CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

Similar documents
CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidGate Control Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidVertic Vertical Vortex Valve

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. *

pneumatic outflow control

SITRANS F M flow sensors 711/A and 711/911E

Insertion magnetic inductive flowmeter

Filter Type PR-BW 100. Filtration

Sleeve Valves Energy Dissipaters

Best Practice Variable Speed Pump Systems

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

INSTALLATION AND OPERATION

Marsh McBirney Flo-Dar

C h e c k M a t e I n l i n e C h e c k V a l v e

Figure 1.1. From left to right: PVC, GRP and AISI 316L. Filter type Filter body material Max pressure Max temperature BSP PVC 150 psig 104 F, 40 C

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

Technical Guide No. 7. Dimensioning of a Drive system

MONOVAR is the energy dissipating valve.

Fundamental Training. Flow Con t

Hydraulic Design of Navigation Locks

JUNG PUMPEN MULTICUT SEWAGE PUMPS

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

WATERFLUX 3000 Technical Datasheet

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

COMPACT PNEUMATIC ACTUATOR 4x4

Automatic Self-Cleaning Strainer/Filter Systems

Series 774 Automatic Skid Package

Applications for energy storage flywheels in vehicles of Deutsche Bahn AG

유량계전문제조업체. Electro Magnetic FLOWMETER

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Electromagnetic Flow Monitor magphant

EXPERIMENT 13 QUALITATIVE STUDY OF INDUCED EMF

Pneumatics, Automation & Control Solutions

Paddle-wheel flow controller with optical principle for On/Off control

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

TIDALFLUX 2300 F Quick Start

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

ELECTRIC & HYDRAULIC VALVES

FLOW RATE STATIC BALANCING Valves for radiators

OPTIFLUX 6000 Technical Datasheet

Our products for water transmission Double-eccentric butterfly valves Air valves Non-return valves Connection systems

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

Electronic Control Valves

STEEMCO-MAS Flowmeter for Steam

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

The Discussion of this exercise covers the following points:

A Practical Guide to Free Energy Devices

PROCESSAUTOMATIC MAGNETIC FLOWMETER

Series description: Wilo-DrainLift KH 32

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

M3770: SOLENOID CONTROLLED / ELECTRICALLY POSITIONED VALVE - STEP BY STEP VALVE

Automatic Self-Cleaning Strainer/Filter Systems

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Comparison between Fluid Viscous Dampers and Friction Damper Devices. Fluid Viscous Dampers (FVD) Friction Damper Device (FDD) Working principle:

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

three different ways, so it is important to be aware of how flow is to be specified

Input, Control and Processing elements

Magnetic Inductive Flow

Magnetic Inductive Flowmeter EP / UMF2 (B)

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

Full Profile Insertion

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

THE IDLE CIRCUIT AND THE PROGRESSION. We have seen how in a "basic"

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

PRESSURE REDUCING VALVE

September Leopold Sludge Collection Equipment

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

HTX-HTH SEPARATORS I&O MANUAL

STEEMCO Flowmeter for Steam

PRESSURE REDUCING VALVE

Components of Hydronic Systems

Regular inspections are recommended to ensure that the system is functioning as designed.

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

MODEL 200 MULTI-JET FLOW METER

CM2-MGG User s Manual

Automatic control valves XLC 300 and 400 series

2.007 Design and Manufacturing I, Spring 2013 EXAM #2

Fundamentals of Natural Gas Measurement

Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

VDF (Vortex Dynamic Filter) Instruction Manual CL-MR-series models

Operating manual Separator

THE CARBURETOR: THE ADDITIONAL SYSTEMS

Low-Cost Pipeline Flow Meter

CONTRIBUTION TO THE CINEMATIC AND DYNAMIC STUDIES OF HYDRAULIC RADIAL PISTON MOTORS.

CHAPTER 7 PUMPING SYSTEM DESIGN

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Typical Feed Water Heater Isolation System.

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

Filter Type PR-BW 100-FC. Filtration

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Transcription:

