Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

Similar documents
8.3kV, 9.9kV, 15.5kV, 17.2kV and 23kV Cooper ELSP Backup Fuses Testing per C

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

TEMPERATURE RISE TESTS

Faulted Circuit Interrupting Tests on Type CMU Power Fuses

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

K-Limiter high ampere Companion II fuse

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Technical Specification For Outdoor Substation Harmonic Filter Banks

Edison modular fuse, vault application products

3.2. Current Limiting Fuses. Contents

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

Product Selection Guide

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

Figure 1. Two and Three-phase MagneX.

CERTIFIED TEST REPORT

AutoLink Frequently Asked Questions

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

High-voltage high-breaking capacity VV fuse-links

How to Use Coordinaide to Protect Transformers Against Secondary-Side Arcing Faults.

PROTECTION AND CONTROL

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

EE 741 Over-voltage and Overcurrent. Spring 2014

X-Limiter full-range current-limiting fuse

Section 1 Introduction to the Presentation

High-voltage high-breaking capacity VV fuse-links

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

CMU medium voltage power fuses

ECET Distribution System Protection. Overcurrent Protection

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

CERTIFIED TEST REPORT. Cooper Power Systems. 25 kv Class 200 Amp 15.2/26.3 kv SEPARABLE CONNECTOR SYSTEM

Application of Hi-Tech Trans-Guard EXT and OS Shorty fuses

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

NX indoor current-limiting fuses

Molded Current-Limiting Fuse

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

34-SDMS-01 SPECIFICATIONS FOR

ELF -LR current-limiting fuse

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

FUSE TECHNOLOGY Ambient temperature

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Reducing. with Current. arc flash note 2. points of interest. Why Use Current Limiting Fuses. By mike lang, Principal field engineer

34-SDMS-02 SPECIFICATIONS FOR

High voltage high-breaking capacity VV fuse-links

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

n For use in telecommunication circuit applications requiring low current protection with high surge tolerance

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

COOPER POWER CA280012EN

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Expulsion Fuses. 2.2 Fuse Selection. 2.3 Application. 2.4 BA Type Fuses. 2.5 DBA Type Fuses. 2.6 DBU Type Fuses. 2.7 RBA and RDB Type Fuses

Recommended Procedures

POLYFUSE Resettable PTCs Surface Mount > 2920L Series

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

A 1.2 kv class externally removable secondary bushing

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Protective Device Coordination ETAP Star

M-Force three-phase switch

Low-Peak 600V Class RK1

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

Application of Primary Fuses

Eaton s Cooper Power Systems

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Tolerance-Based Time-Current Coordination

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Using Fuses to Provide Fault Protection of Windfarm Transformers

Semiconductor Fuses European Fuses

onlinecomponents.com

WATT MBH SERIES DC/DC CONVERTERS

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

FUSES. Safety through quality

Medium Voltage Metal-Enclosed Switches

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

RESPONSE OF A MEDIUM VOLTAGE CURRENT LIMITING FUSE OF SMALL SIZE TESTED AS GENERAL PURPOSE AND FULL- RANGE TYPE.

Prüffeld der Schaltwerke


Medium Voltage Metal-Enclosed Switches

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Transcription:

CP No.: CP9716 Rev. 02 Page: 1 of 9 CERTIFIED TEST REPORT Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses Rev. 02 DATE: June 3, 2010 ORIGINAL REPORT DATE: June 13, 1997 Cooper Power Systems, Inc.

CP No.: CP9716 Rev. 02 Page: 2 of 9 Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses CERTIFICATION Statements made and data shown, to the best of our knowledge and belief, are correct and within the usual limits of commercial testing practice.

CP No.: CP9716 Rev. 02 Page: 3 of 9 Overview The Cooper Power Systems Companion II 12K through 40K fuses are designed to be applied as backup current limiting fuses. In this application, the Companion II fuse provides protection against high current faults and limits the peak current and the amount of let-through energy to the protected equipment. The CPS Companion II fuse is typically applied in series with an expulsion fuse. When applied in series with an expulsion or other type of low current interrupting device, the combination provides full range protection. Certification Tests as required by IEEE Std C37.41-2008 1. Interruption Tests at Line-to-Neutral Rated Voltage Series 1 Rated Maximum Interrupting Current Series 2 Critical Current Series 3 Rated Minimum Interrupting Current 2. Temperature Rise Tests 3. Time Current Characteristic Tests 4. RIV Tests

