MODEL P INSTALLATION INSTRUCTIONS

Similar documents
MODEL INSTALLATION INSTRUCTIONS. 12 Volt UTILITY PUMP

INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

MODEL SS INSTALLATION INSTRUCTIONS

MODEL H INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

INSTALLATION INSTRUCTIONS MODEL Z Z Z Z 1.5 HP 115/230V Z Z 2.0 HP 115/230V Z Z

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Material required for drilled well application (indoor use only)

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

GARDEN HOSE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SUNC3000 / Item #40885

Owner s Manual Drill and Light Weight Portable Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

ESE Series Cast Iron Sewage Pumps

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Matala. VersiFlow Series. Instruction and Maintenance Manual

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

GeyserMax-Flow Series

SUBMERSIBLE WATER PUMPS

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Installation & Operating Manual

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

INSTALLATION & OPERATION MANUAL

Powerful & Intelligent Submersible Pumps

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SUBMERSIBLE PUMP HSE RANGE

Operating Manual Includes Pumps: PG-9000 Part #R809606

SUBMERSIBLE PUMP HSE RANGE

StormPro BA Series Sump Pump

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SuperFlo 9,000 High Volume Pump Product Manual

HALLMARK INDUSTRIES INC

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

M-3025CB-AV Fuel Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

HydraPump Submersible Owner s Guide

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SUBMERSIBLE WATER PUMP

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

8000 / 10,000 / 12,000

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Installation & Operating Manual

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

THERE IS NO OTHER EXPRESS WARRANTY.

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

SPEED KEY After the fan has started, press to change fan speed in sequence of: Low - Medium - High. The corresponding indicator will illuminate.

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Cascade Owners Manual

Submersible Effluent Pump

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Description of the Power Nozzle Accessory Kit 4

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

OWNERS MANUAL ECODIVER

StormPro BCV400 Sewage Ejector Pump

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Unilift KP 150, KP 250, KP 350

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Trouble Shooting Guide EWA, 3-phase (D2422)

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

User s Manual. Automatic Switch-Mode Battery Charger

JABSCO & Series 1½ 80 SIZE UTILITY Pump

OPERATION & MAINTENANCE INSTRUCTIONS

Submersible Tank Pump

SUPER PUMP OUT SYSTEM

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE WATER PUMP

SUBMERSIBLE SUMP PUMPS

Owners Manual: - Pumps

SUBMERSIBLE MINI-PUMP

PRE-PLUMBED SEWAGE SYSTEM

6 Litre Oil-Less Air Compressor

STEP-BY-STEP INSTALLATION GUIDE

Installation & Operating Manual

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

INSTALLATION INSTRUCTIONS

Transcription:

WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. INSTALLATION INSTRUCTIONS MODEL 300308P UTILITY PUMP Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. NEVER RUN THIS PUMP DRY 2004 2015 BUR-CAM Printed in Canada 300245

SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C D CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PRO- TECTION. NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. APPLICATION FEATURES Designed to use to empty waterbeds, aquariums, transfering and / or removing water from roof tops, puddles, etc. This utility pump is designed for a portable application, for dewatering around homes and farms. Non corrosive material. Stainless steel mechanical rotary seal. Thermal and overload protection. CAPACITY: 5 450 US GPH 20 275 US GPH 40 75 US GPH FRICTION LOSS IN PIPE NOT INCLUDED 1/12HP, 115VAC, 60Hz. NOTICE This unit is not designed for applications involving salt water or brine. Use with salt water or brine will void warranty. 2 FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029

