Complete HVAC Capability

Similar documents
SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

Nomenclature. Contents. Air Handling Unit SR AH 250 LP HS

VAHU Vertical Air Handling Unit

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Installation, Start-Up and Service Instructions

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Climas y Proyectos Leyco, S.A. de C.V.

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

Product Data. 39T Central Station Air-Handling Units. Features/Benefits. Nominal 3,500 to 46,000 Cfm

39L Series. Central Station Air Handlers. Nominal: 2,000-17,750 CFM. World's No.1 Air Conditioning Expert

SPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

BAC, BAF, BAH Central Station Air Handlers

BAC / BHC SERIES 6 to 20 Ton Air Handlers

SARAVEL MINI AIR-HANDLING UNIT

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

BAC / BHC Product Specifications

SECTION AXIAL HVAC FANS


R-22, 13 SEER 60 Hertz

FS Fan-Coil Units Hi-Rise, Vertical

TYPICAL SPECIFICATION: Critical Process Roof Top Unit 7/14/15

UNIVERSITY OF NORTH FLORIDA Arena HVAC Replacement SECTION MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS

Product Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MQL TABLE OF CONTENTS

MAH. Modular Air Handling Unit

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Product Data. Features/Benefits. 39NX Central Station Air-Handling Units. Nominal 2,000 to 55,000 Cfm

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

GUIDE SPECIFICATIONS. ES Series R-410A

Horizontal Fan Coils 200-1,200 CFM

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

BAC / BHC SERIES 6 to 20 Ton Air Handlers

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

A. Manufacturer: Provide products complying with these specifications and produced by the following:

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Product Data. 40RUA/40RUS 6to30TonDirectExpansion 7.5to30TonChilledWater Packaged Air- Handling Units FEATURES/BENEFITS

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

FN Fan-Coil Units High-Performance, Horizontal

Product Data. 40RUA / 40RUS 6to30TonDirectExpansionwithPuron R Refrigerant 7.5to30TonChilledWater Packaged Air---Handling Units 60 Hz

University of Delaware

McQuay Central Station Air Handler Medium Pressure MSL

CLIMATAIR CENTRAL STATION AIR HANDLING UNIT

Low Profile Unit Cooler

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

TSS Single-Duct VAV Terminals

Air Handling Unit Fan Selection Guide

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

Modular Variable Speed Air Handlers

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

Twin City Fan & Blower

Submittal. Front View Side View

Nomenclature. Nomenclature Distributing coil types

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SECTION CENTRIFUGAL HVAC FANS

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SDL Single-Duct, Low-Height, VAV Terminals

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Concealed Ducted Split Series R22

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Product Data. 40RUQ SplitSystemHeatPump Indoor Unit (Air---Handling Unit) With Puron R Refrigerant 60 Hz FEATURES/BENEFITS

BLOWER COILS BLOWER COILS. Providing You With Air Distribution Solutions F2-1 KRUEGER 2014 FORM - BC.HV /05/14

DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

MEDIUM PROFILE UNIT COOLERS Technical Guide

Transcription:

Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option Internal Vibration Isolation Option 8101 E. Kaiser Blvd., Suite 110 Anaheim, CA 92808 Tel (714) 529-1935 Fax (714) 529-7203

Vertical Configuration External Vibration Isolation Horizontal Configuration Internal Vibration Isolation Internal Configuration Construction Detail 2

