Fiber Connector Shelf (CCS)

Similar documents
Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Environmental Distribution Center (EDC-06P-NH)

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

8400 Series Fiber Distribution System

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

INSTALLATION INSTRUCTIONS

Universal Splice Tray Installation Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Opticom Rack Mount Fiber Enclosures

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Fiber Optic Splice Module

PanView iq (PViQ) Fiber Tray

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

FL2000 Termination/Splice Panels User Manual

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

FIBER CONNECTOR SAFETY WARNINGS

C Power Connection Kit

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Instructions for Use - Opt-X 1000i Enclosure

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

INSTALLATION INSTRUCTIONS

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Fiber Splice Panel Rack Mount User Manual

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

STANDARD STEEL PLOW BLADE ASSEMBLY INSTRUCTIONS

CS Fiber Optic Splice Case. Instruction

LEXUS GX TOWING HITCH Preparation

FOSC-400A4 INSTALLATION INSTRUCTION

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

INSTALLATION INSTRUCTIONS

COYOTE STP (Service Termination Point)

INSTALLATION INSTRUCTIONS

Fiber optic splice closure

Installation Instructions Part Number

COYOTE STP (Service Termination Point)

VEHICLE SPECIFIC ELECTRICAL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SPORT/UTILITY BLADE ASSEMBLY INSTRUCTIONS

LSW Connector Module User Manual

29048, 29049, 29050, 29051, 29052, 29053, 29054,

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

3M Fiber Dome Closure FDC 10

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Installing the Switch

(31 ) ZEON CONTROL PACK RELOCATION KIT

INSTALLATION INSTRUCTIONS

(31 ) ZEON CONTROL PACK RELOCATION KIT

12-Inch Hybrid Fiber Access Terminal Installation Instructions

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

INSTALLATION INSTRUCTIONS

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Air Conditioner for M915 A0/A1 Truck

29048, 29049, 29050, 29051, 29052, 20953, 29054,

INSTALLATION INSTRUCTIONS

Signal Mirror Installation Instructions Standard West Coast Mirror

INSTALLATION INSTRUCTIONS

Copyright 2004 Alcatel. All rights reserved.

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

Part# JL AIR IT UP 4 Tire On Board Air Delivery System. (Requires External Air Source)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DIN RAIL FIBER ENCLOSURE

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

INSTALLATION INSTRUCTIONS

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

FOSC-100 B/H FOSC-100 B2/H

P.O. Box 529 Rockland, Maine August 1, 2006 HEADGEAR KIT. MC Series. Installation Instructions

Verizon FTTP Tool Kits and Accessories An Evolant Solutions Product

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM

49663, 49664, Wiring Conversion Kits. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Zeon Control Pack Relocation Kit 78 Cable Length

Carousel Unit User Manual Replacing the Check Stand Motor

WARNING WARNING CAUTION. Warnings and Cautions MOVING PARTS ENTANGLEMENT HAZARD MOVING PARTS ENTANGLEMENT HAZARD CHEMICAL AND FIRE HAZARD

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

ELECTRICAL SYSTEM UPGRADE

29048, 29049, 29050, 29051, 29052, 29053, 29054,

INSTALLATION INSTRUCTIONS

Transcription:

