Zenith ZBTS/ ZBTSD/ZBTSCT

Similar documents
Secondary DC Distribution

Zenith ZTX. GE Energy Digital Energy. Automatic Transfer Switch

Fuse / Circuit Breaker Panels

OTEC Transfer switch open transition

Emergency Generator Replacement Roseway Hospital

Transfer switch OTEC and OTECSE open transition

5067 Mini BDFB / BDCBB

Transfer switch OTEC open or delayed transition

OTPC-SE Service entrance transfer switch open transition

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

SECTION PANELBOARDS

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

Transfer switch OHPC open or delayed transition

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

TS880 AUTOMATIC TRANSFER SWITCHES

596 Rectifier Retrofit

BTPC Bypass isolation transfer switch open or closed transition

Quick Start Guide TS 910 & TS 920

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

CHPC Transfer switch closed transition

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Bolted contact switches. Pringle switches

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

A. Submit manufacturer's literature and technical data before starting work.

OTPC Transfer switch open and closed transition

Bypass/Isolation Switches RTS-03 SERIES

Specialty Service Entrance Switchboards. Selection and Application Guide

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Design Standard. Purpose: Design Standard:

Transfer switch OTPC open, closed, or delayed transition

Diesel generator set C17D5T series

Quick Start Guide TS 910

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

GTEC Transfer switch Open transition

Design considerations for generator set mounted paralleling breakers

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Design Guide for Integration of Fixed-Mount Circuit Breakers

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

Bypass/Isolation Switches RTS-30 SERIES

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Arial Regular 25pt. Learn Solar Installation From the Pros!

GTEC Transfer switch open transition

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Transfer switch GTEC open or delayed transition

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Service Entrance Methods

POWERFUL LINEUP. Paralleling Generator Sets

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Horizontal Circuit Switchers

Horizontal Circuit Switchers

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

ASCO Low Voltage Automatic Transfer Switch Systems

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

SECTION MOTOR CONTROL

Section 4 Square D QO Loadcentres

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Quik-Spec Coordination Panelboard Specifications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

C1000 Series Automatic Cap Bank

ASCO 7000 Series Power Transfer Switch Technical Data and Ordering Information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

EPOXY POWDER COATED COPPER FREE ALUMINUM

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Lighting and Power Distribution Panelboards

CON EDISON EQUIPMENT

Low Voltage Automatic Transfer Switch Systems

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

GE 8000-Line Motor Control Centers

Generator/Loadbank Quick Connection Tap Box

GE Critical Power. The Retrofit Case for Upgrading Legacy Power Systems at Telecom Central Offices

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Application guide. Tmax Link OEM UL 891 Switchboard Program

Bypass Isolation Transfer Switches Amperes

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Disconnect & ByPass Switches

Going the Distance - Solving Power Reach Issues With Diverse DAS Solutions

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Terminal Blocks. Section 12. Control Catalog 12-1

Transfer switch OT III open or delayed transition, non-automatic

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

GE Consumer & Industrial Electrical Distribution. Spectra Series Busway. Busway vs. Wire & Conduit. imagination at work

Rental Power QSL9 series engine

Transcription:

