INSTALLATION INSTRUCTIONS MODEL Z Z Z Z 1.5 HP 115/230V Z Z 2.0 HP 115/230V Z Z

Similar documents
INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

MODEL SS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Material required for drilled well application (indoor use only)

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

MODEL H INSTALLATION INSTRUCTIONS

MODEL P INSTALLATION INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

HALLMARK INDUSTRIES INC

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

PRESSURE BOOSTER 150

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

LAWN SPRINKLER, IRRIGATION PUMP

PRE-PLUMBED SEWAGE SYSTEM

2 Wire Plus Ground 3 Wire Plus Ground IL0655

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Owners Manual: - Pumps

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

HALLMARK INDUSTRIES INC. Deep Well Submersible Pumps Operating & Installation Instructions

ESE Series Cast Iron Sewage Pumps

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

8000 / 10,000 / 12,000

INSTALLATION AND SERVICE MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

Installation & Operating Manual

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Installation Operation Parts

SUNC3000 / Item #40885

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

SHALLOW WELL JET PUMP

Cascade Owners Manual

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

STAR STOP SHALLOW WELL JET PUMP

Aermotor 4 SUBMERSIBLE PUMPS 35, 50, 75, 90 GPM A+ SUPER SUB Series stainless steel

Installation Instructions

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

SS/SSH Submersible Pump. Owner s Manual

INSTALLATION AND SERVICE MANUAL

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Owner s Manual Drill and Light Weight Portable Utility Pumps

OWNER S MANUAL CONVERTIBLE JET PUMP

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

GARDEN HOSE UTILITY PUMP

Electric Fuel Pump FPM

SUBMERSIBLE SUMP PUMPS

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

Installation & Operating Manual

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

WELDING FUME EXHAUSTERS & ARMS

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

SUPER PUMP OUT SYSTEM

Model &

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

SELF PRIMING CHEMICAL SERVICE PUMPS

SUBMERSIBLE SUMP PUMPS

SuperFlo 9,000 High Volume Pump Product Manual

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Commander Pro 100 SUBMERSIBLE SYSTEM Installation, Operation and Trouble-Shooting Manual

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

Installation & Operating Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

65 Series. Valve Operation Manual

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

June14. Type

GeyserMax-Flow Series

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

Installation Instructions and Parts Manual CPJ SERIES JET PUMPS. Shallow Well Jet Pumps. Convertible Jet Pumps. Ejectors (Purchase separately)

Installation Instructions

2-Speed Pumps Item #s 7813, 7814, 7818 & 7819

Powerful & Intelligent Submersible Pumps

Grind Pro Series. Operator Manual. Manufacture by:

OWNERS MANUAL ECODIVER

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

End Suction Centrifugal

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

BENECOR DEF CENTRIFUGAL PUMP

Installation Instructions & Warranty

Installation Instructions

Sealless Centrifugal Canned Motor Pumps

Transcription:

INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. BRASS IMPELLER For 700516Z and 700518Z MODEL 700506Z 700508Z 700516Z 700518Z SPRINKLER PUMP Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. 1.5 HP 115/230V 700506Z 700516Z 2.0 HP 115/230V 700508Z 700518Z 2017 BURCAM Printed in Canada 710950

SAFETY INSTRUCTIONS : This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C D Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes have been designed with your safety in mind. Be sure you comply with them. A separate circuit have to be lead from the home electrical distribution panel properly protected with a fuse or a circuit breaker. We also recommend that a ground fault circuit be used. Consult a licensed electrician for all wiring. The ground terminal on the three prong plugs should never be removed. They are supplied and designed for your protection. Never make adjustments to any electrical appliance or product with the power connected. Do not only unscrew the fuse or trip the breaker, remove the power plug from the receptacle. Material required for drilled well application Pump installation Pump installation Suction line Desired length of polyethylene 2 pipe CSA or UL approved, to link up from pumping level to pump. 1 2 foot valve (750756). 2 2 male adaptors. 4 2 stainless steel clamps. Teflon tape. Discharge line Desired length of polyethylene 1 1/2 pipe, 100PSI, CSA or UL approved. 1 1/2 male adaptor. Teflon tape. Desired quantity of sprinkler for irrigation. Tools 2 Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench adjustable wrench to tighten fittings, propane torch and welding material. FOR INFORMATION TEL : 514.337.4415 FAX : 514.337.4029