CP No.: CP9716 Rev. 02 Page: 4 of 9 Requirements INTERRUPTION TESTS Back-up current-limiting fuses are required to operate on high available fault currents and limit the fault current magnitude and energy. They must interrupt these fault currents so that the other pieces of connected equipment are isolated from the electrical distribution system. Objective The objective of these tests is to verify the interrupting performance of the Companion II fuse for applications at the respective voltage rating by testing according to the requirements specified in ANSI/IEEE C37.41-2008, clause 6.6 and C37.47-2000. Procedures These tests were run on production fuses which were assembled using standard methods and procedures. The testing was conducted at ambient temperature. Test Results The Companion II 12K 40K fuses successfully interrupted each respective test current. The performance parameters are detailed in Table 1: Table 1: Interruption test results Test current Test Voltage close angle Melt I²t Total I²t Total Energy Melt time Clear time Withstand Part number A kv deg X/R ka²sec ka²sec kj msec msec (min) 8.3kV 12K 50600 8.3 40 35 5.30 9.56 22.0 0.360 --- 1 8.3kV 12K 50600 8.3 65 35 5.50 12.1 25.4 0.290 --- 1 8.3kV 12K 50600 8.3 65 35 5.85 11.7 24.2 0.290 --- 1 8.3kV 12K 2346 8.4 7 12 4.31 9.32 61.0 3.283 --- 10 8.3kV 12K 2392 8.5 8 12 4.27 9.65 63.5 3.217 --- 10 8.3kV 12K 2360 8.4 9 12 4.33 9.08 60.1 3.320 --- 10 8.3kV 12K 489.8 8.35 --- 1.7 6.66 6.91 --- 27.800 29.800 10 8.3kV 12K 507.8 8.35 --- 1.7 6.82 7.12 --- 26.500 28.600 10 8.3kV 40K 50600 8.4 20 30 59.2 124 116.0 0.900 --- 1 8.3kV 40K 50600 8.4 55 30 60.0 160 149.0 0.670 --- 1 8.3kV 40K 50600 8.4 55 30 60.9 151 138.0 0.650 --- 1 8.3kV 40K 8280 8.3 7 12 58.3 140 243.9 --- --- 10 8.3kV 40K 8310 8.3 7 12 57.9 139 241.7 --- --- 10 8.3kV 40K 8280 8.3 8 12 55.9 144 253.8 --- --- 10 8.3kV 40K 1001 8.4-97 2.1 261 267 20.4 262.040 268.880 10 8.3kV 40K 1002 8.4 43 2.1 250 255 20.3 246.850 253.930 10 17.2kV 12K 43500 17.3 40 35 5.40 10.0 50.4 0.370 --- 1 17.2kV 12K 43500 17.3 65 35 5.60 12.3 57.7 0.290 --- 1

CP No.: CP9716 Rev. 02 Page: 5 of 9 17.2kV 12K 43500 17.3 65 35 5.60 12.0 55.5 0.310 --- 1 17.2kV 12K 2380 17.6 11 12 4.43 10.7 143.8 3.129 --- 10 17.2kV 12K 2365 17.3 9 12 4.24 10.6 139.5 3.187 --- 10 17.2kV 12K 2373 17.4 11 12 4.16 10.7 141.3 3.078 --- 10 17.2kV 12K 510 18.0-76 2.3 7.06 7.61 26.1 29.043 37.474 10 17.2kV 12K 502 17.9-97 2.3 7.27 7.73 7.0 29.598 32.044 10 17.2kV 40K 43500 17.4 30 30 56.4 136 276.0 1.080 --- 1 17.2kV 40K 43500 17.4 55 30 57.1 164 341.0 0.890 --- 1 17.2kV 40K 43500 17.4 55 30 59.8 170 354.0 0.740 --- 1 17.2kV 40K 9390 17.2 4 11 56.0 144 475.7 3.215 --- 10 17.2kV 40K 9400 17.2 5 11 55.3 147 486.9 3.180 --- 10 17.2kV 40K 9390 17.2 7 11 54.7 152 499.6 3.085 --- 10 17.2kV 40K 1000 17.2 106 2.2 193 214 35.7 193.400 200.700 10 17.2kV 40K 1000 17.2-91 2.2 225 232 64.4 205.700 217.100 10 23kV 12K 31000 23.1 40 35 5.10 9.24 70.2 0.460 --- 1 23kV 12K 31000 23.1 65 35 5.10 10.8 81.3 0.350 --- 1 23kV 12K 31000 23.1 65 35 5.40 10.8 78.2 0.370 --- 1 23kV 12K 2350 23.3 8 12 4.28 10.4 175.9 3.217 --- 10 23kV 12K 2360 23.4 8 12 4.12 10.2 177.2 3.169 --- 10 23kV 12K 2360 23.4 10 12 4.04 9.89 173.2 3.118 --- 10 23kV 12K 517 24.1 113 2.3 6.85 7.34 12.3 27.910 31.099 10 23kV 12K 500 23-134 2.3 6.87 8.22 19.7 29.040 37.474 10 23kV 25K 31000 23 40 30 19.8 50.6 225.0 0.680 --- 1 23kV 25K 31000 23 55 30 21.4 56.1 250.0 0.630 --- 1 23kV 25K 31000 23 55 30 21.3 57.3 254.0 0.610 --- 1 23kV 25K 5470 23 16 12 17.2 45.7 316.8 2.809 --- 10 23kV 25K 5500 23 9 12 17.8 44.7 312.1 3.080 --- 10 23kV 25K 5470 23 10 12 17.0 45.8 323.3 3.075 --- 10 23kV 25K 514 23-60 2.2 112 115 42.2 439.400 454.700 10 23kV 25K 508 23 137 2.2 84.3 86.9 33.7 314.800 326.700 10

