Professional Wireless Products

Similar documents
PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Features. Description. Table of Contents

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

Installation Instructions

Industrial Power Supplies

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

MODEL ELC-12/40-CVM-D BATTERY CHARGER

SCR Power Controllers

elabtronics Voltage Switch

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

Installation Instructions

EPS/ELA-Series User Manual EPS/ELA 250W

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

User Manual. Solar Charge Controller 3KW

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

55 Watt K Triple Series DC/DC Converters

Phoenix Inverter

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

SWITCH MODE POWER SUPPLY BASED BATTERY CHARGERS

SM361 RIG SWITCH CONSTRUCTION MANUAL

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Smart Battery Charger

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

SUBSTATION EQUIPMENT - Page 1 of 8

SECTION DC POWER SUPPLY/BATTERY CHARGER

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

DORADO MV DC/DC CONVERTERS 24V Input 12VDC 8A Output

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

GB60S 60W Single Output General Purpose Series

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

MODEL ELC-12/60-D BATTERY CHARGER

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

2W, Low Cost DIP, Dual Output DC/DC Converters

NTA Series Isolated 1W Dual Output SM DC/DC Converters

4707 DEY ROAD LIVERPOOL, NY PHONE: (315) FAX: (315) M.S. KENNEDY CORPORATION MSK Web Site:

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

BASIC ELECTRICAL MEASUREMENTS By David Navone

MODEL 422 Submersible Pump Controller

INSTALLATION & OPERATING MANUAL RW SERIES WALL-MOUNT RECTIFIERS

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

CHARGING UNIT DEM 313

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

A1P OPERATING MANUAL

PG02S Series 2W DC/DC CONVERTER, SIP-Package

8. Filter / Autoranging Rectifier Module (FARM )

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

A6Z OPERATING MANUAL

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

PSU EN54-4 Power Supplies

User Manual Solar Charge Controller 3KW

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

LESTRONIC II BATTERY CHARGER MODEL 07210

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

MODEL UC 14YFA. Hitachi. Power Tools TECHNICAL DATA AND SERVICE MANUAL CHARGER UC 14YFA SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

400W Solar Charger Maximum Power Point Tracker

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

SST-ST75F-ESS The essential silver standard

NOT RECOMMENDED FOR NEW DESIGNS

OUTPUT VOLTAGE 5V MAX.INPUT CURRENT 16.0A 12V 7.0A 12V 12V 24V 35.0A 28V 48V 12V 15V 24V 28V 23.0A 48V 12V 15V 24V 28V 48V 11.5A

Autoranging Multimeter

QUASAR KIT No THYRISTOR - TRIAC TESTER

Low and High Voltage Power Supplies

(typ.) (Range) Load

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Battery Power Inverters

(typ.) (Range) ±18 330# 89 MPW MPW

SELECTION GUIDE. Nominal Input Order Code 1 Voltage. Output Voltage

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Transcription:

Page 1 of 6 093115 Communications Power Supply and Battery Management Controller

Page 2 of 6 1.0 Introduction The 093115 is a 13.8 volt 15amp transformer isolated switch mode down converter designed to be used either as a stand alone supply or as a float style battery backed up supply when a lead acid battery is connected to its battery terminals. The 093115 was designed for wide mains voltage swings (240 +/- 20%) or (110+/- 10%) and high temperatures and vibration. The supply is rated at 60 C and has been NATA tested at 70 C at full load at a 280 volt mains. It was originally designed for railway trackside applications where such conditions apply. It is very suitable for applications where the mains supply is poorly regulated, and temperatures can be extreme. Models available are: Input Voltage 240 AC RMS or 110 AC RMS Output Current 15 amps DC out Output Voltage 13.8 V (all models) 1.1 Operation Principles 1.11 Stand Alone Supply The 093115 is constant voltage, constant current supply. When no battery is connected, the output voltage stays constant at 13.8 volts (adjustable) until the current limit (15 amps) is exceeded. The 093115 does not require a battery to be connected for normal operation and provides clean DC. 1.12 Battery Backed up Supply If a suitable back up battery is connected, the supply will run at its current limit until the battery is charged, that is until the constant voltage set point is reached. The current is shared between the communications load and the battery at all times, to a total of 15 amps. When the battery is charged, the 093115 stays at this set point (13.8 volts and adjustable), supplying the load current and a small trickle charge to the battery. Front panel LED indicators show the status of the supply and battery. When the battery is on charge the CONSTANT I LED is on. Within 0.1 Volt of the set point, the CONSTANT V LED comes on. The rate of rise of the terminal voltage on Lead Acid batteries is quite fast once they near full charge, so the LEDs form a reasonably accurate state of charge indicator in this mode. 1.13 Battery is Protected To avoid completely flattening the battery when the ac mains fail for extended periods, the 093115 isolates the load when the battery voltage (as seen at the 093115) drops to 11 volts. Approximately 1 volt of hysteresis is used to stop the disconnect function hunting. When the battery is disconnected in this way, a red BATTERY LO LED is lit. When the mains returns, the battery voltage rises rapidly to 12 volts, the load is reconnected automatically, and the 15 amps of available current is shared between the load and battery. A 12 VOLTS OK Led is lit. The terminal voltage rises to the set point (13.8 volts) when the battery is charged. At this point the supply goes into constant voltage mode, and the current to the battery drops off and a small trickle charge is left. 1.14 Load is Completely Protected Should the 093115 fail and present an over voltage condition (> 15 volts for 100uS), an independent MOSFET over voltage isolation switch isolates both battery and load from the supply, and a red ERROR LED is turned on. In the event that this over voltage is just a transient condition, the 093115 resets automatically. Should a charged back-up battery be connected with reverse polarity, the power supply and its load are disconnected automatically by a MOSFET switch, and a red POLARITY LED is connected. The 093115 resets automatically when the polarity is correct. This function operates even if load and battery connections are interchanged.

