Low Voltage Lighting Power Supplies

Similar documents
General Purpose Buck - Boost Wiring Diagrams... 86

Planning Low Voltage Layouts

SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View

Features, Benefits and Functions

HPS Fusion General Purpose Enclosed Transformer

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Single-Phase Ventilated

Midwest Dry Type Transformers

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Transformers 6. Gross Automation (877)

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Wiring Diagram Number

TA Ta VA CTRL-XFRMR

Industrial Control Transformers

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection.

B BASIC HEAT TREATMENT CONSOLE

Dry-Type Transformers Mini-Power Centers

Three-Phase Ventilated

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

SECTION PANELBOARDS

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

Totally Enclosed Non-Ventilated

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

MLT T-RPC. Supplied with mounting plate & hardware for easy installation (key slotted back)

Individual & fixed bank capacitors

Electrical Design/Build Guide

INSTALLATION INSTRUCTION Magnetic Transformer

OUTDOOR TRACK. LABELS Assembled in America

SURE TRIP RETRO KITS

HIGH INTENSITY DISCHARGE BALLASTS

Industrial Control Power Transformers Class MT

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Recreational Vehicle Park Electrical Products & Accessories

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

3. Coils shall be of molded construction

Transformer Disconnects

Installation Manual. CS9300 Professional Series Landscape Lighting System

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Enclosures. See Section Typical Description

4" Motors and Controls

LED Auxiliary Devices

BF Series Flasher Thermal flasher circuitry

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

SURE-TRIP OEM RELACEMENT TRIP UNIT

Design Standard. Purpose: Design Standard:

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

Tanning Bed Transformers

MODEL 422 Submersible Pump Controller

Three Phase Transformers

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Non-Ventilated Automation Transformers 6

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

SPEQ -S. Small Cylinder Track Head

Modifiable TITAN Horizontal Motors Accessories and Modifications

Industrial Control Power Transformers

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

AUXILIARY ELECTRIC HEATER KITS FOR 7.5, 10, 15 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE

Electromagnetic Fluorescent Ballasts

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

Dry Type Distribution Transformers

PH250MQMJ CNTL 250VA 240X X240

Medium Voltage Metal-Enclosed Switches

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

EPS-ECONOMY PUMP STARTER

Product guide. Enclosed NEMA starters. Answers for industry.

Softstarters Type PSS. Softstarters. General information

FORM NO. HSC-543 AIR HANDLERS

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Dry Type Distribution Transformers

Medium Voltage Metal-Enclosed Switches

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual

Product Guide. enclosed NEMA STARTERS

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Ballasts For High Intensity Discharge Lamps

Dry Type Distribution Transformers

Bulletin 1497A Machine Tool Transformers

HPS Fusion General Purpose Enclosed Transformer

Control Circuit Transformers

Typical Applications. Horizontal Installation

AFL FLOODLIGHT SERIES

Single-Phase Step Voltage Regulators

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Dry Type Distribution Transformers

IEC Utilization Categories (Explanation)

Pretest Module 24 Three-phase Service Entrance

Transcription:

SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES Low Voltage Lighting Power Supplies A greater selection for your indoor and outdoor low voltage lighting projects hy Low Voltage? Acme s Low Voltage Lighting products provide a safe, long lasting, highly reliable power source; a perfect selection for landscape applications as well as interior use. Low voltage lighting is a creative medium with unlimited application possibilities. Low voltage lighting benefits include: Precision beam control More light intensity per watt Less radiated heat Greater efficiency Longer life Safer to use Easy installation A high return on end-user investment Acme Advantages Greater selection Acme offers one of the largest selections of low voltage lighting transformers in the industry. The addition of our premium line (Group I) that includes a photocell and 24-hour timer and the versatile Group V transformers gives the landscape architect or contractor almost unlimited application possibilities. Please use the convenient Selection Guide on the facing page to aid in your selection. More value Acme low voltage transformers and power supplies are available in a wide range of options and models that are all UL listed for use indoors or outdoors. All Acme products are backed by a 10-year limited warranty (see inside back cover for details). More Power Power supplies are available in ratings of 100 through 1500 and transformers in ratings of 100 through 1000 ; Group VI Buck Boost in.05 through 10 KVA. More convenience Screw lug output terminals on Group I, II and III power supplies provide fast low voltage connections regardless of transformer location. Just slip your wires into the lug and tighten there s no wrapping the wire around a screw post. Groups IV, V and VI transformers have copper lead wires for hardwiring. Circuit breakers for instant reset (except pool and spa and Buck Boost). No fumbling with fuses. Generous wiring compartment, too! More protection A full fault current carrying Faraday Shield (except Buck Boost) prevents 120 volts from reaching the 12 volt side, as required by UL-1571 and UL-1838. Features and Options The convenient Selection Guide on the facing page provides you with the data you need to select the product that best meets your requirement. Complete product selection data, dimensions and wiring diagrams are contained on the following pages. If you need help in your selection, or if you have questions, just call technical services at 1-800-334-5214. 86