IMPORTANT INFORMATIONS The automatic thermal overload protection shuts the motor off when it overheats because of low voltage, trash in the pump or other problems. Normally, motor cools in 10 minutes and restarts automatically. If this pump is used for pumping mildly abrasive liquids like lake water, keep hose inlet above mud and sand. All severely abrasive liquids will wear the pump quickly and void warranty. This pump will handle most common waterlike liquids (water, brines, light lube oil, etc) at temperatures of 0 F to 120 F (-18 C to 50 C). Thick liquids, fuels (gasoline etc) or other flammable liquids, solvents, thinners and strong acids are totally prohibited. Never operate the pump against a closed or clogged discharge. Use 1/2 (13mm) minimum pipe. Note that the best performance occurs when the suction line is as short and direct as possible. For any lines of 40 or longer, install a 3/4 (19mm) pipe size. After few months of inactivity, the impeller may get bone dry. If this happens, replace the impeller. The motor is drip-proof but not waterproof. Motor brushes should be replaced every 300 hours of use. Remove brush cap to replace brush only. Never add oil to motor or brushes. PRIMING This unit will prime to 10 feet if you follow these instructions. Drop 1 tablespoon of vegetable oil into pump inlet and outlet before each use. Add water to suction pipe and install a foot valve to make easier priming. For a succion from 10 to 20 depth, a foot valve is mandatory and the suction line must be filled before pump start. If the pump does not prime within one (1) minute, unplug from receptacle and perform next steps: Air leaks in suction pipe. For a garden hose, be sure fittings are tight and rubber washers are in good condition. For other pipe types, use teflon tape on all threads. Verify foot valve action FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029 3

Verify for collapsed suction hose or plugged suction line Verify for liquid supply too far away or too far below pump (more than 20 feet) Worn out or damaged impeller Severe abrasive wear of volute plate or pump body. Remove pump cover to access these parts. Proceed carefully to avoid damaging the 0 ring. INSTALLATION STEPS STEP 1 STEP 2 STEP 3 STEP 4 Fill liquid inlet and outlet of pump with one (1) table spoon of vegetable oil. Install suction and discharge line Plug cord into a 3 prong 115 VAC receptacle. Unplug pump when liquid supply is exhausted. The overheat due to dry running will damage impeller or weld it to the pump body. MAINTENANCE The shaft motor seal is generally good for the life of the pump. When shaft seal leaks, it is because enough abrasives have been pumped to wear deep grooves in the shaft under the seal. In this situation, the purchase of a whole unit will cost less than repairs (motor and pump). Brush replacement is done quickly and easily. Unscrew brush cover, then remove spring and worn brush. Insert the replacement brush and spring kit in the same position and replace brush cover. Never drop oil in brush area. This may damage the motor and void warranty. Spring and brush Impeller replacement is also easy to do. Remove pump cover screws and cover. Remove worn impeller. Clean out inside of pump body and examine the volute plate. If worn, turn over. Wipe a small quantity of oil and install the replacement impeller by twisting in clockwise direction. This will blend the blades in place. Using screws, replace pump cover. Do not overtight. Cap 4

The following situations void the warranty WARRANTY LIMITATION Running pump dry Handling severe abrasive solution, fuels (gas etc.) or other flammable liquids, thinner, acid or other strong chemical solutions. Handling liquids hotter than 120 F (50 C). Normal wear. user abuse, including immersing pump Commercial or industrial use. Alterations to electric cord or plug. Wholly or partly disassembled motor. REPAIR PARTS MODEL 300308P UTILITY PUMP REF # DESCRIPTION 1 300556 Impeller 2 300578 Volute plate 3 300589 Puddle scoop 4 300588 Hose 5 300559 Carbon brushes kit (2) 6 300582 Sand slinger 7 300580 Rubber seal 8 300581 Snap ring 9 300583 Complete motor 115 Volt 10 300584 Brush house cover 11 300585 Rotor and fan 12 300586 Fan cover 13 506053S Pump body O ring 14 300587 Pump body screws (2) 15 300579 Pump body 16 300575 Pump cover screws (4) 17 300576 Pump cover 18 300590 Motor support 19 300593 Complete motor 12 Volt (300301P) 13 16 14 17 1 2 15 4 3 12 11 9 7 8 6 18 5 10 Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS 5

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Plug disconnected Corroded plug Low water level Thermal overcharge Defective switch/float Defective motor Improper float position Turn switch to on position Replace Reset Re-install Clean prongs Add water and verify Cool the motor Replace Replace/repair Check movement Pump does not deliver to full capacity. Jammed impeller Plugged check valve Blocked suction/inlet Discharge leak Blocked line/pipe Worn impeller Defective motor Clean Clean/replace Check for debris in pit and clean Repair Check for debris or ice Repair/replace Replace 6 TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation.