MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

Similar documents
MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

MAR SERIES Fluorescent Lighting for Hazardous Locations

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SXPJ SERIES S X azz.com/rigalite

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

FPF LED SERIES F P F L E D. Linear Non-Metallic Fixture for Food Processing

DuraPro Hazardous Area Fluorescent

Applications. Illustrated Features

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

MagnaPro Hazardous Area Drop Lens Fluorescent

AFL FLOODLIGHT SERIES

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Fluorescent Lighting: Enclosed and Gasketed

Areamaster LED Flood/High Bay Luminaires

Applications. Standard Materials

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Lighting: Explosionproof Area HID. Applications. Standard Materials

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Haz. HazMax Intrepid/nm TECHNICAL SPECIFICATIONS

Applications. Standard Materials. Certifications and Compliances


Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Vaporproof Strip - 4 Foot 1-3 Lamps

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Standard Materials. Certifications and Compliances

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

N2MV Series W Non-metallic

003 3 foot foot RUN Nominal Length* * For actual lengths see

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

Champ MLL LED luminaires

LED Flat Panel Luminaires

L1L Series. LED Luminaire for Harsh and Hazardous Environments

COMPACT FLUORESCENT EMERGENCY FIXTURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

72-P-SD. MOD 72 Pendant Semi-Direct. Ordering Guide. Key Features 72-P-SD. Fixture Type: Project Name: Quick Find litecontrol.com

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

LED Flat Panel Luminaires

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

Class I Division 2 LED Pivoting Light - 4 foot 3 lamp - LED Oil Rig Fluorescent Replacement

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

Lighting Systems Argus-7


SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

LED Flat Panel Luminaires

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

Seem mm 4.50" 4.00" 101.6mm. Narrow 4" linear fluorescent allows for both individual or continuous runs.

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

2 LED Designer Series

MOGUL BASE HID FIXTURES

KH Series Kemlux III Enclosed/Gasketed

apollo 8 patient bed light with LED options features dimensional data performance

LEN Series 2x2 / 2x4 LED

Compact Sheet-steel Emergency Light Fitting Series 6118/1

LED lighting for hazardous areas Champ MLL LED Luminaires. Champ MLL. LED luminaires for hazardous areas

DURA BAY LINEAR SERIES

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Nera. detail. fixture information. Unique aesthetic inspired by the visual void design philosophy. Luminaire sizes available in 2 x2, 3 x3 and 4 x4.

C4X4L10DL Calculite LED 4 1/2" x 4 1/2" downlight

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

Compact Sheet-Steel Light Fittings Series 6114/1

Test Sample Description Catalog Number: Description:

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

Example: DWAE51L840-4-UNV-MD360W. Lumen Package Color Temp. Length Voltage Driver Options Installed

Seem 6. Narrow 6 aperture slot fluorescent luminaire that integrates with the ceiling for a clean unobtrusive aesthetic.

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

Standard Grade 14 Inch Reflector. Ordering Information

WALL MOUNT. Notes: Project: Type: PROJECT INFORMATION DIMENSIONS SECTION VIEWS ORDERING CODE PRODUCT SPECIFICATIONS

Highbay Fluorescent - 3 or 4 Lamp Curved Profile Design

Sealtight LED Luminaire

Transcription:

MHDS SERIES Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations Class I, Division 2, Groups A, B, C & D Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 198A Marine Outside Type CSA C22.2 #137; C22.2 #213 CUL C Ambient Temperature IP66 M H D S

MHDS SERIES Marine Heavy Duty Fluorescent Luminaire for Hazardous Locations Stainless steel housing. 3/4 in. NPT aluminum hub. Captive stainless steel latches. Stainless steel mounting brackets. Heavy duty aluminum ballast tray. Heavy duty injection molded lens with reinforced corners. Housing: Corrosion resistant stainless steel housing Water tight gasket attached to the lens Captive SS latches Heavy duty aluminum ballast tray 3/4 in. NPT aluminum conduit hubs Diffuser: High Impact DR acrylic diffuserpolycarbonate option available Mounting: Stainless steel mounting brackets standard 6 RIG-A-LITE

FLUORESCENT Catalog Number Logic MHDS 1 2 3 4 6 1 2 3 BASIC SERIES MHDS Stainless Steel Fluorescent Class I, Division 2, Groups A, B, C and D Class II, Division 2 Groups F & G Class III UL 844 Hazardous Locations UL198A Marine Outside Type CSA C22.2 #137; C22.2 #213 CUL C Ambient Temperature IP66 LAMP CURRENT/LAMP WATTAGE 8 = 8mA, 6 Watt 43 = 43mA, 34 Watt (export only) 42 = 42mA, 4 Watt (Slimline) 26 = 26mA, 32 Watt T8 T8HO = T8HO, 44 Watt T = T, 28 Watt THO = THO, 4 Watt NOMINAL FIXTURE LENGTH 4 = Four Foot 4 NUMBER OF LAMPS 2 = Two Lamp 3 = Three Lamp (T8, T & THO Only) VOLTAGE/FREQUENCY U = 12 thru 277V /6HZ N = 347 thru 48V /6HZ H = 347V 6HZ 6 OPTIONS1 P = Polycarbonate Lens F = Single Fuse 2 FB = Fuse Block 2 TB = Terminal Block TW = Thru Wire Cable Installations Only PM = Pendant Mount EM = Emergency Battery Backup EM NON = Non-Hazardous Emergency 3 = SS3L Housing OB = Out Board Option 1 Consult factory for pricing. 2 Fuse option not available for marine listed fixtures. Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. www.rigalite.com 7

