Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

Similar documents
Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Technical Information Cleanfit CPA451

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Technical Information Liquiline System CAT810

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Technical Information Cleanfit CPA472D

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Technical Information Cleanfit Control CYC25

Technical Information Cleanfit CPA871

Operating Instructions Flexdip CYA112

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

Technical Information Ceraliquid CPS41D and CPS41

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Stamolys CA71AM. Technical Information

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

Conductivity Measurement CLM 280

Technical Information Cleanfit CPA875

Operating Instructions CYR52

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Orbipore CPS91 and CPS91D

Ceraliquid CPS42/CPS42D/CPS43

Orbisint CPS12/CPS12D/CPS13

Special Documentation Mechanical accessories for pressure measuring devices

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

INSERTION Adaptor for analysis

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

Positive displacement flowmeter for continuous flow measurement

Orbisint CPS11 and CPS11D

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

Metal tube variable area flowmeter for gases, liquids and steam

ELADOS EMP IV E00 Diaphragm Pump type

INSERTION flow sensor for continuous flow measurement

SCHOTT Instruments Process holders and accessories CHEMTRAC

Oxiperm 164 D for 30 to 2000 g/h

Servo-operated 2/2-way solenoid valves Type EV220A

Oxiperm 164 C for 150 to 2500 g/h

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Flow-Through Fitting ARF 215

AMIAD "TAF" FILTER SERIES

Self-operated Temperature Regulators Type 1u Temperature Regulator

MAHLE Automatic Filter Series R8-30W

P200 Pressure Regulator

Orbisint CPS11 and CPS11D

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

1/4" JRPH/JRPL Series

Self-operated Temperature Regulators Type 1u Temperature Regulator

Self-operated Temperature Regulators Temperature Regulator Type 1u

METERING VALVES H1300 SERIES.

Stamolys CA71SI. Technical Information

Level Probe multicap DC 16

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Model PRH FLG. Stainless Steel 1500# Flange High Pressure Regulator (Reducing Valve) 21 Columbus Avenue Garfield, NJ 07026

Digital ph transmitter

RTD Temperature Sensor omnigrad T -TR 470

115 Series, Needle Valves, Single Block, Male x Male

3/2-way Solenoid Valve for pneumatics

Digital ph transmitter

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

Series 240 Type 3351 Pneumatic On/off Valve

Spring Loaded Safety Valve. SiC 11/13/14

JRPH/JRPL Series. Pressure Reducing Valves. a division of Jordan Valve PRESSURE REDUCING VALVE JRPH & JRPL SERIES FLOW CONFIGURATIONS

Mark 908 Series. Pressure Regulators Mark 908X Piloted Blanketing Regulators

P200 Pressure Regulator

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

Series 240 Pneumatic On-off Valve Type 3351

SENSOFIT RET 5000 Technical Datasheet

Diaphragm seal with threaded connection Plastic version Model

Probe holders for analytical probes

MV2-DT MV3-D2 MV3-RDP3 MV5-DT

Paddle-wheel flow controller for On/Off control

Inductive conductivity meter

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

GRUNDFOS DATA BOOKLET. DMX and DMH. Dosing pumps

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

F300 Pressure Regulator

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

2-Way/2 Position Valves

Valves and Solutions for the Process Industries

O2X DUO Dissolved Oxygen Sensor

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

413 barg 38 C 200 barg 230 C psig 100 F 3000 psig 750 F

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Sentronic PLUS 614 Series

Series 11 Miniature Pneumatic Solenoid Valve 15mm Solenoid Valve

Transcription:

Technical Information Flowfit CYA251 Flow assembly for nitrate/sac, turbidity and oxygen sensors Application The CYA251 flow assembly is designed for the installation of sensors with a diameter of 40 mm (1.57"). It can be used in all applications where the process medium is transported in pipes or is sampled and made available in closed pipes. The primary areas of application comprise: Drinking water Monitoring of surface water Analytical stations Process applications Wastewater technology Your benefits Simple wall or pipe-mounting Variable installation Self-venting by suitable mounting Short response times thanks to low internal volume. Automatic cleaning via cleaning nozzle (compressed air or water) Manual cleaning via cleaning port (depending on sensor) TI00495C/07/EN/02.12 71189517

Function and system design Measuring principle A complete measuring system comprises: Flowfit CYA251 flow assembly A 40 mm sensor, e.g. CAS51D Transmitter, e.g. Liquiline CM442 Measuring cable Measuring system (example) 1 Process pipe 2 Liquiline CM442 transmitter 3 Measuring cable 4 Return line with shutoff valve 5 CYA251 flow assembly with 40 mm sensor 6 Inlet with shutoff valve a0016022 Components 2 3 1 4 5 Flow assembly components 1 Inlet process connection 2 Sensor adapter (sensor-dependent) 3 Cleaning connection (cleaning nozzle is optional) 4 Outlet process connection 5 Cleaning port a0016117 2 Endress+Hauser

Cleaning The flow assembly is optionally fitted with a cleaning nozzle. You can connect compressed air or water at a G¼ connection for cleaning purposes. At the G¼ cleaning connection you can connect: Compressed air via the enclosed check valve (G¼ to 6 mm) or Water Optional cleaning 1 Cleaning connection 2 Cleaning nozzle with G¼ threaded connection 3 Plug a0016028 Manual cleaning via the lower cleaning port is possible with the turbidity and oxygen sensors but not with the CAS51D sensor. Endress+Hauser 3

