Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Similar documents
13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Title: WF Report No:

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

Introduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP

AMERICAN STRATEGIC MINERALS CORPORATION

Understanding BS 1363 Amendment No.4

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

CERTIFICATE OF APPROVAL No CF 5505 CONSORT ARCHITECTURAL HADWARE LTD

Testing of Baier Plasterboard to AS/NZS (Electronic copy (PDF format) original signed by author) Materials Scientist.

BS EN ISO :2006

CERTIFICATE OF APPROVAL No CF 5543 ASSA ABLOY SECURITY SOLUTIONS

EN 1154:1997 / A1:2002

SOUTH AFRICAN NATIONAL STANDARD. Plug and socket-outlet systems for household and similar purposes for use in South Africa

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

CERTIFICATE OF APPROVAL No CF 209 ROYDE & TUCKER LIMITED

FIRE TEST REPORT FH 5154

Fire resistance test in accordance with BS 476 Perko (R1, R2 & R21) and Perkomatic (R85) concealed door closers

BLAST CAPACITY ASSESSMENT AND TESTING A-60 OFFSHORE FIRE DOOR

SAMPLE RETENTION POLICY

BACS APPROVED BUREAU SCHEME SUPPORT GUIDELINES

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

BEFORE THE CANTERBURY REGIONAL COUNCIL. Act 1991 AND. of Plan Change 3 to the Waitaki Catchment Water Allocation Regional Plan

Guidelines for Safety Structure Homologation / Approval

Automatic Entrance Systems

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

Compatibility Between Electric Trains and Electrification Systems

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

CERTIFICATE OF APPROVAL No CF 5235 AVIANS INNOVATIONS TECHNOLOGY PVT. LTD

APPLICATION OF STAR RATINGS

ISLE OF WIGHT COUNCIL

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

ibusiness Banking Application Form Welcome to ibusiness Banking Need help completing this form? Adding an Additional Company to an existing Group

STEEL SECURITY DOORS. Standard Duty

Uniprep 2 Rotary scraping tool for pipes mm

A MODEL SYLLABUS FOR THE TRAINING OF TECHNICIANS INVOLVED IN THE EXAMINATION, TESTING, MAINTENANCE AND REPAIR OF PETROLEUM ROAD TANKERS

With Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006

TOPAS 2130A (Draft v3)

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103

Lloyd s Register Type Approval System Test Specification Number GT04

Driving with Medical Conditions

CERTIFICATE OF APPROVAL No CF 5418 C.ED. SCHULTE GMBH

GC108: EU Code: Emergency & Restoration: Black start testing requirement

British Gas Comments and Questions on Kelton Engineering Draft SMER

Composite Modification Workshop AC Appendices

PortableLadders > Ladder standards are changing > What does this mean for you? > What action do you need to take?

Rayleigh Instruments Ltd Raytel House Brook Road Rayleigh Essex SS6 7XH United Kingdom

ANNEX 3. RESOLUTION MEPC.278(70) (Adopted on 28 October 2016)

your and attach spreadsheet of 23 December 2003; and

RESOLUTION MEPC.278(70) (Adopted on 28 October 2016) AMENDMENTS TO THE ANNEX OF THE PROTOCOL OF 1997 TO AMEND THE INTERNATIONAL CONVENTION FOR THE

E/ECE/324/Rev.1/Add.38/Rev.2 E/ECE/TRANS/505/Rev.1/Add.38/Rev.2

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

Copyright Statement FPC International, Inc

CITY COUNCIL OF THE CITY OF NOVATO ORDINANCE NO. 1620

Vehicle Importer Terms and Agreement Form

Test report No

Declaration naming Richard J. Nixon and Dale Brand under section 106 of the Oil and Gas Conservation Act

Joint Operating Procedures for First Nations Consultation on Energy Resource Activities

ST. VINCENT AND THE GRENADINES

Test Report No

SECONDARY FUEL TESTING ARRANGEMENTS

REQUEST FOR PROPOSAL

Parking Control Bylaw 2014

IMO fuel oil consumption data collection system

BYD B-Box Limited Warranty Letter

08-Dec-10. VCA job number: CSL Date: 08 December Dear Sirs,

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

BOTHWELL CASTLE GOLF CLUB BUGGY POLICY

Report Number BTC 12261F

Examinations of Working Places in Metal and Nonmetal Mines. AGENCY: Mine Safety and Health Administration, Labor.

