CHAPTER 4 PROTECTION REQUIREMENTS

Similar documents
The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

2006 IEEE PES General Meeting June 2006, Montreal, Canada Paper 06GM0613. Fault Current Limiters - Report on the Activities of Cigre WG A3.

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Breaker-failure protection RAICA

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

Industry Automation Control Components

7. SERVICES OVER 600 VOLTS

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Application of Sepam Relays for Arc Flash Hazard Reduction at Low Voltage Switchgear

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

A. Submit manufacturer's literature and technical data before starting work.

Company Directive STANDARD TECHNIQUE : TP4B/2. Relating to 11kV and 6.6kV Transformer Protection

Guideline for Parallel Grid Exit Point Connection 28/10/2010

Dual Power. Protection. Protection

TECHNICAL SPECIFICATIONS OF PCC PANEL

Guidelines for connection of generators:

Shippensburg University

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Final Draft Report. Assessment Summary. Hydro One Networks Inc. Longlac TS: Refurbish 115/44 kv, 25/33/ General Description

Switchgear and Distribution Systems for Engineers and Technicians

B4 Load Break Switches

RAPTOR DEFAULT TEST TEMPLATES

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

CHAPTER 6 GUIDELINES ON DESIGN OF ELECTRICAL INSTALLATION

EE 741 Over-voltage and Overcurrent. Spring 2014

Question Set(2017) Switch Gear & protection(5 th SEm) 9. Explain the construction and operating principle with proper diagram:

Standards, Procedures and Policies for Grid Connection

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

PSW102 type CT powered protection unit

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

33kV Connection up to 90MVA

32-SDMS-02 SPECIFICATIONS FOR

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

Power systems Protection course

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Electromagnetic Industries LLP

Protection Equipment

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

LARSEN & TOUBRO LIMITED TYPICAL SCHEME FOR PROTECTION OF SYNCHRONOUS MOTORS

Marina Bay Sands Guidelines for Electrical and Wiring Service

Interconnection Feasibility Study Report GIP-226-FEAS-R3

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

PART C: GUARANTEED TECHNICAL PARTICULARS OF 33 KV, 2x5/6.67 MVA RURAL TYPE SUB-STATION MATERIALS

Proposed New ISO Rules Section Version 2.0 Generating Unit Technical Requirements ( New ISO Rules Section Version 2.

KD LV Motor Protection Relay

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Protection and control VIP30, VIP35. Relays technical manual

Protective Device Coordination ETAP Star

RESIDUAL CURRENT CIRCUIT BREAKER

Unrestricted. Air Core Reactor Applications Current Limiting Reactors

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

NPS/001/017 Technical Specification for Low Voltage and High Voltage Current Limiting Fuse Links

Thermal Overcurrent Circuit Breaker 3120-F...

Breaker failure relay REB 010

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX TRANSMISSION/GENERATION FEASIBILITY STUDY SHORT CIRCUIT ANALYSIS

3.2. Current Limiting Fuses. Contents

ANALYSIS OF OVERCURRENT PROTECTION RELAY SETTINGS OF A COMMERCIAL BUILDING NURUL SYAQIRAH BINTI MOHD SUFI UNIVERSITI MALAYSIA PAHANG

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Source-Side Fuse/Load-Side Recloser Coordination

Tolerance-Based Time-Current Coordination

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

4. CIRCUIT BREAKERS (Continued)

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

CP Automatic capacitor bank

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Thermal Overcurrent Circuit Breaker 3120-F...

Selective Coordination Enforcement:

APPENDIX C FACILITY ILLUSTRATION

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD. ( A

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

VD4/R. MV vacuum circuit-breakers for secondary distribution

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

Transcription:

CHAPTER 4 PROTECTION REQUIREMENTS

CHAPTER 4 PROTECTION REQUIREMENTS 4.1 General Means of protection for automatic disconnection against phase and earth faults shall be provided on the customer main switch. The type and settings of protective devices shall be so selected that they can grade properly with HK Electric infeed protection. The customer shall provide Time-Current curve showing that the proposed protection scheme for the main switch can grade properly with HK Electric system under both phase fault and earth fault conditions. 4.2 Customer HV Main Switch 1. Anticipated maximum 11-kV fault level:- Phase fault: Earth fault: 18.4 ka (350 MVA) ka To grade with HK Electric 11-kV feeder protection, the protective relays of customer 11-kV main switch shall have an operating time not exceeding the maximum allowable time-current curves for phase fault and earth fault as shown in Drg. Nos. GCS/4/01 and 02 respectively. 2. Anticipated maximum 22-kV fault level:- Phase fault: Earth fault: 25 ka (952 MVA) 2.5 ka To grade with HK Electric 22-kV feeder protection, the protective relays of customer 22-kV main switch shall have an operating time not exceeding the maximum allowable time-current curves for phase fault and earth fault as shown in Drg. Nos. GCS/4/03 and 04 respectively. 3. Protection C.T.s shall have adequate output to prevent C.T. saturation. The customer shall provide document/calculation sheet to show that the proposed C.T.s have adequate output for the application under both phase and earth fault conditions. 4.1

