Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Similar documents
Industrial Power Supplies

Switching Power Supplies

C B. Operating up to 5000m altitude 5 year product warranty Models

Open Frame Power Supplies

Switching Power Supplies

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Load (2) Single or Dual

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Power Supplies. SDN-C Compact DIN Rail Series

GB60S 60W Single Output General Purpose Series

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

(typ.) (Range) Load

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

D R C- 4 0 s e r i e s

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

MD60 Series 60W DINergy Power Supply

QUINT-PS/24DC/24DC/ 5/CO

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Safety Standards. Model Number:

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

Features. Description. Table of Contents

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

AC/DC Converter MBP250-2A13D13M

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

RP40- _FR/ Package (4) CTRL Logic (3)

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

Uninterruptible power supplies (UPS)

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

DIN Rail Power Supplies

DC POWER SUPPLY SYSTEMS

QUINT-PS/24DC/24DC/20

OUTPUT VOLTAGE 5V MAX.INPUT CURRENT 16.0A 12V 7.0A 12V 12V 24V 35.0A 28V 48V 12V 15V 24V 28V 23.0A 48V 12V 15V 24V 28V 48V 11.5A

QUINT-PS/24DC/48DC/ 5

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

QUINT-PS/24DC/24DC/10/CO

Series AM2D-Z 2 Watt DC-DC Converter

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

PEL power supplies. 24 Vdc 18 Vdc 12 Vdc SWITCHED MODE POWER SUPPLIES/ PEL SERIES

Package (3) CTRL Logic (2)

Series AM1P-Z 1 Watt DC-DC Converter

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

Indoor Linear 50W Driver SI-CU WW

Glossary/Technical appendix

QUINT-PS/24DC/24DC/10

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Uninterruptible Power Supplies

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

RWS50B RWS100B RWS150B RWS300B RWS600B

Series AM2F-Z 2 Watt DC-DC Converter

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Series AM2S-Z 2 Watt DC-DC Converter

STRIDER ESSENTIAL SERIES ST50F-ESB ST40F-ESB Power for everything you need

(typ.) (Range) ±18 330# 89 MPW MPW

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

Model Number Structure

RCD15W Series PART NUMBER STRUCTURE

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

SHORT-FORM DATA MARKINGS

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

TDK-Lambda ZWS240BP/A SPECIFICATIONS

PowerValue 11/31 T kva

PG02S Series 2W DC/DC CONVERTER, SIP-Package

DH50 SERIES. DATASHEET Rev. A

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

SOLSTART Instruction Manual

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Transcription:

AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit and reverse connection Alarm outputs for input, output and battery condition Remote On/Off for battery and power supply Controlled end of charge voltage by temperature sensor International safety approval package 3-year product warranty EMC LVD CB Scheme NKAA IEC 60950-1 UL 60950-1 EN 60950-1 UL 508 ATEX II3G EN 61558 EN 60204 TSP-TS battery temperature sensor (10 kohm NTC with 2m cable) optional This power supply provides an integrated professional battery management system to charge and monitor an external lead-acid battery. The result is a complete DC- UPS system in a compact housing with no additional parts needed. The external connected 12 V battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failures indicated by corresponding LED s and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. Models Order code TSPC 240-124 UPS * Maximum current at nominal Vout Input voltage range Output current max.* Output Power max. Low Line : 85 132 VAC High Line: 187 264 VAC 24 VDC / 12 A 240 W Back up battery 12V lead acid battery (to purchase on local market, no TRACO POWER stocking item) http://www.tracopower.com Page 1 of 7

Input Specifications Input voltage nominal ranges 100 120 / 220 240 VAC by selection switch effective ranges 85 132 / 187 264 VAC (output current derating at low input voltage see page 6) Input voltage frequency 47 63 Hz Harmonic limits EN 61000-3-2 Holdup time Inrush current Recommended circuit breaker, characteristic B or C or slow blow fuse Output Specifications 10 ms min. 40 A 16.0 A max. Output voltage / current normal mode 24.0 26.0 VDC; 10 A (12 A in boost mode) buffer mode 23.4 23.8 VDC; 10 A (12 A in boost mode) output power derating above 24 VDC 5 %/V Efficiency normal mode 88 91 % (battery charged) (load >50 % of Iout max.) buffer mode 90 92 % Regulation Input variation 1 % max. Load variation (0 100 %) 1 % max. Ripple and Noise (20MHz bandwidth) Overload protection Short circuit current Output overvoltage protection Overtemperature protection Power back immunity 100 mvp-p max. 120 140 % of Iout nom., constant current 90 % of Iout nom. (typ.), foldback 45 V switch off at overtemperature, automatic restart 35 V (40 V for 1 sec.) Power OK signal trigger threshold: 21.0 22.5 V output signal open collector 10 ma max. Max. capacitive load General Specifications unlimited Operating temperature operation in normal & buffer mode 25 C to +70 C max. derating above +60ºC : 2.5%/K normal mode boost output 25 C to +60 C max. derating above +50 C : 1.67 %/K buffer mode boost output 25ºC to +40ºC max. Storage temperature Temperature coefficient Cooling Pollution degree 2 Humidity (non condensing) Reliability, calculated MTBF at +25 C acc. to IEC 61709 Battery protection 25 C to +85 C max. 0.02 %/K convection cooling, no internal fan 95 % rel. H max. > 1.5 Mio. h against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Signals Status DC OK input, DC OK output, BAT OK all relay contact closed and LED on at status OK Contact rating 30 VDC / 1.0 A max. 60 VDC / 0.5 A max. All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 7