SECTION VI LO VOLTAGE LIGTING TRANSFORMERS & POER SUPPLIES SELECTION GUIE 2 3 4 5 6 7 8 9 Tap Switch Standard 11,12,13V or on all No No No No 12/ 11/22, 12/24, 13/26 Units 10 11 POER SUPPLIES TRANSFORMERS GROUP I GROUPS II & III GROUP IV GROUP V GROUP VI TLV and Pool and Spa Buck Boost Features/Options TLVA T T and T-1 T-1 T-1 and T-2 Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 1 100 100 100, 300 100.05 Ratings through through and through through (atts, VA, KVA) 600 atts 1500 atts 500 atts 1000 VA 10 KVA 24 our Timer Standard and Photocell on all units Primary Input 120 Volts 120 Volts 120 Volts Secondary Output No No No No 120 Volts or 120 x 240 240 Volts Volts Selection of Selection of 12, 13, 14 V or dual or dual taps or 12 x 24 V 12/24 V units 12/24 V units provided Primary Line Cord Standard Optional 6 with Plug 6 through 500 No No No ardwired Primary NA Optional Yes Yes Yes Auto Thermal Reset Auto Thermal Reset Auto Thermal Auto Thermal Reset No Overload Primary through 300 through 250 Reset Protection: Secondary Circuit Optional Circuit Breaker (s) Circuit Breakers No Breakers No (Group II) Output Screw Lug Screw Lug Copper Copper Copper iring Terminals Terminals Lead ires Lead ires Lead ires On Off Auto Switch Standard on all units No No No No UL Listed Yes Yes Yes 3 Yes Yes 12 13 14 15 CSA Certified No No No Yes Yes Faraday Shield Product arranty Yes Yes Yes Yes No 10 Years 1 10 Years 10 Years 10 Years 10 Years UL-3R Indoor/Outdoor Yes Yes Yes 2 No Yes Enclosure 1 Timer and Photocell limited to 3 years. 2 Standard Pool and Spa enclosure is painted cold-rolled steel. Stainless steel enclosure is available. 3 UL listed for use with low voltage submersible lights. 87