Corning Cable Systems Standard Recommended Procedure (SRP) 003-595 Issue 3, May 2007 Page 1 of 6 Fiber Connector Shelf (CCS) Table of Contents 1. General... 1 2. Precautions... 1 3. Components... 2 4. Tools and Equipment... 3 5. Cable Installation... 3 6. Grounding... 4 7. Splicing... 4 8. Jumpers... 4 9. Specifications... 5 CCS-01U CCS-01U (shown with optional CCS-LBL-PNL) KPA-1184 Figure 1 1. General 1.1 This document describes the recommended procedures for the installation of the Fiber Connector Shelf (CCS-01U). The CCS-01U unit is a sliding tray inside a housing that accommodates a splice tray with space available underneath the splice tray for cable slack. The optional CCS-LBL- PNL (ordered separately) is a jumper routing shelf that provides jumper slack storage and a label for recording port assignments. Connectors are installed in adapters that are secured to two removable LANscape -compatible panels. The unit houses two incoming cables. Additional splice holders are supplied that allow splicing in the unit. The unit can be mounted to a standard 19-inch or a 23-inch utility rack. 1.2 Contact your customer service representative to purchase accessories that are sold separately. 1.3 This document is being reissued to add the logo indicating this product is RoHS compliant. NOTE: Before you begin your installation, make sure you understand how the unit is to be installed, where cable will enter the unit, where it will be placed on the utility rack, how jumpers will be routed, and other details of the installation plan. 2. Precautions 2.1 Laser Handling Precautions WARNING: Never look directly into the end of a fiber that may be carrying laser light. Laser light may be invisible and can damage your eyes. Viewing it directly does not cause pain. The iris of the eye will not close involuntarily as when viewing a bright light. Consequently, serious damage to the retina of the eye is possible. Should accidental eye exposure to laser light be suspected, arrange for an eye examination immediately. WARNING: DO NOT use magnifiers in the presence of laser radiation. Diffused laser light can cause eye damage if focused with optical instruments. Should accidental eye exposure be suspected, arrange for an eye examination immediately. 2.2 Safety Precautions CAUTION: The wearing of safety glasses to protect the eyes from accidental injury is strongly recommended when handling chemicals and cutting fiber. Pieces of glass fiber are very sharp and can damage the cornea easily. p/n 003-595

Page 2 SRP 003-595 Issue 3 CAUTION:The wearing of safety gloves to protect hands from accidental injury is strongly recommended when using sharp instruments. 2.3 Glass Fiber Precautions WARNING: Cleaved glass fibers are very sharp and can pierce the skin easily. Do not let cut pieces of fiber stick to your clothing or drop in the work area where they can cause injury later. Use tweezers to pick up cut or broken pieces of the glass fibers and place them on a loop of tape kept for that purpose alone. Good housekeeping is very important. 2.4 Cable Handling Precautions NOTE: Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the cable specification sheet for the cable you are installing. Do not bend the cable more sharply than the minimum recommended bend radius. Do not apply more pulling force to the cable than specified. Do not crush the cable or allow it to kink. Doing so may cause damage that can alter the transmission characteristics of the cable the cable may have to be replaced. 3. Components Components are illustrated in Figure 2. Radius Guides Strain-relief Brackets Rack Mounting Brackets (Secure to 19-inch rack using provided screws.) Hook-and-Loop Strap Lance (to secure splice tray) Cable Tie Lance 23-inch Rack Bracket (Secure behind 19-inch mounting bracket before attaching to the 23-inch rack using screws provided.) Slide Shelf KPA-1185 Connector Panels (Secure using plunger fasteners.) Jumper Routing Tray (Optional) (p/n CCS-LBL-PNL) (Mount to underside of housing using provided screws.) Plunger Pull the plunger out all the way to collapse the fingers. Position the plunger into the mounting hole in the housing. Fingers Push the plunger in completely to expand the fingers and secure the panel to the housing. Figure 2

Issue 3 SRP 003-595 Page 3 4. Tools and Equipment The tools required to complete this installation include: Phillips-head screwdriver Flat-blade screwdriver 5 /16-in. nut driver Utility knife Tape Measure Needle-nose pliers 5. Cable Installation 5.1 Determine the location for cable entry into the unit and remove the appropriate grommet. Pierce a hole as instructed in Figure 3. Grommets must fit tightly to prevent intrusion of insects, water, dirt or foreign particles. A knife may cut all the way through the grommet and cutters may cut a hole that is too large for a tight fit. Central Member Length: 5 cm (2 inches) Buffer Tube Length: 224 cm (88 inches) KPA-1187 Yarn Length: 5 cm (2 inches) Fiber with Buffer Tube Removed: Length depends on tray and splicing method. Figure 4 5.5 Direct Connectorization. If the cable you are installing must be connectorized, do so at this time per connector manufacturer instructions. 5.6 Secure the cable to the strain-relief bracket using cable ties (Figure 5). U-Washer Round Washer Pierce the grommet using a sharp pencil or a pair of needle-nose pliers. Do not use a knife or cutters. Central Member Yarn KPA-1186 KPA-1188 Figure 5 Figure 3 5.2 Feed the cable through the pierced grommet. Allow extra loop of cable for a service loop when the tray is fully extended. 5.3 Outside plant (loose-tube) fiber optic cable can be installed using Corning Cable Systems Buffer Tube Fan-out (BTF) Kits (purchased separately). After following the instructions provided with the kit, route the fibers and use cable ties to secure the fan-out bodies to the lance on the shelf. 5.4 Remove cable sheath to the length illustrated in Figure 4. When installing BTF kits, leave 57 in. of fiber with the buffer tube removed. 5.7 Strain-relieve central members as needed: 1) Use the 5 /16-in. nut driver to remove the strainrelief bracket from the cabinet. 2) Attach the cable to the bracket (with cable ties in two places) on the side of the mounting flange. Make sure the location on the bracket you choose for the cable ties will line up with the cable entry hole. 3) Install a U-shaped washer assembly to the bracket. 4) Wrap the aramid yarn, if present, clockwise under the U-shaped washer and position the central member between the U-shaped washer and the round washer.

