Oil, gas and dual fuel burners. Burner series

Similar documents
Oil, Gas and Dual Fuel Burners

Oil, Gas and Dual Fuel Monoblock Burners

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

Doing more for clean environment and energy saving

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/M SERIES. Modulating Gas Burners FIRING RATES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

Power Plant and Process Burners

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

ONE STAGE GAS BURNERS RDBS SERIES

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

PRESS P/N - P/N ECO SERIES

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Oil - kerosene burner

NEXTRON MONOBLOCK BURNERS kw

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

info NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners

Gas burners EK EVO 6 EK EVO 7

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

Kerosene - oil burner

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

Light oil - kerosene burner

RS Series Two Stage Progressive Gas Burners

LP BURNER SERIES.

Dual fuel burner NEXTRON 6 NEXTRON 7 NEXTRON 8 NEXTRON 9

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Alfa Laval three-screw pump

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

CODE MODEL TYPE PRESS GW 605 T80

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

FUEL OIL BURNERS. By Mark Butterfield March 09

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners

TWO STAGE PROGRESSIVE GAS BURNERS

VALUPAK. Packaged gas burners

Quality, Safety and Environment

1470 SERIES HOT AIR GAS BURNER

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

TWO STAGE GAS BURNERS

available in battery up to 4 units for a total of 560 kw

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Installation- and maintenance instruction BENTOFLEX ST 108 PL

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Solenoid actuator MB 7 and butterfly valves BVHM

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET

4 Specification Magneta Smedegaard twin pumps

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

CATALOGUE A complete range of burners for all fuels MONOBLOCK kw DUOBLOCK kw

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

product WM 10 for gas, oil, and dual-fuel WM 10 monarch burners ( kw) versatile performance Information on gas, oil, and dual-fuel burners

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB

3 Specification Magneta Smedegaard

MULTIFIRE. High temperature dual fuel burner

Design and Application Details

DRY TYPE TRANSFORMERS

LVDT/HC PILOT BURNER. External raw gas pilot burner

1070 SERIES ULTRA LOW NO X

GAS BURNERS BLU 3000 PR BLU 4000 PR

Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners

Installation- and maintenance instruction BENTOFLEX ST120KAV

IMMERSION FIRED HOT WATER BOILER

RAYPAK ILLUSTRATED PARTS LIST

Eclipse Vortometric Burners Series HI

GEMÜ 539 esydrive Motorized globe valve

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer

Sensors and Systems for Combustion Engineering

Transcription:

Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1

2

Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back pressure graphs 7 Gas burners 8 Dimensions and PI diagram 8 Technical data 9 Capacity/back pressure graphs 9 Dual fuel burners, light fuel oil/gas 10 Dimensions and PI diagram 10 Technical data 11 Capacity/back pressure graphs 11 Scope of delivery 12 Gas valve selection table 13 Gas elbow 13 Masonry figure 13 Flame dimensions 13 WiseDrive 14 3

Oilon burner Automatic control is integrated in the burner Easy to install Low-NOx (80 mg/nm 3 ) combustion head is also available Graphical user interface Low noise level < 80 db(а) CFD modelling allows a steady flow of air to the combustion head 4