NOMENCLATURE L H S - 21 F FAN PRESSURE CLASS L = Low M = Medium UNIT ARRANGEMENT H = Horizontal V = Vertical B = Blow-Thru 1 1 Blow-Thru units are always horizontal arrangement 2 All Vertical and all Blow-Thru units must use Long coil section FAN TYPE F = Forward Curved A = Airfoil NOMINAL FACE AREA Sq. Ft. - Large Coil COIL SECTION S = Standard L = Long 2 H = Heating Only N = None GENERAL DESCRIPTION The Central Station Air Handler is an industrial grade product with heavy gauge mill-galvanized steel framing and sheet metal throughout. Designed specifically for the HVAC industry with a full range of options and accessories, these units are also ideal for custom or design-and-build projects in refrigeration or air conditioning. Units are a single blower, internally mounted motor design. Each blower section has hinged access panels on both sides for service convenience. Air conditioning units are available for both low and medium pressure applications. The standard configurations available in most models include forward curved and airfoil wheels, with or without inlet vanes; horizontal and vertical draw-thru and horizontal blow-thru; internal or external fan isolation. Continuous diameter solid steel blower shafting is used throughout the line, resulting in large bearing diameters and low bearing loads. The highest quality grease lubricated bearings are selected to assure 200,000 hours average service life. Each rotating assembly, including fan wheel, shaft, sheaves, belts and motor, is balanced after final assembly to assure smooth, quiet performance. Standard coil options include chilled water or direct expansion cooling coils; hot water, steam and heat reclaim heating coils plus electric heat sections to provide complete comfort and environmental conditioning. * Cooling Capacity 4 row 8 FPI Coil @ 500 FPM Air Velocity: Heating Capacity 1 Row 8 FPI Coil @ 500 FPM Air Velocity: A (Water) 80 DB/67 WB Ent. Air, 2.4 GPM/Ton, 45 Ent. Water B (Dir Exp) 80 DB/67 WB Ent. Air, 45 Refrigerant Temperature C (Dir Exp) 75 DB/62.5 WB Ent. Air, 40 Refrigerant Temperature Steam 60 DB Entering Air, 5 PSIG Steam Width is left-to-right dimension facing blower discharge. Length includes fan & standard coil section (Horizontal Arrangement) 3

STANDARD CONSTRUCTION AND FEATURES Nut & Bolt Construction (except filter racks riveted inside of filter section) Heavy Gauge Mill-Galvanized Steel Sheet Metal & Framing Single Blower-Wheel Design Solid Steel Fan Shafts; Continuous Diameter, Turned, Ground & Polished Pillow-Block Bearings; 200,000 Average Service Life Lube Lines for blower Bearings Extended to Outside Internally Mounted Motor Adjustable Motor Base Blower & Drive Components Dynamically Balanced after Fabrication Hinged Access Doors w/easy Lift-Off Feature Double Drain Pan (insulated between pan and outer casing) 4

STANDARD CONSTRUCTION COIL CONSTRUCTION AND OPTIONS OPTIONAL FEATURES Copper Tubing Staggered Tube Pattern Die-formed Plate Type Aluminum Fins Mill-galvzanized Steel Casing 16 gauge Heavy Wall Copper Headers Connections: Water & Steam Coils: Steel MPT Direct Expansion: Distributor inlet Sweat Copper Suction Condenser & Reclaim: Sweat Copper Leak Tested Under Water @ 400 PSIG Dry Nitrogen 5 3/8, 1/2 & 5/8 Tubing (except steam is (5/8 O.D. only).025,.035 and.049 Wall Copper Tubes (5/8 O.D. only) 4 Thru 14 Fins Per Inch Copper Fins, Polyester Coated Fins.010 thick Aluminum Fins Phenolic Coated Coil Dipped After Fabrication Type 304 Stainless Steel Casing Copper MPT Connections in lieu of Steel Additional circuits: Face Split Row Split Intertwined

