Agilent Biomass Solutions SUSTAIN YOUR PRODUCT QUALITY AND COMPETITIVE EDGE

Similar documents
Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Accuracy Starts Here. Agilent Captiva Filtration Selection Guide

Alliance HPLC DEFINED BY DEPENDABILITY, TODAY AND IN THE FUTURE

breakthrough versatility

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

TSHR 6000 series TN/TS/TX analyzer

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Monitor Chlorine in Crude at Sub-ppm Levels

Elemental Analysis Advanced

Determination of Free and Total Glycerin in B100 Biodiesel

Using the PSD for Backflushing on the Agilent 8890 GC System

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Agilent and ASTM. Update on Recent Activities. Page 1

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Application Note. Author. Introduction. Energy and Fuels

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

MET-Biodiesel Capillary GC Columns

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Application Note. Abstract. Authors. Environmental Analysis

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Determination of Phenolic Antioxidant DBPC and DBP Levels in Electrical Insulating Oil

TSHR 7000 series TN-TS-TX analyzer

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Technical Procedure for Gas Chromatography (GC-FID)

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Application Note. Authors. Abstract. Energy & Chemicals

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Chemical and Petrochemical Applications of Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Simultaneous Determination of Fatty Acid Methyl Esters Contents in the Biodiesel by HPLC-DAD Method

Refinery and Natural Gas Analysis

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

White Paper.

The next level of True Blue Performance

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Low cost EDXRF elemental analyzer

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

The Analysis of Biodiesel for Trace Metals and the Development of Certified Biodiesel Standards

X-ray Essentials from XOS Proven Performance

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Application. Gas Chromatography June 1995

lubricants analysis. complete solutions for your lab. Lubricants Analysis

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

High-Performing Restek PAL SPME Fibers

S-PRO 3200 GC System for Sulfur Analysis

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

Ultra High Performance Fittings. Fittings Connectors Kits

C2, C3, C4 Monomer Analysis

Antek Gas Chromatography Products: A Guided Tour Through Industry

built for the next generation Cat

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Technical Overview. Introduction

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Practical Steps in GC Troubleshooting

The Analysis of Biodiesel for Inorganic Contaminants, including Sulfur, by ICP-OES

Agilent Multimode Inlet for Gas Chromatography

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

WASTE TO ENERGY. Commercial Enzymatic Production of Biodiesel

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

MEASURE. BIOFUEL PARAMETERS When and Where You Need To. Coen Duvekot Product Marketing Manager, MicroGC

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Meeting the Requirements of ASTM D ( IP548/06 ) with Agilent 1200 LC Systems

Optimization of the Temperature and Reaction Duration of One Step Transesterification

GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies

Beverage Grade Carbon Dioxide

High-Temperature Simulated Distillation System Based on the 6890N GC Application

On-Line NIR Analysis for Blending

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

Analytical and Testing Instruments for Renewable Fuels. Shimadzu s Analytical Solutions for the Renewable Fuels Industry

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Determination of Sudan Dyes I IV in Curry Paste

Transcription:

Agilent Biomass Solutions SUSTAIN YOUR PRODUCT QUALITY AND COMPETITIVE EDGE

Agilent Biomass Solutions Promote clean, sustainable fuel for our planet and energy independence for its people Global warming, trade deficits, environmental concerns, political instability, and other issues are driving dramatic changes in the energy and chemical industries. The world is looking for reliable, clean, and sustainable energy sources and is turning to biomass as an answer. Powering the future by taking a lesson from the past Simply stated, biomass is any plant or animal material of recent origin, as opposed to plant or animal material that, over millennia, has transformed into oil, coal, tar sands, natural gas, or other petroleum products. Biomass materials are remarkably versatile, and have been used throughout the history of civilization. Early humans, for example, used wood biomass as a fuel for fire, and clothes have been made from cotton fiber biomass for centuries. Today, however, biomass is taking on a truly revolutionary role, inspiring new industries dedicated to providing the energy we need without harming the environment. Every year, biofuels are growing more attractive as viable supplements or alternatives to petroleum-based fuels, which continue to increase in price and rely on a dwindling supply of crude oil. Although numerous technologies are under development for converting biomass to fuels and chemicals, they all follow the same basic procedure. BIOMASS FEEDSTOCK Examples Algae Corn Sugar cane bagasse Switch grass Tallow Wood TRANSFORMATION PROCESS Examples Fermentation Catalysis Chemical Enzymes extraction Combustion Pyrolysis Catalysis Enzymes Chemical Fermentation extraction Pyrolysis FINAL PRODUCT Examples Biodiesel Butanol Ethanol Ethylene Heat Syngas 2