4.3 Customer LV Main Switch 1. The anticipated maximum LV (380 V) fault level is 40 ka (26 MVA). The overcurrent protection of customer LV main switch shall grade with HK Electric's transformer overcurrent protection and has an operating time not exceeding the maximum allowable time-current curves for various ratings of LV main switches as shown in Drg. No. GCS/4/05. 2. The customer protective devices shall be set so that disconnection is achieved within 5 seconds during an earth fault. 3. Bonding Between HK Electric and Customer's Earthing Systems a. Under the current regulations, the customer's earthing system shall be bonded to that of the HK Electric s earthing system for transformer supplies. This will cause a significant increase in LV earth fault current, the magnitude of which can be as high as phase fault current. b. If the customer LV overcurrent and earth fault protections share the same set of C.T.s, high output C.T.s and low burden type earth fault relay shall be used to prevent C.T. saturation. The customer shall provide document/calculation sheet to show that the proposed protection C.T.s have adequate output for the application under earth fault condition. c. As an alternative to the use of high output C.T.s and low burden type earth fault relay, separate sets of C.T.s can be used for overcurrent and earth fault protections as shown in Drg. No. GCS/4/06. 4.4 Protection Scheme For Main Switch The customer is advised to provide a summary sheet as shown in Drg. No. GCS/4/07 and GCS/4/08 for LV and HV main switch protection scheme respectively to HK Electric for consideration. 4.5 Auxiliary Supply for Protection Scheme and Relay If the customer protection scheme or relay requires an auxiliary supply, the auxiliary supply shall be reliable and not be interrupted during LV or HV faults on the customer equipment to ensure that the customer protection scheme and relay perform the protection function properly. 4.2

4.6 Schedule of Drawings - Protection Requirements Drawing No. Drawing Title GCS/4/01 Maximum Allowable Time-Current Curve of Overcurrent Protection at Customer 11-kV Main Switch GCS/4/02 Maximum Allowable Time-Current Curve of Earth Fault Protection at Customer 11-kV Main Switch GCS/4/03 Maximum Allowable Time-Current Curve of Overcurrent Protection at Customer 22-kV Main Switch GCS/4/04 GCS/4/05 GCS/4/06 GCS/4/07 GCS/4/08 Maximum Allowable Time-Current Curve of Earth Fault Protection at Customer 22-kV Main Switch Maximum Allowable Time-Current Curves of Overcurrent Protection at Customer LV Main Switch Recommended C.T. Arrangement for Customer's Protective Device at LV Main Switch LV Main Switch Protection Scheme Summary Sheet HV Main Switch Protection Scheme Summary Sheet 4.3

100000 80000 60000 40000 20000 10000 8000 6000 4000 2000 1000 800 600 400 200 100 4.4 Drg. No. GCS/4/01 MAXIMUM ALLOWABLE TIME-CURRENT CURVE OF OVERCURRENT PROTECTION AT CUSTOMER 11-kV MAIN SWITCH

10000 8000 6000 4000 2000 1000 800 600 400 200 100 80 60 40 20 10 4.5 Drg. No. GCS/4/02 MAXIMUM ALLOWABLE TIME-CURRENT CURVE OF EARTH FAULT PROTECTION AT CUSTOMER 11-kV MAIN SWITCH

4.6 100 200 400 600 800 1000 2000 4000 6000 8000 10000 20000 40000 60000 80000 100000 Drg. No. GCS/4/03 MAXIMUM ALLOWABLE TIME-CURRENT CURVE OF OVERCURRENT PROTECTION AT CUSTOMER 22-kV MAIN SWITCH

4.7 10 20 40 60 80 100 200 400 600 800 1000 2000 4000 6000 8000 10000 Drg. No. GCS/4/04 MAXIMUM ALLOWABLE TIME-CURRENT CURVE OF EARTH FAULT PROTECTION AT CUSTOMER 22-kV MAIN SWITCH

