COMPONENTS FOR SOLAR THERMAL SYSTEMS

Similar documents
COMPONENTS FOR SOLAR THERMAL SYSTEMS

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/18 GB. replaces 01260/14 GB

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Motorised temperature regulating unit for heating and air conditioning systems WYP UPM series 01254/17 GB

PRESSURE CONTROL VALVES SABS 198

CALEFFI. Direct supply unit for heating systems. 165 series 01237/17 GB. replaces dp 01237/15 GB. Function

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

Components for central heating

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

CALEFFI. Motorised ball valve for central heating systems. 638 series 01196/18 GB. replaces dp 01196/12 GB

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

Connection and regulation kit for HVAC terminal units

THERMOSETTER Recirculation thermal balancing valve

Fan-coil valves Series

FLOW RATE STATIC BALANCING Valves for radiators

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Operating principle Application diagram. Regulator-actuator Wiring diagrams

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

CT3202.0_01 EN February 2018

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

MOTORISED BALL VALVE. Uni/Bi-directional. patented. 3 points 2 points Price list root SR... SS... SY... Connection with ball valve.

Superstatic 440. Static Heat- and Cooling Meter. Application

Art.918C Pre-assembled manifold with flow meters, air

Flow-compensated temperature controller AVTQ DN 15

T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

Simplex Pump and Socket Ball Valves Pump and Socket Ball Valves

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Pre-assembled distribution manifolds for radiant panel systems

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

Composite PEX-AL-PEX Tubing

Pump Stations for Heating Circuits

three-way mixing valve

Product range Solex Technical data and dimensioning. 5 Years

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Products for underfloor heating

MrPEX 1 ½ " Brass Manifold Installation Guide

2-position electric actuators with Ball valves VBZ ½...11/4

Gauges and Thermometers

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

HERZ-Motorised flow controler

VALVES WITH SA03 ELECTRIC ACTUATOR

franklinwater.com 50 Hz VR SERIES Vertical Multi-Stage Pumps

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

ON/OFF zone valves AMZ 112, AMZ 113

VG6000 Series Forged Brass Valves

TempControl Thermostatic Water Controllers

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

Barilla Solar Ltd. Product Brochure. Barilla Solar Lmt Unit 2, Dell Buildings Milford Road Lymington SO41 0ED T:

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Floor heating manifold with automatic flow control

Differential Pressure and Flow meters Accessories for the Media Series

FCU Floor Control Unit

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

STUDIO S BATH ACCESSORIES TOWEL BARS

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

CALEFFI. Hydraulic separator-manifold SEPCOLL. 559 series 01084/16 GB. replaces dp 01084/13 GB

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E

A range of shower fittings, precision engineered to provide an effective shower at all pressures. Available with either fixed or swivel heads

aquakit U Specifications Last revision: 09/07/2016 aquabrass.com

LK Manifold Shunt VS2

3 Specification Magneta Smedegaard

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Connections (*) Rev. f 04/08 1 DBL199E

DOMESTIC LPG REGULATORS & ACCESSORIES MOVABLE TANKS TANK INSTALLATION CONNECTED WITH MANIFOLDS

3-Port Seat Valves with Male Thread, PN 16

Accessories guide DHP-R

ON/OFF zone valves AMZ 112, AMZ 113

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

Gas Safety Shut-off Valve with thermally released Shut-off Device (TAE) DIN-DVGW for Gas: 695. Straight Pattern with TAE, Female End/Hose Union

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Valves, controls + systems Stations for the connection heat generator/heating circuit

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

40 geothermal ground loop manifolds

Heating Cost Allocation Valve with local acquisition of the flow temperature

VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

HYDRAULIC SEPARATOR PRODUCTION RANGE. Code Size Max. flow rate (l/h) " "1/ "1/ " 8.

