Simulation evaluation of capacitor bank impact on increasing supply current for alumunium production

Similar documents
The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

A conceptual design of main components sizing for UMT PHEV powertrain

Steering Dynamics of Tilting Narrow Track Vehicle with Passive Front Wheel Design

A view on the functioning mechanism of EBW detonators-part 3: explosive initiation characterisation

Stanley-Adamson: The First Industrial Size Variable Speed Compact Hydro Project Worldwide

Implementation of telecontrol of solar home system based on Arduino via smartphone

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Failure Modes and Effects Analysis for Domestic Electric Energy Meter Using In-Service Data

Comparative study between double wish-bone and macpherson suspension system

Research of the pre-launch powered lubrication device of major parts of the engine D-240

Analysis of 20 kv Power Distribution System Reliability using the Section Technique

Reactive Power Compensation for Solar Power Plants. Andy Leon IEEE PES Chicago Chapter December 12 th, 2018

Researches regarding a pressure pulse generator as a segment of model for a weighing in motion system

Development of Dynamic Calibration Machine for Pressure Transducers

Development of the automated bunker door by using a microcontrollersystem

Impact of air conditioning system operation on increasing gases emissions from automobile

Targeted Application of STATCOM Technology in the Distribution Zone

Design of pneumatic proportional flow valve type 5/3

Final Draft Report. Assessment Summary. Hydro One Networks Inc. Longlac TS: Refurbish 115/44 kv, 25/33/ General Description

The analysis of the accuracy of the wheel alignment inspection method on the side-slip plate stand

Arresting and supplying apparatus for increasing pellet impact drilling speed per run

Registration of the diagnostic signals of the starting system for selected faults

DC Substation Solutions For Metal Processing Applications

American Journal of Science, Engineering and Technology

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Energy balance in motor vehicles

Combined hydraulic power vehicle transmission modes

DOWNLOAD OR READ : ELECTRICAL POWER SYSTEM ANALYSIS PDF EBOOK EPUB MOBI

Scroll Compressor Oil Pump Analysis

Dynamic Control of Grid Assets

Feasibility Study Report

China. Fig. 1 Chain SVG Electrical Diagram

The influence of thermal regime on gasoline direct injection engine performance and emissions

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Design of Control System for Vertical Injection Moulding Machine Based on PLC

Physical Modelling of Mine Blast Impact on Armoured Vehicles

Design and Analysis of Hydraulic Chassis with Obstacle Avoidance Function

New 115 kv Disconnect Switches at Bloomsburg MTS

Mathematical Modeling Analysis of Operation Strategy after External Transmission Line Series Compensation

Development of a solar charged laboratory bench power supply

PV Grid Integration Research in the U.S.

Reactive power support of smart distribution grids using optimal management of charging parking of PHEV

Analysis of Grid Connected Solar Farm in ETAP Software

Feasibility Study Report

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

Possibilities of Distributed Generation Simulations Using by MATLAB

DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.

Plasma technology for increase of operating high pressure fuel pump diesel engines

The 2nd Asian Automobile Institutes Summit. Bali,25 26 November Modelling and Analysis of Electric Vehicle DC Fast Charging ginfrastructure

Investigation of a promising method for liquid hydrocarbons spraying

Generation Interconnection Facilities Study For

ScienceDirect. Simulation and Testing of a Typical On-Board Charger for ITB Electric Vehicle Prototype Application

New York Science Journal 2017;10(3)

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Relative Power Factor Correction costs

Physical Design of a Volt/Var Implementation

Study of intake manifold for Universiti Malaysia Perlis automotive racing team formula student race car

Evaluation of phase separator number in hydrodesulfurization (HDS) unit

Study concerning the loads over driver's chests in car crashes with cars of the same or different generation

Characterization of Voltage Rise Issue due to Distributed Solar PV Penetration

JORIND 9(2) December, ISSN

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Workhorses of industry

An Alternative to Reduce Medium-Voltage Transient Recovery Voltage Peaks

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Est DCM Double Conversion Module 400kVA - 800kVA

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Research of the alternator on the stand efficiency aspect

Dynamic Reactive Power Control for Wind Power Plants

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Voltage Control Strategies for Distributed Generation

Static Voltage Stability Investigations on a Part of a Transmission Grid

Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Operational Planning Study Report. RTA to BCH transfer limit updates For Kitimat 4 Capacitor Banks

Effect of plus sizing on driving comfort and safety of users

Methods of reducing power losses in distribution systems

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Keyword: Power Distribution System, Three-Phase Power Flow, Simplified Model, Distributed Energy Resources, Load Flow.

