Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Similar documents
C1000 Series Automatic Cap Bank

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SWITCHGEAR DIVISION PRODUCT PROFILES

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Horizontal Circuit Switchers

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Technical Specification for Pole Mounted Capacitor Rack

Horizontal Circuit Switchers

Metal-enclosed medium voltage power factor correction system

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Publication No.: PSG

Metal-enclosed medium-voltage power factor correction system

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Customer Substation Manual

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

GE 8000-Line Motor Control Centers

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

10 Commercial, Industrial, Agricultural Services

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Design Standard. Purpose: Design Standard:

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Design Standard. Capacitor Bank. Detailed specifications follow. PART 1 - GENERAL

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

SECTION MOTOR CONTROL

Unit Substation Transformers 5 and 15 KV Class

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

UNDERGROUND SERVICES - SECONDARY

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

BGE STRATEGIC CUSTOMER ENGINEERING

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Chapter 6 Generator-Voltage System

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

7. SERVICES OVER 600 VOLTS

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

A. Submit manufacturer's literature and technical data before starting work.

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SECTION PANELBOARDS

Medium Voltage Metal-Enclosed Switches

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

100 / 110 DRYWELL FUSE SPECIFICATION

Medium Voltage Metal-Enclosed Switches

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

AMENDMENT ELECTRIC SERVICE MANUAL 2014

IN2 Enclosed Switches and Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

University of Houston Master Construction Specifications Insert Project Name

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Wye or Delta Systems DS9181 (CSA Approved)

Switchgear Skid, C1192

Three-Phase Pole Mounted Recloser

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

MEDIUM VOLTAGE METAL ENCLOSED CAPACITOR BANKS

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

S&C Manual PME Pad-Mounted Gear

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Service Entrance Methods

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Outdoor Padmount Switching Products

Medium Voltage. ANSI C37.20 and NEMA SG-5

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

EMPAC Metal enclosed capacitor bank for wind applications

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Transcription:

c February, 1979 Supersedes DB 39-485, pages 1-4, dated November, 1973 Mailed to: E, D, C/2001, 2002/DB Benefits There are many capacitor applications in which factors such as physical location, personnel safety, appearance, etc., make the use of metal enclosed capacitor equipment much more desirable than open rack equipment. The Westinghouse metal enclosed Dyna-Vac capacitor equipment is specifically designed for these applications. Packaged Design: Contained within a single, factory assembled, weatherproof, metal housing of modern design and pleasing appearance are the following: 1. Sufficient capacitors for the total Kvac rating required. 2. Current limiting fuses on each capacitor unit. 3. Thermostatically controlled fans for forced ventilation to prolong capacitor life. 4. A power entrance or switch compartment with appropriate provisions for terminating purchasers incoming lines and containing all desired accessories. ndoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz Safety: All live parts are completely enclosed in a grounded, weatherproof sheet metal housing. Capacitor doors are mechanically interlocked with maintenance ground switch and may be padlocked. Small Size: New larger Kvac capacitor units reduce equipment dimensions compared to earlier metal enclosed designs. Substation ground area required is substantially reduced compared to open rack designs since no electrical clearances to adjacent structures are necessary. Low overall height, less than 9 feet, is much lower than most open rack installations where 8 foot supporting structures are common practice. Low nstallation Cost: Unlike open racks which are shipped as sub-assemblies requiring field assembly, erection, and interconnection most metal enclosed Dyna-Vac equipments are shipped completely assembled including switches and other accessories (when ordered). Fasten the enclosure to a pad or Descriptive Bulletin 39-485 Page 1 Metal Enclosed Dyna-Vac Capacitor Equipments other foundation, bring in line and control leads, and the installation is complete. mproved Capacitors: Latest designs incorporating a synthetic film dielectric system provide: low losses averaging less than 0.5 watts/kvac; lower operating temperature with corresponding longer life; better transient voltage withstand characteristics. Pleasing Appearance: Smooth contours and low height are much preferred to open rack structural designs. Fewer Outages: Completely protected from outages caused by rodents, snakes, birds, debris, etc., which sometimes get into open rack equipments. Summary: The above features all contribute to lower total operating costs and lower installation cost. Metal enclosed capacitors are a growing trend. Utilities or other purchasers not presently using metal enclosed capacitors are overlooking a desirable capacitor equipment design for many applications.