General Specifications (continued) Battery charging current Nominal battery voltage (at 25ºC) Battery voltage adjustment range Battery restistance test Battery test current Battery test interval (acc. to jumper setting) Battery warning Battery disconnection Battery remote Off 0.8 1.2 A 13.6 VDC (factory setting) 13.0 14.4 VDC 100mOhm min. (normal mode at 25ºC) 2.5A / 60ms typ. (normal mode at 25ºC) 15s or 10min Automatic battery temperature compensation range 15ºC 50ºC Altitude during operation 10.4 11.4 VDC (buffer mode only) 9.3 10.2 VDC (buffer mode only) disconnects battery in buffer mode (see page 6 - connector) 2000 m Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07 Industrial control equipment UL 508, CSA-C22.2 No.107 Electrical equipment for machines EN 60204-1 Electronic equipment for power installation EN 50178 Safety of transformers EN 61558-2-6, EN 61558-2-16 Control equipment for hazardous location EN 60079-15 II3G EX na IIC T4 ATEX (for IP 54 enclosure) certificate no. EPS 10 ATEX 1 269 X Certification documents www.tracopower.com/overview/tspc-ups Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 Conducted RI suppression on input EN 55011 class B, EN 55022 class B, Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kv / 8 kv criteria B Radiated RF field immunity IEC/EN 61000-4-3 10 V / m criteria A Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kv criteria B Surge immunity IEC/EN 61000-4-5 1 kv / 2 kv criteria B Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A Power frequency field immunity IEC/EN 61000-4-8 30 A / m criteria A Mains voltage dips and interruptions IEC/EN 61000-4-11 criteria B/C Environment Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 55 Hz, 1 g, 1 oct/min Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Environmental compliance Reach www.tracopower.com/overview/tspc-ups RoHS RoHS directive 2011/65/EU Connection Input output battery screw terminal (plug included) Signal & control detachable screw terminals (plugs included) All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 7

Function Specification Function Diagram: General Description This power supply is supplied by mains voltage and contains an integrated DC uninterruptible power supply feed by an external battery. It is designed to supply the applied load continuously and without interruption, even when the mains power fails. In this case, the energy is supplied from an external 12V battery to provide the required output voltage. The unit is designed to operate with lead-acid batteries Operation Before the first use, the AC input range should be set by the slide switch. During the normal operation, when the input AC voltage is present, the output DC voltage is delivered by internal AC/DC power supply. In case of power failure the internal battery discharge regulator is activated. The output voltage will be still maintained at the reduced level of 23.6V (typically at Vnom) without any interruptions. The battery discharge operation will continue until AC input voltage recovers. If the input AC voltage does not recover, the battery voltage will continue to drop, while continuously delivering the output power at required voltage level. In order to prevent the deep discharge of the battery, which can lead to battery failure, the battery is disconnected at the deep discharge threshold. The BAT OK signal will be OFF when the battery voltage is approaching the disconnection voltage level. This can enable early warning of the system. If the input AC is present at the right level, the battery is automatically charged to the set voltage level. This level is factory set for 25ºC for lead-acid batteries. The user can change this voltage by using the built-in potentiometer. The adjustment can be made only if the battery is disconnected (after initial operation) to prevent from adjustments errors. The battery test interval should be set to 10 minutes (factory settings). If the battery is operating at a different ambient temperature (not 25ºC), the user can adjust the set battery voltage to the required ambient temperature, as recommended by the battery manufacturer. After adjustments the battery should be re-connected. It is also possible to use the temperature compensation probe to automatically compensate the end battery charge voltage for any temperature changes. In this case, there is no need to change the potentiometer to compensate for a new ambient temperature. The internal state of charge of the battery is tested at regular intervals with internal current pulse. The interval is factory set to 10 minutes. It can be changed to 15s for test purposes by changing the slide switch position on the front of the unit as indicated on the label. If the battery OK signal is OFF, even after prolonged charging, the battery pack needs replacement. The buffer function (during input power failure) can be disabled remotely, and the battery is disconnected. It can be achieved by pulling the Remote ON/OFF pin to GND (with contact relay or transistor). http://www.tracopower.com Page 4 of 7

