ANTEK APPLICATED Turn-Key GC solutions

Similar documents
Antek Gas Chromatography Products: A Guided Tour Through Industry

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

TSHR 7000 series TN-TS-TX analyzer

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Beverage Grade Carbon Dioxide

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

TSHR 6000 series TN/TS/TX analyzer

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Refinery and Natural Gas Analysis

breakthrough versatility

GC Method Compliance and Large Valve Oven Application

S-PRO 3200 GC System for Sulfur Analysis

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

White Paper.

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Monitor Chlorine in Crude at Sub-ppm Levels

Application. Gas Chromatography June 1995

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Shimadzu's Total Solutions for the Hydrocarbon Processing Industry

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Live Crude Oil Volatility

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Using the PSD for Backflushing on the Agilent 8890 GC System

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

CERTIFICATE OF ACCREDITATION

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

On-Line Process Analyzers: Potential Uses and Applications

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

DANI Transformer Oil Gas Analyzer

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

Crude Evaluation Best Practices

LIABLE RESULTS AND RELIABLE RESULTS AND EXCEPTIONAL REPRODUCIBILITY

IFPAC 2003 Dr. Berthold Andres

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

C2, C3, C4 Monomer Analysis

Distillation process of Crude oil

Agilent and ASTM. Update on Recent Activities. Page 1

GAS CHROMATOGRAPHY LGC-A1 SERIES

Fast Gas Chromatography in the Refinery Quality Control Laboratory. Carl Rechsteiner CRechsteiner Consulting, LLC (Chevron retired)

Agilent Multimode Inlet for Gas Chromatography

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Crude & Petroleum Products Specification & Analysis

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

Reliable. Efficient. Economical. Distillation Technology ENGINEERING - EQUIPMENT - TURNKEY SYSTEMS

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Analysis of Petroleum Fractions by ASTM D2887

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

GTC TECHNOLOGY WHITE PAPER

Characterization of crude:

Pursuing high precision, speed, and ease of use

Lecture 3: Petroleum Refining Overview

Remote Process Analysis for Process Analysis and Optimization

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Siemens AG, 2008 MAXUM II

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

AC Reformulyzer M3. 75 Minutes Full Gasoline Analysis. Compliance with ASTM D 6839, EN and ISO Self Explanatory Operation


Technical Procedure for Gas Chromatography (GC-FID)

Agilent 6850 Series II Network GC System G2630A Performance Specifications

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

A Closer Look at ULSD. Mahesh Albuquerque Director

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

Refining/Petrochemical Integration-A New Paradigm

Thermo Scientific TITAN 4000 Total Nitrogen/Sulfur/ Chlorine Analyzer

Application of High-Temperature Simulated Distillation to the Residuum Oil Supercritical Extraction Process in Petroleum Refining

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration

Elemental Analysis Advanced

OIL REFINERY PROCESSES

X-ray Essentials from XOS Proven Performance

PILOT PLANT DESIGN, INSTALLATION & OPERATION Training Duration 5 days

Agilent 7693A Automated Liquid Sampler

Transcription:

ANTEK APPLICATED Turn-Key GC solutions

The ANTEK advantage Antek patents chemiluminescent nitrogen detection apparatus & method Antek introduces first total nitrogen chemiluminescence analyzer Antek opens operation as a laboratory instrumentation manufacturer s representative Antek designs and manufactures its first gas chromatograph 1965 1975 Applicating a GC for a specific function is often a complicated, tedious process. Not only does it require a great deal of GC expertise, but it also demands time and human manpower valuable resources that have become increasingly limited due to downsizing and tighter work demands. Yet, as regulations and methodologies continue to evolve, your laboratory can maintain the pace. ANTEK applies our technical expertise to your unique application challenge. We combine the most appropriate technologies to create a turn-key system that is not only specific to your needs, but is also guaranteed to generate a return on your investment. Our customers benefit from increased productivity at a reduced cost, while maintaining the competitive edge as regulatory mandates, analysis methods, and technologies evolve.