CSO/STORMWATER MANAGEMENT HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

HYDROVEX FLUIDMID FLOW MONITORING & REGULATING STATION WITH SIPHON (TYPE G) APPLICATION The HYDROVEX FluidMID flow monitoring and regulating station with siphon (Type G) is made especially for wastewater applications. It operates with a traditional flow monitoring system and is designed with a siphon shaped pipe. The FluidMIDg is particularly appropriate for precise and continuous flow monitoring, recording and regulating flows in sewer networks and at Wastewater Treatment Facilities. The FluidMIDg unit can be applied only to measure flows or to fully regulate the flow with a piloted knife gate valve. Based on the high performances and proven reliability of this system, the FluidMIDg is particularly suited for large retention basins, for Equalization Tanks close to pumping stations or Wastewater Treatment Plants, for sewer system s Real Time Control, for billing flow contributions of satellite communities to a regional sewer system, for exact monitoring of flows of arriving or leaving Wastewater Treatment Plants, etc. ADVANTAGES The hydraulic performances of the HYDROVEX FluidMIDg flow regulator that uses a siphon-type pipe, were the subject of many a research and optimization efforts in a UFT laboratory, in Germany. The optimization goals were: smallest possible headloss in the system, use of the shortest sections of pipes for flow tranquillization, create a homogeneous profile for the flow pattern, build self-cleaning capacity, prevention of upstream air siphons reaching the pipe, lowest installed machine profile. The original laboratory test conclusions were subsequently confirmed by numerous successful references. The HYDROVEX FluidMIDg flow monitoring and regulating stations have the following advantages: Uninterrupted flow monitoring, even during low flow conditions Precise flow monitoring provided by commercially available magnetic flowmeters Low installation profile Special inlet mouthpiece, causing low headloss and reducing nominal diameter and improving self cleaning Forced cleaning available for important deposition conditions Flow monitoring system covering all hydraulic conditions OPERATION & INSTALLATION The operation principle of inductive flowmeters is based on Faraday's law of electromagnetic induction. When a water flow passes in the monitoring pipe subject to a perpendicular magnetic field, an electric current is induced between two electrodes located opposite one another in the inner wall of the pipe. This tension is proportional to the flow rate in the central portion of the pipe. Measuring tube with motorized valve and pumps: 1 Magnetic flowmeter 2 Pipe, stilling length 3 Manual valve 4 Incoming mouthpiece 5 Self adjusting collar for unit dismantling 6 Motor piloted valve to regulate the flow 7 Angled siphon pipe 8 Bypass pipe and wall thimble 9 Bypass valve 10 Dismantling collar on bypass 11 Bypass extension pipe 12 Pressure head recorder (optional) or cleaning orifice 13 Booster pump (optional) 14 Above-ground control panel 15 PLC system, monitoring, recording and instrument adjustments 16 Sump pump Figure 1: Parts of a Hydrovex FluidMID Flow Monitoring and regulating station with siphon (Type G)

For monitoring station application only, the HYDROVEX FluidMIDg requires a two-room chamber arrangement, made of the instrument chamber with all the pipes and equipment, and a downstream pressure release chamber. Applications involving flow regulation, require the installation of an upstream chamber for maintenance access. Please see cover drawing for arrangement. The magnetic flowmeter, valves and accessories are always based on a dry well installation. In siphon configuration, the flowmeter is always completely filled with water, even during low flow conditions. Therefore the FluidMIDg is always ready to operate. Even backflows can be measured by the magnetic flowmeter. Lowering the monitoring pipe inlet in the upstream access chamber s sump creates the station s siphon. The lowered elevation is called dimension of the siphon. The outlet end of the station is slanted upwards, right after the flowmeter and flow regulating section. The special inlet mouthpiece creates improved hydraulic conditions that lower headloss and enhance self-cleaning capacities. The absence of the special inlet mouthpiece can lead to the creation of surface swirls that will suck air into the unit pipe section. The presence of an air swirl in the pipe can affect the capacity of the unit to precisely measure flow conditions. Consequently, installation of the special inlet mouthpiece reduces only the price of the station (by making it one diameter smaller or more) and its construction, but at the same time increases the flowrate in the monitoring pipe. The overall monitoring performances are more precise and the self-clearing of the system is reinforced. Modeling has shown that siphon pipe operation is often jeopardized by deposition of solids in the lower section of the pipe, where the magnetic flowmeter is located. The inlet to the system is inside a pipe section and not in a channel on purpose. The open diameter remains small and the dynamic shearing forces of the water large. As an option, we can supply an automatic cleaning system operating on a timer. This booster pump generates a swirling jet of water inside the FluidMIDg pipe section (see Stress section). In parallel with the monitoring pipe, there should always be a by-pass. This is required for maintenance purposes. Floating debris can accumulate in the inlet mouthpiece of the monitoring pipe, for example: balls, pieces of polystyrene, etc. These debris need to be removed and can sometimes require the opening of the bypass valve. The instrument chamber should also include a sump equipped with an automatic sump pump that empties the chamber. This pump can prevent instrument submergence, motors getting wet, etc. by water accumulating in the instrument chamber. Figure 2: Operation of a HYDROVEX FluidMIDg for flow monitoring only and flow monitoring with regulation. FLOW CONFIGURATION The HYDROVEX FluidMIDg applies to two distinct types of operation: the flow monitoring function alone and the combined function of monitoring and regulating the flow. For flow monitoring alone, the motorized valve is not required. The flow characteristics are related only to the headloss at the inlet of the pipe, friction in the monitoring pipe as well as outlet headlosses. The relevant flow curve is slightly S shaped (Figure 2). The headloss is very small, based on the hydraulic coefficient of the flow-monitoring pipe. In general, we assume a hydraulic coefficient of µ = 0,75. For combined flow monitoring and flow regulation, the motorized valve regulates the flow by closing the open flow area. For flows up to design flow, the knife gate remains entirely open. If the design flow Q b is exceeded, the valve starts to control motorized flow and keeps, by correction of the opening, constant flow. A digital and programmable PLC system independently maintains a constant adjustment to maintain the design flow, with a minimum of valve movements. The optimal adjustment program of the PLC is proprietary. Figure 2 shows the vertical flow curves that the unit can maintain, depending on the design flow. The head, H, indicates the upstream water level required to reach design flow.