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

STATE OF NEW HAMPSHIRE PUBLIC UTILITIES COMMISSION DE PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE

Interface between Rail Vehicle Weights and Underline Bridges

The Waste Electrical and Electronic Equipment Regulations 2013 (as amended) Notification of grant of approval of an authorised treatment facility

PETROLEUM MEASUREMENT MANUAL THE PERFORMANCE OF TURBINE METERS IN LOADING GANTRIES - A REVIEW OF PROVING AND TEST DATA

Understanding design patent practice through the Jaguar Land Rover case

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

DEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016

ADDENDUM NO. 1. April 6, Project: Gas and Diesel Bid for School System Stations

ARCHITECTURAL MANUAL S08 DETENTION SECURITY TESTING ANSI/NAAMM HMMA May 00

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

Copyright Statement FPC International, Inc

INDUSTRIAL HAUL AGREEMENT

Report Number BTC 12024F

INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL

FIRE ASSESSMENT REPORT FAR 4659

E/ECE/324/Rev.1/Add.57/Rev.3 E/ECE/TRANS/505/Rev.1/Add.57/Rev.3

100-30(02) (External Projections)

STEEL SECURITY DOORS. Ultra Duty

Practical Assessment Record

Period: A - to Valid to FIA Class:

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

VEHICLE MAINTENANCE PROGRAM

Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS

Test report no

Transcription:

assessment report Title: The Fire Resistance Performance of Modified Doorsets WF Assessment Report No: 187254 Prepared for: Phoenix Door Panels Ltd. Westnewlands Ind. Estate Somersham Huntingdon Cambs PE28 3EB Date: 1st October 2009

Page 2 of 13 TABLE OF CONTENTS SECTION PAGE Executive Summary... 3 Introduction... 4 Assumptions... 4 Proposals... 4 Basic Test Evidence... 5 Assessed Performance... 6 Conclusions... 8 Validity... 8 Summary of Primary Supporting Data... 9 Declaration by Phoenix Door Panels Limited... 12 Signatories...13

Page 3 of 13 Executive Summary Objective This report provides a considered opinion regarding the fire resistance performance of doorsets, as supplied by Phoenix Door Panels Limited, similar to those tested under the references WF Nos. 167957/A and 168809, when including various modifications, specifically in relation to the glazing specification. Report Sponsor Address Summary of Conclusions Phoenix Door Panels Limited Westnewlands Ind. Estate Somersham Huntingdon Cambs PE28 3EB Glazed and unglazed doorsets as supplied by Phoenix Door Panels Limited and as described in this report, would be expected to provide 30 minutes integrity performance, if subjected to a test in accordance with BS 476: Part 22: 1987. Valid until 1 st October 2014 This report may only be reproduced in full. Extracts or abridgements of reports shall not be published without permission of Bodycote warringtonfire.

Page 4 of 13 Introduction This report provides a considered opinion regarding the fire resistance performance of doorsets similar to those tested under the references WF Nos. 167957/A and 168809, when including various modifications, specifically in relation to the glazing specification. The proposed doorsets as supplied by Phoenix Door Panels Limited, incorporating alternative glazing details, are required to provide a fire resistance performance of 30 minutes integrity, with respect to BS 476: Part 22: 1987. FTSG The data referred to in the supporting data section has been considered for the purpose of this appraisal which has been prepared in accordance with the Fire Test Study Group Resolution No. 82: 2001. Assumptions Supporting wall It is assumed that the construction of the wall, which supports the proposed doorsets, will have been the subject of a separate test and the performance of the wall is such that it will not influence the performance of the doorset for the required period. Clearance gaps Doorsets Installation Door leaf to frame clearance gaps can have a significant effect on the overall fire performance of a doorset. It is therefore assumed that the leaf to leaf and leaf to frame clearance gaps will not exceed those detailed for the tested doorsets in the reports referenced WF No s. 167957/A and 168809. In addition it is assumed that the door leaves will be in the closed position and will be latched (the inactive leaf of the double-leaf door option will incorporate engaged flush bolts). It is assumed that the doorsets will be identical to the doorsets tested under the reference WF No s. 167957/A and 168809, unless specified otherwise in this report. It is assumed that the proposed doorsets will be installed by competent installers, in a similar manner to the tested doorsets. Proposals Several tests have been conducted on composite doorset constructions which comprise Nan Ya door leaves fitted within Winkhaus Ecoframe 44 door frames (with frame extension) and incorporating Winkhaus AV2 Auto mechanical locking system. The doorsets were tested under the references WF No s. 167957/A and 168809.

