SE2000BX Static Exciter

Similar documents
XR500B Universal Voltage Regulator

Specifications. Minimum Build Up Volts 3.5vac. Voltage Regulator

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

AFM500X Automatic Flashing Module

MP24 Motorized Potentiometer

SE450 Static Exciter Module

MOP1224HD Heavy-Duty Motorized Potentiometer

ABF40 Automatic Battery Flash Unit

XR500D-277V Special Voltage Regulator

AFM500X Automatic Flashing Module

XR500D Universal Voltage Regulator

VoltPro VP4 Automatic Voltage Regulator

DC250i. Voltage Regulation: Specifications

VoltPro VPBF8 Automatic Battery Flashing Module This Manual Covers Both VPBF8-12 and VPBF8-24 Models

PC1000B Phase Control

INSTALLATION & OWNER'S MANUAL

REVISION A (FROM SERIAL

A1P OPERATING MANUAL

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

A6Z OPERATING MANUAL

INSTRUCTION MANUAL FOR

SDC,Inc. SCR-Regenerative Ac Drive

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

XR5C Specialty Series Universal Voltage Regulator

XR5B Hz Specialty Series Universal Voltage Regulator

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

A3Z OPERATING MANUAL

INDEX Section Page Number Remarks

XC4 Commercial Series

Electric Motor Controls BOMA Pre-Quiz

QSSE, QSSEX INDUSTRIAL Battery Chargers

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

WF-5100 Series True Sine Wave Inverters

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Electric Utility Contact Information Indiana Michigan Power

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

OPERATING INSTRUCTIONS

WF-5110R True Sine Wave Inverter

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS

Operations Manual. Zero Speed Switch Sensor Model ZS09P

OBAE, OBAEXU, ON BOARD Battery Chargers

INSP-3 Wiring Inspection Tester

MX431 Generator Automatic Voltage Regulator Operation Manual

AUTO CHARGE D PUMP PLUS

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

WF-5110R True Sine Wave Inverter

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

GENERATOR INTERCONNECTION APPLICATION

Instruction Manual. Installation Operation Maintenance. KCR 760 Voltage Regulator

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SCR Power Controllers

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

OBE, OBEXU, ON BOARD Battery Chargers

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

1000 Watt Pure Sine Wave Power Inverter, Users Manual

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Pure Sine Wave Inverter 600W-24V User Manual

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Harris IRT Enterprises Digital Resistance Tester Model XP

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

INDUSTRIAL GENERATOR SERVICE

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

BATTERY SAVER LOW RIPPLE HO

5.2 PRE-OPERATION PROCEDURE WARRANTY

XENON POWER SUPPLY 4000 Watt Gladiator IV

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

A2P Single Phase Automatic Industrial Battery Charger

Unit 32 Three-Phase Alternators

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Basics of Paralleling

A39 UNIVERSAL SCR CHARGER

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

APPENDIX B SPECIFICATION FOR GENERATOR OVERHAUL EMD MODEL AR10 D18... B-1

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

QPET, QPETXU Battery Chargers

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

MIL-24/2600Q MIL-24/3200DQ

Transcription:

Rev 3 SE2000BX Static Exciter The SE2000BX Static Exciter is designed to replace most electronic, saturable reactor and rotary exciters used on slip ring or rotor fed electric generators. The SE2000BX offers unique features such as a remote mounted control panel and easy serviceability in the field. The input power and voltage sensing for the SE2000BX are taken directly from the generator AC stator and rectified into a controllable DC input to the main generator rotor. The SE2000BX is a complete static exciter that includes the voltage regulator, power fusing, surge suppression, build up module and connection terminals. Optional devices are offered for the SE2000BX such as an interface card, which allows the SE2000BX to be controlled with power factor controllers and other types of genset and PLC controllers. The SE2000BX has provisions for parallel operation. Specifications: Input Voltage 190 to 250vac, single phase Output Amperage 200adc continuous Type Regulation Flat response/vph Protection Internal fusing Physical Size 24 x 30 x 12 in Weight 50 lbs Voltage Regulator XR500D Build up module AFM500X Build up voltage 6.5vac