HYDRAULIC BEHAVIOR The nominal pipe diameter DN of the monitoring pipe is defined according to the flow of Q b. For quick selections, please see Table 1. Q b is the regulated flow; Q 0 is the base flow when selecting a monitoring station without regulation function. Each installation requires hydraulic dimensioning. This is particularly true for projects involving small slopes or when the application is complicated. The design head and limitations for minimum and maximum flows must be defined in advance for all conditions upstream and downstream from the siphon system. These calculations are complicated and very precise monitoring pipe hydraulic data must be available. We will supply this full calculation upon request (see calculation sheet ). Nominal Diameter DN 100 (4 ) 150 (6 ) 200 (8 ) 250 (10 ) 300 (12 ) 350 (14 ) 400 (16 ) 500 (20 ) Flow Monitoring and Regulation Q bmin 2.0 (0.071) 4.4 (0.15) 8.0 (0.28) 12.0 (0.42) 18.0 (0.63) 24.0 (0.85) 31.0 (1.1) 49.0 (1.73) Q bmax 13 (0.45) 34 (1.2) 66 (2.3) 124 (4.4) 196 (6.9) 288 (10.2) 402 (14.2) 702 (24.7) Q 0 10.5 (0.37) 28 (1.0) 55 (1.9) 103 (3.6) 163 (5.7) 240 (8.5) 335 (11.8) 585 (20.6) Table 1 : Operation for flow monitoring and monitoring / regulation of a Hydrovex FluidMIDg Tangential constraints and auxiliary flushing system The tangential load in a pipe is the force applied per unit of surface area. The larger the tangential load, the smaller the possibility of sediments building up in the monitoring pipe. If the tangential load is very low in dry time conditions or during the night, there are three possibilities of clearing: a. Clearing out by hand: This process is sufficient for systems where water flows are always important. The idea is to occasionally close the motorized valve or manual valve, thus creating water retention upstream that will, upon reopening, flush the pipe by natural pressure. The pressure jet that passes under the valve can push debris, up to fist-size stones, towards the outlet of the monitoring pipe. b. Automatic rinsing program: This is the FluidMIDg s normal way to operate. By action of a preset timer, activated only during dry weather conditions, the motorized valve is closed and the water is stored upstream. A pressure sensor in front of the flow meter regulates the flushing process to avoid useless overflows. c. Automatic rinsing forced by intermediate pump: We recommend this system for very difficult cases, such as: very small dry time flows or very bad flow conditions involving backflow from downstream. Upon signal from a clock, and during dry time conditions, the pump sucks water close to the surface and beside the inlet mouthpiece, and projects it in a high velocity tangential jet towards the downstream side of the pipe system. Under the powerful spiral jet, the sediments are evacuated from the siphon and the electrodes of the flow meter cleaned at the same time. For the duration of the booster pump flushing, the monitoring function of the FluidMIDg is stopped. MATERIAL All parts installed in the flow-monitoring unit are made of corrosion resistant materials. The inlet mouthpiece is always made of stainless steel. For all pipes diameters, we use stainless steel. The knife gate valves are specially modified for the application by John Meunier Inc.

INSTALLATION DIMENSIONS Standard installation dimensions for FluidMIDg stations are indicated on a separate chart. In certain cases, we can modify our standard design once we get full approval from our Engineering Department. However; deviation must always be minor, to prevent changing the hydraulic behavior of the FluidMIDg. We can also supply custom-built AUTOCAD drawings upon special request. ELECTRIC DRIVES All the instrument modules and motor control systems are located in a surface control panel. This panel can be located either in a small building or directly outside, close to the FluidMIDg station. It should never be installed underground for explosion proof regulation limitations. It always includes enough space for all meters, heating, lighting and a mounting frame. On this mounting frame, the operating modules and indications are installed. A PLC module controls the complete installation. The set points can be adjusted manually or by a remote system, if SCADA or the like is available. The flow recordings can be carried out made by printers, linear recorder, Datalogger or recorder with needles. SPECIFICATIONS The content of the HYDROVEX FluidMIDg monitoring and flow regulating station is defined one site after the other. We can supply technical specifications of a selected unit at all times. John Meunier Inc. ISO 9001 : 2000 Head Office 4105 Sartelon Saint-Laurent (Quebec) Canada H4S 2B3 Tel.: 514-334-7230 www.johnmeunier.com Fax: 514-334-5070 cso@johnmeunier.com Ontario Office 2000 Argentia Road, Plaza 4, Unit 430 Mississauga (Ontario) Canada L5N 1W1 Tel.: 905-286-4846 www.johnmeunier.com Fax: 905-286-0488 ontario@johnmeunier.com USA Office 2209 Menlo Avenue Glenside, PA USA 19038 Tel.: 412-417-6614 www.johnmeunier.com Fax: 215-885-4741 asteele@johnmeunier.com Revised : 2008-10-01