Page 2 KVAC Ratings Metal enclosed capacitor equipments are available from 600 Kvac and up. Standard equipments with capacitor compartments sizes from 12 through 42 units have a 1-piece roof and are non-expandable. Equipments larger than 42 unit capacity are supplied in two sections, bolted together. Voltage Ratings: Equipments are available from 2400 volts through 14,400 volts. Standard equipments use capacitor units rated for the line-to-neutral voltage of the system and are wye connected. The neutral may be grounded or ungrounded at the purchasers option. For 2400 volts systems, 2400 volt capacitor units are used and connected in Delta. The overall equipment BL is 95 Kv. This is reduced to 75 Kv BL whenever 2400 through 4800 volt capacitor units are installed, since these units are rated 75 Kv BL in accordance with NEMA standards for shunt capacitors. Metal enclosed Dyna-Vac capacitor equipments are available in 3 basic arrangements: unswitched (Type ); switched (Type ); and switched with an auxiliary entrance compartment (Type ll). G) Line Entrance Compartment: Unswitched equipments include a power entrance compartment containing 3 phase buses and a neutral bus all insulated from the enclosure. Underground line leads may be brought in by conduit through a removable plate in the compartment floor, or connected to 3 roof bushings if they are specified. The power entrance compartment will accommodate some small accessories such as potheads, cable terminators, control power transformer, etc. Switch Compartment: Switched equipments include an additional compartment with a barrier between it and the capacitor compartment. The switch compartment will accommodate any of the following electrically operated switching devices: 3-200 ampere, single pole, type CSL oil switches 1-400 ampere or 600 ampere, 3 pole, vacuum switch 1-600 ampere, 3 pole, vacuum circuit breaker 1-600 ampere, 3 pole, vacuum circuit breaker with disconnect provisions n addition, small accessories such as: inrush limiting reactors; current transformers; control power transformer; and control panel may be included. f an electrically operated switch is not included, the switch compartment may incorporate other devices such as 3 power fuses or isolating disconnect switches, either hook stick or gang operated. @ Auxiliary Compartment: An auxiliary compartment, barriered from the switch compartment, is included with those equipments requiring a major accessory in addition to the switch. Devices which may be mounted in the auxiliary compartment include power fuses, hook stick or gang operated isolating switches, current transformers, control panel, etc. Safety: A short circuiting and grounding switch is a standard feature with all metal enclosed Dyna-Vac capacitor equipments for safety during maintenance. The switch is mechanically interlocked with all capacitor compartment doors to prevent access to the compartment unless the phase and neutral buses are shorted and grounded. Conversely, the shorting and grounding switch cannot be opened until all capacitor compartment doors are closed and latched. As a further precaution, the short circuiting and grounding switch may be provided with a key interlock for coordinating with the capacitor switch if it is included in the capacitor equipment, or with the purchaser's remote main disconnect switch or circuit breaker, to prevent groundwww. ElectricalPartManuals. com