Antek applies chemiluminescence technology to GC detection, introducing first nitrogen-specific GC detector (CLND) Antek introduces first total sulfur chemiluminescence analyzer Antek receives first patent for chemiluminescent sulfur detection apparatus/method Antek receives second patent for chemiluminescent sulfur detection apparatus/method Antek introduces first microwave-heated GC column oven to analytical instrumentation market Antek introduces first sulfur chemiluminescent GC detector (SCD) Antek becomes an HP (now Agilent) Channel Partner Antek initiates our Applicated GC Program Antek introduces bench-top & first on-line GC units for methanol-specific measurements in crude oil 1985 1995 2005 EXPERTISE ANTEK is recognized as a long-standing chromatography leader. Our extensive background knowledge of real world sample challenges spans a broad range of applications, including: Petroleum Chemical Food & flavor Environmental Pharmaceutical We maintain active involvement in standardization committees and regulatory agency meetings, staying abreast of industry s continually changing needs. TECHNOLOGY ANTEK is the only multi-oven, multi-detector technology provider. Plus, our patented microwave heated GC column oven and chemiluminescent detectors provide maximum output at significant cost savings. As a value-added reseller of various chromatographic technologies, we offer an extensive selection of GCs, detectors, sampling devices, and software applications. Our fully customizable, turnkey systems allow virtually endless testing options. We offer systems for all standard chromatographic methods (ASTM, IP, DIN, GPA, CGSB, EPA, CARB, USP, etc.). SUPPORT ANTEK systems are backed by a highly knowledgeable worldwide support team. We guarantee a return on your investment: Save manpower & time Rest assured that your system will meet your specific testing needs Meet timely deadlines for regulatory compliance Upgrade existing equipment with cutting-edge technology Sample Introduction Capillary Columns Detectors Data System GC Mainframe Inlets & Flow Sources

Ultimate Application versatility From single column to multi-valve, multi-detector even multi-oven technologies your chromatographic analysis options are limitless! Contact us about your unique custom applications or to discuss upgrading an existing GC system. Petroleum Refining Liquid Hydrocarbons: Simulated Distillation (SimDist), gasoline through whole crude range: ASTM D 3710, 2887/extended, 5307, 6417, 6352, high temperature SimDist; optional sulfur & nitrogen analysis DHA Detailed Hydrocarbon Analysis: ASTM D 5134 DHAX (DHA including oxygenates): ASTM D 6729, 6730, 6733 Oxygenates in Finished Gasoline: ASTM D 4815 Ethanol Content in Denatured Fuel Ethanol: ASTM D 5501 Aromatics in Finished Gasoline: ASTM D 3606, 5580 BTX Analysis (benzene/toluene/xylene): ASTM D 6563 Sulfur Impurities in Benzene (thiophene): ASTM D 4735 Sulfur in Light Petroleum Liquids: ASTM D 5623 Detailed Front End of Whole Crude Samples Methanol in Crude (Antek benchtop or process GC available) GC/AED Multi-Dimensional Customized Analysis Refinery Gas & LPGs: RGA Refinery Gas Analysis: ASTM D 1945, UOP 539 Extended Fast RGA & Custom Refinery Gas/Liquids Analysis LPG: ASTM D 2163, 2504, 2505, 2712 Dissolved Gases (TOGA Transformer Oil Gas): ASTM D 3612 Sulfur Traces in Ethylene & Propylene: ASTM D 2420, 5303, 5623 Natural Gas & NGLs: ASTM D 5504; ISO 6974; GPA 2177, 2186, 2261, 2286 Environmental Trace Level Impurities in Wastewater: EPA methods Trace Benzene in Water Trace Oxygenates in Water Miscellaneous & Custom Specialty Speciated and Total Sulfur and/or Nitrogen Sulfur Impurities in Food Grade CO 2 Speciated and Total Nitrogen in Ethylene & Benzene Impurities in Propylene Paraffins, Aromatics & Napthenes in Hydrocarbons Trace Oxygenates in Hydrocarbons USP/Pharmaceutical Applications Detector FID Flame Ionization TCD Thermal Conductivity MS Mass Spectrometer PDD Pulsed Discharge SCD Sulfur Chemiluminescence CLND Nitrogen Chemiluminescence FPD/PFPD Flame Photometric NPD Nitrogen Phosphorous Specific AED Atomic Emission XSD Halogen Specific ECD Electron Capture PID Photoionization MDL <5 pg/sec <400 pg propane/ml Varies with operating/ionization mode Low ppb <1 pg/sec S <3 pg/sec N >10 3 S >10 4 P <0.4 pg/sec N <0.2 pg/sec P 2 pg/sec S Varies with operating conditions <0.008 pg/sec Varies with operating conditions ANTEK Sulfur & Nitrogen Detectors SCD / CLND Proven Chemiluminescence Technology Antek s 7090 Series provides a single flow path with dual channel chemiluminescence detection, saving laboratories time, bench space, and money. These unique detectors also provide a linear, equimolar response and have sensitivity that is stable over time, providing highly reliable results. Nitrogen, sulfur, or simultaneous nitrogen/sulfur buy one detector, add a second later Add to FID for 1 injection, 3 results Complete sample combustion enhances short- and long-term stability, equimolarity and selectivity Ideal for agriculture, biotechnology, biochemical, food & flavor, solid phase synthesis, organic synthesis, petrochemical, petroleum, pharmaceutical, & polymer/plastics