Differential Temperature Controller

CALEFFI. HydroMixer motorized temperature mixing unit. 167 series 01239/13 NA. Function

Liquid filled Thermometers

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

4 Specification Magneta Smedegaard twin pumps

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

ACCREDITED. brass EN CW617N brass EN CW614N brass EN CW614N, chrome plated PTFE PSU EPDM

Transcription:

COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012

2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending on the kind of system, there can be glycol. Materials and performance of the components must necessarily take into account these particular operating conditions. COMPONENTS FOR PRIMARY CIRCUIT We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. All the diagrams, numerical data, etc., are not binding.

SAFETY RELIEF VALVE - AIR VENTS 253 tech. broch. 01089 Safety relief valve Brass body. Chrome plated. Female connections. PN 10. Oversized discharge outlet. Discharge rating: 1/2-50 kw - 100 kw. TÜV certified to SV100 7.7 No. TÜV SV 07 2009 SOL H p. Settings: 2,5-3 - 4-6 - 8-10 bar. 250 - Automatic air vent for solar thermal systems. Brass body. Chrome plated. Max. discharge pressure: 2,5 bar. Temperature range: -30 180 C. - Shut-off cock complete with seal. Brass body. Chrome plated. Temperature range: -30 200 C. 253042 253043 253044 253046 253048 253040 253052 253053 253054 253056 253058 253050 1/2 F x 1/2 F x 1/2 F x 1/2 F x 1/2 F x 1/2 F x x 1 F x 1 F x 1 F x 1 F x 1 F x 1 F 2,5 bar 3 bar 4 bar 6 bar 8 bar 10 bar 2,5 bar 3 bar 4 bar 6 bar 8 bar 10 bar 250831 250931 3/8 M without cock 3/8 M 251 tech. broch. 01135 DISCALAIR High-performance automatic air vent Brass body. Chrome plated. Female connections. Max. discharge pressure: 10 bar. 250 tech. broch. 01133 - Automatic air vent Brass body. Chrome plated. Max. discharge pressure: 5 bar. Temperature range: -30 180 C. - Shut-off cock complete with seal. Brass body. Chrome plated. Temperature range: -30 200 C. 251004 1/2 F 250300 250400 250 tech. broch. 01133 Shut-off cock complete with seal. Brass body. Chrome plated. Temperature range: -30 200 C. 3/8 M x 3/8 F - batterfly handle 1/2 M x 1/2 F - lever handle 250031 250131 3/8 M without cock 3/8 M The automatic air vent must be shut off after the system has been filled. 3

DEAERATORS - MANUAL AIR SEPARATOR 251 tech. broch. 01134 DISCAL Deaerator Brass body. Chrome plated. Female connections. Max. discharge pressure: 10 bar. 251 tech. broch. 01134 DISCAL Deaerator Brass body. Chrome plated. Female connections. With drain. Max. discharge pressure: 10 bar. 251003 251006 251007 1 F 1 1/4 F 251 tech. broch. 01134 DISCAL Deaerator for vertical pipes, Brass body. Chrome plated. Female connections. Max. discharge pressure: 10 bar. 251 tech. broch. 01197 Manual air separator Brass body. Female connections. 251905 251906 1 F 251093 Application diagram of DISCAL 251 series for vertical pipes Application diagram of 251 series 4

HEAT METER BALANCING VALVE WITH FLOW METER 75525 CONTECA tech. broch. 01146 Direct heat metering with local LCD reading or centralised reading with controller code 755010 or interface code 755055, Temperature range: 5 120 C. The CONTECA module is supplied complete with: - Pair of temperature probes with immersion pockets. - Y pockets for immersion probes. - Water meter, with pulse output (max. temperature 120 C). - Electronic integrator with LCD. - Supply 24 V (ac) 50 Hz - 1 W. - Set for transmission in RS485 Bus mode. Conformity to EN 1434-1. 258 tech. broch. 01148 Balancing valve with flow meter, Direct reading of flow rate. Brass valve body and flow meter. Chrome plated. Ball valve for flow rate adjustment. Graduated scale flow meter with magnetic movement flow rate indicator. With insulation. Temperature range: -30 130 C. 258503 258533 258523 258603 1 Flow rate range (l/min) 12 07 13 10 17 28 10 40 BALL VALVE AND THREE-PIECE UNION FITTING Conn. Meas. type Q nom m 3 /h 240 tech. broch. 01185 Ball valve for solar thermal system. Body and ball in stainless steel AISI 316. PN 63. Female connections. Handle in stainless steel AISI 304. Temperature range: -30 200 C. 755254 755255 755256 755257 755258 755259 1/2 1 1 1/4 1 1/2 2 single jet single jet multi jet multi jet multi jet multi jet 11,5 12,5 13,5 16,0 10,0 15,0 240400 240500 240600 1/2 1 588 Three-piece straight union fitting Max. working pressure: 16 bar. Black nickel plated nut. 588052 588062 x M with union 1 F x M with union 5