Oil, gas and dual fuel burners Burners series Stream 350...450 Oilon s oil, gas and dual fuel burners are fully automatic, safe and reliable. The burners have been designed and manufactured with good economy, safety, easy maintenance and environmental friendliness in mind. Our gas burners comply with the EN 676 standard, oil burners with the EN 230 and EN 267 standards, and dual fuel burners with all of these. All burners are EU type tested. We also supply burners complying with various marine classification society requirements, such as ABS, BV, CCS, DNV, GL, KR, LR, NKK, RINA and RS.The burner materials and Oilon s long experience combined with considerable investments in product development guarantee the reliability of burners Construction The steel plate housing incorporates a three-phase motor that runs the fan located in the housing. The oil pump has its own three-phase motor. The surface of the housing is finished with durable high-gloss paint. The detachable burner cover allows the nozzle and ignition electrodes to be serviced without removing the burner. The stainless steel alloy combustion head and the diffuser disc can withstand temperatures up to 1,200 C. The combustion head is adjustable, to optimize the mixing of fuel regardless of the firing rate. The burner houses a sight glass for flame observation. The air damper assembly and fuel control valves each have their own stepper motor actuators. Controlled by the burner logic, the actuator motors closely control the air and fuel quantities depending on the required capacity. Suitable applications and installation The burners are suitable for warm and hot water boilers, steam boilers, hot air generators, and various types of process heating. They are also designed to suit furnaces with high back pressure. The burners can be mounted in horizontal, vertical and upwardfacing,or vertical and downward-facing orientation. The construction, materials and IP54 enclosure class of the burners are intended for indoor use, max. +50 C. The normal installation altitude is max. 500 m above sea level; other installation altitudes available by request. Fuels The following fuels can be used in the different burner models: KP models: - light fuel oil, viscosity 4-12 mm 2 /s, +20 C GP models: - natural gas, 2 nd family gases, groups H and E (equipment category I 2R ) GKP models: - (as above) natural gas/light fuel oil Burners using other fuels are available on request. With standard combustion head the NOx class is 1. With low NOx combustion head the NOx class is 3. Gas equipment Gas-related components of the gas and dual fuel burners comply the standard EN 676: two shut-off valves, pressure switches (min./ max.), and an automatic valve leak tester. Other piping related equipment is available upon request. Oil piping Mounted on the burner. Modulating burners have four solenoid valves. The oil regulator for the modulating burner is located on the nozzle return oil line. The oil filter is located on the suction side of the pump. Flame monitoring All models are equipped with automatic flame monitoring. In KP model, flame monitoring is taken care of via photocell/uv cell; in GKP model it is performed via UV cell. In GP model it is performed via ionization-based flame monitoring. Capacity regulation All models are of the modulating type. The burners are fitted with servomotors controlling the fuel and combustion air flows. The servomotors are controlled by a combustion manager integrated into the burners. A modulating burner can operate throughout the entire power range depending on the load. The burners are controlled on the basis of flue gas analysis. Burner automation Burner operation is controlled by a WiseDrive control system integrated into the burner (WD32, WD33 or WD34). All phases of operation take place automatically, controlled by the control program. In the event of a burner failure, the system automatically shuts down the burner. The capacity control module is located in the control unit under the burner cover. The operating panel and switches are located at the rear of the burner. WD32 for single fuel operation, two servomotors options: VSD control, O 2 control, CO control, intermittent operation WD33 (EU) for single fuel operation, three servomotors options: VSD control, O 2 control, CO control, continuous operation WD34 for dual fuel operation, DFM300 module, three servomotors options: VSD control, O 2 control, CO control, continuous operation Main benefits of WiseDrive burners: - integrated automatic control for easy installation - accurate electronic combustion mixture control ensures optimal combustion efficiency - operating phases displayed by symbols on the operating panel - diverse field bus connections - easy to use and service. Other benefits: - silent operation <80 db(a) - suitable for all boiler counter pressures - steady combustion - suitable for many applications. We reserve the right to make technical alterations. 5

Light fuel oil burners L1 L2 B4 H5 H3 H1 H2 H4 D1 L4 B2 D042694 B1 M B3 D2 L3 BURNER L1 L2 L3 L4 H1 H2 H3 H4 H5 B1 B2 B3 B4 D1 D2 M KP-350 M 1360 350 326 335 695 280 355 110 400 480 580 490 400 320 380 4xM20 KP-450 M 1470 350 342 355 770 304 395 125 465 500 650 550 465 370 440 4xM20 PI diagram 1. Oil filter 2. Oil pump 3. Electric motor 4. Pressure gauge 5. Solenoid valve 1, NC 6. Solenoid valve 2, NC 7. Pressure gauge 8. Oil regulator 9. Pressure switch 10. Solenoid valve 1, NC 11. Solenoid valve 2, NC 12. Air damper 13. Servomotor 14. Combustion air fan 15. Electric motor 16. Differential air pressure switch 17. Flame detector 6

Technical data BURNER KP-350 M KP-450 M Capacity kg/h kw 135-360 1600-4250 185-460 2200-5500 Fan motor 3~ 400 V 50 Hz Output kw Current A Speed r/min 7,5 13,4 2920 11,0 19,4 2940 Oil hose connection - suction - return R1 R1 R1 R1 Oil pump - Motor 3~ 400 V 50 Hz Output kw Current A Speed r/min TA4 1,5 3,1 2900 TA4 1,5 3,1 2900 Weight kg 340 470 Light fuel oil 1kg/h = 11.86kW 1kW = 860 kcal/h Ratio level Light fuel oil 1:2,5 (100 40%) Note! Weight varies according to delivery. Capacity/backpressure graph Capacity/backpressure graph KP-350 M mbar Capacity-back pressure Graph_KP-350 22 20 18 16 14 12 10 8 6 4 2 1 2 3 4 5 MW Capacity/backpressure graph KP-450 M mbar Capacity-back pressure Graph_KP-450 22 20 18 16 14 12 10 8 6 4 2 1 2 3 4 5 MW 7