8 ing the capacitor buses while the breaker is closed and to prevent closing the breaker while the buses are grounded. @) Capacitor Compartment: Standard capacitor compartment sizes available are: 12, 18, 30, 42, 48, 60 and 72 unit capacity. ntermediate Kvac ratings, or initial Kvac ratings with space for future uprating, will be supplied with a compartment suitable for the ultimate Kvac rating and omitting capacitor units and fuses in multiples of 3 to obtain the desired initial Kvac rating. The capacitor compartment contains a welded steel frame which is solidly connected to the sheet metal weatherproof enclosure. This frame supports the capacitor units in a single row, 3 tiers high. The capacitors are edge mounted with the bushings facing the doors. Removal or addition of individual capacitor units is easily accomplished through the hinged doors on the front side of the enclosure. Horizontal aluminum buses mounted on indoor bus support insulators support the current limiting capacitor unit fuses. The floor of each capacitor compartment is made from expanded metal screen, and the top rear of the compartment is louvered and screened. This permits free air circulation and prevents the entrance of rodents, foreign matter, wind driven rain, etc. One or more 1/4 horsepower, 115 volt single phase fans are mounted in the bottom of the capacitor compartment to provide forced ventilation. Each capacitor compartment also contains one or more sets of thermostats. A set consists of two thermostats, one of which starts the fans when the temperature reaches 1 ooof and stops the fans when the temperature reaches 80 F. The second thermostat may be used as a safety feature to trip the capacitor switch and remove the capacitor from service or sound an alarm. t operates at 135 F and is manually reset. Capacitor Units: Capacitor units are standard outdoor, single phase, 2 bushing, 60 Hertz, 100, 150, or 200 Kvac units of the type applied on distribution systems. These Dyna-Vac capacitors contain a synthetic film dielectric system which results in very low losses, higher Kvac per unit, reduced volume per Kvac, lower operating temperatures with corresponding longer life, and high transient voltage withstand ability. Each capacitor contains an internal discharge resistor which will drain the residual voltage to 50 volts crest in less than five minutes after the unit has been disconnected from the circuit. Descriptive Bulletin 39-485 Page 3 Fuses: All metal enclosed Dyna-Vac capacitor equipments, regardless of voltage rating or connection, include one current limiting fuse for each installed capacitor unit. These fuses provide visual indication of fuse operation. The ampere rating and voltage rating of the fuse is selected to coordinate with the particular capacitor unit with which it is used. Finish: Each equipment is chemically cleaned and phosphated after fabrication to remove grease, oil, and dirt. This is followed by one coat of alkyd primer and a finish coat of outdoor weatherproof acrylic paint, light gray ASA-70 in color. As additional protection, all under surfaces are "undercoated" with a two coat rust and waterproof finish. Shipping and Handling: Entire equipments, up to 20 feet in overall length, are designed to be shipped as one complete assembly. Longer equipments may be shipped in two or more sections to facilitate handling. Lifting lugs on both sides of the equipment near the top provide for unloading or moving with slings where a crane is available. The heavy steel base permits jacking and may be used for skidding if necessary.