MECHANICAL SPECIFICATIONS GENERAL Each unit shall be furnished with components as specified. All units and accessories shall be constructed of heavy gauge galvanized steel as specified in the Physical Data table on the back cover on this brochure. Air handling units of type and size shall be in accordance with the Air conditioning and Refrigeration Institute (ARI) Standard 430. FAN SECTION Fan section shall have an access door on each side secured by quick-release latches. Hinges shall be of the slip joint type allowing easy removal of doors. All doors shall be generously gasketed. Fan sections used in cooling application shall be internally insulated with standard 1'' inch thick, 2.2 lb. (optional 1 inch 3 lb. foil-faced) bonded mat fiberglass insulation, affixed with a waterproof adhesive. All insulation shall comply with the requirements of NFPA 90. Fan sections for heating and ventilating units are not insulated except as specified option. COIL SECTION Heating and cooling - Cooling coil sections shall be internally insulated with standard 1'' inch thick, 2.2 lb. (optional 1 inch 3 lb. foil-faced) bonded mat fiberglass insulation, affixed with a waterproof adhesive. Insulation shall comply with the requirements of NFPA 90. Heating and ventilating coil sections are not insulated. Horizontal unit arrangements shall be available with standard and long coil sections. Vertical unit arrangements shall be available with a long coil section only. Coil sections with coils higher than 42-inch finned height shall have an intermediate drain pan (between top and bottom coils) with plastic drain tubes extending into main drain pan. Heating coils shall be considered standard in either the preheat or reheat position. Cooling coils shall be mounted on entering air side of coil section to prevent water carryover into the fan section. Standard and long coil sections shall have a removable panel on each side to allow easy coil access and removal. Optional hinged and latched access door available on return-bend side of coil section. Standard and long coil sections shall have a double drain pan with insulation between the inner and outer pan. The drain pan shall have welded corners and a 1-1/4 inch MPT drain connection on each side for positive draining. Optional stainless steel drain pans for corrosive applications. fan section. Heating only coils with more than two rows shall be bolted directly to the fan section without a casing. No insulation can be applied. BLOWERS Each unit shall contain one forward curved, double width, double inlet blower. Blower wheel and housings are heavy gauge galvanized steel. All fans available with standard or Class II; forward curved or airfoil wheels. Blower wheels shall be statically and dynamically balanced before they are assembled and dynamically balanced after being installed in the fan section. Fan and fan section in accordance with ARI Standard 430. FAN SHAFT Shafts shall be solid steel, continuous diameter, turned, ground and polished. Each shaft shall be coated with a non-hardening rust inhibitor. Shaft critical speed shall be at least 1.25 times the maximum operating speed. BEARINGS Pillow block bearings shall be self-aligning, noise tested and have air conditioning fit. Average bearing life shall be in excess of 200,000 hours. Extended lube lines and grease fittings shall be furnished to each bearing to allow lubrication from outside the cabinet. COILS All coils shall be staggered tube design, have heavy wall copper headers, and die-formed plate type aluminum fins. Coil casings shall be constructed of 16 gauge galvanized steel. Water and steam coils shall have steel MPT connections. DX and heat reclaim coils shall have copper sweat connections. All coils shall be submerged in water and leak tested with 400 PSIG dry nitrogen. All chilled and hot water coils certified in accordance with ARI Standard 410. FACE AND BYPASS DAMPERS Dampers shall be internal or external, opposed blade type with inter-connecting linkage. Blade bearings shall be brass inserts and shall provide smooth operation and corrosion resistance. Small face area coils with internal bypass; large face area coils with external bypass. The external duct on external bypass to be insulated. HEATING-ONLY COIL SECTION One and two row heating coils can be housed in a specially designed slide-in casing and bolted directly to the 6

MECHANICAL SPECIFICATIONS MIXING BOX Mixing box can be furnished with or without an angular filter section and have either top and back or bottom and back openings. Openings can be furnished with or without parallel blade dampers, having standard or low leak dampers. Blade bearings shall be brass inserts and shall provide smooth operation and corrosion resistance. Section to have full access doors on each side with slip-joint hinges, quick-release latches and gasketing. DRIVE Drive components shall be of the highest quality and statically balanced. Drives are designed to be a minimum of 1.20 or 1.50 times the rated motor horsepower. MOTORS Motors shall be mounted inside the blower section, on a heavy gauge steel channel, with the drive side out to provide access to the drive. Optional 1'' internal spring vibration isolators for sizes 14-65 and rubber-in-shear isolators for sizes 03-12. FLAT FILTER SECTION Section available for 2 thick throwaway, cleanable, or 30% efficient pleated-media type filters. Section available with 4 thick 30% efficient pleated-media type filters. Sections have full access both sides with removable doors with slip-joint hinges, quick-release latches and gasketing. Filter velocities not to exceed recommended maximum face velocities. ANGULAR FILTER SECTION Section available for 2 thick throwaway, cleanable or 30% efficient pleated-media type filters. Sections have full access both sides with removable doors with slip-joint hinges, quickrelease latches and gasketing. Filter velocities not to exceed recommended maximum face velocities. ELECTRIC HEAT SECTION Section shall be of open coil heater type and shall have external control panel. All heating sections shall be supplied with internal wiring of controls & contactors. Automatic reset thermal cut-out and air flow pressure switch. ACCESS SECTION Used where access is needed to a particular area. Full access both sides with removable doors with slip-joint hinges, quick-release latches and gasketing. DIFFUSER SECTION Factory installed with perforated plate to assure even distribution of discharge air across coil, required for proper heat transfer. BAG FILTER SECTION Each section has full size gasketed doors for access on both sides. Unit equipped with 2 pre-filter track and 22 bag filters. Cartridge Filter Sections have tracks for 12'' Cartridges. Discharge arrangement is always specified with the unit viewed so that airflow is from left to right through the coil section. The available arrangements are numbered in clockwise sequence. Some arrangements are not available in certain sizes. NOTE: Motor and coil connection locations are specified looking into the return air intake of the unit. 7

Air Handler