100000 80000 60000 40000 20000 10000 8000 6000 4000 2000 1000 4.8 0 0 0 0 0 0.09 0.08 0.07 0.06 0.05 0.04 0 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.03 0.02 0.02 0.01 0.01 Drg. No. GCS/4/05 MAXIMUM ALLOWABLE TIME-CURRENT CURVES OF OVERCURRENT PROTECTION AT CUSTOMER LV MAIN SWITCH

4.9 Drg. No. GCS/4/06 RECOMMENDED C.T. ARRANGEMENT FOR CUSTOMER'S PROTECTIVE DEVICE AT LV MAIN SWITCH

1. Circuit Breaker Information : (Main Switch No. : ) Main Switch Rating Any Built-in Protective Device? Instantaneous Trip Current Setting (ka) and Max. Setting Error Yes No Setting Details 2. Current Transformer : Function Make Model Number Ratio VA and Class Any C.T. Magnetisation Curve Provided to HK Electric? Overcurrent Yes Protection C.T. No, to be submitted later Earth Fault Yes Protection C.T. No, to be submitted later Will the overcurrent protection and earth fault protection share the same set of C.T.s? Yes No C.T. Resistance (ohm) Connection Lead Resistance (ohm) 3. Relay Information : Function Make Model Number Overcurrent Relay Earth Fault Relay Rated Current (A) Burden at Rated Current (VA) Auxiliary Supply # (A.C., D.C. or N.A.) * Characteristics e.g. EI, VI, NI (1.3 s), NI (3 s) Plug Setting Range Plug Setting Time Multiplier Setting Relay Impedance at Plug Setting (ohm) (* : EI = Extremely Inverse, VI = Very Inverse, NI= Normal Inverse) # If the customer protection scheme or relay requires an auxiliary supply, the auxiliary supply shall be reliable and not be interrupted during LV or HV faults on the customer equipment to ensure that the customer protection scheme and relay perform the protection function properly. 4. Maximum Earth Fault Loop Impedance, if available at the time of submission : ohm Notes : Following information shall be provided : 1. Catalogues for main switch (with details of built-in protective device, if any), C.T.s (including C.T. magnetisation curve) and relays. 2. A.C. connection diagram of overcurrent and earth fault protection for the main switch. 3. Calculation sheet showing that the proposed C.T.s have adequate output for the application under both phase and earth fault conditions. 4. Time-current characteristic curve of overcurrent protection at the proposed settings plotted at the Drg. No. GCS/4/05. Drg. No. GCS/4/07 LV MAIN SWITCH PROTECTION SCHEME SUMMARY SHEET 4.10

1. Circuit Breaker Information : (Main Switch No. : ) Main Switch Rating Any Built-in Protective Device? Instantaneous Trip Current Setting (ka) and Max. Setting Error Yes No Setting Details 2. Current Transformer : Function Make Model Number Ratio VA and Class Any C.T. Magnetisation Curve Provided to HK Electric? Overcurrent Yes Protection C.T. No, to be submitted later Earth Fault Yes Protection C.T. No, to be submitted later Will the overcurrent protection and earth fault protection share the same set of C.T.s? Yes No C.T. Resistance (ohm) Connection Lead Resistance (ohm) 3. Relay Information : Function Make Model Number Overcurrent Relay Earth Fault Relay Rated Current (A) Burden at Rated Current (VA) Auxiliary Supply # (A.C., D.C. or N.A.) * Characteristics e.g. EI, VI, NI (1.3 s), NI (3 s) Plug Setting Range Plug Setting Time Multiplier Setting Relay Impedance at Plug Setting (ohm) (* : EI = Extremely Inverse, VI = Very Inverse, NI= Normal Inverse) # If the customer protection scheme or relay requires an auxiliary supply, the auxiliary supply shall be reliable and not be interrupted during LV or HV faults on the customer equipment to ensure that the customer protection scheme and relay perform the protection function properly. Notes : Following information shall be provided : 1. Catalogues for main switch (with details of built-in protective device, if any), C.T.s (including C.T. magnetisation curve) and relays. 2. A.C. connection diagram of overcurrent and earth fault protection for the main switch. 3. Calculation sheet showing that the proposed C.T.s have adequate output for the application under both phase and earth fault conditions. 4. Time-current characteristic curves of overcurrent protection and earth fault protection at the proposed settings plotted at the Drg. No. GCS/4/01 & GCS/4/02 (for 11-kV main switch) or Drg. No. GCS/4/03 & GCS/4/04 (for 22-kV main switch) respectively. Drg. No. GCS/4/08 HV MAIN SWITCH PROTECTION SCHEME SUMMARY SHEET 4.11