Function Specification (continued) Signals Following signals are made available as LED indicators and corresponding isolated relay contacts: AC-OK BATT-OK: DC-OUT-OK: Indicates if the input AC voltage is present. During operation outside the DC specification (overload), at low input AC levels (below nominal range) it can be OFF. It will indicate that the battery operation has started in order to maintain the output voltage at 24V level. Indicates if the battery is charged properly and has low internal resistance. During battery discharge operation this signal monitors the battery voltage. If the battery voltage approaches the disconnection voltage it is OFF. This ena bles early warnings of the system. The threshold of this signal is about 1V higher than the battery disconnection voltage. Note that if the battery signal was OFF during the normal operation (when input voltage is present) it will stay OFF during the battery discharge operation as well. Indicates that the output voltage is higher than 82 90% of the nominal output voltage. Battery When the input AC voltage is present, the TSPC-240UPS unit will automatically charge the connected battery to a set end of battery charge voltage level, factory set for 25ºC for lead-acid batteries, using a constant current charging method of 1A (typical). As the battery voltage approaches the end of battery charge voltage level, the current will decrease proportionally; this characteristic is shown in Fig 1. The user can adjust the set end of battery charge voltage level by means of the Battery Voltage Adjust potentiometer. The module also provides an input connector for a temperature compensation probe. If this probe is connected, the unit will automatically compensate the end of battery charge voltage level depending on the measured temperature. The connection of the temperature probe also negates the need to change the potentiometer to compensate for a new temperature. The battery end voltage compensation curve is shown in Fig. 2. (Applicable to factory setting of 13.6V/ 25ºC) Battery End of Charge Voltage with Temperature Sensor [V] 15.0 14.8 14.6 14.4 14.2 14.0 End of Charge Voltage 13.8 13.6 13.4 13.2 13.0-15 -10-5 0 5 10 15 20 25 30 35 40 45 50 [ºC] Figure 1 Figure 2 Battery Protection The module protects the connected battery against short circuit and overload by the means of a built in 30A fuse. This fuse is a standard 30A blade type fuse, which is accessible from the front panel of the unit for ease of replacement should the fuse be damaged during operation. It also prevents deep discharge of the battery by disconnecting the battery from the load once the voltage level of battery has dropped below a defined threshold. An early warning of this disconnection is given to the user by means of the BATT-OK signal (see chapter 2.6.2). The BATT-OK signal will switch off when the battery voltage is roughly 1V above the deep discharge threshold. http://www.tracopower.com Page 5 of 7

Function Specification (continued) Remote On/Off The TSPC-240UPS module provides a Battery Remote on/off input (2 pins on signalconnector); if this input is short circuited (switch closed in Fig. 3) the battery will be disconnected from the unit by means of an internal relay. A voltage of 0.5V or less across the Battery Remote on/off terminals will disconnect the battery from the unit. If the Battery Remote On/Off signal is set to off (short between pins) this will not affect the output of the unit in normal mode, however the battery will be disconnected, hence it will not charge. If the unit enters buffer mode while the Battery Remote On/Off signal is off, the battery will remain disconnected, hence no energy will be supplied to the load. Battery State Battery Remote On/Off Pins Voltage Connected Open Circuit 5V Disconnected Short Circuit < 0.5V Ambient temperature and power rating The module operates at temperatures between 10ºC and +60ºC, with a minimum start-up temperature of 25ºC. In normal mode the module can deliver full power up to 60ºC. The boost current of 12A is available at ambient temperatures up to 50ºC with a derating of 1.67%/ C for temperatures above 50 C, as shown in Fig. 4. In buffer mode the module can deliver full power up to 60ºC with the boost current of 12A available at ambient temperatures up to 40ºC as shown in Fig. 5. Figure 3 Figure 4 Figure 5 Output Current Derating +24V at Low Line (85-132VAC) Output Current Derating +24V at High Line (187-264VAC) 140 140 120 120 Output DC Current [%] 100 80 60 40 Nominal Boost Output DC Current [%] 100 80 60 40 Nominal Boost 20 20 0 85 90 95 100 105 110 115 120 125 130 Input [VAC] 0 180 190 200 210 220 230 240 250 260 Input [VAC] 3 Figure 2 6 Figure 7 http://www.tracopower.com Page 6 of 7

Connector Position A ACI-IN OK Bat OK DC OK Battery Remote ON/OFF Temp. Semsor 1 2 3 4 5 6 7 8 9 10 DETAIL A INPUT VOLTAGE SELECT bottom view Outline Dimensions 18.8 Signal Connector 13.9 3.8 9 12.2 23 Weight: 1400 g (49.4 oz) 13.9 INPUT VOLTAGE SELECT * Measurement from front panel to DIN Rail 114 ±1* 110 ±1 12.9 76.2 75.5 73.1 120 ±1 DIN Rail Hook DIN Rail Hook Industrial Power Supply Batter y Cont roller 15 sec Battery Test Int erval 10 min AC-O K 24-26V BATT-O K 100 ±1 Model TSPC 240-124UPS F3 0A DC-O K Battery Volt age Adjust 71.2 100-120/220-240 VAC 5.1/2.5 A 50/60 Hz N L 13,6 V/30A 24V/10A BATT-IN 6.7 8.5 OUTPUT - + - + 7.8 10 3.6 M2 Combi Head (QTY: 10) 23 9.5 M3 Combi Head (QTY: 10) 10.2 12.2 M4 Combi Head (QTY: 4) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com Rev. June 16. 2016 www.tracopower.com Page 7 of 7