ow To Size Your Power Supply Easy Two-Step Selection 1. Add the total lamp wattage of each circuit you plan to use. For example: if you have 2 circuits, each with four 25 watt lamps, your total wattage is: 2 circuits x 4 lamps = 8 lamps x 25 watts = 200 watts. 2. Go to the appropriate selection chart. The catalog number identifies the power supply size and output voltage (see example below). You won t find the exact 200 watts needed, so go to the next highest catalog number TLV-25012-S. This leaves you 50 watts of reserve power available for other low voltage applications. See chart below for recommended wire sizes and voltage drop. If you use a power supply with a dual 12/24 volt secondary, each 12 volt circuit is rated at one half the total power supply wattage. Example: A TLV-25024-SC has two 12 volt 125 watt output circuits. Refer to Interpreting Power Supply Catalog Numbers for further explanation of catalog numbers. immer Notice Only use dimmers designed and rated for magnetic loads. Consult the dimmer manufacturer for recommendations regarding your lighting application. Interpreting Power Supply Catalog Numbers (Groups I, II, III) GROUP I GROUP II GROUP III Power Supply TLVA 100 12 S C with Breaker(s) Timer, Photocell 100 atts 12 Volt Output Shielded Line Cord (Standard) Power Supply with Breaker(s) 100 atts 24 Volt Output Shielded Optional Line Cord TLV 100 24 S C Power Supply without Breaker(s) 250 atts 24 Volt Output Shielded T 250 24 S Recommended ire Size and Voltage rop 1 12 VOLT SYSTEM ire Size (Gauge) 14 12 10 8 6 ATTS (VA) Per Circuit 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 Maximum Secondary ire Length in Feet (Meters) 75 37 25 19 15 12 11 9 8 7 7 6 6 5 5 5 4 4 4 4 (22.9) (11.3) (7.6) (5.8) (4.8) (3.7) (3.4) (2.7) (2.4) (2.1) (2.1) (1.8) (1.8) (1.5) (1.5) (1.5) (1.2) (1.2) (1.2) (1.2) 118 59 39 30 24 20 17 15 13 12 11 10 9 8 8 7 7 7 6 6 (36.0) (18.0) (11.9) (9.1) (7.3) (6.1) (5.2) (4.6) (4.0) (3.7) (3.4) (3.0) (2.7) (2.4) (2.4) (2.1) (2.1) (2.1) (1.8) (1.8) 188 94 63 47 38 31 27 24 21 19 17 16 14 13 13 12 11 10 10 9 (57.3) (28.7) (19.2) (14.5) (11.6) (9.4) (8.2) (7.3) (6.4) (5.8) (5.2) (4.9) (4.3) (4.0) (4.0) (3.7) (3.4) (3.0) (3.0) (2.7) 299 149 100 75 60 50 43 37 33 30 27 25 23 21 20 19 18 17 16 15 (91.1) (45.4) (30.5) (22.9) (18.3) (15.2) (13.1) (11.3) (10.1) (9.1) (8.2) (7.6) (7.0) (6.4) (6.1) (5.8) (5.5) (5.2) (4.9) (4.6) 476 238 159 119 95 79 68 60 53 48 43 40 37 34 32 30 28 26 25 24 (145.1) (72.5) (48.5) (36.3) (29.0) (24.1) (20.7) (18.3) (16.2) (14.6) (13.1) (12.2) (11.3) (10.4) (9.8) (9.1) (8.5) (7.9) (7.6) (7.3) 420 440 460 480 500 4 3 3 3 3 (1.2) (0.9) (0.9) (0.9) (0.9) 6 5 5 5 5 (1.8) (1.5) (1.5) (1.5) (1.5) 9 9 8 8 8 (2.7) (2.7) (2.4) (2.4) (2.4) 14 14 13 12 12 (4.3) (4.3) (4.0) (3.7) (3.7) 23 22 21 20 19 (7.0) (6.7) (6.4) (6.1) (5.8) 24 VOLT SYSTEM ire Size (Gauge) 14 12 10 8 6 ATTS (VA) Per Circuit 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 Maximum Secondary ire Length in Feet (Meters) 150 75 50 37 30 25 21 19 17 15 14 12 12 11 10 9 9 8 8 7 (49.7) (22.9) (15.2) (11.3) (9.1) (7.6) (6.4) (5.8) (5.2) (4.6) (4.3) (3.7) (3.7) (3.4) (3.0) (2.7) (2.7) (2.4) (2.4) (2.1) 237 118 79 59 47 39 34 30 26 24 22 20 18 17 16 15 14 13 12 12 (92.2) (36.0) (24.1) (18.0) (14.3) (11.9) (10.4) (9.1) (7.9) (7.3) (6.7) (6.1) (5.5) (5.2) (4.9) (4.6) (4.3) (4.0) (3.7) (3.7) 376 188 125 94 75 63 54 47 42 38 34 31 29 27 25 24 22 21 20 19 (114.6) (57.3) (38.1) (28.7) (22.9) (19.2) (16.5) (14.3) (12.8) (11.6) (10.4) (9.4) (8.8) (8.2) (7.6) (7.3) (6.7) (6.4) (6.1) (5.8) 597 299 199 149 119 100 85 75 66 60 54 50 46 43 40 37 35 33 31 30 (182.0) (91.1) (60.7) (45.4) (36.3) (30.5) (26.0) (22.9) (20.1) (18.3) (16.5) (15.2) (14.0) (13.1) (12.2) (11.3) (10.7) (10.1) (9.4) (9.1) 952 476 317 238 190 159 136 119 106 95 87 79 73 68 63 60 56 53 50 48 (290.1) (145.1) (96.7) (72.5) (57.9) (48.5) (41.5) (36.3) (32.3) (29.0) (26.5) (24.1) (22.3) (20.7) (19.2) (18.3) (17.1) (16.2) (15.2) (14.6) 1 Charts are based on SPT-3 wire and a maximum.63 voltage drop at the end of the run. Many applications allow a 2.5 voltage drop. 420 440 460 480 500 7 7 7 6 6 (2.1) (2.1) (2.1) (1.8) (1.8) 11 11 10 10 9 (3.4) (3.4) (3.0) (3.0) (2.7) 18 17 16 16 15 (5.5) (5.2) (4.9) (4.9) (4.6) 28 27 26 25 24 (8.5) (8.2) (7.9) (7.6) (7.3) 45 43 41 40 38 (13.7) (13.1) (12.5) (12.2) (11.6) 88