Descriptive Bulletin 39-485 Page 4 Optional tems Following is a partial list of optional items and accessories which may be incorporated in standard metal enclosed equipments. 1. 200 ampere oil switches 2. 400 and 600 ampere vacuum switches 3. 600 ampere vacuum circuit breakers nterlock Sequence 1. Trip Breaker With ""A 1 ''; Key Released; Breaker is Locked Open and "69" Device is Tripped. 2. Unlock Disconnect Switch With "A 1 "; Key Retained. 3. Open Disconnect Switch and Lock Open With "A2"; Key Retained. 4. Unlock Ground Switch With "A2"; Key Retained. 5. Close Ground Switch; Capacitor Compartment Doors can now be Opened. 6. To Energize Bank; Close and Latch Capacitor Compartment Doors and Reverse Sequence. Note: "69" Device must be Manually Reset. 1200 Amp AWP 3PST Disconnect Switch 8 "" Q 6.00 Side View Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, ndiana 47401 4. Hookstick operated isolating switches 5. Gang operated isolating switches 6. Power fuses 7. Potheads 8. Roof bushings 9. nrush limiting reactors 10. Moulded or bushing type current transformers Dimensions in nches (Approximate) 11. Small LV power transformer 12. Lightning arresters 13. Unbalance detection (CT and relay) for wye-wye floating neutral banks 14. Current, voltage, VAR controls for electrically operated switches -------v-------" Louver Louvers -.-+--- ------- ---*-- ----- ---rrt Plan View Opening with Removable Cover for Customer Power Entrance. Customer to Drill to Suit 2.750 Hinged Bolted Door --------- ------------- -- ---------------- - - - ::- \:.----------.::::-::. ----=...,d _t ' ' -t -- F"< t;t' '.ll.j!.':!>: ly '" i 1 R 3 Vacuum : 1-400 BCT"s 2000/5 Amps Breaker 1 J ' P, / 1,-.,- j'l---fl: 1 1011 11L" 1 1 W F r- u., J Capacitor Capacitor Capacitor ] Comportment Compartment Compartment -) L_j : -: ---:------ ' ' [ J -. J --------- 1:1 : Control Panel l - - - -.:-=-=== --::.f_ : (- Window 1_A---_J j - '! 9 9 9 1 Ground Switch 1 : Compartment \ Fan C?!t-:.;:=.' ' ',.L- i \_ B.875... - PMT-75 Hinged Door with -.j 1--8_875 Transformer Padlock Provision Ground Pad l-- 16.750 l--5.375 -- l-1.750 l+t---115.031 ---...-.1 1+--- 97.000 ----1 l---253.00 ----+l ----264.00 ---- Front View ' ' - Fan (= 1[1 ', L - Fan (:3:r:;=> ', l 0

c Westinghouse Benefits There are many capacitor applications in which factors such as physical location, personnel safety, appearance, etc., make the use of metal enclosed capacitor equipment much more desirable than open rack equipment. The Westinghouse metal enclosed Dyna-Vac capacitor equipment is specifically designed for these applications. Packaged Design: Contained within a single, factory assembled, weatherproof. metal housing of modern design and pleasing appearance are the following: 1. Sufficient capacitors for the total Kvac rating required. 2. Current limiting fuses on each capacitor unit 3. Thermostatically controlled fans for forced ventilation to prolong capacitor life. 4. A power entrance or switch compartment with appropriate provisions for terminating purchasers incoming lines and containing all desired accessories. Safety: All live parts are completely enclosed in a grounded. weatherproof sheet metal housing. Capacitor doors are mechanically interlocked with maintenance ground switch and/or may be padlocked. Small Size: New larger Kvac capacitor units reduce equipment dimensions compared to earlier metal enclosed designs. Substation ground area required is substantially reduced compared to open rack designs since no electrical clearances to adjacent structures are necessary. Low overall height less than 9 feet is much lower than most open rack installations where 8 foot supporting structures are common practice. Low nstallation Price: Unlike open racks which are shipped as sub-assemblies requiring field assembly, erection, and interconnection most metal enclosed Dyna-Vac equipments are shipped completely assembled including switches and other accessories (when ordered). Fasten the enclosure to a pad or other foundation. bring in Descriptive Bulletin 39-485 Page 1 Metal Enclosed Dyna-Vac Capacitor Equipments ndoor or Outdoor 2400 to 14,400 Volts 1200 to 1 0,800 Kvac, 3 Phase, 60 Hz line and control leads, and the installation is complete. mproved Capacitors: Latest designs incorporating a synthetic film dielectric system provide: low losses averaging less than 0.5 watts/kvac; lower operating temperature with corresponding longer life; better transient voltage Withstand characteristics. Pleasing Appearance: Smooth contours and low height are much preferred to open rack structural designs. Fewer Outages: Completely protected from outages caused by rodents, snakes, birds, debris, etc.. which sometimes get into open rack equipments. Summary: The above features all contribute to lower total operating costs and lower installation cost. Metal enclosed capacitors are a growing trend. Utilities or other purchasers not presently using metal enclosed capacitors are overlooking a des lrable capacitor equipment design for many applications. November, 1973 New nformation E. D, C/2001, 2002/DB