Influence of motorcycles lane to the traffic volume and travel speed in Denpasar, Indonesia

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

IEEE Transactions on Applied Superconductivity, 2012, v. 22 n. 3, p :1-5

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

Power Protection Discrete Automation & Motion South Africa

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

OPTIMUM ALLOCATION OF DISTRIBUTED GENERATION BY LOAD FLOW ANALYSIS METHOD: A CASE STUDY

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

Dynamic Control of Grid Assets

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

Efficiency Increment on 0.35 mm and 0.50 mm Thicknesses of Non-oriented Steel Sheets for 0.5 Hp Induction Motor

Optimal route scheduling-driven study of a photovoltaic charging-station (parking lot) for electric mini-buses

Numerical Simulation of the Effect of 3D Needle Movement on Cavitation and Spray Formation in a Diesel Injector

BC HYDRO T&D SYSTEM OPERATIONS SYSTEM OPERATING ORDER 7T 30. NORTH COAST INTERCONNECTION Supersedes 7T-30 issued 07 June 2018

Feasibility Study Report

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS Simulation evaluation of capacitor bank impact on increasing supply current for alumunium production To cite this article: S Hasan et al 2018 J. Phys.: Conf. Ser. 978 012062 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 14/07/2018 at 01:29

2nd International Conference on Computing and Applied Informatics 2017 Simulation evaluation of capacitor bank impact on increasing supply current for alumunium production S Hasan, K Badra, R Dinzi and Suherman* Department of electrical engineering Univesitas Sumatera Utara 20155, Indonesia * E-mail: suherman@usu.ac.id Abstract. DC current supply to power the electrolysis process in producing aluminium at PT Indonesia Asahan Aluminium (Persero) is about. At this condition, the load voltage regulator (LVR) transformer generates 0.89 lagging power factor. By adding the capacitor bank to reduce the harmonic distortion, it is expected that the supply current will increase. This paper evaluates capacitor bank installation impact on the system by using ETAP 12.0 simulation. It has been obtained that by installing 90 MVAR capacitor bank in the secondary part of LVR, the power factor is corrected about 8% and DC current increases about 13.5%. 1. Introduction Capacitor bank is widely used in electrical power system to improve the power factor. Capacitor is acting as a reactive load generator and connected in paralel to load compensating the lagging current [1-4]. Capacitor reduces reactive current and reactive power so that the power loss and dropped voltage decrease, and load voltage increases. Capacitor bank topology consits of grounded and ungrounded wye as shown in Figure 1. Multiple Units Grounded Single Wye Multiple Units Grounded Double Wye (a) Multiple Units Ungrounded Single Wye Multiple Units Ungrounded Double Wye (b) Figure 1. Capacitor bank configuration: (a) Grounded Wye, (b) Ungrounded Wye Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