Page 5 of 13 Basic Test Evidence WF No. 168809 It is proposed that the glazing systems as incorporated into the doors tested under the reference WF No. 168809 may be replaced with the Nan Ya glazing cassette system as tested under the reference Chilt/RF08171. The glazing will comprise double glazed units. The fire resisting glass component in this system may comprise either 7 mm thick Pyrobelite (as tested) or alternatively 6 mm Pyroshield glass. In each case the double-glazed unit will be orientated such that the Pyrobelite or Pyroshield is on the unexposed (non-fire risk side) of the doorset assembly. A test conducted to determine the fire resistance performance of a fully insulated single-acting, single-leaf doorset, when tested in accordance with BS 476: Part 22: 1987, Clause 6. For the purpose of the test the doorsets were referenced Doorset A and Doorset B. The doorsets were of overall dimensions 2077 mm high by 985 mm wide.both doorsets included a half glazed door leaf of 2013 mm high by 914 mm wide by 44 mm thick comprising a fibreglass skin with two panel details, composite rails, and a Phenolic Aldehyde foam core. The glazing system fitted to Doorset A consisted of a wired double glazed unit with 6.8 mm laminated glass with PVB interlayer on the exposed face and 6 mm Pyroshield S Clear on the unexposed face, the glazing system fitted to Doorset B consisted of a clear double glazed unit with 7 mm Pyrobelite EW30 on the exposed face and 6.8 mm laminated glass with PVB interlayer on the unexposed face. Each door leaf was hung within a Winkhaus Ecoframe on four stainless steel hinges and were fitted so that they opened towards the heating conditions of the test. The doorsets were each fitted with a Winkhaus AV2 Auto mechanical locking system which was latched for the duration of the test. Doorset A achieved an integrity performance of 45 minutes and Doorset B achieved an integrity performance of 38 minutes. Chilt/RF08171 A test conducted to determine the fire resistance performance of a fully insulated single-acting, single-leaf doorset, when tested in accordance with BS 476: Part 22: 1987, Clause 8. For the purpose of the test the doorsets were referenced Doorset A and Doorset B. Doorset A had leaf dimensions of 1915 mm high by 838 mm wide by 44 mm thick. Doorset B had leaf dimensions of 2012 mm high by 914 mm wide by 44 mm thick. Both doors were glazed using Nan Ya ABS glazing cassette systems. Doorset A achieved an integrity performance of 50 minutes and Doorset B achieved an integrity performance of 47 minutes.

Page 6 of 13 Assessed Performance General Doorset Performance Alternative Glazing Cassette The glazed and unglazed doorsets, as supplied by Phoenix Door Panels Limited, are of the same design as tested under the references WF No s. 167957/A and 168809 (apart from the glazing cassette design which will be discussed later in this report). The door designs, including the Ecoframe 44 component (with frame extension option) and the Winkhaus AV2 Automechanical lock, in glazed an unglazed configurations have both proven, by test, their ability to achieve significantly in excess of the required 30 minute fire resistance performance. The performance of the basic door leaf design with the various frame and ironmongery options is therefore not in doubt. The only area which is proposed to be modified relates to the design of the glazing cassette system which is incorporated into the glazed doorset option. This design modification therefore needs to be technically justified. It is proposed that the doorsets, as tested under the reference WF Report No. 168809, may be fitted with the Nan Ya glazing cassette system as tested under the referenced Chilt/RF08171 and as detailed in Fig. 1 below. Fig. 1 Glazing Cassette

