SHOWER VALVES SERIES Ø42

Similar documents
NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

VWR FOR SIEVING. Test sieve shakers and accessories. Ultrasonic sieving systems. Sample splitters. Test sieves. Standards.

Specification Grade Contemporary Wall Mount/Technical Installation Data

DAVIES CRANE HIRE LTD DAVIES PENSARN WORKS, PENSARN, CARMARTHEN, SA31 2NG TCC t

Fitting Instructions for RAD0171BK Radiator Guard YAMAHA MT

Captivate Illuminated Mirror Light

INSTRUCTIONS 315W CERAMIC METAL HALIDE E-BALLAST PHBC3150

Teile und Zubehör - Einbauanleitung

In this kit there should be: 1 x Engine Case Cover (ECC0085) 2 x M6x28mm long button head bolts PLEASE READ THESE INSTRUCTIONS FULLY BEFORE STARTING

MANUAL 18ST 18ST FS Version 1.0 Version 1.0

Operating manual FP-2. Index

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

USA only days warranty 180 Tage Garantie From the date of purchase + guaranteed spare part service

Manual 46ST 46ST FS Version 4.0

Installation Instructions

Manual 58 ST/FS & 62 ST/FS Version 1.5 Version 1.2

INSTALLATION INSTRUCTION Bollard Light 12V

EDITION Spare parts to fit European Trucks and Trailers. Ersatzteile Passend für Europäische LKW and Anhänger

Mobile Crane/Grue mobile LTM

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Installation and maintenance guide

1901 Thermostatic Shower Mixer

LAVTBYGGENDE BAKMONTERT BESLAG

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

INSTRUCTIONS CERAMIC METAL HALIDE REFLECTOR PHR3150

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

LED DayLite WireLess Mini

BALL VALVES VENTILE - VANNES. F l u i d & DISTRIBUTION OF HYDRAULIC EQUIPMENT

HM, HMK, HMC, HMN. Horizontal Multistage Centrifugal Pumps, 50Hz

60AZinkenverstellgeräte. 60A Ajusteurs de Fourches

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

MANUAL 52ST 52ST FS Version 2.5

Teile und Zubehör - Einbauanleitung

FITTING INSTRUCTIONS FOR CP0393BL AERO CRASH PROTECTORS SUZUKI GSX-S

Assembly Instructions Instrucciones para ensamblar Instructions de montage. Montageanleitungen Montage-instructies

MOONRING 1.5 MOONRING 3

CLAMP KIT FOR FULL GLASS DOORS

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

Made in Italy. SitLand S.p.A. è certificata secondo la Norma UNI EN ISO 9001:2008 Qualità Ambientale UNI EN ISO 14001:2004

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly.

MODEL VW2960C ASSEMBLY INSTRUCTIONS

FITTING INSTRUCTIONS FOR PKS0057SI KICKSTAND SHOE MV Augusta F

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

BULLETIN DE DIFFÉRENCIATION DES PRODUITS IPD Mai 2011

Fitting Instructions for RAD0164 BK/OR Radiator Guard KTM 390 DUKE 2013

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

Motorised Plasma/LCD Trolley

Stilo - Stilo/C. Kreadesign. wall lights indoor/outdoor. 314 led light solutions 3. design: Studio KD. ceiling bowls indoor/outdoor

Solid Clamps Raccords orientables

EA5506. Electrically Actuated Carbon Steel PN16 Ball Valve. Description

Assembly & Exercise Guide. Carefully reading and keeping the operating Instructions before use.

Thermostatic Floor-Mounted Bathtub Mixer

ZAZERI 48" ZAZERI 60"

PNEUMATIC PUMP FOR GREASE Pneumatic pump series

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

Slam-Shut Valve OSE LS. Europe, Middle East, and Africa Document Only CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual.

Operating Instructions (Translation of the original operating instructions) Leister TAPEMAT Hot-Air welding machine

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

UB-2 2 Universal Button

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

NAPAF - NAPBC HIGH PERFORMANCE AIRFOIL NAPAF AND BACKWARD CURVED NAPBC PLENUM FANS. 1 a Edition - subject to future integrations

SAUTER TVO Version /2014 GB

Fitting Instructions for RAD0141BK Radiator Guard KAWASAKI ZX-6R

Fitting Instructions for OCG0014BK Oil Cooler Guard Ducati Monster 1100 / 1100S / 1100EVO & 795/796 '09-

Retractor SM Installation Guide

GAS BURNERS BLU 3000 PR BLU 4000 PR

MOTOR CONTROLLER FOR WINDOW OPERATORS

Incassi a parete - Recessed wall-mounted luminaires THUNDER110. arcluce.it. thunder

PARTS LIST FOR ITEM 43511

(51) Int Cl.: H02K 1/27 ( ) H02K 1/32 ( ) H02K 1/20 ( ) H02K 7/18 ( )

FALCO AF3009. en Spare parts list Tire changer Equipment. Parti di ricambio Smontagomme

FITTINGS MIT CHEMIESCHUTZSCHICHT FITTINGS WITH CHEMICAL PROTECTION LAYER FITTINGS AVEC BARRIÈRE ANTI- CORROSION ÉPAISSE

RODLESS CYLINDERS VERINS SANS TIGE CILINDRI SENZA STELO

STRUKTUR Flexibler PVC-Schlauch mit Textilverstärkung. TEMPERATURBESTÄNDIGKEIT Von -20 C bis +60 C. Bursting Pressure bar *

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

ATZAF DOUBLE INLET AIRFOIL BLADEDBACKWARD CURVED CENTRIFUGAL FANS

Operating Instructions type Always on the safe side.