Dynamic Linear Quench-Free Ease of Approximate Typical Range Calibration Operation Use Cost Applications 10 7 $ Most organics 10 5 $ Fixed and inorganic gases; most organics 10 6 $$$$ Detection based on molecular structure 10 5 $ Helium photoionization mode: universal Electron capture mode: freons, chlorinated pesticides, halogen compounds >10 4 $$$ Sulfur species >10 4 $$$ Nitrogen species <20 pg/sec S $$ P, As, Si, S, N 0.9 pg/sec P (FPD) quadratic 10 5 $ Nitrogen and phosphorous species 10 4 $$$$ P, As, Si, S, N; PFPD tunable to 26 elements >10 5 $$ Halogen (at >10 4 ) >5x10 4 $$ Freons, chlorinated pesticides, and other halogen compounds 10 6 $$ Environmental applications, organics ANTEK Microwave GC Column Oven Save time & money while increasing your lab s performance By using microwaves to heat only the column, not the surrounding air and oven walls, ANTEK s Microwave GC Oven minimizes heating and especially minimizes cooling & cycle times shortening every analysis. Not only does the Microwave GC Oven enable Fast GC applications, but it also allows you to run conventional GC applications faster. Easily program incremental temperature ranges from 1ºC/minute to 360ºC/minute enabling ultimate application flexibility and speed. With ANTEK s Microwave GC Oven, two columns can be programmed independently inside your existing column oven doubling your laboratory s GC capability. UNLIMITED OPTIONS! Custom Options & Accessories Sampling Options Valve injectors: gas or pressurized liquid Autosamplers: wide variety for vial injections, headspace, SPME, etc. At-line, automated 24/7 sampling systems Data Handling & Instrument Control GC control & data acquisition software* Customizable SimDist software User-defined custom reports & calculation software *Please contact your ANTEK representative for details.

Real World solutions Solutions Study 1 CHALLENGE: More responsibility, fewer people SULFUR IN NATURAL GAS: FID/SCD Since we have more responsibilities and fewer people, it makes sense to outsource development and configuration. We get a better job than we would do ourselves, and it frees us up to focus on our big picture projects. A challenging aspect of our custom application involves not only separation of light sulfur compounds, such as H 2 S and COS, but also detection at sub-ppm levels. Our down-stream customers can tolerate very little COS. This system enables us to strictly monitor these sulfur levels, ensuring a quality product at delivery point. BOB ARMBRUSTER WILLIAMS ENERGY