Page 7 of 13 The glazing system comprises a Nan Ya ABS snap fit cassette system with interlocking beads. Four Nan Ya two part profiled galvanised steel glazing clips (0.9 mm thick) are utilised as the glass retention system (see Fig. 2 below): Fig. 2 Glazing Clip The proposed glazing system has been tested in doors identical to those supplied by Phoenix Door Panels Limited (test referenced Chilt/RF08171) and has shown to perform for periods of significantly in excess of 30 minutes when installed within such doors (47 and 50 minutes). The performance of the glazing systems (as tested with 7 mm Pyrobelite as the fire resisting glass element) installed within the doorset design considered in the report is therefore not in doubt and is positively assessed. Alternative Glass The glazing cassette systems installed within the doors tested under the reference Chilt/RF08171 incorporated Pyrobelite 7 mm as the fire resistance glass element in the double glazed unit. It is proposed that the Pyrobelite may be replaced with 6 mm Pyroshield glass whilst still maintaining the required fire resistance performance of the doorset. Although the Nan Ya glazing cassette has not been tested with the proposed Pyroshield glass option (which unlike the tested Pyrobelite is an uninsulating glass), this glass option was included within the double glazed units of the glazing cassette system tested under the reference WF Test Report No. 168809. The uninsulated glazed vision panel did not exhibit any loss of impermeability (integrity) throughout the test duration of 45 minutes. Although the design of the glazing cassettes are different, the materials from which the plastics components of the two tested designs of glazing cassette are fabricated are similar (ABS) and so the potential for ignition of the glass framing components of the proposed Nan Ya cassette is not considered to be any greater than the system tested in WF 168809 with the Pyroshield glass option.

Page 8 of 13 The performances achieved by the Nan Ya cassette system and the cassette system tested in WF 168809, which incorporated the uninsulating Pyroshield based double glazed unit, both achieved significantly in excess of the required 30 minutes (both doorsets/systems achieved in excess of 45 minutes fire resistance). This large degree of overrun provides further confidence in the proposal. The use of the Nan Ya glazing cassette system (as tested in Chilt/RF08171) is therefore positively appraised for use in the doorsets tested under the reference WF 168809 when incorporating either 7 mm Pyrobelite or Pyroshield as the fire resisting glass component in a double glazed unit. Conclusions Glazed and unglazed doorsets as supplied by Phoenix Door Panels Limited and as described in this report, would be expected to provide 30 minutes integrity performance, if subjected to a test in accordance with BS 476: Part 22: 1987. Validity This assessment is issued on the basis of test data and information available at the time of issue. If contradictory evidence becomes available to Bodycote warringtonfire the assessment will be unconditionally withdrawn and Phoenix Door Panels Limited will be notified in writing. Similarly the assessment is invalidated if the assessed construction is subsequently tested because actual test data is deemed to take precedence over an expressed opinion. The assessment is valid initially for a period of five years i.e. until 1 st October 2014, after which time it is recommended that it be returned for reappraisal. The appraisal is only valid provided that no other modifications are made to the tested construction other than those described in this report.

Page 9 of 13 Summary of Primary Supporting Data WF No. 168809 A test conducted to determine the fire resistance performance of a fully insulated single-acting, single-leaf doorset, when tested in accordance with BS 476: Part 22: 1987, Clause 6. For the purpose of the test the doorsets were referenced Doorset A and Doorset B. The doorsets were of overall dimensions 2077 mm high by 985 mm wide.both doorsets included a half glazed door leaf of 2013 mm high by 914 mm wide by 44 mm thick comprising a fibreglass skin with two panel details, composite rails, and a Phenolic Aldehyde foam core. The glazing system fitted to Doorset A consisted of a wired double glazed unit with 6.8 mm laminated glass with PVB interlayer on the exposed face and 6 mm Pyroshield S Clear on the unexposed face, the glazing system fitted to Doorset B consisted of a clear double glazed unit with 7 mm Pyrobelite EW30 on the exposed face and 6.8 mm laminated glass with PVB interlayer on the unexposed face. Each door leaf was hung within a Winkhaus Ecoframe on four stainless steel hinges and were fitted so that they opened towards the heating conditions of the test. The doorsets were each fitted with a Winkhaus AV2 Auto mechanical locking system which was latched for the duration of the test. The results of the test were as follows: Integrity Doorset A Doorset B 45 minutes 38 minutes The test was discontinued after a period of 45 minutes. Test Date : 26th November 2007 Sponsor : The sponsor of this test has provided written permission to allow the use of this data in the formulation of this assessment report

