 w/upturned lugs 3 Screw 8-32 (Bus Type) 4 Screw 0-32 w/upturned lugs 5 Screw 0-32 (Bus Type) 9 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole A 6-32 X 0.95 inches B ISO M3 x 5mm B C E H Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M4 (Bus Type) Screw M5 (Bus Type) 8 ACTUATOR COLOR & LEGEND Handle Rocker Actuator Color Actuator Color I-O ON-OFF Dual Single Visi-Rocker White A B Black White Black C D 2 White N/A Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange BARRIERS yes yes 0 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT A 5 MA (CLASS A GFCI) 3,4,5 E 30 MA (ELCI) AGENCY APPROVAL G UL489 Listed, CSA Certified C UL077 I UL077/UL500 Ignition Protected, CSA Certified 6 5 FREQUENCY & DELAY 22 60Hz Short 24 60Hz Medium 26 60Hz Long 6 CURRENT RATING (AMPERES) CODE AMPERES 20 0.00 25 0.50 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 40.000 52.250 45.500 57.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 60 0.000 70 0.500 6.000 7.500 62 2.000 72 2.500 63 3.000 64 4.000 65 5.000 66 6.000 67 7.000 68 8.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 Notes: Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 2 Screw Terminals are recommended on ratings greater than 20 amps. 3 Available with leakage current trip level - Max trip current code E, and agency approval C. 4 6mA per UL943, available with agency approval code G. 5 30mA per UL053, available with agency approval codes C & G. 6 UL500 only available with 30MA trip level.

SCALE 0.500 SCALE 0.500 4 PB-Series Dimensional Specifications INDICATE "ON" 3.03 [ 76.9].25 [ 3.6].55 MAX [38.48].2 [ 5.3] TEST LINE INDICATE "OFF" AND SINGLE COLOR 2.7 [ 55.0] -POLE VERSION TEST LINE #6-32/M3 MOUNTING INSERTS LINE TERMINAL.88 [ 47.8] 2.265 MAX [57.53] 2.58 [ 65.6] CURRENT TRANSFORMERS.660 [ 42.6].39 [ 9.9] TEST 2.37 [ 60.2].375 [ 9.53].500 +.020 -.000 38.0 +.50 -.00 [ ].750 TYP [ 9.05] TERMINAL GFCI WIRE 2-POLE 20/240 VAC VERSION.20 [ 5.] Ø.56 TYP [ 3.96].260 [ 32.00].660 [ 42.6] 2.250 +.020 -.000 57.5 +.50 -.00 [ ] PANEL CUTOUT BREAK POLE.750 TYP [9.05] 3.05 MAX [76.58] TEST 2-POLE 20/240 VAC WITH BREAK Notes: All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.5] unless otherwise specified.

PB-Series Dimensional Specifications 5 Notes: All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.5] unless otherwise specified.

6 PB-Series Wiring Diagrams 20VAC with Switched Neutral SYSTEM 20VAC without Switched Neutral SYSTEM GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LINE/SOURCE () LINE/SOURCE () LINE/SYSTEM AC SOURCE AC SOURCE WITH SWITCHED WITHOUT SWITCHED 20/240VAC with Switched Neutral SYSTEM 20/240VAC without Switched Neutral SYSTEM GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL 2 (2) LINE/SOURCE LINE/ SOURCE 2 LINE/SYSTEM LINE/SOURCE () LINE/ SOURCE (2) 240 VAC 240 VAC AC SOURCE WITH SWITCHED AC SOURCE WITHOUT SWITCHED

PB-Series Panel Seal Ordering Scheme 7 8 Type Number PB 4 2 Series 3 Actuator 4 Poles 5 Mounting TYPE NUMBER 8 Circuit Breaker Assembly 2 SERIES PB 3 ACTUATOR TYPE Handle, one per pole 2 Handle, one per multipole unit A Rocker 2 4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE 2 Two 3 Three 4 Four 5 MOUNTING SCREWS / PLATE MATERIAL 6-32 Thread Phillips Head 2 M-3 Thread Phillips Head 3 6-32 Thread Slotted Head 4 M-3 Thread Slotted Head 5 6-32 Thread Phillips Head w/ Stainless Steel Plate 6 M-3 Thread Phillips Head w/ Stainless Steel Plate 7 6-32 Thread Slotted Head w/ Stainless Steel Plate 8 M-3 Thread Slotted Head w/ Stainless Steel Plate Notes: Screws supplied to accommodate mounting panel thickness of /8 ± /32. Consult Factory for additional options 2 Available for Flat and Curved Rocker options - No Rockerguard Bracket Handle Style Panel Seal Rocker Style Panel Seal

8 PB-Series Panel Seal Configuration - Drawings Handle Actuator Rocker Actuator

PB-Series Time Delay Curves 9 Time Delay Curves Instantaneous Medium Short Long REV_GFCI_PB_09_203