Page 4 SRP 003-595 Issue 3 IMPORTANT: If the central member is metallic, make sure a half inch of insulation is stripped off and the central member makes metal-to-metal contact with the washers. 5) Trim the yarn. Leave 1 /4-in. of central member. 6) Secure the bracket to the housing with the nylon nuts provided. Tighten with a 5 /16-in. nut driver. 7) Reinstall the cable entry grommet. 5.8 Carefully install the connectors into the adapters on the back side of the connector panel and tighten. Obey the following precautions in order not to damage the surface of the connector and make it unusable. Do not press heavily on it as you clean. Do not OVERTIGHTEN. Do not allow the connector body (ferrule) to turn as you screw it into place. This causes the surfaces to grind against each other. Do not force the connector into the receptacle. If the connector does not fit easily into the receptacle, back it out and retighten. 5.9 Secure buffer tubes to the lance on the shelf using a cable tie (Figure 6). 6. Grounding 6.1 Metallic Central Members. Place the eye of a ground wire (#6 AWG, purchased separately in an appropriate length from any electrical supply store) under the U-shaped washer or under the flat washer. Then either: Attach the other end of the ground wire to the equipment rack (be sure to remove any paint or anodization so good contact is made). Ground the equipment rack to the primary building ground. Or, attach the other end of the ground wire to a rack mounted grounding bus bar, which is itself grounded to the primary building ground. IMPORTANT: The ground strap must have an electrical path to the central member. 6.2 Armor Grounding. Order p/n FDC-CABLE-GRND and follow the provided instructions to attach the grounding lug to the cable armor. Then, run a ground wire (#6 AWG, purchased separately in an appropriate length from any electrical supply store) from the lug to the primary building ground via one of the methods mentioned in Section 6.1. 7. Splicing 7.1 A pigtail is cable with connectors on one end; the other end of the pigtail is terminated in the splice tray. Install connectorized end into the connector planels and route to an appropriate splicing area. 7.2 Route buffer tubes and pigtails into the shelf as shown in Figure 6. 7.3 Splice fibers according to the instructions for your splicing method. 7.4 If you are splicing fibers into the supplied selfadhesive splice holders: a) Remove and discard the hook-and-loop strap. b) Clean the surface of the housing in the area between the radius guides. c) Secure the splice holders to the floor of the shelf between the two routing guides. d) Install splices into holder. 7.5 If you are splicing fibers into the splice tray (purchased separately): a) Follow the instructions provided with the splice tray. b) Secure the splice tray to the unit using the hookand-loop strap. 8. Jumpers A jumper is cable with connectors on both ends. Install jumpers (patch cords) into adapters in front of the connector panel as instructed on planning diagrams.

Issue 3 SRP 003-595 Page 5 Splice Tray Hook-and-loop Strap KPA-1189 Figure 6 9. Specifications The CCS-01U unit is 55 cm (21-3 /4 in.) deep with the slide shelf fully extended. 44cm (17-3/8 inches) 31cm (12-1/4 inches) 4.5cm 1-3/4 inches) KPA-1190 Figure 7

Page 6 SRP 003-595 Issue 3 Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 1-800-743-2671 FAX +1-8 28-325-5060 International +1-828-901-5000 http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems products without prior notification. Lanscape is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 2002-2003, 2007 Corning Cable Systems. All rights reserved. p/n 003-595 / May 2007