PUMP STATIONS 267 Pump station for solar thermal systems, flow and return connection, with solar regulator. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Balancing valve with flow meter temperature range: -30 130 C. - Solar 15-80 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - balancing valve with graduated scale flow meter with magnetic movement flow rate indicator; - deaerator device; - flow temperature gauge; - return temperature gauge; - 2 shut-off valves and check valve; - pre-formed shell insulation; - digital regulator DeltaSol C+ with probes. 267 Pump station for solar thermal systems, flow and return connection. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Balancing valve with flow meter temperature range: -30 130 C. - Solar 15-80 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - balancing valve with graduated scale flow meter with magnetic movement flow rate indicator; - deaerator device; - flow temperature gauge; - return temperature gauge; - 2 shut-off valves and check valve; - pre-formed shell insulation. 267250 267254 267252 Flow meter scale (l/min) 2 17 3 10 7 25 267050 267054 267052 Flow meter scale (l/min) 2 17 3 10 7 25 6

PUMP STATIONS 266 Pump station for solar thermal systems, return connection, with solar regulator. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Balancing valve with flow meter temperature range: -30 130 C. - Solar 15-80 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - balancing valve with graduated scale flow meter with magnetic movement flow rate indicator; - return temperature gauge; - shut-off valves and check valve; - pre-formed shell insulation; - digital regulator DeltaSol C+ with probes. 266 Pump station for solar thermal systems, return connection. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Balancing valve with flow meter temperature range: -30 130 C. - Solar 15-80 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - balancing valve with graduated scale flow meter with magnetic movement flow rate indicator; - return temperature gauge; - shut-off valves and check valve; - pre-formed shell insulation. 266250 266254 266252 Flow meter scale (l/min) 2 17 3 10 7 25 266050 266054 266052 Flow meter scale (l/min) 2 17 3 10 7 25 7

PUMP STATIONS 269 Pump station for solar thermal systems, flow and return connection, with solar regulator. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Flow meter temperature range: -10 110 C. - Solar 15-65 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - flow meter; - deaerator device; - flow temperature gauge; - return temperature gauge; - 2 shut-off valves and check valve; - 2 hose connections; - pre-formed shell insulation; - digital regulator DeltaSol C+ with probes. 269 Pump station for solar thermal systems, flow and return connection. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Flow meter temperature range: -10 110 C. - Solar 15-65 circulation pump; - safety relief valve for solar thermal systems 253 series; - 2 fill/drain cocks; - instrument holder fitting with pressure gauge; - flow meter; - deaerator device; - flow temperature gauge; - return temperature gauge; - 2 shut-off valves and check valve; - 2 hose connections; - pre-formed shell insulation. 269250 269252 Flow meter scale (l/min) 1 13 8 30 269050 269052 Flow meter scale (l/min) 1 13 8 30 8

PUMP STATIONS 268 Pump station for solar thermal systems, return connection, with solar regulator. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Flow meter temperature range: -10 110 C. - Solar 15-65 circulation pump; - safety relief valve for solar thermal systems 253 series; - fill/drain cock; - instrument holder fitting with pressure gauge; - flow meter; - return temperature gauge; - shut-off valve and check valve; - 2 hose connections; - pre-formed shell insulation; - digital regulator DeltaSol C+ with probes. 268 Pump station for solar thermal systems, return connection. Safety relief valve temperature range: -30 160 C. Safety relief valve setting: 6 bar (for other setting, see 253 series using the adapter code F21224). Flow meter temperature range: -10 110 C. - Solar 15-65 circulation pump; - safety relief valve for solar thermal systems 253 series; - fill/drain cock; - instrument holder fitting with pressure gauge; - flow meter; - return temperature gauge; - shut-off valve and check valve; - 2 hose connections; - pre-formed shell insulation. 268250 268252 Flow meter scale (l/min) 1 13 8 30 268050 268052 Flow meter scale (l/min) 1 13 8 30 9

SPARE PARTS AND ACCESSORIES FOR PUMP STATIONS 259 tech. broch. 01136 Welded expansion vessel only for primary circuit of solar thermal systems. Diaphragm certified to DIN 4807-3 standard. Diaphragm max. temperature: 100 C. System temperature range: -10 120 C. DIGITAL REGULATOR 257 SOLCAL 1 Digital regulator Complete with wall mounting basis for plug-in electrical connection. Complete with three probes type Pt1000. Double relays output. Supply: 230 V ±6% - 50 Hz. Power consumption: 4 VA. Max. contact rating: 250 V (ac) - 8 (2) A. Protection class: IP 40. Litres Conn. 259012 259018 259024 259035 259050 12 18 24 35 50 Precharge (bar) 2,5 2,5 2,5 2,5 2,5 (h x w x d) 257041 90 x 136 x 80 255 tech. broch. 01136 Expansion vessel connection kit. - stainless steel flexible hose (L=610 mm); - automatic shut-off cock; - wall mounting bracket (for vessels up to 24 litres). Shut-off cock max. working temperature: 110 C. Characteristic components 255007 255010 255 System filling pump for pump stations 267, 266, 269 and 268 series. 11) LED 1: function error or probe fault (red) 12) LED 2: Solar circuit pump ON 13) LED 3: second relays output active 14) LED 4: OFF regulator non active 15) LED 5: ON regulator active 16) LED 6: active relays test 17) Storage temperature control setting at level 1, at level 2 depending on programme (see system) 18) T min. and max. control 19) Min. temperature control for solar panel activation and min. working time 10) Operation button Regulation programs The regulator allows to manage 11 regulation programs, depending on the possible system configurations. They can be used for systems with single or double storage, swimming-pools, heating or domestic water systems, etc.. Accessory for pump stations 267, 266, 269 and 268 series. To be used for the installation of the 1/2 safety relief valve 253 series. 257 Pocket for Pt1000 probe. In steel. Lenght: 100 mm. F21224 adapter 257004 1/2 10

DIFFERENTIAL REGULATORS AND THERMOSTAT 257 tech. broch. 01143 Differential temperature regulator for solar thermal systems, with relays output. Complete with contact probe and immersion probe with pocket. Box protection class: IP 65. Electric supply: 230 V ±6% - 50 Hz. Nominal power consumption: 1,45 VA. Contact rating on switch-over: 6 A (230 V). T adjustment range: 2 20 K. Hysteresis: 2 K (±1 K). 257001 (h x w x d) 200 x 122 x 112 257 tech. broch. 01143 Box complete with DIN bar, for regulator or thermostat 257 series. Protection class: IP 65. 257010 257 tech. broch. 01143 Double box complete with DIN bar, for regulator and thermostat 257 series. Protection class: IP 65. 257 tech. broch. 01143 Differential temperature regulator for solar thermal systems, with relays output. Box protection class: IP 65. Electric supply: 230 V ±6% - 50 Hz. Nominal power consumption: 1,45 VA. Contact rating on switch-over: 6 A (230 V). T adjustment range: 2 20 K. Hysteresis: 2 K (±1 K). 257003 (h x w x d)) 200 x 160 x 112 150 tech. broch. 01143 Contact probe for regulator or thermostat 257 series and for regulator 1520 series (flow or return). Cable lenght: 2 m. 257000 150009 257 tech. broch. 01143 Thermostat for solar thermal systems, with relays output. For thermal integration control and diverter valves. Box protection class: IP 65. Electric supply: 230 V ±6% - 50 Hz. Nominal power consumption: 1,45 VA. Contact rating on switch-over: 6 A (230 V). Adjustment temperature range: 20 90 C. Hysteresis: 1 K. 150006 150 tech. broch. 01143 Immersion probe for regulator or thermostat 257 series and for regulator 1520 series. Cable lenght: 2 m. 150 tech. broch. 01143 Pocket for immersion probe code 150006. 257002 150029 1/4 M 11

MECHANICAL FITTINGS WITH O-RING SEAL 2540 Female fitting, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 2546 Tee fitting, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 254055 254058 254052 254062 254068 - Ø 15 - Ø 18 - Ø 22 1 F - Ø 22 1 F - Ø 28 254602 Ø 22 2543 Coupling sleeve, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 2547 Male elbow fitting, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 254305 254308 254302 Ø 15 Ø 18 Ø 22 254755 254758 254752 M - Ø 15 M - Ø 18 M - Ø 22 254455 254458 254452 254465 254462 M - Ø 15 M - Ø 18 M - Ø 22 1 M - Ø 15 1 M - Ø 22 2544 Male fitting, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 2545 Elbow coupling sleeve, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 254855 254858 254852 - Ø 15 - Ø 18 - Ø 22 2548 Female elbow fitting, mechanical O-Ring seal For annealed copper, hard copper, brass, mild and stainless steel pipes. Max. working pressure: 16 bar. Black nickel plated nut. 2540 Plug for Ø 22 copper pipe. 254505 254508 254502 Ø 15 Ø 18 Ø 22 254002 Ø 22 12

COMPONENTS FOR SECONDARY CIRCUIT 13

THERMOSTATIC MIXING VALVE Sizing software available on www.caleffi.com 2521 tech. broch. 01127 Adjustable thermostatic mixing valve dezincification resistant alloy body. Chrome plated. Male union connections. Max. working pressure: 14 bar. Max. inlet temperature: 100 C. 2523 tech. broch. 01129 Thermostatic mixing valve with interchangeable cartridge Brass body. Male union connections. Max. working pressure: 14 bar. Max. inlet temperature: 110 C. 252140 252150 1/2 Temperature adjustment 30 65 C 30 65 C Kv (m 3 /h) 2,6 2,6 252340 252350 252360 252370 252380 252390 1/2 1 1 1/4 1 1/2 2 Temperature adjustment 30 65 C 30 65 C 30 65 C 30 65 C 35 65 C 35 65 C Kv (m 3 /h) 14,0 14,5 16,9 19,1 14,5 19,0 2521 tech. broch. 01127 Adjustable thermostatic mixing valve, with check valves, dezincification resistant alloy body. Chrome plated. Male union connections. Max. working pressure: 14 bar. Max. inlet temperature: 100 C. 252305 1/2-2523 Spare cartridge. For thermostatic mixing valve 2523 series. 2523 Spare cartridge. For thermostatic mixing valve 2523 series. 252153 Temperature adjustment Kv (m 3 /h) 30 65 C 2,6 252306 252308 1-1 1/4 1 1/2-2 Application diagram of mixing valve 2521 series 14