Gas burners L1 L2 B4 H5 H1 H2 H4 D1 L4 H3 B2 D042690 B1 M B3 D2 L3 BURNER L1 L2 L3 L4 H1 H2 H3 H4 H5 B1 B2 B3 B4 D1 D2 M GP-350 M 1360 350 326 203 695 280 355 110 400 480 580 490 400 320 380 4xM20 GP-450 M 1470 350 342 193 770 304 395 125 465 500 650 550 465 370 440 4xM20 PI diagram 1. Ball valve, blow-off 2. Double solenoid valve 2.1 Solenoid valve 2.2 Pressure regulator 2.3 Solenoid valve 3. Pressure switch 4. Gas butterfly valve 5. Servomotor 6. Pressure switch, max. 7. Solenoid valve, ignition gas, *) option 8. Air damper 9. Servomotor 10. Combustion air fan 11. Electric motor 12. Differential air pressure switch 13. Flame detector 8

Technical data BURNER GP-350 M GP-450 M Capacity kw 700-4250 850-5500 Fan motor 3~ 400 V 50 Hz Output kw Current A Speed r/min 7,5 13,4 2920 11,0 19,4 2940 Weight kg 320 450 Ratio level Gas 1:6 (100 16,6%) Note! Weight varies according to delivery. Capacity/backpressure graphs Capacity/backpressure graph GP-350 M mbar Capacity-back pressure Graph_GP-350 22 20 18 16 14 12 10 8 6 4 2 1 2 3 4 5 MW Natural gas: gases of 2 nd family, groups H and E (equipment category l 2R ) Capacity/backpressure graph GP-450 M mbar Capacity-back pressure Graph_GP-450 22 20 18 16 14 12 10 8 6 4 2 1 2 3 4 5 MW 9

Dual fuel burner, light fuel oil/gas L1 L2 B4 H5 H1 H2 H4 D1 L4 H3 L5 B2 D042664 B1 M B3 D2 L3 BURNER BURNERL1 L1L2 L2L3 L3L4 L4 L5 L5 H1 H1 H2 H2 H3 H3 H4 H4 H5 B1 B2 B3 B3 B4 B4 D1 D1 D2 D2 M M GKP-350 M 1360 350 326 203 335 695 280 355 110 400 480 580 490 400 320 380 4xM20 GKP-450 M 1470 350 342 193 355 770 304 395 125 465 500 650 550 465 370 440 4xM20 Oil PI diagrams Gas 1. Oil filter 2. Oil pump 3. Electric motor 4. Pressure gauge 5. Solenoid valve 1, NC 6. Solenoid valve 2, NC 7. Pressure gauge 8. Oil regulator 9. Pressure gauge 10. Solenoid valve1, NC 11. Solenoid valve 2, NC 12. Air damper 13. Servomotor 14. Combustion air fan 15. Electric motor 16. Differential-air pressure switch 17. Flame detector 1. Ball valve, blow-off 2. Double solenoid valve 2.1 Solenoid valve 2.2 Pressure regulator 2.3 Solenoid valve 3. Pressure switch 4. Gas butterfly valve 5. Servomotor 6. Pressure switch, max. 7. Solenoid valve, ignition gas, *) option 8. Air damper 9. Servomotor 10. Combustion air fan 11. Electric motor 12. Differential air pressure switch 13. Flame detector 10

Technical data BURNER GKP-350 M GKP-450 M Capacity oil, kg/h oil, kw gas, kw 135-360 1600-4250 700-4250 185-460 2200-5500 850-5500 Fan motor 3~ 400 V 50 Hz Output kw Current A Speed r/min Oil hose connection - suction - return Oil pump - Motor 3~ 400 V 50 Hz Output kw Current A Speed r/min 7,5 13,4 2920 R1 R1 TA4 11,0 19,4 2940 R1 R1 TA4 1,5 3,1 2900 1,5 3,1 2900 Weight kg 390 505 Light fuel oil 1kg/h = 11.86kW 1kW = 860 kcal/h Ratio level Light fuel oil 1:2,5 (100 40%) Gas 1:6 (100 16,6%) Note! Weight varies according to delivery. Capacity/backpressure graphs Capacity/backpressure graph GKP-350 M mbar Capacity-back pressure Graph_GKP-350 22 20 18 16 14 12 10 8 6 4 2 1 2 3 4 5 MW mbar 22 20 18 16 14 12 10 8 6 4 2 Capacity/backpressure graph GKP-450 M Capacity-back pressure Graph_GKP-450 Natural gas: gases of 2 nd family, groups H and E (equipment category l 2R ) Light fuel oil: 1 kg/h = 11,86 kw 1 2 3 4 5 MW 11