Meeting rigorous analytical requirements For biomass fuels to be acceptable as replacements for petroleum, they must conform to industry requirements throughout the manufacturing chain. Testing protocols typically fall into four areas: 1. Raw material quality: Carbohydrate, protein, and fat assays directly impact the market price of biomass feedstock. 2. Process control: Measuring the conversion to fuel during plant production is critical for optimizing economics. 3. Fuel product certification: Recognized quality standards must be met before the final product enters the fuel supply. 4. Field operations/monitoring: The blending of biofuel into traditional petroleum products must be monitored at terminals and advertised content must be enforced at the point of sale. Since the majority of tests are routine and likely to be performed by non-scientific personnel, analytical instruments must be fast, accurate, safe, and easy to operate. You can count on Agilent for the technical capabilities and expertise you need to meet these difficult analytical challenges. On the following pages, you ll find the Agilent technologies that can help usher in and sustain an era of clean, renewable, energy and chemical resources. HPLC systems 4 Deliver ultimate resolution and sensitivity GC analyzers 5 Fast results for confident certification High-performing FTIR instruments 6 Suitable for routine and research analysis MP-AES systems 7 A cost effective and efficient alternative to flame AA for elemental analysis of biofuels ICP-MS systems 8 Monitor trace metals in organic matrices Sample Prep WorkBench 8 Faster, more consistent sample prep Columns and supplies 9 Reproducible results and trouble-free instrument performance Service and support 12 Providing you with unparalleled expertise and service To learn more about Agilent biomass technologies and applications, visit agilent.com/chem/energyandfuels 3

Agilent Biomass Solutions Agilent 1260 Infinity LC system Infinitely better feedstock quality and process control Agilent s 1260 Infinity LC system raises the standard of HPLC with new levels of productivity, data quality, and robustness. 600 bar standard pump pressure, 80 Hz standard detector speed and up to 10 times higher UV detection sensitivity prepare you for today s challenges and tomorrow s 100% compatible with your HPLC and RRLC methods ensuring no-risk instrument replacement Enhanced UHPLC capability for HPLC price Dramatically increased sensitivity with flat baselines for DAD-based analyses Conditions Sample: Column: Sample size: Mobile phase: Flow rate: Injection volume: Temperature: 85 C Detector: RI Sugars and sugar alcohols Agilent Hi-Plex Ca, 7.7 300 mm, 8 μm (p/n PL1170-6810) 10 mg/ml 100% DI H 2 O 0.6 ml/min Compound list 10 μl 1 Raffinose 2 Sucrose 3 Lactulose 4 Glucose 5 Galactose 2 6 Fructose 1 7 Ribitol 8 Mannitol 3 7 9 Sorbitol 4 5 6 8 9 0 min 30 LC separation of a sugar/sugar alcohol mixture using an Agilent Hi-Plex Ca column. With a range of ligand counter ions for optimum selectivity and with resolution and materials matched to USP definitions of media types L17, L19, L34, and L58 the Hi-Plex column family is ideal for isocratic separations using water or dilute acid as the eluent. The 1260 Infinity LC lets you monitor process lines, ensure proper feed rates, and gather intelligence on competitive products. 4

Agilent Biofuel GC Analyzers Be confident that your final product conforms to industry quality standards Finished biofuel must undergo extensive analysis before it can be sold. Agilent s factory-tested and pre-configured biodiesel analyzers conform to ASTM and CEN standard methods, helping you comply with stringent regulations for FAMEs analysis, glycerin and glyceride determination, and trace methanol measurement. Each analyzer arrives ready to run your application with proven analysis methods and checkout samples that can reduce method development costs by up to 90%. All columns and supplies you need for out-of-the-box setup and operation are included, so you can get started quickly. Optional Deans Switch allows cost-effective 2-D GC analysis of biodiesel blends with no sample preparation. Compounds that might co-elute on the first column are separated from the analyte on the second column, which has a different stationary phase. This configuration conforms to the ISO EN 13132 method. pa 90 7890B GC Ethanol 13.58 min 80 70 60 50 Methanol 11.54 min 40 30 20 10 10 15 20 25 30 35 40 min Analysis of a commercial denatured fuel ethanol sample using an Agilent 7890B GC system configured to run ASTM method D5501-09. The system showed no inlet discrimination, allowing compounds with wide boiling ranges to be quantitatively transferred to the column. Agilent biomass analyzers are engineered to meet or exceed these industry standards ASTM D6584 ASTM D4815 ASTM D5501 ASTM D7754 EN 14103 EN 14106 EN 14110 EN 14105 To learn more about Agilent biomass technologies and applications, visit agilent.com/chem/energyandfuels 5

Agilent Biomass Solutions Agilent FTIR systems Pushing the limits of monitoring for biodiesel and ethanol methods Fourier Transform Infrared spectroscopy (FTIR) is the preferred technique for identifying unknown materials in the lab or in the field, because of its ability to analyze functional groups and produce a unique spectroscopic fingerprint. A new method for quantifying biodiesel in diesel fuel using Agilent s 5500t FTIR We combined the transmission sample interface specified in EN 14078 with the algorithm and standards specified in ASTM D7371 to develop a method that accurately predicts the percentage of biodiesel in diesel fuel from 0.025% to 20%. The method accuracy was tested and found to be superior to other methods, especially for low levels of biodiesel, as you can see below. The 4500 / 5500 and Cary 630 series Dialpath and TumblIR FTIR systems also conform to the new ASTM D7806 transmission Mid-IR biodiesel in diesel standard. Agilent s FTIR portfolio complements our best-in-class GC analyzers for bioanalysis applications. Our Cary 630 FTIR makes complex calibrations simple, providing users with versatility for measurement of both EN and ASTM methods just by changing the sample interface. The rugged design of the 4500 and 5500 series FTIR lets you take measurements in places you didn t think possible loading docks, out in the field, or even in the back of a truck. The mobile FTIR (4500 / 5500) and in-lab Cary 630 fuel analysis package includes an extended 0-100% range ethanol in gasoline measurement designed for very accurate E85 fuel testing. Absorbance 0.11 0.10 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0.00 Ester Carbonyl, Biodiesel 1800 1790 1780 1770 1760 1750 1740 1730 1720 1710 1700 1690 1680 1670 1660 1650 1640 1630 1620 Wavenumber (cm -1 ) Overlaid IR spectra of diesel fuels with ultra-low concentrations of biodiesel: 0.50% (blue), 0.10% (light green), 0.05% (red), 0.025% (maroon), and 0.00% (dark green). Note: Aged Gasoline, EtOH, Light Aromatics, and Light Aliphatics Evaporated, Measured on the Multireflection 5500a Gasoline Method The Cary 630, 4500 and 5500 FTIR all run on MicroLab software. MicroLab displays and reports the quantitative results along with color-coded alerts if a sample is out of specification. Range SECV R^2 #Validation Samples Avg. Relative Error 0.025-1% 0.0016% 0.9999 29 1.37% 1%-10% 0.0164% 0.9999 12 0.06% 10%-20% 0.04% 0.9999 8 0.57% Here, we used cross validation data to calculate the standard error of cross validation (SECV) and to prepare an actual versus predicted plot. The correlation of the actual versus predicted plot was also calculated. Versatile, innovative, and intuitive: The Cary 630 provides superior quantitative and qualitative information for routine analysis Compact and Powerful: Agilent s 4500 and 5500 series FTIR let you make real-time, on-site decisions. 6

Agilent 4200 MP-AES Analyze a broader range of samples while benefiting from the lowest cost of ownership The Agilent MP-AES is a suitable cost effective and efficient alternative to flame AA for elemental analysis of biofuels. Simple dilute and shoot methods using this instrument are applicable for both biodiesel and ethanol analyses. The Agilent 4200 MP-AES delivers: Lowest cost of ownership the Agilent 4200 MP-AES runs unattended without flammable or expensive gas supply, dramatically reducing your operating costs. Improved laboratory safety in addition to eliminating flammable and oxidizing gases, the 4200 MP-AES eliminates the need to plumb multiple gases into the laboratory, or manually transport and handle gas cylinders. High-performance the microwave plasma source provides superior detection limits to flame AA. Ease of use application-specific software applets plus plug-andplay hardware ensure any user can set up quickly without method development or alignment, and with minimal training. Robustness and reliability ideal for chemicals, petrochemicals, and manufacturing industries, and for use in remote locations. Figures of merit for Cr, Ni, Pb, V, and Si determination by MP-AES technology. Element LOD* (μg/l) LOQ* (μg/l) LOD in the sample (μg/kg) Cr 0.7 2.2 9 Ni 16 52 200 Pb 40 130 490 V 0.3 0.9 4 * Instrumental limits of detection and quantification. Limit of detection considering sample dilution (1:9 v/v ethanol fuel in HNO 3 1% v/v). From Application Note: 5991-0771EN HNO 3 1% v/v Micro-emulsion LOD (μg/l) LDR a (Decades) RSD b (%) LOD (μg/l) LDR a (Decades) RSD b (%) Si (251.611 nm) 20 2.3 1.6 5 2.6 1.6 Si (288.158 nm) 240 0.9 1.3 5 2.5 0.4 a = Linear dynamic range starting at the limit of detection. b = Repeatability presented as the relative standard deviation for a 2 mg/l Si solution (n = 10). From Application Note: 5991-0490EN To learn more about Agilent biomass technologies and applications, visit agilent.com/chem/energyandfuels 7