Low Voltage Lighting Power Supplies with 24-our Timer & Photocell Mounting Bracket with Keyhole Slots Easy-to-Read Nameplate 1.38 in. (3.5 cm.) Removable Front Cover Photocell 24 hour timer Accessory Switch Voltage Regulator Switch Screw Lug Output Terminals 6 (1.8 m) Power Cord with Grounded Plug BOTTOM VIE.88 x 1.13 in. (2.2 x 2.9 cm.) Knockout Power Cord Electrical Connection iagrams FEATURES 100, 150, 300, 600 att Models. Primary, or 12/24 V Secondary, 60 z. Fully encapsulated core and coil. 24-hour timer and photocell. all mounting brackets included. UL Listed. Screw lug terminals for ease of wiring. eadfront terminal cover for added safety. 3-Position on-off-auto switch for versatility. Removable front cover, generous wiring space. 6 power cord with grounded plug. Voltage regulation switch for 11, 12 or 13 volts. Overload protection on primary and secondary sides. 10-year limited product warranty (3-years on timer/photocell). Faraday shielded for greater safety. Units OR = SELECTION CART 12/24 V Units GROUP I INPUT INPUT APPROX. IMENSIONS 2 APPROX. ATTS OUTPUT 12/ OUTPUT 1 Inches (Cm.) SIP EIGT CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 TLVA-10012-SC TLVA-10024-SC 18.00 (45.7) 4.00 (10.2) 3.50 (8.9) 10 (4.5) 150 TLVA-15012-SC TLVA-15024-SC 18.00 (45.7) 4.00 (10.2) 3.50 (8.9) 10 (4.5) 300 TLVA-30012-SC TLVA-30024-SC 19.00 (48.3) 4.62 (11.7) 4.25 (10.8) 14 (6.4) 600 TLVA-60012-SC TLVA-60024-SC 19.00 (48.3) 4.62 (11.7) 4.25 (10.8) 18 (8.2) 1 12/ denotes a three wire circuit, one output or two outputs. Each is rated at one half the nameplate wattage. 2 imensions not suitable for construction purposes. Contact factory for certified drawings. 89