APPLICATION : This pump is designed to be used with automatic sprinkler systems. Ideal for lakes, ponds, for residential, farm and cottage use. Capacity : Suction 700516Z 700516Z 700518Z 700518Z Friction loss in pipe not included. 1.5 HP 2.0 HP 5 3900 4200 US GPH 10 3600 3900 US GPH 15 3300 3600 US GPH 20 3000 3300 US GPH FEATURES : Easy to prime large pump body. Thermally protected motor, stainless steel shaft, bearing to bearing. Capacity up to 25 sprinklers, 70 GPM US maximum flow, 100 maximum head. 1.5 HP 115V/230V AC, 60Hz, 15.2 A/7.6 A (30 A/15 A at start up). 2.0 HP 115V/230V AC, 60Hz, 15.6 A/7.8 A (31 A/15.5 A at start up). INSTALLATION STEPS STEP 1 see typical installation diagram in page 6 We recommend that you install your pump in a clean and dry location where there is adequate room for servicing at a later date. Protection from freezing temparatures and good ventilation should be considered as well, to provide the pump an environment for long life. Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe. Friction lossees in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet.the suction pipes should be increased from 2 to 2 1/4. This will reduce friction losses and allow the pump to give maximum performance. Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water before turning on the power. THE RUN OF THE HORIZONTAL PIPE FROM THE TOP OF YOUR WELL TO THE PUMP MUST BE INSTALLED IN A TRENCH, BELOW THE FROST LEVEL OF YOUR AREA, FOR A YEAR ROUND APPLICATION. STEP 2 Cut the desired lenght of poly pipe to run from the top of the well to the pumping level. Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside of pipe. This may block the pump injector or impeller). Tale male adaptor threads with teflon tape and thread adaptor into the foot valve. Slide 2 stainless steel clamps over one end of pipe and use torch to soften pipe. Insert the male adaptor and foot valve into this pipe end. Tighten clamps with screwdriver when cool. For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor. 3 FOR INFORMATION TEL : 514.337.4415 FAX : 514.337.4029 3

STEP 3 Insert the well seal elbow thru the opening of the seal. Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipe with your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal). Tighten clamps with screwdriver when cool. STEP 4 Install the well seal and piping assembly into your well casing. Tight down the well seal bolts using your adjustable wrench. To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap instead of an elbow and a well seal as described in steps 3 and 4. STEP 5 Install your pump on a sound foundation, as close as possible to the water. Locate the suction inlet in the front of the pump body. Thread an adaptor into inlet using teflon tape. Do not over tighten. STEP 6 Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way, with stainless steel clamps and torch. Do not fill in your trench until you have checked for any leaks in your connections or trouble in your water system. STEP 7 For sand or well point Sand or well points are limited to areas where water bearing sand or gravel lies below the surface, and where there are no boulders or rocks to interfere with the driving into the ground of the point. The amount of water any one well point will supply is usally rather limited. Sometimes, it is necessary to use more than one point to increase the supply of water entering to the pump s suction. THE IMPORTANT INSTALLATION STEP IN USING WELL POINTS IS THAT A CHECK VALVE MUST BE USED IN THE SUCTION PIPE LEADING TO THE SUCTION INLET, AS CLOSE TO THE PUMP AS POSSIBLE, TO KEEP LINE AND PUMP WELL PRIMED. 4 FOR INFORMATION TEL : 514.337.4415 FAX : 514.337.4029 3

TYPICAL PUMPING INSTALLATION DIAGRAM FOR INFORMATION TEL : 514.337.4415 FAX : 514.337.4029 5

STEP 7 STEP 5 STEP 6 2 foot valve (750759) 2 pipe on suction line 1 1/2 pipe on discharge line 1 pipe on sprinkler line FOR FOR INFORMATION INFORMATION TEL: : 514.337.4415 FAX FAX: : 514.337.4029 514.337.4029

REPAIR PARTS REF. PART DESCRIPTION REF. PART DESCRIPTION 1 710936 Drain plug with O ring 2 710937 Pump body with bolts 3 710938 Plug with O ring 4 710939 Pump body O ring 5 710940 Diffuser O ring 6 710941 Diffuser with bolts 7 710942 Noryl impeller 7 710942B Brass impeller 8 750943 Mechanical seal 9 710944 Seal plate 10 710945 Motor & bolts (700506Z - 700516Z 1.5 HP) 10 710951 Motor & bolts (700508Z - 700518Z 2.0 HP) 11 710946 Connection box base 12 710947 Connection box cover 13 710948 Capacitor Repair parts may be ordered your authorized point of sale of from BURCAM PUMPS 7

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Defective motor Turn switch to on position Replace Reset Replace Motor runs but no water is delivered. Pump not primed Leaky suction line Foot valve plugged Water level below foot valve Suction lift to great Improper voltage Prime with clean water Check pipe and pipe connections Clean Check foot valve level Water level lower than lift capacity Check voltage Pump does not deliver to full capacity. Air spurts from fawcets. Water level below foot valve Excessive friction in pipe Improper voltage Leaky suction line Gaz in water Check foot valve level Too small or dirty pipe Check voltage Check pipe and pipe connections Check and consult factory 8 TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation. FOR INFORMATION TEL : 514.337.4415 6 FAX : 514.337.4029