Agilent Biomass Solutions Agilent 7900 ICP-MS Streamlined technology that simplifies your measurement of trace elements From feedstock process monitoring to quality control, ICP-MS is an excellent tool for the elemental analysis of biofuels. Specifically, it can help you meet requirements for: Detecting contaminants, such as sulfur, catalyst residues (usually Na and K), and catalyst poisons (typically lead, vanadium, and mercury). Monitoring the levels of common fuel additives, such as silicon (anti-foaming agent), manganese (burn improver), and chromium, iron, and nickel (for marine applications). Agilent s 7900 ICP-MS delivers accurate elemental concentrations from ppt to % levels with minimal sample preparation. Interferences from complex, carbon-based samples are removed reliably by the revolutionary 4th generation collision/reaction cell the ORS 4. With automated setup, faster analysis, better interference removal, and a simplified MassHunter software interface, the Agilent 7900 ICP-MS blends high performance with unprecedented ease-of-use. Agilent 7696A Sample Prep WorkBench Automate GC and LC sample and standards prep Manual sample prep can be time-consuming and inconsistent, leading to rework and wasted supplies. Agilent s 7696A Sample Prep WorkBench eases these frustrations by: Decreasing sample carryover Minimizing variability between analysts Reducing the need for costly rework Lowering safety risks Reducing solvent, reagent, and glassware costs by performing all operations in a 2 ml vial Reducing costs over time Best of all, the 7696A Sample Prep WorkBench can actually pay for itself through reduced analyst time and labor costs. pa 150 100 50 pa 150 100 50 pa 150 100 50 pa 150 100 50 Glycerin Monoglycerides Diglycerides Triglycerides Chemist 1 Chemist 2 Chemist 3 Chemist 4 2.5 5 7.5 10 12.5 15 17.5 20 22.5 A comparison of data from a soybean biodiesel sample prepared by using ASTM method D6584 on the Agilent Sample Prep WorkBench. Min 8

Agilent Columns and Supplies The right columns and supplies help you produce the right numbers under demanding deadlines Agilent-engineered columns and supplies keep your methods safe, your workflow running smoothly, and contamination to a minimum. They are registered to ISO 9001 standards to ensure maximum instrument performance and reproducible results. Agilent LC columns Agilent LC columns are optimized for high throughput analysis (Fast LC), and feature the sensitivity, accuracy, and reliability that demanding applications require. Agilent ZORBAX and Poroshell columns give you: The productivity you need to increase lab throughput: Technological advances like sub-2 μm particles and superficially porous Poroshell 120 columns increase speed and resolution. Unbeatable chromatographic performance: ZORBAX silica the base silica used for all ZORBAX and Poroshell 120 columns is ultra-pure, very strong, and highly uniform for ultimate reliability. Assured selectivity to suit your separation, via the broadest range of chemistries and column configurations. You will find that Poroshell 120 columns provide exceptional efficiency for standard HPLC and UHPLC instruments. Poroshell 120 family highlights: Extraordinary lot-to-lot reproducibility: manufactured using a proprietary single-step porous shell process that dramatically reduces minute differences between columns and lots. Comparable speed and resolution to sub-2 μm columns with up to 50% less backpressure: take HPLC and UHPLC performance to a new level of flexibility and efficiency. Superior peak shape: for faster, more accurate results. Long column life: a standard 2 μm frit is used and resists plugging with dirty samples. TWELVE chemistries, including SB-C18 and SB-C8 for low ph applications and HPH-C18 and HPH-C8 for high ph applications. Easy method transfer and scalability to ZORBAX bonded phases, for highest productivity. Reduced operating expenses with Fast Guards for UHPLC. Find the best column for your separation with the Agilent LC Column Navigator: agilent.com/chem/navigator To learn more about Agilent biomass technologies and applications, visit agilent.com/chem/energyandfuels 9

