Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option Internal Vibration Isolation Option 8101 E. Kaiser Blvd., Suite 110 Anaheim, CA 92808 Tel (714) 529-1935 Fax (714) 529-7203
Vertical Configuration External Vibration Isolation Horizontal Configuration Internal Vibration Isolation Internal Configuration Construction Detail 2
NOMENCLATURE L H S - 21 F FAN PRESSURE CLASS L = Low M = Medium UNIT ARRANGEMENT H = Horizontal V = Vertical B = Blow-Thru 1 1 Blow-Thru units are always horizontal arrangement 2 All Vertical and all Blow-Thru units must use Long coil section FAN TYPE F = Forward Curved A = Airfoil NOMINAL FACE AREA Sq. Ft. - Large Coil COIL SECTION S = Standard L = Long 2 H = Heating Only N = None GENERAL DESCRIPTION The Central Station Air Handler is an industrial grade product with heavy gauge mill-galvanized steel framing and sheet metal throughout. Designed specifically for the HVAC industry with a full range of options and accessories, these units are also ideal for custom or design-and-build projects in refrigeration or air conditioning. Units are a single blower, internally mounted motor design. Each blower section has hinged access panels on both sides for service convenience. Air conditioning units are available for both low and medium pressure applications. The standard configurations available in most models include forward curved and airfoil wheels, with or without inlet vanes; horizontal and vertical draw-thru and horizontal blow-thru; internal or external fan isolation. Continuous diameter solid steel blower shafting is used throughout the line, resulting in large bearing diameters and low bearing loads. The highest quality grease lubricated bearings are selected to assure 200,000 hours average service life. Each rotating assembly, including fan wheel, shaft, sheaves, belts and motor, is balanced after final assembly to assure smooth, quiet performance. Standard coil options include chilled water or direct expansion cooling coils; hot water, steam and heat reclaim heating coils plus electric heat sections to provide complete comfort and environmental conditioning. * Cooling Capacity 4 row 8 FPI Coil @ 500 FPM Air Velocity: Heating Capacity 1 Row 8 FPI Coil @ 500 FPM Air Velocity: A (Water) 80 DB/67 WB Ent. Air, 2.4 GPM/Ton, 45 Ent. Water B (Dir Exp) 80 DB/67 WB Ent. Air, 45 Refrigerant Temperature C (Dir Exp) 75 DB/62.5 WB Ent. Air, 40 Refrigerant Temperature Steam 60 DB Entering Air, 5 PSIG Steam Width is left-to-right dimension facing blower discharge. Length includes fan & standard coil section (Horizontal Arrangement) 3
STANDARD CONSTRUCTION AND FEATURES Nut & Bolt Construction (except filter racks riveted inside of filter section) Heavy Gauge Mill-Galvanized Steel Sheet Metal & Framing Single Blower-Wheel Design Solid Steel Fan Shafts; Continuous Diameter, Turned, Ground & Polished Pillow-Block Bearings; 200,000 Average Service Life Lube Lines for blower Bearings Extended to Outside Internally Mounted Motor Adjustable Motor Base Blower & Drive Components Dynamically Balanced after Fabrication Hinged Access Doors w/easy Lift-Off Feature Double Drain Pan (insulated between pan and outer casing) 4
STANDARD CONSTRUCTION COIL CONSTRUCTION AND OPTIONS OPTIONAL FEATURES Copper Tubing Staggered Tube Pattern Die-formed Plate Type Aluminum Fins Mill-galvzanized Steel Casing 16 gauge Heavy Wall Copper Headers Connections: Water & Steam Coils: Steel MPT Direct Expansion: Distributor inlet Sweat Copper Suction Condenser & Reclaim: Sweat Copper Leak Tested Under Water @ 400 PSIG Dry Nitrogen 5 3/8, 1/2 & 5/8 Tubing (except steam is (5/8 O.D. only).025,.035 and.049 Wall Copper Tubes (5/8 O.D. only) 4 Thru 14 Fins Per Inch Copper Fins, Polyester Coated Fins.010 thick Aluminum Fins Phenolic Coated Coil Dipped After Fabrication Type 304 Stainless Steel Casing Copper MPT Connections in lieu of Steel Additional circuits: Face Split Row Split Intertwined
MECHANICAL SPECIFICATIONS GENERAL Each unit shall be furnished with components as specified. All units and accessories shall be constructed of heavy gauge galvanized steel as specified in the Physical Data table on the back cover on this brochure. Air handling units of type and size shall be in accordance with the Air conditioning and Refrigeration Institute (ARI) Standard 430. FAN SECTION Fan section shall have an access door on each side secured by quick-release latches. Hinges shall be of the slip joint type allowing easy removal of doors. All doors shall be generously gasketed. Fan sections used in cooling application shall be internally insulated with standard 1'' inch thick, 2.2 lb. (optional 1 inch 3 lb. foil-faced) bonded mat fiberglass insulation, affixed with a waterproof adhesive. All insulation shall comply with the requirements of NFPA 90. Fan sections for heating and ventilating units are not insulated except as specified option. COIL SECTION Heating and cooling - Cooling coil sections shall be internally insulated with standard 1'' inch thick, 2.2 lb. (optional 1 inch 3 lb. foil-faced) bonded mat fiberglass insulation, affixed with a waterproof adhesive. Insulation shall comply with the requirements of NFPA 90. Heating and ventilating coil sections are not insulated. Horizontal unit arrangements shall be available with standard and long coil sections. Vertical unit arrangements shall be available with a long coil section only. Coil sections with coils higher than 42-inch finned height shall have an intermediate drain pan (between top and