NDS6 Series Isolated 6W Wide Input Single & Dual Output DC/DC Converters

Similar documents
NCS6 Series Isolated 6W 4:1 Input Single & Dual Output DC/DC Converters

NCS12 Series Isolated 12W 4:1 Input Single & Dual Output DC/DC Converters

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

NCS6 Series Isolated 6W 4:1 Input Single Output DC/DC Converters

NMH Series Isolated 2W Dual Output DC/DC Converters

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

NKE Series. Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

MEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

MEE1 Series Isolated 1W Single Output DC/DC Converters

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

SELECTION GUIDE. Nominal Input Voltage. Output Current. Output Voltage. Reflected ripple current

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

MEJ2 Series 5.2kVDC Isolated 2W DC/DC Converters

NTA Series Isolated 1W Dual Output SM DC/DC Converters

NMA 5V, 12V & 15V Series Isolated 1W Dual Output DC/DC Converters

NXE1 Series Isolated 1W Single Output SM DC/DC Converters

MEV3 Series 3kVDC Isolated 3W Single Output DC/DC Converters

SELECTION GUIDE. Nominal Input Voltage. Voltage Order Code1. Output

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

NXJ2 Series Isolated 2W Single Output SM DC-DC Converters

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85

NXE1 Series Isolated 1W Single Output SM DC-DC Converters

NXJ1 Series Isolated 1W Single Output SM DC-DC Converters

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code 1. V V ma

NXE2 Series Isolated 2W Single Output SM DC-DC Converters

NME 5V & 12V Series Isolated 1W Single Output DC/DC Converters

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W

MGJ1 Series 5.7kVDC Isolated 1W SM Gate Drive DC/DC Converters

NMJ Series 5.2kVDC Isolated 1W DC-DC Converters

SELECTION GUIDE. Order code B0303NXT-1W B0305NXT-1W B0309NXT-1W

NME 5V & 12V SERIES. Technical enquiries tel: +44 (0) Isolated 1W Single Output DC/DC Converters

SELECTION GUIDE. Order code Voltage(VDC) NTE0303XMC NTE0305XMC

MGJ6 14mm Series 10.2kVDC Isolated 6W Gate Drive SM DC/DC Converters

OBSOLETE SELECTION GUIDE 1. Recommended alternative: OKY-T/10-W5P-C >> click here to download the data sheet

LSS-T/10-W12. Adjustable Output 10 Amp SIP-mount DC/DC Converter. PRODUCT OVERVIEW FEATURES

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

(typ.) (Range) ±18 330# 89 MPW MPW

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

PG02S Series 2W DC/DC CONVERTER, SIP-Package

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

S24SP series 40W Single Output DC/DC Converter

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

2W, Low Cost DIP, Dual Output DC/DC Converters

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

DH50 SERIES. DATASHEET Rev. A

(typ.) (Range) Load

Application Note TES 1 Series

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

UNR Series Single Output, Non-Isolated, 3.3V 8-40 Watt, DC/DC Converters

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

S24SP15004 series 60W Single Output DC/DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

UWR Models. Single Output, High-Density, 6 Amp/15 Watt DC/DC Converters.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

UL Certified RP30-FW

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

UNS Series Non-Isolated, 3.3V & 5V, 3A DC/DC Converters

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

RCD15W Series PART NUMBER STRUCTURE

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DCMCW60 SERIES FEATURES

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

Features. Unregulated Converters. 2 Watt SIP7 Single and Dual Output RKZE. RKZE- _/_ Protection (4) Isolation Option (3) Single or Dual

Sixteenth brick format 4:1 input voltage range 2.25kV basic isolation Remote ON/OFF and trim pins UVLO, OTP, OVP, OCP and SCP Efficiency up to 91%

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

RUZ- _/_ Protection (3) Isolation Option (4)

North America Asia-Pacific Europe, Middle East

RP40- _FR/ Package (4) CTRL Logic (3)

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Series AM1P-Z 1 Watt DC-DC Converter

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

Transcription:

www.murata-ps.com NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters FEATURES UL 9 recognized RoHS compliant : Wide range voltage input Operating temperature range C to 8 C Short circuit protection. Typical load regulation.kvdc Isolation Hi-Pot Test V Nominal input Single & dual outputs Power density.9w/cm Optional remote On/Off UL 9V- Package materials No electrolytic capacitors Low noise PRODUCT OVERVIEW The NDS series of DC/DC converters offer single and dual output voltages from an input voltage range of 8-V. The NDS is housed in an industry standard package with a standard pinout. The NDS is packaged in a metal case for improved EMI shielding and is also encapsulated for superior thermal performance. Versions with optional remote on/off control pin are also available. Applications include telecommunications, battery powered systems, process control and distributed power systems. SELECTION GUIDE Input Voltage Order Code Nom. Output Voltage Output Current Min. ± Input Current Shut Down Ripple & Noise Efficiency V V A A ma ma ma mv p-p khrs NDSDC ± ±. ±.. 8 8 NDSDC ± ±. ±. 9. 8 8 NDSDC ± ±. ±. 9. 8 8 NDSSC... 8 8 NDSSC... 9. 8 8 NDSSC.. 9. 8 8 Min. Typ. MTTF INPUT CHARACTERISTICS Voltage range All NDSD & NDSS types 8 V Reflected ripple current All NDSD & NDSS types ma p-p OUTPUT CHARACTERISTICS Rated power W Positive & negative except NDSD negative ± Voltage set point accuracy output NDSD negative output ± Line regulation regulation Cross regulation Low line to high line total load to total load voltage change on negative output when positive load varies from. (.W) to. (.W) with negative load fixed at (W) Positive outputs.. Negative outputs.. V outputs.. V & V outputs. V V & V ISOLATION CHARACTERISTICS Isolation test voltage Flash tested for second VDC Resistance Viso = kvdc GΩ Capacitance pf ABSOLUTE MAXIMUM RATINGS Short-circuit protection Continuous Internal power dissipation.w Lead temperature.mm from case for seconds (to JEDEC JESD-B ISS C) C Minimum output load for specification of rated load on each output Control pin input voltage ±8V Input voltage, NDS V input types V Calculated using MIL-HDBK-F with nominal input voltage at full load. To order with optional control pin, prefix C with E. For example NDSDEC. Operation below minimum load may cause increased output ripple. All specifications typical at TA= C, nominal input voltage and rated output current unless otherwise specified. For full details go to www.murata-ps.com/rohs KDC_NDS.E Page of

NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters GENERAL CHARACTERISTICS Switching frequency khz Control pin input Module ON (or pin unconnected). V ma Module OFF.8 V. ma TEMPERATURE CHARACTERISTICS Operation - 8 Storage - Case temperature rise above ambient, Nom VIN, Still Air, V 9 C V & V Thermal shutdown Case Temperature APPLICATION NOTES Control Pin This provides an OFF function, which puts the converter into a low power mode, when the voltage applied to the pin is less than.8v. When the pin is high or un-connected, the converter is on. NDSD Cross Regulation regulation is at its best when the positive and negative loads are balanced. When the loads are asymmetric, the negative output is not as tightly regulated as the positive output. To meet datasheet specification, a minimum load of of output load current is required on each output. The NDSD can be used with much lighter loading but the negative output voltage may rise above maximum datasheet specification. Output Capacitors The NDS series does not require output capacitors to meet datasheet specification. To meet datasheet specification, output capacitance should not exceed: Output Voltage (V) Output Capacitance (μf) TECHNICAL NOTES ISOLATION VOLTAGE Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand Voltage & Isolation Test Voltage are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NDS series of DC/DC converters are all production tested at their stated isolation voltage. This is.kvdc for second. A question commonly asked is, What is the continuous voltage that can be applied across the part in normal operation? The NDS has been recognized by Underwriters Laboratory for functional isolation. Both input and output should normally be maintained within SELV limits i.e. less than.v peak, or VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NDS series has an ER ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. KDC_NDS.E Page of

NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters SAFETY APPROVAL The NDS series has been recognised by Underwriters Laboratory (UL) to UL 9 for functional insulation in a maximum ambient temperature of 8ºC and/or case temperature limit of ºC (case temperature measured on the face opposite the pins). File number E applies. Note: This series gained UL 9 recognition for products manufactured on or after datecode G8, any NDS parts manufactured before this date code should not be considered UL 9 recognized. Any NDS that is UL recognized will be printed with the UL logo. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of ºC for seconds. The pin termination finish on this product series is a Gold flash (.-. micron) over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C C C R R T RLOAD μf XR multilayer ceramic capacitor, voltage rating to be a minimum of times the output voltage of the DC/DC converter μf tantalum capacitor, voltage rating to be a minimum of. times the output voltage of the DC/DC converter with an ESR of less than mω at khz nf multilayer ceramic capacitor, general purpose Ω resistor, carbon film, +/- tolerance Ω BNC termination T of the coax cable through a ferrite toroid Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by to obtain the specified values. Differential Mode Noise Test Schematic SUPPLY DC/DC Converter + + Input Output C C C R T R OSCILLOSCOPE Y INPUT - - R LOAD EFFICIENCY VS LOAD NDS V Input, Dual Output Efficiency () 9 8 V V V 8 9 () NDS V Input, Single Output 9 8 Efficiency () V V 8 9 () V KDC_NDS.E Page of

NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters TEMPERATURE DERATING NDSDC NDSDC lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm - - - - 8 - - - - 8 NDSDC NDSSC lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm lfm - - - - 8 - - - - 8 NDSSC lfm lfm lfm lfm lfm lfm - - - - 8 NDSSC lfm lfm lfm lfm lfm lfm - - - - 8 KDC_NDS.E Page of

NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters EMC FILTERING AND SPECTRA FILTERING The module includes a basic level of filtering, typically sufficient to meet EN Curve A Quasi-Peak EMC limit, as shown in the following plots. NDSSC NDSSC 9 8 9 8 NDSSC NDSDC 9 8 9 8 NDSDC NDSDC 9 8 9 8 KDC_NDS.E Page of

NDS Series Isolated W Wide Input Single & Dual Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS.8 (.) NDSxxxxxC XYYWW. (.) Pin Function Single Dual -VIN -VIN -VIN -VIN * On/Off On/Off 9 No pin OV N/C -VOUT +VOUT +VOUT -VOUT OV +VIN +VIN +VIN +VIN * Optional pin TUBE OUTLINE DIMENSIONS.9 (.).±. (.±.). (.).-. (.-.). (.) 8. (.). (.9). (.8). (.) * 9. (.8).9 (.). (.8) Tube length (.) All dimensions in mm ±.mm (inches ±.). Quantity: RECOMMENDED FOOTPRINT DETAILS. (.) 8 HOLES.9 (.) Ø. (.). (.).8 (.) Weight:.g Typ. * All dimensions in mm (inches) ±. (.) except pin to pin tolerance ±. (.). All pins on a. (.) pitch and within. (.) of true position. The copper case is connected to the output (-VOUT) pin. Care is needed in the design of this circuit board on which the converter is mounted. Top side tracks must not contact the edge of the case on the underside of the unit. Please note that from onwards, you may receive either a blue or a black case.. (.) * Optional pin All dimensions in mm ±.mm (inches ±.). Murata Power Solutions, Inc. Cabot Boulevard, Mansfield, MA 8- U.S.A. ISO 9 and REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. Murata Power Solutions, Inc. KDC_NDS.E Page of