Descriptive Bulletin 39-485 Page 2 Westinghouse KVAC Ratings Depending on the circuit voltage. metal enclosed capacitor equipments are available from 1200 Kvac up to 10.800 Kvac based upon using a 600 ampere continuous switch. Standard equipments with capacitor compartments sizes from 12 through 42 units have a 1-piece roof and are non-expandable. Equipments larger than 42 unit capacity are supplied in two sections. bolted together at the factory, and include a removable end panel on the last capacitor compartment. This feature (which may be supplied with smaller equipments when specifically negotiated) does permit future expansion by bolting on additional capacitor compartments. Voltage Ratings: Equipments are available from 2400 volts through 14.400 volts. Standard equipments use capacitor units rated for the line-to-neutral voltage of the system and are wye connected. except for 2400 volt systems. The neutral may be grounded or ungrounded at the purchasers option. For 2400 volts systems, 2400 volt capacitor units are used and connected in Delta. The overall equipment Bl L is 95 Kv. This is reduced to 75 Kv BL whenever 2400 through 4800 volt capacitor units are installed, since these units are rated 75 Kv BL in accordance with NEMA standards for shunt capacitors. Metal enclosed Dyna-Vac capacitor equipments are available in 3 basic arrangements: unswitched (Type ); switched (Type ); and switched with an auxiliary entrance compartment (Type ll). 0 Line Entrance Compartment: U nswitched equipments include a power entrance compartment containing 3 phase buses and a neutral bus all insulated from the enclosure. Underground line leads may be brought in by conduit through a removable plate in the compartment floor, or connected to 3 roof bushings if they are specified. The power entrance compartment will accommodate some small accessories such as potheads, cable terminators, control power transformer, etc. G switch Compartment: Switched equipments include an additional compartment with a barrier between it and the capacitor compartment. The switch compartment will accommodate any of the following electrically operated switching devices: 3-200 ampere, single pole, type CSL oil switches 1-400 ampere or 600 ampere, 3 pole, type PRC oil switch 1-400 ampere or 600 ampere, 3 pole, vacuum switch 1-600 ampere, 3 pole, vacuum circuit breaker 1-400 or 600 ampere, 3 pole, type LBF fused load-break switch (manually operated) n addition. small accessories such as: inrush limiting reactors; current transformers; control power transformer; and control panel may be included. f an electrically operated switch is not included, the switch compartment may incorporate other devices such as 3 power fuses or isolating disconnect switches. either hook stick or gang operated. e Auxiliary Compartment: An auxiliary compartment. barriered from the switch compartment. is included with those equipments requiring a major accessory in addition to the switch. Devices which may be mounted in the auxiliary compartment include power fuses, hook stick or gang operated isolating switches, current transformers, control panel. etc. Safety: A short circuiting and grounding switch is a standard feature with all metal enclosed Dyna-Vac capacitor equipments for safety during maintenance. The switch is mechanically interlocked with all capacitor compartment doors to prevent access to the compartment unless the phase and neutral buses are shorted and grounded. Conversely, the shorting and grounding switch cannot be opened until all capacitor compartment doors are closed and latched. As a further precaution, the short circuitwww. ElectricalPartManuals. com