ANTI-SCALD THERMOSTATIC MIXING VALVE TEMPERATURE AND PRESSURE RELIEF VALVE 2527 tech. broch. 01165 Anti-scald adjustable thermostatic mixing valve, with check valves and strainers, High thermal performance device, with anti-scald safety function. dezincification resistant alloy body. Chrome plated. Male union connections. Performance to standards NF 079 Doc. 8, EN 15092, EN 1111, EN 1287. Max. inlet temperature: 100 C. 309 tech. broch. 01147 Temperature and pressure relief valve. For solar thermal systems, for protecting the hot water storage. dezincification resistant alloy body. Chrome plated. Setting temperature: 90 C. Discharge rating: 1/2 x Ø 15: 10 kw. x Ø 22: 25 kw. Settings: 6-7 - 10 bar. Settings certified to EN 1490: 7-10 bar. 252714 252713 1/2 Temperature adjustment 35 55 C 35 55 C Kv (m 3 /h) 1,5 1,7 309461 309471 309401 309561 309571 309501 1/2 M x Ø 15 6 bar 1/2 M x Ø 15 7 bar 1/2 M x Ø 15 10 bar M x Ø 22 6 bar M x Ø 22 7 bar M x Ø 22 10 bar MOTORISED BALL DIVERTER VALVE ANTI-FREEZE SAFETY DEVICE 6443 tech. broch. 01132 Motorised three-way ball diverter valve. Max. p: 10 bar. Temperature range: -5 110 C. Complete with actuator with 3-contact control. With auxiliary microswitch. Power consumption: 8 VA. Auxiliary microswitch contact rating: 0,8 A (230 V). Ambient temperature range: 0 55 C. Protection class: IP 44 (vertical stem). IP 40 (horizontal stem). Operating time: 10 s (90 rotation). Cable lenght: 100 cm. 603040 1/2 F with nut 603 ICECAL Anti-freeze safety device. For solar thermal systems, to protect the hot water storage. dezincification resistant alloy body. Ambient temperature range: -30 90 C. Opening temperature: 3 C. Closing temperature: 4 C. Application diagram of device 603 series on a domestic water circuit 644346 644356 644357 644366 1/2 1 Electric supply V 230 230 230 230 Kv (m 3 /h) 3,9 3,9 8,6 9,9 15

Application diagram of SOLARNOCAL kit 264 series SOLAR STORAGE-TO-BOILER CONNECTION KIT 264 tech. broch. 01163 SOLARNOCAL Function A thermostatic anti-scald mixing valve, at the kit inlet, controls the temperature of the water coming from the solar hot water storage. The thermostat, by means of the probe positioned on the hot water flow from the solar hot water storage, controls the diverter valve at the kit outlet. Depending on the temperature setting, the valve diverts the water towards the user circuit or activates the boiler circuit, without thermal integration. Hydraulic diagrams Solar storage-to-boiler connection kit, without thermal integration. - thermostatic anti-scald mixing valve, adjustable with knob, Complete with strainers and check valves at the inlets; - diverter valve with three-contact actuator, with auxiliary microswitch; - thermostat with probe for solar thermal system, for operating diverter valve. Display showing temperature. - pre-formed shell protective cover. Diverter-mixing valve coupling with adjustable position of the inlet and outlet connections. Mixing valve dezincification resistant alloy body. Adjustment temperature range: 35 55 C. Max. inlet temperature: 100 C. Diverter valve Brass body. Temperature range: -5 110 C. Actuator Three-contact type. Power consumption: 8 VA. Auxiliary microswitch contact rating: 0,8 A (230 V). Ambient temperature range: 0 55 C. Protection class: IP 44 (vertical stem). IP 40 (horizontal stem). Operating time: 10 s. Cable lenght: 1 m. Thermostat with probe BOILER Adjustable temperature range: 25 50 C. Factory setting: 45 C. COLD Box protection class: IP 54. COLD BOILER MIXED 264352 SOLAR USER OUTLET SOLAR USER OUTLET SOLAR USER OUTLET T SOLAR > 45 C SOLAR USER OUTLET T SOLAR < 45 C 16