Installation Installation instructions To ensure that medium flows through the assembly in a bypass configuration, the pressure p1 must be greater than the pressure p2. This is achieved by installing an orifice plate in the main pipe. Connection example involving a bypass and an orifice plate in the main pipe a0016023 p1 p2 p1 > p2 a0017221 Connection example involving a bypass and an orifice plate in the main pipe (assembly rotated by 90, inlet at bottom) 4 Endress+Hauser

No measures to increase pressure are required for branch pipes that branch off from the main pipe. Connection example involving an open outlet a0016024 The inlet and outlet connection of the flow assembly are always identical. The inlet and outlet side are not specified by the flow assembly and can therefore be selected to suit the particular application. Wall holder unit Wall holder unit 1 Hanger bolt STST 10x60 (forms part of the delivery) a0016088 Endress+Hauser 5

Environment Ambient temperature Storage temperature 0 to 50 C (32 to 120 F) 0 to 50 C (32 to 120 F) Process Process temperature Process pressure 0 to 50 C (32 to 122 F), not freezing Max. 6 bar (87 psi) at 20 C (68 F) and 4 bar (58 psi) at 50 C (122 F) Pressure-temperature diagram Pressure-temperature diagram a0016025 Flow Depends on the sensor used and the sensor's properties. Typical values: Minimum value: Maximum value: For oxygen sensors approx. 200 l/h (53 gal/hr) For turbidity and UV sensors approx. 100 l/h (26.5 gal/hr) Depends on the parameter to be measured but must be such that representative measured values are still delivered. It is not recommended to operate above 300 l/h (80 gal/hr). 6 Endress+Hauser

Mechanical construction Dimensions Dimensions a0016082 Sensor CAS51D 2 mm CAS51D 8 mm CAS51D 40 mm COS51D COS41 COS61D COS61 COS31 CUS31 CUS41 CUS51D Z mm(inch) 468 (18.43) 471 (18.54) 477 (18.78) 284 (11.18) 326 (12.83) 325 (12.80) 332 (13.07) Connections NPT ¾" Rp ¾ DN 25 ANSI 1" Hose D20 G1¼ X mm(inch) 83 (3.27) 83 (3.27) 83 (3.27) 50 (1.97) 137 (5.39) 61 (2.40) Y mm(inch) 50.5 (1.99) 50.5 (1.99) 50.5 (1.99) 115 (4.53) 50.5 (1.99) 44.5 (1.75) Weight Materials 1.5 to 1.8 kg (3.3 to 4.0 lbs), depending on the version EPDM (seals) PVC PP (flange) Endress+Hauser 7

Process connections Process connections A External thread G1¼, PVC B Flange ANSI 1", PVC C Glue-in port DN 25, PVC D Hose D20, PVC E Internal thread Rp ¾", PVC F Internal thread NPT ¾", PVC a0016046 Fitted sensors SAC or nitrate measurement CAS51D Oxygen measurement COS31, COS41, COS51D, COS 61 and COS61D Turbidity measurement CUS31, CUS41 and CUS51D 8 Endress+Hauser

Ordering information Order code Enter the following address in your browser to access the product page: www.products.endress.com/cya251 1. You can choose from the following options on the product page located on the right: 2. Click "Configure this product". 3. The configurator opens in a separate window. You can now configure your device and receive the complete order code that applies for the device. 4. Afterwards, export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the page. Scope of delivery The scope of delivery comprises: Flow assembly in the version ordered (contains the sensor adapter and process connection) Accessories ordered Adapter with check valve (for optional cleaning only, 6 mm connection for compressed air) 1 tube of lubricant (for O-rings) Operating Instructions, English When the flow assembly is delivered, the cleaning port and cleaning connection are fitted with dummy plugs. Endress+Hauser 9

Accessories Cleaning nozzle Cleaning nozzle for CYA251 For automatic sensor cleaning. Order number: 71144328 (suitable for the CAS51D sensor (2 mm or 8 mm gap)) Order number: 71144330 (suitable for the CAS51D sensor (40 mm gap)) Order number: 71144331 (suitable for the CUS51D, COS51D, COS61D, COS61, COS31, COS41 sensors) Order number: 71144332 (suitable for the CUS31, CUS41 sensors) 1 CYA251 with cleaning nozzle 1 Cleaning nozzle a0017219 Sensor adapter Sensor adapter for CYA251 Adapter for installing the following sensors: Order number: 71144333 (suitable for the COS61D, COS61, COS31 sensors) Order number: 71144334 (suitable for the COS41, COS51D sensors) Order number: 71144335 (suitable for the CUS51D sensor) Order number: 71144336 (suitable for the CUS31, CUS41 sensors) Order number: 71144337 (suitable for the CAS51D sensor (2 mm gap)) Order number: 71144338 (suitable for the CAS51D sensor (8 mm gap)) Order number: 71144339 (suitable for the CAS51D sensor (40 mm gap)) 1 CYA251 with sensor adapter 1 Sensor adapter a0017220 10 Endress+Hauser

Wall holder unit Wall mounting kit for CYA251 Order number: 71144369 Wall mounting kit 1 Hanger bolt STST 10x60 mm a0016088 Endress+Hauser 11

TI00495C/07/EN/02.12 71189517 Printed in Germany / FM+SGML 6.0 / DT