CP No.: CP9716 Rev. 02 Page: 6 of 9 Requirements TEMPERATURE RISE TESTS Backup current limiting fuses are required to carry all normal system steady state currents without incurring temperature rises that would be detrimental to any of the fuse parts. Objective The objective of this test is to verify that the temperature rise does not exceed the values specified in ANSI C37.47 and ANSI C37.40. Procedures Production fuses were tested per requirements specified in ANSI/IEEE C37.41 (Clause, 10). Current was supplied by a regulated current source. Temperature levels of the various current carrying parts were recorded throughout the duration of the test. Note that the fuse itself does not have a continuous current rating there is an implied rating that the fuse must carry about 1.5 times the rating of the cutout link it is used in series with i.e. 60 A for the 40K fuse. Test Results Temperature rises were below maximum temperature rise levels allowed by standard IEEE C37.40-2003 Table 1. Conclusion The Companion II 12K 40K fuses met the temperature rise requirements of Table 2 in ANSI/IEEE C37.40.

CP No.: CP9716 Rev. 02 Page: 7 of 9 Requirements TIME CURRENT CHARACTERISTICS TESTS Time current characteristic curves are primarily for application selections and system coordination studies. These curves, minimum melt and maximum clear, detail the performance data of a particular fuse design. Objective Establish time current characteristic curves for the 12K 40K Companion II fuses per ANSI/IEEE C37.47-1981 (R-1992) requirements. Procedure Testing was performed on production fuses which were assembled using established methods and procedures. Minimum melt and maximum clear time current characteristic curves were developed using ANSI/IEEE C37.41-2008, Clause, 12 requirements as a guideline. The curves reflect the typical industry tolerances ± 10% of the average melting current. An allowance for arcing time is also added to the total clearing curve to determine the fuse s total clearing characteristics. Testing was performed at ambient temperatures. Results and Conclusions The minimum melt and maximum clear TCC curves for the 12 40K Companion II backup current limiting fuses were developed using the procedure described above and are detailed in R240-91-165.

CP No.: CP9716 Rev. 02 Page: 8 of 9 Requirements RIV Testing RIV performance data for the Companion II fuse family is necessary in order to ensure proper performance of the fuse for the manner in which it is mounted in the field. Objective Determine RIV performance levels of the highest voltage and K-rated Companion II fuses; 17.2kV 40K, 23kV 12K and 23kV 25K. The highest rated fuses were chosen to represent the worst case condition; therefore this would represent successful performance of the entire Companion II fuse family. Procedure Testing was performed as detailed in ANSI C37.41-2008, Clause 8. Testing was conducted by mounting the fuse on top of a 27kV Type L cutout and was performed at 1 MHz. The fuses were secured to the cutout connector in the same manner as is typical field practice. An Electro-Metric meter, model EM-7535 S/N 144, was used to record the data. Results and Conclusions Applied rms Voltage (kv) Corrected Reading (µvolts) Fuse Part number Meter Reading (µvolts) FAH17KV40K 15.8 <10 <10 FAH23KV12K 15.8 <10 <10 FAH23KV25K 15.8 <10 <10 Barometer = 760.5 mmhg Dry Bulb = 23.5 C Wet Bulb = 16.5 C All fuses were less than the permissible maximum value, 250 µvolts, specified by standards. A 10 µvolt reading is considered RIV inception.

CP No.: CP9716 Rev. 02 Page: 9 of 9 Revision no. Date of addition/change REVISION HISTORY Addition/Change made to report 02 6/3/10 Updated report with new interruption data and RIV results Quality from Cooper Industries P.O. Box 1640, Waukesha, WI 53187