ing and grounding switch may be provided with a key interlock for coordinating with the capacitor switch if it is included in the capacitor equipment, or with the purchaser's remote main disconnect switch or circuit breaker, to prevent grounding the capacitor buses while the breaker is closed and to prevent closing the breaker while the buses are grounded. 0 Capacitor Compartment: Standard capacitor compartment sizes available are: 12, 18, 30. 42. 48. 60 and 72 unit capacity. ntermediate Kvac ratings. or initial Kvac ratings with space for future uprating, will be supplied with a compartment suitable for the ultimate Kvac rating and omitting capacitor units and fuses in multiples of 3 to obtain the desired initial Kvac rating. The capacitor compartment contains a welded steel frame which is solidly connected to the sheet metal weatherproof enclosure. This frame supports the capacitor units in a single row. 3 tiers high. The capacitors are edge mounted with the bushings facing the doors. Removal or addition of individual capacitor units is easily accomplished through the hinged doors on the front side of the enclosure. Horizontal aluminum buses mounted on indoor bus support insulators support the current limiting capacitor unit fuses. The floor of each capacitor compartment is made from expanded metal screen. and the top rear of the compartment is louvered and screened. This permits free air circulation and prevents the entrance of rodents. foreign matter, wind driven rain. etc. One or more % horsepower. 11 5 volt single phase fans are mounted in the bottom of the capacitor compartment to provide forced ventilation. Each capacitor compartment also contains one or more sets of thermostats. A set consists of two thermostats. one of which starts the fans when the temperature reaches 1 OO'F and stops the fans when the temperature reaches SO'F. The second thermostat may be used as a safety feature to trip the capacitor switch and remove the capacitor from service or sound an alarm. t operates at 135'F and is manually reset. Capacitor Units: Capacitor units are standard outdoor, single phase. 2 bushing. 60 Hertz. 100, 150, or 200 Kvac units of the type applied on distribution systems. These Dyna-Vac capacitors contain a synthetic film dielectric system which results in very low losses, higher Kvac per unit reduced volume per Kvac. lower operating temperatures with corresponding longer life. and high transient voltage withstand ability. Each capacitor contains an internal discharge resistor which will drain the residual voltage to 50 volts crest in less than five Descriptive Bulletin 39-485 Page 3 Metal Enclosed Dyna-Vac Capacitor Equipments ndoor or Outdoor 2400 to 14,400 Volts 1200 to 10,800 Kvac, 3 Phase, 60 Hz minutes after the unit has been disconnected from the circuit. Fuses: All metal enclosed Dyna-Vac capacitor equipments. regardless of voltage rating or connection. include one current imiting fuse for each installed capacitor unit. These fuses have an interrupting rating of 60.000 amperes asymmetrical and provide visual indication of fuse operation. The ampere rating and voltage rating of the fuse is selected to coordinate with the particular capacitor unit with which it is used. Finish: Each equipment is chemically cleaned and phosphated after fabrication to remove grease. oil. and dirt. This is followed by one coat of alkyd primer and a finish coat of outdoor weatherproof acrylic paint. light gray ASA-70 in color. As additional protection, all under surfaces are "undercoated" with a two coat rust and waterproof finish. Shipping and Handling: Entire equipments, up to 20 feet in overall length. are designed to be shipped as one complete assembly. Longer equipments may be shipped in two or more sections to facilitate handling. Lifting lugs on both sides of the equipment near the top provide for unloading or moving with slings where a crane is available. The heavy steel base permits jacking and may be used for skidding if necessary.

Descriptive Bulletin 39-485 Page 4 Metal Enclosed Dyna-Vac Capacitor Equipments ndoor or Outdoor 2400 to 14,400 Volts 1200 to 10,800 Kvac, 3 Phase, 60 Hz Optional tems Following is a partial list of optional items and accessories which may be incorporated in standard metal enclosed equipments. 1. 200, 400 and 600 ampere oil switches 2. 400 and 600 ampere vacuum switches 3. 600 ampere vacuum circuit breakers Typical Switch Com partments Typical Auxiliary Compartments Further nformation: OS 39-486 Westinghouse Electric Corporation Distribution Apparatus Division, Bloomington, ndiana 47401 Printed in USA 4. 400 and 600 ampere manually operated fused load-break switch 5. Hookstick operated isolating switches 6. Gang operated isolating switches 7. Power fuses 8. Potheads 9. Roof bushings 10. nrush limiting reactors 11. Moulded or bushing type current transformers 12. Small LV power transformer 13. Lightning arresters 14. Unbalance detection (CT and relay) for wye-wye floating neutral banks 14. Current. voltage, VAR controls for electrically operated switches 0