Page 10 of 13 WF No. 167957/A A test conducted to determine the fire resistance performance of a fully insulated single-acting, single-leaf doorset, when tested in accordance with BS 476: Part 22: 1987, Clause 6. For the purposes of the test the solid panel doorset was referenced Doorset A. Another half glazed specimen referenced Doorset B was tested simultaneously and is the subject of a separate letter report referenced WF Test Report No. 167957/B. Doorset A was of overall dimensions 2077 mm high by 985 mm wide including an outer frame extension profile screw fixed to both vertical edges of the frame and the upper horizontal edge of the frame. The doorset included a door leaf of 2013 mm high by 914 mm wide by 44 mm thick comprising fibreglass skin with six panel details, composite rails, and a Phenolic Aldehyde foam core. The door leaf incorporated a letter box fitted centrally on the midrail and an Eye viewer fitted at mid-span just below three quarter height The leaf was hung within a Winkhaus Ecoframe on four stainless steel hinges and was fitted so that it opened towards the heating conditions of the test. The doorset was fitted with a Winkhaus AV2 Auto mechanical locking system which was latched for the duration of the test. The results of the test were as follows: Integrity Insulation Doorset A 39 minutes 24 minutes The test was discontinued after a period of 42 minutes. Test Date : 6th November 2007 Sponsor : The sponsor of this test has provided written permission to allow the use of this data in the formulation of this assessment report

Page 11 of 13 Chilt/RF08171 A test conducted to determine the fire resistance performance of a fully insulated single-acting, single-leaf doorset, when tested in accordance with BS 476: Part 22: 1987, Clause 8. For the purpose of the test the doorsets were referenced Doorset A and Doorset B. Doorset A had leaf dimensions of 1915 mm high by 838 mm wide by 44 mm thick. Doorset B had leaf dimensions of 2012 mm high by 914 mm wide by 44 mm thick. Both doors were glazed using Nan Ya ABS glazing cassette systems. The results of the test were as follows: Integrity Doorset A Doorset B 50 minutes 47 minutes Test Date : 18th December 2008 Sponsor : The sponsor of this test has provided written permission to allow the use of this data in the formulation of this assessment report

Page 12 of 13 Declaration by Phoenix Door Panels Limited We the undersigned confirm that we have read and complied with the obligations placed on us by the UK Fire Test Study Group Resolution No. 82: 2001. We confirm that the component or element of structure, which is the subject of this assessment, has not to our knowledge been subjected to a fire test to the Standard against which the assessment is being made. We agree to withdraw this assessment from circulation should the component or element of structure be the subject of a fire test to the Standard against which this assessment is being made. We are not aware of any information that could adversely affect the conclusions of this assessment. If we subsequently become aware of any such information we agree to cease using the assessment and ask Bodycote warringtonfire to withdraw the assessment. Signed: For and on behalf of:

Page 13 of 13 Signatories Responsible Officer A. Kearns* - Technical Manager Approved D. Hankinson* - Senior Certification Engineer * For and on behalf of Bodycote warringtonfire. Report Issued: 1 st October 2009 The assessment report is not valid unless it incorporates the declaration duly signed by the applicant. This copy has been produced from a.pdf format electronic file that has been provided by Bodycote warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Bodycote warringtonfire. The original signed paper version of this report is the sole authentic version. Only original paper versions of this report bear authentic signatures of the responsible Bodycote warringtonfire staff.

Bodycote warringtonfire Head Office Holmesfield Road Warrington Cheshire WA1 2DS United Kingdom Tel: +44 (0) 1925 655 116 Fax: +44 (0) 1925 655 419 Email: Info@warringtonfire.net Website: www.warringtonfire.net