Page 3 of 6 2.0 Recharge Time The time to charge a battery depends upon the average draw from the load, the battery capacity, and the current limit of the 093115. Suppose that the average continuous base station draw is 10 amps, then 5 amps (15 amps minus 10) is available on average to charge the battery. A 55 AH battery would then take about 12 hours to recover. 3.0 Mechanical The 19-inch rack mount (3RU) case is manufactured from custom extruded aluminium, anodized black. (see drawing appended). All major components mount to the front panel, which forms the heatsink. The PCB is 70-micron copper (2x normal), secured with press fitted standoffs in many places to the heatsink. The main electrolytics have multiple terminations to the PCB, and heavy parts like Ferrites are bolted to the PCB, while other parts are supported with Loctite 480 adhesive. The rear safety cover is made of laser cut stainless steel vented to allow full airflow. The 093115 is convection cooled, and provision must be made for clear airflow around the product, as some 75 watts are lost as heat at full load. The dress labels are back screen-printed polycarbonate that is strongly resistant to mechanical damage. The annunciator LEDS shine through this. Height 3RU 132 mm Depth 70 mm behind panel, plus 25mm sockets etc. Width 19" rack 432 mm Weight 7 Kg approx Mounting 4 screws, rack mount 4.0 Temperature & Product Life The design ambient is -10 to +60C. The product has been tested at 15 amps and 280-volt mains for 15 hours in a 70 C ambient, and passes with all components within their published operating maximum temperatures. (Freight Rail Corp test requirement) At a 20 C ambient, the heatsink rises < 20 C in still air at 15 amps load and 240 V mains input. Free airflow is required around the product, and any enclosure must be designed to lose 75 watts to free air. At 70 C and full load, the electrolytics used have a typical design life of >7000 hours (case temp 83 C IEC 384-4 part). This rises to >140,000 hours at a 40 C continuous ambient. 5.0 Reliability The 093115 is manufactured using only well-specified and qualified high-grade commercial parts. In particular, the electrolytics are IEC 384-4 long life grade with a life exceeding 140,000 hours at 40 C continuous. C.M. Technology burns in all products to eliminate turn on failures. The MTBF is calculated to be >60000 hours at 50 C. 6.0 Maintainability & Warranty The 093115 is manufactured from discrete components soldered to a double sided, through hole plated solder masked 70 micron PCB. Complete parts lists, circuit diagrams, PCB overlays and a description of the circuit operation are included in the purchase price.

Page 4 of 6 7.0 General Specification Mains Input 50-60Hertz 240+/-20% (110 V available) Mains Isolation toroidal transformer to AS3108 E.T.S.A. APPROVAL No CS/1083/S.COMPLIES WITH AS3108-1990, & AS3193-1990 Nominal Output Voltage (1 amp) 13.80 adjustable Regulation (nominal mains 1-15 amps) <250 mv Constant Current Point 15 amp (20 amp) -0/+0.6 amp Hum, Noise & Ripple (15 A, 20 mhz BW) < 100mV pp < 15 mv rms Over Volts Lockout > 15.5 V +/- 0.4 V Battery Disconnect < 11.2 V +/ - 0.4 V Reverse Polarity protection Absolute Alarms (Optional) Floating contacts for AC Ok and DC good window, +11.4 to+14.8 V DC. Temperature -10 C to 70 C at 15 amps Expected Life (40 C ambient, full load) >15 years MTBF (calculated) >60,000 Hours @ 50C RFI (generated and immunity) Test Standard Report No M51138X E.M.C.Technologies P/L. as 093115 EN55022 (CISPR 22 :1994) EN50082-1 :1992 IEC 801-2 :1991 IEC 801-3 :1984 IEC 801-4 :1988 N 2672 AUSTEL Certified Component No. A96/PS/0096 8.0 Output Connection The battery and load have separate positive and negative Anderson Power Pole connectors. The alarm terminals are via a 4 pole screw terminal connector. All are mounted upon the back panel. 9.0 Input Connection The mains input is an IEC fuse switch assembly, UL recognized. A spare fuse, (UL recognized) is contained in the input socket. Three MOVs (UL recognized) clip transients, and RFI is rejected by a DELTA mains filter. (UL recognized.). Mains isolation is by a conventional 50/60 Hz iron core toroidal transformer to AS3108 (E.T.S.A. approval CS/1083/S, PPS20 complies with AS3108-1990, & AS3193-1990). This configuration gives excellent immunity from mains induced transients found in remote locations. 10.0 System Earth Bolt An M6 bolt is mounted to the case at the point of entry of the IEC mains input. 11.0 Alarms The alarms are floating contacts that are closed when the function is operating correctly. Alarm contacts for AC Mains OK and DC Power good (a Window from +11.4 to +14.8 volts) are provided. These are connected to a 4-pole screw terminal block on the back panel.