Solutions Study 2 CHALLENGE: Reduced budget, multiple needs EXTENDED FAST REFINERY GAS Solutions Study 3 CHALLENGE: Complex SimDist application HYDROCARBON SIMDIST We chose to outsource the development of our GC application for a simple reason: it is more cost Realizing we didn t have the in-house resources to develop the complex application we needed, we effective and efficient to do so than to develop applications in-house. In the past, we usually required two or more instruments to generate the data we needed. Now, with our custom applicated GC from Antek, one instrument can handle refinery gas, LPGs and liquids, analyzing out to C 14 if necessary. Antek has benefitted our process by developing an extremely flexible, multipurpose GC capable of analyzing all our refinery liquids, off gases and LPG samples. The savings created with the purchase of one multi-purpose GC allowed us to purchase other needed laboratory equipment & supplies that would have been purchased outsourced our GC application to Antek. Our custom Antek-Applicated SimDist GC and data station allows us to quickly screen samples with a method that requires only seven minutes per sample. This is a distinct advantage over our automatic physical testing units, which require 30 minutes per sample and considerable time from our staff. Our laboratory receives 200 samples each week, representing numerous brands from retail gasoline stations throughout Alabama. It is our responsibility to quickly screen these samples, identify any that fail to meet state specifications, and take corrective action before the product can cause any damage. We have over several years. PAT TIERNEY HUNT REFINING Continued next page

ANTEK SimDist Solutions The quick, fully automated solution for routine screening, refinery stream characterization, & process control all from one multi-method GC!... successfully identified several distillation violations using our Antek-Applicated system. In more than one case, the violation was caused by inadvertent introduction of diesel fuel into a gasoline storage tank. Uncorrected, this problem would have led to dilution of the crackcase oil and engine failure. However, we were able to quickly respond with corrective action. The Antek-Applicated SimDist GC system APPLICATIONS Evaluate boiling range of various hydrocarbon fractions Gasoline Petroleum wax Jet fuel & diesel Gas & lube oils: engine oil volatility Crude oil HighTemp SimDist: residual/crude oil Simulate crude distillation tower performance Measure and predict yields from new crudes/products Optimize refinery operations Test quality of intermediate and final product Rapidly screen fuels for regulated final boiling point compliance Use in conjunction with SCD/CLND to determine sulfur and nitrogen contribution in various boiling fractions UNIVERSAL SIMDIST SOFTWARE has been an asset to our laboratory. It shows good correlation with our automatic physical distillation units, yet it offers two distinct advantages: speed and simplicity. VAUGHAN JOHNSON STATE OF ALABAMA DEPARTMENT OF AGRICULTURE ANTEK SimDist Systems: Whether you re building a new GC system or you re upgrading existing GC equipment, Antek offers fully applicated solutions for your SimDist method specifications. Our customizable software is compatible with virtually all Windows-based GC data acquisition systems. Custom SimDist calculations including D86, D1160, Noack, cutpoints and fractions are just a few of our standard options. Utilize the automatic export capability to deliver data and reports to your network destinations as specified by the user.

GC APPLICATIONS Turn-Key, Applicated GC Solutions Antek provides state of the art solutions designed to your custom specifications and/or adhering to standard methods as defined by organizations such as ASTM, GPA, UOP, etc. Utilizing our stream selector valve options, Antek systems can provide 24-hour/7-day automated analysis for your facility, including remote access via PC. Product & Application Support Hardware configuration, software installation, system verification Custom application development System upgrades of virtually any GC Spare parts and consumables Calibration and check standards Service and preventive maintenance Telephone and modem-link technical support Training courses Continual developments based on customer input Standard Features System development according to standard/customized methods Factory acceptance test, including calibration & certification data using customer-provided samples On-site installation and training Documentation for complete system Real-time remote diagnostics and support via modem One year warranty ANTEK Custom Calculation Software Add custom calculation capability to completely automate your Refinery and Custom Gas, Natural Gas, or LPG analyzer operations. The Antek Custom Report Generator is based on an easy to edit/ customize Excel-based format that is compatible with virtually all Windows-based GC data acquisition systems. CALCULATIONS INCLUDE: specific gravity vapor pressure BTU & calorific values molecular weight liquid volume percent weight percent user-defined values Universal SimDist software also available; see inside for details.