Critical Power from GE Zenith ZBTS/ ZBTSD/ZBTSCT Transfer/Bypass-Isolation Transfer Switches Introduction GE s Zenith ZBTS Series Bypass Isolation Transfer Switch consists of two major modules the automatic transfer and the bypassisolation switches. The automatic transfer switch module is GE s proven Zenith ZTS Series, built in ZTS, ZTSD or ZTSCT configuration and constructed for rugged, reliable operation. The same components heavy-duty silver alloy contacts, rugged drive mechanism and silver plated bus bar inter-connections are used throughout the ZBTS Series. Features and Benefits GE s design requires no additional load break contacts which cause load interruption during bypass-isolation functions. The bypass-isolation switch contacts are out of the system current path except during actual bypass operation. Therefore, they are not constantly exposed to the destructive effects of potential fault currents. The Source 1 (normal), Source 2 (emergency) and load are connected between the automatic transfer switch and the bypass-isolation switch through solidly braced isolating contacts that are open when the automatic transfer switch is isolated. All current carrying components provide high withstand current ratings in excess of those specified in UL 1008 standards. Design and Construction Features Automatic transfer switch is located on a draw out mechanism to facilitate maintenance Emergency power systems can be electrically tested without disturbing the load Power cables do not have to be disconnected to remove the transfer switch Bypass to any available source with the automatic transfer switch removed Engine start circuit maintained during bypass operation; normal power failure causes engine start contact closure even with the ATS removed Diagnostic lights and detailed instructions for simple stepby-step operation Mechanical and electrical interlocks ensure proper sequence of operation Bypass switch contacts are closed only during the bypass-isolation operation Silverplated copper bus interconnection of the transfer and bypass switches on all sizes Advantages Load is not interrupted during bypass operation High close-in and withstand capability Temperature rise test per UL 1008 conducted after overload and endurance tests exceeds UL requirements Available in ZBTS (utilitygenerator), ZBTSU (utility-utility), ZBTSG (generator-generator) and ZBTSM (manual) configurations; models include standard, delayed and closed transition

Description and Operation The bypass section is a ZTS switch provided with a quick make/quick break manual load transfer handle and GE s control/interlock system consisting of both mechanical and electrical interlocks. The bypass switch is equipped with normal failure sensing and a time delay to start the engine automatically if the ATS has been removed for service. The modules are mounted in a compact enclosure and completely interconnected requiring only Source 1 (normal), Source 2 (emergency) and load cable connections. Once installed, no cables need to be removed to isolate the transfer switch module for maintenance or inspection. The automatic transfer switch may be withdrawn for testing or maintenance without disturbing the load. The transfer switch module has three positions: 1. Automatic/Connected: The transfer switch is carrying the load, and the bypass switch is in the open position. This is the normal operating position. 2. Test: The bypass switch is closed and feeding the load. The transfer switch has control power and may be operated for test purposes via the test switch on the enclosure door. The load is not affected during testing.. Isolate: The transfer switch is withdrawn from all power and ready for maintenance. The load is served by the bypass switch. The Automatic Transfer Switch is installed on a draw-out mechanism, with electrical and mechanical interlocks for secure removal after load bypass. The ATS control/logic panel is mounted on the enclosure door and connected by a wire harness and multi-pin disconnect plugs. The transfer switch and/or the control panel may be tested, isolated and removed for maintenance without load interruption. The bypass-isolation switch module is the same basic design as the automatic transfer switch module and thus has the same electrical ratings. Manually operated, it features high speed, quick make/quick break contact action. The bypass-isolation switch has three basic positions: 1. Automatic: Source 1 (Normal) bypass contacts open, Source 2 (emergency) bypass contacts open. 2. Bypass Normal: Source 1 (Normal) bypass contacts closed, Source 2 (emergency) bypass contacts open.. Bypass Emergency: Source 1 (Normal) bypass contacts open, Source 2 (emergency) bypass contacts closed. Interlocks and Indicators Every ZBTS Series Bypass-Isolation Transfer Switch is supplied with all necessary electrical and mechanical interlocks to prevent improper sequence of operation as well as the necessary interlocking circuit for engine starting integrity. Each ZBTS Series Switch is furnished with a detailed, step-by-step operating instruction plate, as well as the following function diagnostic lights: Source 1 (Normal) Available Source 2 (Emergency) Available Bypass Switch in Source 1 (Normal) Position Bypass Switch in Source 2 (Emergency) Position Automatic Transfer Switch in Test Position Automatic Transfer Switch Isolated Automatic Transfer Switch Inhibit Automatic Transfer Switch Operator Disconnect Switch Off Automatic Transfer Switch in Source 1 (Normal) Position Automatic Transfer Switch in Source 2 (Emergency) Position 2 Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com