bottom coils) with plastic drain tubes extending into main drain pan. Heating coils shall be considered standard in either the preheat or reheat position. Cooling coils shall be mounted on entering air side of coil section to prevent water carryover into the fan section. Standard and long coil sections shall have a removable panel on each side to allow easy coil access and removal. Optional hinged and latched access door available on return-bend side of coil section. Standard and long coil sections shall have a double drain pan with insulation between the inner and outer pan. The drain pan shall have welded corners and a 1-1/4 inch MPT drain connection on each side for positive draining. Optional stainless steel drain pans for corrosive applications. fan section. Heating only coils with more than two rows shall be bolted directly to the fan section without a casing. No insulation can be applied. BLOWERS Each unit shall contain one forward curved, double width, double inlet blower. Blower wheel and housings are heavy gauge galvanized steel. All fans available with standard or Class II; forward curved or airfoil wheels. Blower wheels shall be statically and dynamically balanced before they are assembled and dynamically balanced after being installed in the fan section. Fan and fan section in accordance with ARI Standard 430. FAN SHAFT Shafts shall be solid steel, continuous diameter, turned, ground and polished. Each shaft shall be coated with a non-hardening rust inhibitor. Shaft critical speed shall be at least 1.25 times the maximum operating speed. BEARINGS Pillow block bearings shall be self-aligning, noise tested and have air conditioning fit. Average bearing life shall be in excess of 200,000 hours. Extended lube lines and grease fittings shall be furnished to each bearing to allow lubrication from outside the cabinet. COILS All coils shall be staggered tube design, have heavy wall copper headers, and die-formed plate type aluminum fins. Coil casings shall be constructed of 16 gauge galvanized steel. Water and steam coils shall have steel MPT connections. DX and heat reclaim coils shall have copper sweat connections. All coils shall be submerged in water and leak tested with 400 PSIG dry nitrogen. All chilled and hot water coils certified in accordance with ARI Standard 410. FACE AND BYPASS DAMPERS Dampers shall be internal or external, opposed blade type with inter-connecting linkage. Blade bearings shall be brass inserts and shall provide smooth operation and corrosion resistance. Small face area coils with internal bypass; large face area coils with external bypass. The external duct on external bypass to be insulated. HEATING-ONLY COIL SECTION One and two row heating coils can be housed in a specially designed slide-in casing and bolted directly to the 6
MECHANICAL SPECIFICATIONS MIXING BOX Mixing box can be furnished with or without an angular filter section and have either top and back or bottom and back openings. Openings can be furnished with or without parallel blade dampers, having standard or low leak dampers. Blade bearings shall be brass inserts and shall provide smooth operation and corrosion resistance. Section to have full access doors on each side with slip-joint hinges, quick-release latches and gasketing. DRIVE Drive components shall be of the highest quality and statically balanced. Drives are designed to be a minimum of 1.20 or 1.50 times the rated motor horsepower. MOTORS Motors shall be mounted inside the blower section, on a heavy gauge steel channel, with the drive side out to provide access to the drive. Optional 1'' internal spring vibration isolators for sizes 14-65 and rubber-in-shear isolators for sizes 03-12. FLAT FILTER SECTION Section available for 2 thick throwaway, cleanable, or 30% efficient pleated-media type filters. Section available with 4 thick 30% efficient pleated-media type filters. Sections have full access both sides with removable doors with slip-joint hinges, quick-release latches and gasketing. Filter velocities not to exceed recommended maximum face velocities. ANGULAR FILTER SECTION Section available for 2 thick throwaway, cleanable or 30% efficient pleated-media type filters. Sections have full access both sides with removable doors with slip-joint hinges, quickrelease latches and gasketing. Filter velocities not to exceed recommended maximum face velocities. ELECTRIC HEAT SECTION Section shall be of open coil heater type and shall have external control panel. All heating sections shall be supplied with internal wiring of controls & contactors. Automatic reset thermal cut-out and air flow pressure switch. ACCESS SECTION Used where access is needed to a particular area. Full access both sides with removable doors with slip-joint hinges, quick-release latches and gasketing. DIFFUSER SECTION Factory installed with perforated plate to assure even distribution of discharge air across coil, required for proper heat transfer. BAG FILTER SECTION Each section has full size gasketed doors for access on both sides. Unit equipped with 2 pre-filter track and 22 bag filters. Cartridge Filter Sections have tracks for 12'' Cartridges. Discharge arrangement is always specified with the unit viewed so that airflow is from left to right through the coil section. The available arrangements are numbered in clockwise sequence. Some arrangements are not available in certain sizes. NOTE: Motor and coil connection locations are specified looking into the return air intake of the unit. 7