2nd International Conference on Computing and Applied Informatics 2017 This paper reports the simulation conducted when planning capacitor bank integration to PT Indonesia Asahan Aluminium (Persero) or PT. Inalum, to increse electrolysis current. 2. Research Method Power flow calculation in existing condition is performed by modelling the electrical network within PT Inalum starting from generator, transmission system, smelter loads and the simplified interconnection with the public electrical operator (PLN) by using ETAP 12.0. The system states are based on the measured parameters using SCADA of PT Inalum [5]. Manual calculation is performed to determine the size of the capacitor bank. The main station (Gardu Induk) of PT. INALUM has 4 units LVR. Each has capasity. The LVR adjusts and stabilizes output voltage for rectifier transformer [6]. Each electrolysis potline is served by a single unit LVR with 3 taps of NVTC (No Voltage Tap Changer). Each NVTC tap has 27 OLTC (On Load Tap Changer) taps. Tap works as a voltage regulator to anticipate load fluctuation. Figure 2 shows the model of the electrical system within PT. Inalum. Bus Kuala Tanjung 275 kv MTR-1 MTR-2 MTR-3 MTR-4 LVR-1 LVR-2 LVR-3 LVR-4 Bus 33 kv Pot Line-1 Pot Line-2 Figure 2. Electrical network model of PT. Inalum Pot Line-3 3. Evaluation Results 3.1. Capacitor Bank Calculation The reactive power generation in some conditions are approximated by using Equation1 and 2. Potline AC Power = Potline DC Power Conversion Constant (1) Potline DC Power = I dc V dc PIO (2) The minimum current, the existing current, upgrade alternative 1 and 2 are plotted in Table 1. The alternative capacitor bank implementations are based on maximum and partly compensated capacitor bank values. The maximum current (6 x 37 ka = 222 ka) requires 89.9 MVAR reactive power. This research uses the capacitor bank of 2x as plotted in the maximum current of 222 ka. It is referred to as upgrade 1, while is upgrade 2. 2

Average Power Factor 2nd International Conference on Computing and Applied Informatics 2017 Condition I dc (ka) V dc PIO Table 1.Reactive power requirement P dc P/L (MW) P ac P/L (MW) Q P/L (MVAR) S P/L (MVA) Min.Current 130 4.4 V 165 pot 94.4 97.5 52.6 110.8 Normal 193 4.4 V 165 pot 140.1 144.7 78.1 164.5 upgrade 1 210 4.4 V 165 pot 152.5 157.5 85.0 179.0 upgrade 2 222 4.4 V 165 pot 161.2 166.5 89.9 189.2 3.2. Power system model with capacitor addition By integrating capcitor bank to model as in Figure 2, the integration model is shown in Figure 3. Capacitor bank is in grounded Wye model. Bus Kuala Tanjung 275 kv MTR-1 MTR-2 MTR-3 MTR-4 LVR-1 LVR-2 LVR-3 LVR-4 Bus 33 kv Pot Line-1 Pot Line-2 Pot Line-3 Figure 3. Electrical network model of PT. Inalum with capacitor bank integration There are 3 pot lines shown in Figure 3, with MTR and LVR. The capacitor bank is parallel to STR and SR. 3.3. Impact on power factor and current improvements Figure 4 shows impacts of capacitor bank integration. At normal condition, the power factor is slightly above 0.89. By adding upgrade 1, power factor moves upward to about 0.96. By fully connecting all capacitors, power factor is stable in 0.99. 1 0,95 0,9 0,85 0,8 Existing Upgrade 1 Upgrade 2 Conditions Figure 4. Impact on power factor 3

Current (A) 2nd International Conference on Computing and Applied Informatics 2017 The reactive power decrement reduces secunder currents of LVR from 2930 A to 2727 A (upgrade 1) and 2587 A (upgrade 2). The LVR secunder current reductions increase the rating of electrolysis potline, so that the current can achieve 219 ka. 3000 2900 2800 2700 2600 2500 2400 Existing Upgrade 1 Upgrade 2 Figure 5. LVR current decrement 4. Conclusions Based on the results of ETAP 12.0 simulation, a single capacitor bank installation on the system increases the power factor from 0.89 to 0.95. The 2x capacitor bank installations improve power factor to 0.99. Further, the LVR secondary current reduces from 2930 A to 2727 A (for capacitor bank) and 2587 A (for 2x capacitor bank).this reductions enable the potline current capacity increases from to maximum 219 ka. This increment is useful for increasing alumnium production. References [1] Maswood A I and Fangrui L 2009 A Unity PF Rectifier-Inverter Under Unbalanced Supply. Power & Energy Society [2] Pontt J, Rodriguez J, and Martin S J 2005 Power Electronics Specialists Conference (PESC), IEEE 36th. [3] Sheldon P K 2002 IEEE Transactions on Industry Applications, 38 (4). [4] Malaviya A K and Bundell G A 2001 IEEE Transactions on Industry Applications, 37 (3). [5] Load Dispatching Center Hand Book,( PT Indonesia Asahan Aluminium (Persero), Indonesia). [6] Yang J 2012 IET Electric Power Applications 7(6). 4