Electrical Ratings Ratings 100 to 000 amperes 2, or Poles Open type, NEMA 1, R,, X and 12 Available with Zenith ZTS, ZTSD and ZTSCT Series Automatic Transfer Switch Bypass and transfer switch have identical ratings Suitable for emergency and standby applications on all classes of load, 100% tungsten rated through 00 amps UL 1008 listed at 80 VAC CSA C22.2 No. 178 certified at 600 VAC UL 1008 Withstand and Closing Ratings Please refer to GE Publication TB-1102 Specifications ZBTS & ZBTSD AMPERE RATING POLES NEMA 1 ENCLOSED WEIGHT APPLICATION NOTES HEIGHT (A) WIDTH (B) DEPTH (C) REFERENCE FIGURE OPEN TYPE NEMA 1 100, 150, 225, 260 00 2, 8 (211) 8 (211) 0 (76) 0 (76) 28.5 (72.) 28.5 (72.) A 10 (11) 80 (17) 770 (50) 80 (22) 1 9 600 6 (91) 0 (102) B 660 (299) 770 (9) 1220 (5) 165 (619) 800, 1000 1200 0 (102) 6 (117) 765 (7) 910 (1) 155 (615) 1570 (712) 1600, 2000 2600 0.6 (10) 6.1 (117) 6.6 (16) 6.6 (16) C 1978 (897) 2275 (102) 0 (185) 1 (2010) 1 7, 10 000 0.6 (10) 6.1 (117) 6.6 (16) 6.6 (16) 2572 (1166) 09 (18) 56 (2021) 977 (2258) 1 7, 10-12 000 7.5 (121) 5 (17) 81 (206) 81 (206) D 10 (1955) 5510 (299) 660 (211) 5860 (2658) 1 7, 10 11 Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com

Specifications (Cont.) ZBTSCT AMPERE RATING POLES NEMA 1 ENCLOSED WEIGHT APPLICATION NOTES HEIGHT (A) WIDTH (B) DEPTH (C) REFERENCE FIGURE OPEN TYPE NEMA 1 100, 150, 225, 260 00, 600 6 (91) 0 (102) B 70 (1) 80 (81) 1280 (581) 185 (628) 1 8 800, 1000 1200 0 (102) 6 (117) 85 (79) 980 () 15 (651) 160 (7) 1-9 1600, 2000 2600 0.6 (10) 6.1 (117) 6.6 (16) 6.6 (16) C 1978 (897) 2275 (102) 0 (185) 1 (2010) 1 7, 10 000 0.6 (10) 6.1 (117) 6.6 (16) 6.6 (16) 2572 (1166) 09 (18) 56 (2021) 977 (2258) 1 7, 10-12 000 7.5 (121) 5 (17) 81 (206) 81 (206) D 80 (1986) 5580 (251) 70 (215) 590 (2689) Application Notes 1. Metric dimensions (cm) and weights (Kg) shown in parenthesis adjacent to English measurements in inches and pounds. 2. Includes 1.25 door projection beyond base depth. Allow a minimum of additional depth for projection of handle, light, switches, pushbuttons, etc.. All dimensions and weights are approximate and subject to change without notice.. Special enclosures (NEMA R,, X, 12, etc.) dimensions and layout may differ. Consult the GE factory for details. 5. Bypass Model product can not be ordered with inverted style. 6. Special lug arrangements may require different enclosure dimensions. For certified drawings, contact the GE factory. 7. Packing materials must be added to weights shown. Allow 15% additional weight for cartons, skids, crates, etc. 8. Add in height for removable lifting lugs. 9. ZBTS(D) 600-1200A & ZBTSCT 100-1200A standard configuration is top entry. 1 rear adapter bay required for bottom entry. Consult the GE factory for details. 10. Bypass switch weights for 1600-000 amp units vary up to 10% based on connections variations. Weights shown are for estimation only. 11. 000 amp depth dimension shown is standard. Depending on your cable/conduit requirements you may desire a deeper enclosure. Consult the GE factory for further details. 12. Lug adapters for 000-000 amp limits may be staggered length for ease of entrance. Consult the GE factory for details. Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com