Options FLUORESCENT Class I, Division 2, Groups A, B, C and D Class II, Division 2, Groups F and G Zone 2, Groups IIA, IIB and IIC UL 198A Marine Outside Type UL 844 Hazardous Locations Suitable for indoor use Corrosion resistant stainless steel housing Water tight gasket attached to lens High impact acrylic lens with stainless steel lens tethers Captive SS latches Heavy duty aluminum ballast tray Stainless steel mounting brackets Description Voltage Catalog Number 32 Watt Instant Start F32T8 Medium Bi-Pin 26mA Lamps, 48 12-277V /6 HZ MHDS26-4-2-U Four Foot Fixture 44 Watt Rapid Start T8HO Medium Bi-Pin 26mA Lamps, 48 28 Watt, Rapid Start T Miniature Bi-Pin Lamps, 48 12-277V /6 HZ MHDST8HO-4-2-U 12-277V /6 HZ MHDST-4-2-U 4 Watt, Rapid Start THO Miniature Bi-Pin Lamps, 48 12-277V /6 HZ MHDSTHO-4-2-U Certification Guide Model Ambient Temperature Class I, Div. 2 Groups A, B, C & D Class II, Div. 2, Groups F & G, Class III Supply Wire Suitable Temp C ( C) MHDS 26 4 T4 T3C 9 MHDS 26 T4A - 9 MHDS T, THO 4 T4 T3C 9 MHDS T, THO T3C - 9 MHDS T8HO 4 T4 T3C 9 MHDS T8HO T4A - 9 8 RIG-A-LITE

FLUORESCENT Fixture Dimension (inches) A D B C E Nominal Fixture Boxed Shipping Volume Length A B C D E Weight (Boxed Fixture) Four Foot Fixture 6.88. 7.88 36.63 3.13 3.7 lbs. 2. cu. ft. Accessories Fixed Mounting Kit Stainless Steel Fixed 4 Catalog Number: 37 Shipping Weight: 2 lbs. www.rigalite.com 9

FLUORESCENT Candlepower Distribution MHDS26-4-2 Coefficients of Utilization PhotometricData Deg. Parl. 22. 4. 67. Norm % Effective Ceiling Cavity Reflectance rcc 8 1 1 2 3 4 6 7 8 9 9 1 11 12 13 14 1 194 194 17 978 867 718 31 3 14 38 1 4 194 192 3 13 912 789 632 44 268 147 12 78 41 2 194 192 177 14 991 96 78 61 463 314 261 19 7 2 7 194 188 19 18 6 11 899 747 98 432 36 331 249 134 37 14 194 19 198 113 193 143 932 781 631 48 42 373 292 172 7 8 1 % Wall Reflectance rw Room Cavity Ratio RCR 3 1 3 1 3 1 Effective Floor Cavity Reflectance 2%.93.93.93.84.84.84.74.74.74 1.76.71.66.68.64.61.9.7.4 2.64.7.1.7.2.47.49.46.43 3..47.41.49.43.38.42.38.34 4.48.39.33.43.36.31.37.32.28.42.34.28.38.31.26.33.28.24 6.37.29..34.27.22.29.24.2 7.33.26.2.3.24.19.26.21.18 8.3..17.27.21.17.24.19.1 9.27.2.1.2.19.1.22.17.13 1.2.18.14..17.13.2.1.12 Candlepower Distribution MHDS26-4-3 Deg. 1 2 3 4 6 7 8 9 9 1 11 12 13 14 1 Parl. 18 1466 131 176 797 474 211 8 6 22. 38 194 14 1368 1184 948 66 42 22 13 117 61 3 4. 38 16 1487 139 117 9 694 471 392 34 9 1 3 11 3 67. 32 3 27 199 11 1348 112 987 647 48 496 373 21 6 2 8 Norm 3 47 4 16 1398 1172 947 686 64 6 438 27 86 12 2 Coefficients of Utilization % Effective Ceiling Cavity Reflectance rcc % Wall Reflectance rw Room Cavity Ratio RCR 8 1 3 1 3 1 3 1 Effective Floor Cavity Reflectance 2%.93.93.93.84.84.84.74.74.74 1.76.71.66.68.64.61.9.7.4 2.64.7.1.7.2.47.49.46.43 3..47.41.49.43.38.42.38.34 4.48.39.33.43.36.31.37.32.28.42.34.28.38.31.26.33.28.24 6.37.29..34.27.22.29.24.2 7.33.26.2.3.24.19.26.21.18 8.3..17.27.21.17.24.19.1 9.27.2.1.2.19.1.22.17.13 1.2.18.14..17.13.2.1.12 PhotometricData 17 RIG-A-LITE