Page 5 of 6 12.0 Principles of Operation The 093115 are a constant current, constant voltage D.C. supply. The output voltage stays constant (within the limits of regulation) until the current limit of 15 or 20 amps is reached. The supply then goes into constant current. This provides a simple means of floating a lead acid battery if required. The operation of the supply does not require the battery to be present. 12.1 Down Converter The mains input is transient clipped by 3 MOV s (R41-43, Circuit Diagram PPS153-2.sch appended). A Heineman fuse (3ag) switch assembly is used to isolate the mains. The fuse is removed by twisting the input toggle. A Delta RFI filter provides ~ 40 db extra RFI filtering upon the input. The mains is then transformed down to 22 Volts by the mains toroid T6. The output is rectified (Bridge D27) and then filtered by C29 & C30. High frequency inductor L2 provides further RF rejection. The resulting 32 volts DC is chopped at 100 Khz by MOSFET Q6, and flywheel diode D24, and then filtered by L1 and C16 to produce 13.8 volts DC on C16. Regulation is achieved by altering the mark space ratio of the control signal via U5, the SMPS controller. 12.2 Current and Voltage Settings The voltage setting is via 20 turn pot R33 ( SET VOLTS on the PCB), which is available through the mesh of the safety case. It is used to set the constant voltage point, or the end point for the battery charging voltage. This is factory set at 13.75 volts. This pot adjusts the voltage feedback to U5, and is compared with the reference voltage (5.00 volts) generated by U5. The current in the down converter is sensed by current transformer T5, rectified by D25, and then a portion set by 20 turn pot R39 ( SET AMPS on the PCB) is sent to U5 for cycle by cycle current limiting. This limit is set to be 15 amps in the factory. The current pulses are integrated by L1 & C15 to make DC. This represents the constant current that is then shared between the battery and the load. 12.3 Charge State Indication The state of charge is indicated by the move from constant voltage (operation at the set point voltage) to constant current (battery terminal volts at less than the set point.) This is detected by comparator U6, that compares the reference voltage on pin 18, U5 to the output. The output of U6 drives two high brightness LEDS D20, 21 to show the state of charge. Transistors Q8, Q9 isolate this function when the mains is not on. 12.4 Over Voltage Protection Both LOAD and BATTERY terminals are switched via MOSFETS Q1 and Q3 respectively. The gates of these transistors are fed from a 24 volt charge pump, consisting of U2, diodes D3, D4 and capacitors C2 and C14. A comparator, U3, compares a separate precision reference D18, and the rail. If it should exceed 15.5 volts, the gate drive is removed and the outputs go open. LED D5 lights ( ERROR ). If this over voltage was just a transient, then the drive is re-applied. 12.5 Under Voltage In battery back up, the life of the battery is reduced if it is taken below 11 volts. The precision reference D18 and comparator U1 form a Schmitt Trigger with 1 volt hysteris. In operation, tripping U1 (battery <11.0 volts) removes the gate drive from Q1 and thus removes the load. The BATTERY LO led is lit. Hysterisis in the Schmitt means that the load is not re-connected until the battery reaches 12 volts. This happens almost immediately when the mains comes on, as the battery is in a (relatively) high impedance state at this time. 12.6 Upside Down

Page 6 of 6 Both the 093115 and the load are protected by Q1 and Q3 from an upside down connection of a battery to either of the LOAD or BATTERY terminals. The battery cannot be reverse charged either. Under these conditions the POLARITY LED is lit, and no power is available to the load. This protection circuit operates with or without mains being on. 13.0 History Revision 2.0 June 2000 Include 110 volt variant.