Scope of delivery The burners are delivered with the following equipment: KP-350 M,-450 M GP-350 M,-450 M GKP-350 M,-450 M Burner flange gasket Oil nozzle(s) Solenoid valves for oil Oil pump with pressure regulator valve Separate oil pump motor Non-return valve Oil pressure gauge(s) Return oil pressure switch Air and gas evacuator Oil hoses, 2 pcs, length 3,000 mm Oil filter Pressure gauge for monitoring the oil inlet pressure o o Pressure switch for monitoring the oil inlet pressure o o WiseDrive (electronic mixture control) for regulating the air-oil-gas ratio, including: - quantity control valve for oil - quantity control valve for gas - servomotor for air dampers - servomotor for FGR o o o Gas nozzle Pressure gauge for measuring the pressure at the gas nozzle o o Max. pressure switch for gas Air pressure differential switch Ignition transformer Ignition cables and electrodes Flame detector Built-in combustion air blower with a direct-drive electric motor Air dampers Pressure gauge for measuring the fan pressure o o o Angle joint 90 Twin solenoid valve for gas, including: - min. pressure switch for gas - two gas valves - automatic leak control - ball valve blowout (separate) Ignition gas valve o o Burner operating and maintenance manual o standard delivery o optional 12

Gas valve selection table BURNER GAS VALVE BURNER MAX. CAPACITY kw*) SIZE DN GAS INLET PRESSURE mbar TYPE **) 20 30 50 100 150 GP/GKP-350 M 50 DMV-D 1700 2200 3100 3800 65 DMV 2000 2500 3300 4400 4400 80 DMV 2800 3400 4400 4400 4400 100 DMV 3300 4100 4400 4400 4400 125 DMV 3800 4400 4400 4400 4400 GP/GKP-450 M 50 DMV-D 2200 3200 3900 65 DMV 2600 3300 4700 5500 80 DMV 3000 3700 4800 5500 5500 100 DMV 3800 4600 5500 5500 5500 125 DMV 4700 5500 5500 5500 5500 NOTE! If the gas inlet pressure is less than 30 mbar or if the gas used is not among those mentioned, evalution must be made case-specifically. *) The max. capacities shown by the table are achieved when the boiler back pressure is 0 0. Natural gas1 m 3 n/h 10 kw **) Or corresponding type Gas inlet pressure (Pmax) at burner - max. 500 mbar when using DMV(D) valve. Gas elbow GAS ELBOW DIMENSIONS WITH DIFFERENT VALVES DN50 DN65 DN80 DN100 DN125 H L L L L L GP/GKP-350 M 495 735 860 880 920 970 GP/GKP-450 M 515 735 860 880 920 970 Other dimensions available on special request. Masonry figure Flame dimensions 2 1 60...90 ØD1 ØD2 3 4 L2 1 Gasket 2 Mounting plate 3 Ceramic wool or equivalent 4 Masonry ØD1, ØD2, L2 See burner dimension diagram 13

WiseDrive burner automation Electronic fuel-air mixture control achieves lower flue gas emissions, lower energy consumption and more accurate control of the technical parameters of the burner. WD32 34 is intended for oil, gas and duel fuel burners in the 1 8 MW range. Automation is integrated into the burner. The system is of modular construction. The standard scope of delivery includes combustion manager and power control modules. Optional modules are available for optimising the combustion process and for remote control. Features of the WD32-34 system: complies with EN 12067 suitable for continuous and intermittent operation accurate mixture setting and result disturbance diagnostics diverse field bus connections basic parameters and back-up copies using a computer diagnostics and adjustment of set values by remote operation. WiseDrive (WD), electronic fuel-air mixture control energy-efficient and environmentally friendly solution PROFIBUS, Modbus, Ethernet Fieldbus interface Control system Remote control LAMTEC SYSTEM BUS (LSB) O 2 measurement Optional LT2 LS2 Optional LT2 LS2-K LS2 (O 2 ) KS1 (CO 2 ) CO detection Optional LT2 KS1 Optional LT2 KS1-K Boiler pressure/temperature Flame sensor Load control module LCM100 Operating panel UI300 BT300 Air Variable speed1802 module VSM100 Boiler Gas DFM300 Dual fuel module Oil 14

15

EN4B/3.00/052015 Oilon invests in product development and research. A modern product development centre meeting all European standards enables us to perform a wide range of burning tests and accurate oil and gas measurements. We supply burners for ships according to classification societies, such as ABS,BV, CCS, DNV, GL, KR, LR, NKK, RINA,and RS classifications. We participate in trade shows around the world every year. We have a comprehensive maintenance network, and our worldwide operations ensure rapid availability of maintenance and spare parts. The continuous training of our personnel and representatives guarantees high-quality maintenance operations. INDUSTRY OILON INDUSTRY OY Metsä-Pietilänkatu 1 PL 5 15801 Lahti Puh. (03) 85 761 Fax (03) 857 6239 info@oilon.com www.oilon.com 16