Power Supply Specifications, imensions and Selection Electrical Connection iagrams Units OR = SELECTION CARTS 12/24 V Units GROUP II IT LO VOLTAGE CIRCUIT BREAKERS 3 ITOUT LINE COR IT LINE COR 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT APPROX. ATTS 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 APPROX. IMENSIONS 5 SIP UL-506 LISTE UL-506 LISTE UL-1012 LISTE UL-1012 LISTE Inches (Cm.) EIGT CATALOG NO. CATALOG NO. CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 TLV-10012-S 1 TLV-10024-S 1 TLV-10012-SC 1 TLV-10024-SC 1 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 150 TLV-15012-S 1 TLV-15024-S 1 TLV-15012-SC 1 TLV-15024-SC 1 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 250 TLV-25012-S 1 TLV-25024-S 1 TLV-25012-SC 1 TLV-25024-SC 1 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 12 (5.4) 500 TLV-50012-S 2 TLV-50024-S 1 TLV-50012-SC 2 TLV-50024-SC 1 14.00 (35.6) 4.66 (11.8) 4.60 (11.7) 17 (7.7) 750 TLV-75012-S 2 TLV-75024-S 1 14.00 (35.6) 4.66 (11.8) 4.60 (11.7) 20 (9.1) 1000 TLV-100012-S 2 TLV-100024-S 2 15.35 (39.0) 5.41 (13.7) 5.23 (13.3) 28 (12.7) 1500 TLV-150024-S 2 15.35 (39.0) 5.41 (13.7) 5.23 (13.3) 35 (15.9) GROUP III ITOUT LO VOLTAGE CIRCUIT BREAKERS ITOUT LINE COR IT LINE COR 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT 120 VOLT INPUT APPROX. ATTS 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 12 VOLT OUTPUT 12/24 VOLT OUTPUT 4 APPROX. IMENSIONS 5 SIP UL-506 LISTE UL-506 LISTE UL-1012 LISTE UL-1012 LISTE Inches (Cm.) EIGT CATALOG NO. CATALOG NO. CATALOG NO. CATALOG NO. EIGT IT EPT Lbs. (Kg.) 100 T-10012-S T-10024-S T-10012-SC T-10024-SC 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 150 T-15012-S T-15024-S T-15012-SC T-15024-SC 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 9 (4.1) 250 T-25012-S T-25024-S T-25012-SC T-25024-SC 13.00 (33.0) 3.91 (9.9) 3.98 (10.1) 12 (5.4) 500 T-50012-S T-50024-S T-50012-SC T-50024-SC 14.00 (35.6) 4.66 (11.8) 4.60 (11.7) 17 (7.7) 750 T-75012-S T-75024-S 14.00 (35.6) 4.66 (11.8) 4.60 (11.7) 20 (9.1) 1000 T-100012-S T-100024-S 15.35 (39.0) 5.41 (13.7) 5.23 (13.3) 28 (12.7) 1500 T-150024-S 15.35 (39.0) 5.41 (13.7) 5.23 (13.3) 35 (15.9) 1 Push to reset Thermal Breaker. 2 Magnetic Breaker Toggle On/Off. 3 Low voltage circuit breakers are for protection only and are not to be used as an on/off switch for 100 and 150 watt 12 volt units or on 100, 150 and 250 watt 12/24 volt units. 4 12/24 volt output denotes a three-wire circuit, one 24 volt output or two 12 volt outputs. Each 12 volt output is rated at 1/2 nameplate wattage. 5 imensions not for construction purposes. Contact factory for certified drawings. 90

Pool and Spa Specifications imensions and Selection ELECTRICAL CONNECTION IAGRAM 100, 300 & 500 VA MAXIMUM INING RISE 115 C BLACK ITE 14V 13V 0V ENCLOSURE MUST BE GROUNE GROUP IV 120 VOLT INPUT 12, 13 OR 14 VOLT OUTPUT 1Ø, 60 z COL - ROLLE STAINLESS STEEL APPROX. IMENSIONS APPROX. KNOCKOUT PRIMARY SECONARY VA STEEL ENCLOSURE ENCLOSURE Inches (Cm.) SIP. EIGT SIZE CURRENT LS. LS. RATING CATALOG NO. 1 CATALOG NO. 1 EIGT IT EPT Lbs. (Kg.) In. (Cm.) (MAX. AMPS) 2 PCS. OF # 4 PCS. OF # 100 T-1-79101-SL T-79101-SL 8.40 (21.3) 3.50 (8.9) 4.83 (12.3) 7 (3.2) Two Single 100 T-1-79101-SR T-79101-SR 8.40 (21.3) 3.50 (8.9) 4.83 (12.3) 7 (3.2).875 (2.2) 8.3 14 CU 12 CU 300 T-1-79203-SL T-79203-SL 8.40 (21.3) 4.22 (10.7) 5.50 (14.0) 12 (5.4) Two Single 300 T-1-79203-SR T-79203-SR 8.40 (21.3) 4.22 (10.7) 5.50 (14.0) 12 (5.4).875 (2.2) 25.0 14 CU 12 CU 500 T-1-79105-SL T-79105-SL 10.00 (25.4) 4.41 (11.2) 5.66 (14.4) 15 (6.8) Two Single 500 T-1-79105-SR T-79105-SR 10.00 (25.4) 4.41 (11.2) 5.66 (14.4) 15 (6.8).875 (2.2) 41.6 14 CU 10 CU GUIE CART 2 For Selecting Secondary Voltage Tap To Be Used ith Various ire Sizes For Given istances Between Transformer And Lamps ISTANCE FT. (M.) FROM TRANSFORMER TO LAMPS FOR 100 ATT LOA IRE SIZE LESS TAN (Gauge) 30 (9.1) 30 (9.1) 60 (18.3) 90 (27.4) 120 (36.6) 150 (45.7) 180 (54.9) 210 (64.0) 240 (73.2) 270 (82.3) 300 (91.4) 14 13V 14V Use Larger ire Size 12 13V 13V 14V Use Larger ire Size 10 13V 13V 14V 14V Use Larger ire Size 8 13V 13V 13V 14V 14V 14V Use Larger ire Size ISTANCE FT. (M.) FROM TRANSFORMER TO LAMPS FOR 300 ATT LOA IRE SIZE LESS TAN (Gauge) 10 (3.0) 10 (3.0) 20 (6.1) 30 (9.1) 40 (12.2) 50 (15.2) 60 (18.3) 70 (21.3) 80 (24.4) 90 (27.4) 100 (30.5) 110 (33.5) 120 (36.6) 12 13V 13V 14V Use Larger ire Size 10 13V 13V 14V 14V Use Larger ire Size 8 13V 13V 13V 14V 14V 14V Use Larger ire Size 6 13V 13V 13V 13V 14V 14V 14V 14V 14V ISTANCE FT. (Mt.) FROM TRANSFORMER TO LAMPS FOR 500 ATT LOA IRE SIZE LESS TAN (Gauge) 10 (3.0) 10 (3.0) 20 (6.1) 30 (9.1) 40 (12.2) 50 (15.2) 60 (18.3) 70 (21.3) 80 (24.4) 90 (27.4) 100 (30.5) 110 (33.5) 120 (36.6) 10 13V 14V 14V Use Larger ire Size 8 13V 13V 14V Use Larger ire Size 6 13V 13V 13V 14V 14V 14V Use Larger ire Size 4 13V 13V 13V 13V 14V 14V 14V 14V 14V 1 Suffix SL denotes primary cable entry from left side, low voltage right side. Suffix SR denotes primary cable entry from right side, low voltage left side. All units have auto-thermal reset. 2 Confirm tap selection by measurement of voltage at lamp terminals when all of the lamps are operating. 91

Low Voltage General Purpose Transformers FEATURES UL Listed, CSA Certified. 100, 150, 300, 600, 750, 1000 VA. 1 Phase, 60 z, 120 or 240 volt input. 12 or 24 volt output. Input Auto-Thermal reset switch. Output circuit breaker. Fully encapsulated core and coil. Full fault current carrying Faraday Shield. Flexible copper leadwire terminations. UL class 180 C insulation system 115 C rise. UL Type 2 enclosure. Keyhole slotted wall mounting brackets. Black finish. Bottom access. Two 0.875 (2.2 cm) single knockouts each side. Two dual 0.875 (2.2 cm) and 1.125 (2.9 cm)knockouts on bottom cover. GROUP V 120 PRIMARY VOLTS 12 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T-1-79600-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 15 AMP Push To Reset Thermal Breaker 150 T-1-79620-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 20 AMP Push To Reset Thermal Breaker 300 T-1-79621-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 40 AMP Push To Reset Thermal Breaker 600 T-1-79622-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 60 AMP Magnetic Toggle On/Off Breaker 750 T-1-79603-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 75 AMP Magnetic Toggle On/Off Breaker 1000 T-1-79604-S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 100 AMP Magnetic Toggle On/Off Breaker 120 PRIMARY VOLTS 24 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T-1-79605-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T-1-79623-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T-1-79624-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 600 T-1-79625-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 40 AMP Push To Reset Thermal Breaker 750 T-1-79608-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T-1-79609-S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 240 PRIMARY VOLTS 12 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T-1-79610-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 15 AMP Push To Reset Thermal Breaker 150 T-1-79626-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 20 AMP Push To Reset Thermal Breaker 300 T-1-79627-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 40 AMP Push To Reset Thermal Breaker 600 T-1-79628-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 60 AMP Magnetic Toggle On/Off Breaker 750 T-1-79613-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 75 AMP Magnetic Toggle On/Off Breaker 1000 T-1-79614-S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 100 AMP Magnetic Toggle On/Off Breaker 240 PRIMARY VOLTS 24 SECONARY VOLTS, TO ININGS, 1Ø, 60 z APPROX. IMENSIONS APPROX. VA CATALOG NO. Inches (Cm.) SIP EIGT CB RATING CB STYLE EIGT IT EPT Lbs. (Kg.) 100 T-1-79615-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T-1-79629-S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T-1-79630-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 600 T-1-79631-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 15 (6.8) 40 AMP Push To Reset Thermal Breaker 750 T-1-79618-S 11.68 (29.7) 4.66 (11.8) 4.57 (11.6) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T-1-79619-S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 26 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 92