SOLAR STORAGE-TO-BOILER CONNECTION KIT 265 tech. broch. 01163 SOLARINCAL Function The thermostat, by means of the probe positioned on the hot water flow from the solar hot water storage, controls the diverter valve at the kit inlet. Depending on the temperature setting, the valve diverts the water towards the user circuit or the boiler circuit, with thermal integration. A thermostatic anti-scald mixing valve, at the kit outlet, constantly controls the temperature of the water sent to the user. Hydraulic diagrams Solar storage-to-boiler connection kit, with thermal integration. - thermostatic anti-scald mixing valve, adjustable with knob, Complete with strainers and check valves at the inlets; - diverter valve with three-contact actuator, with auxiliary microswitch; - thermostat with probe for solar thermal system, for operating diverter valve. Display showing temperature. - pre-formed shell protective cover. Diverter-mixing valve coupling with adjustable position of the inlet and outlet connections. Mixing valve For technical details see 264 series. Diverter valve For technical details see 264 series. Actuator For technical details see 264 series. Thermostat with probe Adjustable temperature range: 25 50 C. Factory setting: 45 C. Box protection class: IP 54. 265352 ACCESSORIES 265001 265 BOILER Thermostat with display showing storage temperature. For devices 264 and 265 series. Electric COLD supply: 230 V (ac). COLD Adjustable temperature range: 25 50 C. Factory setting: 45 C. Box protection class: IP 54. MIXED SOLAR MIXED BOILER SOL Application diagram of SOLARINCAL kit 265 series 264359 265359 F29525 F29488 257004 T SOLAR > 45 C kit 264 series without thermostat and probe kit 265 series without thermostat and probe box with switching 3 contact relay Ø 6 mm probe stainless steel pocket for Pt1000 probe T SOLAR < 45 C 17

SOLAR STORAGE-TO-BOILER THERMOSTATIC CONNECTION KIT 262 tech. broch. 01164 SOLARINCAL-T Function A thermostatic diverter valve, at the kit inlet, receives hot water coming from the solar water storage. Depending on the temperature setting, the valve diverts the water automatically and in a proportional manner towards the user circuit or the boiler with storage circuit, with thermal integration. The valve modulates the flow rates to optimise the energy contained in the solar storage and reduces boiler operation times to a minimum. A thermostatic anti-scald mixing valve, at the kit outlet, constantly controls and limits the temperature of the water sent to the user. Solar storage-to-boiler connection kit, with thermal integration. - thermostatic anti-scald mixing valve, adjustable with knob, Complete with strainers and check valves at the inlets. - thermostatic diverter valve; - pre-formed shell protective cover. Diverter-mixing valve coupling with adjustable position of the inlet and outlet connections. Mixing valve dezincification resistant alloy body. Adjustment temperature range: 35 55 C. Max. inlet temperature: 100 C. Performance to standards NF 079 doc. 8, EN 15092, EN 1111, EN 1287. Diverter valve Brass body. Factory setting: 45 C. Max. inlet temperature: 100 C. Hydraulic diagrams 262350 Application diagram of SOLARINCAL-T kit 262 series 18

SOLAR STORAGE-TO-BOILER THERMOSTATIC CONNECTION KIT 263 tech. broch. 01164 SOLARINCAL-T PLUS Function A thermostatic diverter valve, at the kit inlet, receives hot water coming from the solar water storage. Depending on the temperature setting, the valve diverts the water automatically and proportionally towards the user circuit or the instantaneous boiler circuit, with thermal integration. The valve modulates the flow rates to optimise the energy contained in the solar storage and reduces boiler operation times to a minimum. A specific thermostatic control device limits the boiler inlet temperature to prevent it being switched on and off too often, which leads to hunting and irregular operation. A thermostatic anti-scald mixing valve, at the kit outlet, constantly controls the temperature of the water sent to the user. Solar storage-to-boiler connection kit, with thermal integration. - thermostatic anti-scald mixing valve, adjustable with knob, Complete with strainers and check valves at the inlets; - thermostatic diverter valve; - thermostatic control device; - pre-formed shell protective cover. Mixing valve dezincification resistant alloy body. Adjustment temperature range: 35 55 C. Max. inlet temperature: 100 C. Performance to standards NF 079 doc. 8, EN 15092, EN 1111, Diverter valve dezincification resistant alloy body. Factory setting: 45 C. Max. inlet temperature: 100 C. Control device dezincification resistant alloy body. Factory setting: 30 C. Max. inlet temperature: 85 C. Hydraulic diagrams 263350 Application diagram of SOLARINCAL-T Plus kit 263 series 19

0311712GB Caleffi S.p.A. S.R. 229 n. 25 28010 Fontaneto d Agogna (NO) Italy Tel. +39 0322 8491 Fax +39 0322 863723 info@caleffi.com www.caleffi.com Copyright 2012 Caleffi