Agilent Columns and Supplies Agilent J&W GC columns These columns give you excellent performance for benign and difficult samples. With the best inertness, lowest bleed levels, and the tightest column-to-column reproducibility, they outperform any other column on the market. Ruggedness and reliability to meet your lab s demands From product quality and safety to price-driven efficiency improvements to environmental stewardship the pressure to stay productive, profitable, and compliant is more intense than ever. You simply do not have room in your day for downtime caused by problems with your analytical column. Porous layer open tubular (PLOT) columns are the GC columns of choice for the analysis of light gases and volatile compounds because of their high retentive character, and therefore, have been widely adopted in the hydrocarbon processing industry. However, the stationary phase layer in many PLOT columns is not mechanically stable resulting in particle shedding which can adversely affect your analysis. Likewise, if you use Sulfur Chemiluminescence Detection (SCD) to analyze sulfur compounds in natural gas, petroleum products, and process streams, you may have experienced detector sensitivity issues. Column bleed from thick film polydimethylsiloxane (PDMS) phases, which are commonly used, can contribute to fouling phenomena on SCD ceramic burner tubes. This leads to frequent and costly tube replacement and associated downtime. In addition, since light sulfur gases are reactive, flow path inertness is critical to avoiding peak tailing. But the good news is Agilent has developed two new column technologies specifically designed to reduce GC system downtime and maintenance, while expanding your lab s analytical capabilities. Reduce maintenance costs and extend your capabilities with Agilent J&W PLOT PT GC columns New integrated particle-trapping technology on both ends of Agilent J&W PLOT PT GC columns minimizes particle shedding in all applications. That means you can worry less about signal spiking and unnecessary downtime. Our particle-trapping design also takes the worry out of performing GC or GC/MS analysis with PLOT columns for more confident identification of unknowns. Greatly improve SCD stability with Agilent J&W DB-Sulfur SCD columns These new columns are optimized for low bleed, which reduces fouling of SCD ceramic tubes minimizing instrument downtime and operational costs. In addition, Agilent J&W DB-Sulfur SCD columns provide excellent peak shape and extended detector stability for all GC SCD methods that utilize PDMS stationary phases such as ASTM D 5623 and 5504. 10

Agilent liners, vials, septa, ferrules, and other supplies All Agilent supplies are engineered or selected by our experienced instrument design teams, manufactured to our demanding specifications, and tested under the strictest conditions. MS-certified split and splitless liners Tested with FID and MSD to ensure inertness, purity, and consistency; deactivated using a proprietary Agilent liquid deactivation process Vespel/graphite ferrules Manufactured to the ideal hardness for GC/MS applications to prevent contamination caused by flaking Certified vials Work flawlessly with your autosampler s gripping and injection mechanisms eliminating breakage and leaks that can cause unnecessary downtime, expensive repairs, and sample loss Premium non-stick septa Plasma coated to eliminate chemical bleed and contamination, so your GC system will stay cleaner and require less maintenance Self Tightening Column Nut Leak-free seal, even at high temperatures Easy finger-tight design no retightening needed Available for the inlet, detector and the MS transfer line Renewable Gas Purification System Prevents bleed and sustains column performance by improving the quality of gas that enters the column PEEK or stainless steel LC tubing Eliminates dead volumes while making sure your connections are inert, tight, and leak-free ICP-MS sampling and skimmer cones From our proprietary ICP torch to our skimmer cones, Agilent ICP-MS parts and supplies are rigorously tested to ensure that you ll always get the best performance from your instrument To learn more about Agilent biomass technologies and applications, visit agilent.com/chem/energyandfuels 11

Agilent is uniquely equipped to support your Biofuels efforts with unmatched expertise, training, and services For more information Learn more agilent.com/chem/energyandfuels U.S. and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacific inquiry_lsca@agilent.com Agilent Advantage Service and Support Whether you need support for a single instrument or a multi-lab, multi-vendor operation, Agilent helps you solve problems quickly, increase your uptime, and optimize your resources from installation and upgrade to operation and repair. Agilent Value Promise We guarantee you at least 10 years of instrument use from your date of purchase, or we will credit you with the residual value of the system toward an upgraded model. Agilent Service Guarantee If your Agilent instrument requires service while covered by an Agilent service agreement, we guarantee repair or we will replace your instrument for free. No other manufacturer or service provider offers this level of commitment to keeping your laboratory running at maximum productivity. In other countries, please call your local Agilent Representative or Agilent Authorized Distributor visit agilent.com/chem/contactus This information is subject to change without notice. Agilent Technologies, Inc. 2014 Printed in the USA August 11, 2014 5990-9648EN