Buck- Boost Transformers The No-Frills Low Voltage Lighting Alternative Buck-Boost Transformers offer a no-frills approach to low voltage lighting. (See Chart Below) A typical Buck-Boost application is 120 volts in and 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage isolation transformer is field connected as an autotransformer. For more information on Buck-Boost Transformers, refer to the next section in this catalog. GROUP VI 120 x 240 VOLT INPUT 12/24 VOLT OUTPUT 1Ø, 60 z INSULATING SECONARY MAXIMUM APPROX. IMENSIONS APPROX. CATALOG TRANSFORMER Current Output Inches (Cm.) NET EIGT NUMBER RATING EIGT IT EPT Lbs. (Kg.) T-1-81047 0.05 KVA 4.16 2.08 6.38 (16.2) 3.19 (8.1) 3.00 (7.6) 4 (1.8) T-1-81048 0.10 KVA 8.32 4.16 6.62 (16.8) 3.75 (9.5) 3.62 (9.2) 5 (2.3) T-1-81049 0.15 KVA 12.52 6.25 7.12 (18.1) 3.75 (9.5) 3.62 (9.2) 7 (3.2) T-1-81050 0.25 KVA 20.80 10.40 8.68 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) T-1-81051 0.50 KVA 41.60 20.80 9.06 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) T-1-81052 0.75 KVA 62.50 31.25 9.68 (24.6) 4.75 (12.1) 4.51 (11.5) 19 (8.6) T-1-11683 1.00 KVA 83.20 41.60 10.50 (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) T-1-11684 1.50 KVA 125.00 62.50 11.62 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) T-1-11685 2.00 KVA 166.00 83.20 13.00 (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) T-1-11686 3.00 KVA 250.00 125.00 11.50 (29.2) 10.31 (26.2) 7.13 (18.1) 55 (24.9) T-1-11687 5.00 KVA 416.00 208.00 14.38 (36.5) 10.31 (26.2) 7.13 (18.1) 75 (34.0) T-2-11688 7.50 KVA 625.00 312.50 21.19 (53.8) 13.50 (34.3) 10.84 (27.5) 125 (56.7) T-2-11689 10.00 KVA 833.00 416.60 21.19 (53.8) 13.50 (34.3) 10.84 (27.5) 160 (72.6) Electrical Connection iagrams GROUP V GROUP VI 240V INPUT 4 3 INPUT 4 3 OUTPUT X4 OUTPUT X4 240V 240V INPUT 4 3 240V INPUT 4 3 OUTPUT X4 OUTPUT X4 93

VOLTAGE ROP CART Voltage Life Expectancy % of Rated at Lamp of Lamp Candlepower 13.2 2/3 Rated Life 350 12.6 3/4 Rated Life 180 12.0 As Rated 100 11.5 2X Rated Life 80 11.0 3X Rated Life 74 10.5 5X Rated Life 65 10.0 9X Rated Life 50 CABLE SIZE CONSTANT CART Cable Cable Size Size Constant #18 1380 #16 2200 #14 3500 #12 7500 #10 11,920 #8 18,960 #6 30,150 VOLTAGE ROP FORMULA Total atts on Cable X Length of Run Cable Size Constant = Voltage rop 50' (15.2 m) A typical installation showing three separate runs on a 300 Power Supply 80' (24.4 m) 100' (30.5 m) 12/2 ire Low Voltage Lighting Layout Grid 300 POER SUPPLY 12/2 ire 94