4:1 Fusion Static Mixer Kit

WASP-P PRESSURE SENSOR

OIL BURNERS. MINOR 1 Snorkel 240 Volt 50 Hz

Installation and Maintenance Instructions

CSD Series Current Devices Split Core

KTS Technical catalogue Catalogo tecnico Technischer Katalog

V-2410 Three-Way Multipurpose Solenoid Air Valve

Fitting Instructions for SRG0034 Radiator Guard Radiator Guard KAWASAKI VERSYS

Index. Primary components - back sections Composantes principales - traverses ou meneaux

2017 LED Emergency kit

Thermometer wih Remote Transmission Ø 100 mm Thermometer mit Fernübertragung Ø 100 mm

COSMETICS RANGE DISPENSERS

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

RECOMMENDED TOOLS AND CHECKERS

A1100 GUARDIAN OVERFILL PREVENTION VALVE (with Installation Kit)

Spun Bay Installation Standard Version (non dimmable), Hook Mount

SKU: APL. APL Series of Switchbox

DSP Standby Battery Charger

Transcription:

SHOWER VALVES SERIES Ø42 Instruction Manual Trim parts assembly MB439 MB440 MB441 MB442 MB443 MB444 MB446

INSTALLATION TRIM ASSEMBLY Remove protection covers from Rough in valve Temperature check - Temperature setting ring (cam) Rotate insert D by using handle E for setting temperature at 38 C. (check temperature with a thermometer). Remove handle and insert cam C onto shaft J. Assemble handle E with reference line in vertical position. Fully rotate handle E counterclockwise and check that water temperature is around 42 C. Remove handle E for fitting other trim parts as per further instructions. D E cam position vertical axis C J Pag. 1

INSTALLATION TRIM PARTS ASSEMBLY Fixing thermostatic valve trim ring After checking the correct deepness of the valve in the wall so that no shaft extensions are necessary, fix trim ring onto valve's body with the silicon supplied in the carton keeping the reference line in vertical position (12 O' Clock). Carefully remove with a blade any silicon residuals. Vertical line Silicon Fixing trim plate Allow the silicon of thermostatic trim ring to set. Apply some silicon on the trim plate and place it in position. Pag. 2

INSTALLATION TRIM PARTS (guide lines valid for all models) Fixing trim rings Check that O-ring gaskets X are seated into trim rings Y. Fully screw rings Y onto shafts A and B. Fixing thermostatic valve handle After positioning cam C as indicated in page 1, push handle F onto shaft insert D checking that the two reference lines coincide. Tighten grub screw with hexagonal key enclosed. Fixing diverter knob Check that diverter is in the closed position (in the centre). Fit handle F onto shaft insert G so that grub screw hole is on the bottom. Tighten grub screw and check that the handle can turn left and right. Fixing volume control knob Check that volume control is set on closed position. Place handle H onto shaft insert I with grub screw hole on the bottom. Tighten grub screw and check that the knob can open by rotating counterclockwise A G X Y C D F X Y E H Grub screws B I Hexagonal key 2mm (enclosed) Pag. 3

INSTALLATION 2 WAY DIVERTER - FUNCTIONAL SCHEME OUTPUT 1 CLOSED OUTPUT 2 Grub screw hole INPUT INPUT OUTPUT 1 OUTPUT 2 INPUT INPUT Pag. 4

SHOWER VALVES SERIES Ø42 Instruction Manual Maintenance MB439 MB440 MB441 MB442 MB443 MB444 MB446

MAINTENANCE CLEANING / REPLACING THERMOSTATIC VALVE 1) Close water mains 2) Remove handles and eventually the trim rings from the plate depending from the model. 3) Remove trim plate 4) Remove cam (Fig.1) Fig.1 5) Unscrew valve counterclockwise with a 30 mm spanner (Fig.2) Fig.2 6) Remove thermostatic valve and clean filters under running water. In the case of limescale, leave in vinegar for 12 hours. Before reassembling in the body, lubricate O-ring gaskets (Fig.3) If the O-ring gaskets are damaged, replace them by ordering part number O.062. filters Fig.3 7) If the valve needs replacing, remove also screw A and insert B which are to be used on the new valve (Fig.4) B A Fig.4 Pag. 5