The SE2000BX is a complete static exciter assembly that is ready for installation. The SE2000BX is designed for simple installation and the voltage regulator assembly is designed so that it can be remotely located for safety and operator convenience. The SE2000BX should be located in a dry and clean area with free airflow over the rectifier section. Installation Instructions: Only professional electrical generator service technicians should install this equipment! Wear safety gear such as eye and face protection and use high voltage blankets and gloves when working on exposed electrical equipment that could cause electrocution or personal injury! Do not operate this generator at speeds lower than synchronous speed with the static exciter energized! 1. Unpack the SE2000BX from its shipping container and inspect the unit for shipping damage or loose parts. 2. Carefully read the installation instructions before attempting installation. 3. Check generator slip rings and brushes for proper contact and ring condition. 4. Mount exciter onto a cabinet or housing. You can mount the regulator control assembly in another location for safety and ease of operation. 5. Install 190 to 240vac single phase to the AC1 and AC2 terminals of the static exciter (Fig A). It is highly recommended that a disconnect switch or breaker is placed between the generator stator and the static exciter for emergency purposes! 6. Install the F+ and F- wiring to the F+ and F- terminals located on the bus bar assemblies of the static exciter (Fig A). 7. Connect up wiring to TB3 as shown in the following wiring diagrams (Fig B and C). 8. Perform a complete final check of the wiring of this static exciter before going to the next step! 9. Turn the regulator off/on switch to off. 10. Start prime mover and bring up to design speed. 11. Turn run/idle switch to run or on. 12. Set up the voltage regulator as per the regulator setup specifications supplied with this static exciter (XR500D Universal Voltage Regulator). This static exciter is shipped set up for 208vac @ 60hz. If the voltage is pulsing, it possibly could mean that the build up relay is plugging. This plugging can be corrected by raising the internal voltage adjustment on the XR500D until the voltage begins to rise and pulls in the build up relay (about 200vac). 13. Set voltage to your specification and observe for at least 10 minutes. 14. Apply load.

Figure A Main power input and field wiring diagram Safety Disconnect Switch SE2000BX 240vac from generator F+ to main rotor F- to main rotor Removable Control Panel

Figure B Control Wiring* *The SE2000BX static exciter has a removable control panel located below the main rectifier assembly. It is recommended that this panel be mounted in a location away from the main exciter assembly for safety and operator use. The relocation should be as close to the exciter assembly as possible. AFM500X Auto Flash Module Control panel is shown without special options! XR500D Universal Voltage Regulator TB3 A B C D E F Use battery flash only if needed! Isolated Battery 12/24V + - 45 Amp Diode, 800V 1000 ohm, 1/2 watt Remote Voltage Adjustment Customer Supplied DPST N.O. Switch Regulator off / on Switch

Figure C *Additional Hookup connections for parallel operation of the SE2000BX * Optional, must be ordered on original specifications. 5 amp CT GENERATOR A B C Droop Adjustment 6Ω, 100w 240vac AC1 SE2000BX AC2 Unit / Parallel Switch X Y TB3 A B C D E F Generator voltage should droop during starting of an inductive load, if it rises, reverse the X and Y connections. Always close the Unit/Parallel switch during non-parallel operation of the generator. The current transformer must be totally isolated from all other circuitry of the generator, instrumentation panels or controls.

Figure D Additional connections to configure the voltage control panel for use with the UIC200 Universal Interface Module. TB3 E F UIC200 * D E Manual Selector Automatic Remote Voltage Adjustment 100K * You can use either a (+/-5vdc) or (+/-10vdc) or (+ 0-5vdc) or (+ 0-10vdc) input from either an analog or digital signal from an external source such as a power factor controller, genset controller or PLC. Refer to the UIC200 instruction manual for complete details.

PRODUCT WARRANTY Power-Tronics, Inc., assumes no liability for damages due to incorrect voltage or other voltage related damages resulting from either output of the generator or input to the generator exciter system. These problems should be protected with external devices provided by the customer such as fuses, surge suppressors, over/under voltage and frequency controls, manual disconnects or any other protective device. Power-Tronics, Inc., warranties only parts and workmanship of this product for a period of 2 years from the original date of purchase from Power-Tronics, Inc. Under warranty, Power-Tronics, Inc. will replace, exchange or repair the defective product without labor or parts cost to the customer. Remaining warranty of the original product will be transferred to the replaced or repaired product. To obtain warranty, a copy of the original purchase receipt must be sent in with the defective product, which clearly shows the purchase date and serial number of the defective part. A repair request form must be sent in with the product before repairs will begin. You can obtain this form through contacting Power-Tronics, Inc. Send repairs to: Power-Tronics, Inc., 2802 Cobbler Ln., Kerrville Texas USA 78028. Send in repairs only by UPS or FedEx. Any one of the following conditions will void the warranty:! Overheating of the power supply components.! Overheating of the SCRs or freewheeling diodes.! Physical damage to the printed circuit cards, housing or components.! Unauthorized repair or alteration of this product.! Conductive or corrosive contamination.! Removal of our company identification from the product.! Removal of any conformal coating of the printed circuit cards or other components.! Damage due to overheating or alteration.! Inappropriate or infeasible application.! Installation by anyone other than a fully qualified and experienced professional electrical generator service and repair technician or engineer.! Misuse.! Damage to this product resulting from external sources such as field windings, brush and slip ring arcing and other driven devices.! Use with any external device not manufactured by Power-Tronics, Inc. No other warranty is expressed or implied.