Specifications (Cont.) Reference Figure OUTLINE DRAWINGS Drawing or Diagram Figure A Figure B Figure C Figure D ZBTS & ZBTSD: AL-CU UL Listed Solderless Screw-Type Terminals for External Power Connections SWITCH SIZE AMPS NORMAL, EMERGENCY & LOAD TERMINALS CABLES/POLE WIRE RANGES 100-225 1 #6 to 250 MCM 260 # to 600 MCM 00 600 2 #2 to 600 MCM 800 / 1000 / 1200 1600 / 2000 / 2600 / 000 / 000 * * ZBTSCT: AL-CU UL Listed Solderless Screw-Type Terminals for External Power Connections SWITCH SIZE AMPS NORMAL, EMERGENCY & LOAD TERMINALS CABLES/POLE WIRE RANGES 100-00 1 # to 600 MCM 600 2 #2 to 600 MCM 800 / 1000 / 1200 #2 to 600 MCM 1600 / 2000 / 2600 / 000 / 000 * * * Line and load terminals are located in rear and arranged for bus bar connection. * Terminal lugs are available at additional cost. Contact the GE factory for more details. Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com 5

Specifications (Cont.) ZBTSD Model Delayed Transition Transfer/Bypass-Isolation Switches The ZTSD Delayed Transition Transfer Switch with a timed center-off position is available in a bypass configuration. The ZBTSD Model Bypass incorporates the features of both the ZBTS Bypass-Isolation Switch and the ZTSD unit for transfer of large motor loads, transformers, UPS systems or load shedding to a neutral Off position. Reference the ZTSD unit features and operation discussion for more details. ZBTSCT Model Closed Transition Transfer/Bypass-Isolation Switches The ZTSCT Closed Transition Transfer Switch may be applied with a bypass-isolation switch for the utmost in reliability and versatility. The ZBTSCT Model provides the ability to withdraw the transfer switch unit for maintenance or inspection. Reference the ZTSCT unit features and operation discussion for more details. 6 Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com

Notes Zenith ZBTS/ZBTSD/ZBTSCT www.gecriticalpower.com 7

On-Site & Emergency Services 2/7 Emergency Hotline Spare Parts Spare Part Kits Product Replacement / Return Equipment Rentals Battery & Capacitor Replacements Contractual Services Maintenance Service Contracts Remote Monitoring & Diagnostics Technical Services Training Training for Operators Training for Maintenance Staff Product Training Web-Based Training Training GE offers on-site and classroom training options based on certification curriculum. Technical training can be tailored to individual customer needs. Training enables customers and partners to more effectively manage and support the power infrastructure. We have built our training program on practical learning objectives that are relevant to specific technologies or infrastructure design objectives. Service & Support GE field service and support personnel are trusted advisors to our customers always available to answer questions and help with any project, large or small. Our certified professional services team consists of experts in every aspect of power conversion with the resources and experience to handle large turnkey projects along with custom approaches to complex challenges. Proven systems engineering and installation best practices are designed to safely deliver results that exceed our customers expectations. Warranty GE is committed to providing quality products and solutions. We have developed a comprehensive warranty that protects you and provides a simple way to get your products repaired or replaced as soon as possible. For full warranty terms and conditions please go to www.gecriticalpower.com. GE Critical Power 601 Shiloh Road Plano, TX 7507 +1 877 56 2 www.gecriticalpower.com *Registered trademark of the General Electric Company. The GE brand, logo, and lumination are trademarks of the General Electric Company. 2016 General Electric Company. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. PB-5068, Rev. 05/2016