MAINTENANCE CLEANING FILTER / CHECK VALVE 1) Close water mains 2) Remove handles and eventually the trim rings from the plate depending from the model. 3) Remove trim plate 4) Remove filter housing by unscrewing counterclockwise with spanner 27 mm (Fig. 5) Fig. 5 5) Clean filter under running water or leave it 12 hours in vinegar in the case of limescale (Fig.6) check valve Fig. 6 filter Pag. 6

MAINTENANCE REPLACING DIVERTER CARTRIDGE 1) Close water mains 2) Unscrew counterclokwise trim rings (1) (1 or 2 depending on the model) taking care of not damaging the O-ring gaskets (2). (Fig.7) Fig. 7 2 1 3) Remove trim plate. (Fig.8) Fig. 8 4) Remove screw (3), shaft insert (4) and shaft (5). Unscrew nut (6) with a spanner 21mm and remove diverter valve (7). 5) Before replacing the diverter, clean and lubricate it's seating. 6) Assemble diverter and all components after positioning correctly the 2 pins at its base. (Fig.9) 7 6 5 4 Fig. 9 3 Pag. 7

MAINTENANCE REPLACING VOLUME CONTROL VALVE 1) Close water mains. 2) Remove handles and trim rings (1) (one or two depending on the model) taking care of not damaging O-ring gaskets (2) (Fig.10) Fig. 10 2 1 3) Remove trim plate (Fig.11) Fig. 11 4) Unscrew threaded shaft (8) with a spanner 17 mm (Fig.12) 5) Unscrew valve (9) with an hexagonal key 17 mm (Fig.13) Fig. 12 Fig. 13 8 9 Pag. 8

Warranty MGS products are covered by a warranty of 5 years from purchasing date on all stainless steel parts and of 2 years on all other components. During this period, parts with construction defects in materials or workmanship will be replaced free of charge. This warranty will not r espond in the case of faults caused by unsuitable or improper use, wrong installation, natural wear, improper or careless treatment, wrong usage of cleaning or maintenance products. MGS will not assume liability for labour expended, freight cost or damages accruing from the use of the material purchased from us. If material is defective, the limit of damage is the price of the defective material. Proof of purchase (original sales receipt) from the original consumer purchase r must be made available to MGS for all warranty claims. The warranty is n ot transferable and is extended solely to the original purchaser of the product. Garantie Auf MGS Produkte gewähren wir Ihnen 5 Jahre Garantie ab Kaufdatum für alle Edelstahlteile und 2 Jahre für alle anderen Komponenten. Während diese Zeitraums werden alle Teile, die einen Konstruktionsfehler aufweisen, kostenlos ersetzt. Diese Garantie wird nicht gewährt bei unsachgemässem Gebrauch, falscher Montage, nachlässiger, Handhabung, falscher Anwendung von Reinigungsmitteln und fehlender oder mangelhafter Wartung. MGS ist nicht verantwortlich für eventuelle Eingriffskosten zu Hause des Kunden. Im Schadenfall entspricht die Rückerstattung des Schadens dem Preis des defekten Materials. Die Garantie ist nicht übertragbar und der Käufer muss Kaufdatum und Originalquittung vorweisen. Condizioni di garanzia Le parti in acciaio dei rubinetti MGS sono garantite per 5 anni, mentre gli altri componenti per 2 anni (cartucce, flessibili, ecc.). Durante il periodo di garanzia tutte le parti riportanti difetti dovuti a vizi di fabbricazione saranno sostituite gratuitamente. Questioni legate a un utilizzo anomalo o inadeguato, installazione difettosa, normale usura, uso negligente o errato, impiego di prodotti per la pulizia inadatti e a danni di trasporto non sono coperte dalla garanzia. MGS non è responsabile per eventuali costi di intervento al domicilio del cliente finale. In caso di difetto il limite del danno rimborsato è definito dal prezzo del materiale difettoso. L'acquirente per avere diritto alla garanzia deve dimostrare la data di acquisto con la prova di acquisto originale. Garantie Les robinets MGS sont garantis pour une période de 5 ans pour toutes les parties en acier inoxydable et de 2 ans pour les autres composants. Pendant la période de garantie toutes les parties avec un défaut de construction seront remplacées gratuitement. La garantie n a plus de validité dans les cas de mauvaise utilisation tels qu installation défectueuse, usage impropre, mauvais nettoyage, etc De même pour les dommages de transport et la normale usure. MGS n est pas responsable p our les frais d intervention au domicile du client final. Lorsqu un robinet est défectueux la limite du défaut ne peut pas dépasser le prix de la pièce défectueuse. La garantie commence à la d ate d achat du robinet et la facture originale est nécessaire afin d établir la validité de la garantie Progetti srl Corso Milano 189 28883 Gravellona Toce (VB) Italy Tel.: +39 0323 865218 Fax +39 0323 865215 www.mgstaps.com E-mail: info@mgstaps.com