CONTINUOUS IMMERSION AND DUST TEST REPORT

Similar documents
THERMAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION TEST REPORT

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

Center for Quality Engineering. Test Report No.: E0G90005

MEASUREMENT AND TEST REPORT

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

CERTIFICATE of QUALITY TEST

Summary of HALT, IPx7 & IP69K testing for AT Series connectors

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EUMOS SYMPOSIUM 2017

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

PRODUCT SPECIFICATION

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

VITLAB Dispenser. Standard Operating Procedure (SOP)

Product Data Sheet DV5214 NU

Heating chamber with mechanical convection

ENVIRONMENTAL TESTING

1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

Heating chamber with mechanical convection

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

Safety drying ovens. Advantages: Areas of application: FDL series 115

ASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc.

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

August 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Product Data Sheet 632 NU-006

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

SmartSensor 105 & Advance NEMA Salt Fog

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Heating chamber with mechanical convection

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Safety drying oven with expended temperature range

Selecting Weights and Certificates

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

Product Data Sheet 624 NR. The engineer's choice

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Heating chamber with mechanical convection

Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac

Certificate of Calibration

600 Amp Surge Arrester

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.

NATIONAL TECHNICAL SYSTEMS

Heating oven with mechanical convection

United States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018

Product Data Sheet 4118 N/ The engineer's choice

Our test laboratory - Apparatebau Kirchheim-Teck GmbH

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

High Accuracy Bunker Blending / Bunker Control

Product Data Sheet 4184 N/17X. The engineer's choice

JJG Translated English of Chinese Standard: JJG

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTONEUM NORTH AMERICA, INC Haggerty Rd. Novi, MI Jian Pan Phone: MECHANICAL

High Accuracy Bunker Blending / Bunker Control

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

Flash Point Process Analyzer

l-tech C O M P A N Y Issue by Engineering Department Product 8.4"Rugged LCD : Model WRD0840 Product Description Test Reason

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Heating oven with natural convection

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SGS TEST REPORT. Page: 1 of 8 Date: April 15,2010. itech Company LLC Christy Street, Fremont CA USA

SPECIFICATION 宏致電子股份有限公司 桃園縣中壢市東園路 13 號. No.13, Dongyuan Rd., Jhongli City, Taoyuan County 320, Taiwan (R.O.C.)

Chemical indicators and test devices Benchmarking sterilisation processes.

Report Test Report

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

Safety drying ovens with expanded temperature range

Shawal CGC Calibration Profile

Product Change Notice

Customer Information. Service Engineer s Responsibilities. Agilent Cary 7000 UMS/UMA/Solids Autosampler

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE PRESSURE

Product Data Sheet 3214 JH3-195

EBI 12 The new data logger generation

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Product Data Sheet 8412 N/ The engineer's choice

HULANE GROUP. Auto World, We Connect. A Professional Connectors Manufacturer. HL Auto Parts. = High Level Auto Parts 2017/05/16 1

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

CLIMATE. Climate and temperature chambers.

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Heating oven with mechanical control

WESTONE ONYX BLACK WEI-408B2

Jun06 Rev D

Reliability Test Report

TYPE APPROVAL CERTIFICATE

Transferpette. Testing Instructions (SOP) 1. Introduction. October 2013

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

Transcription:

Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei City 23586, Taiwan (R.O.C.) Sample Name :TK SERIES Date Received :APR 02, 2014 Date Tested :APR 02, 2014 ~ APR 03, 2014 TESTING LABORATORY IS ACCREDITED BY: IEC/IECQ 17025 certificate of independent test laboratory approval Certificate No.:1.72.0031 ISO 17025 accredited in respect of laboratory is approved by TAF Certificate No.:L0835-120910 ISO 9001 certificate is approved by TUV CERT certification body of TUV NORD Cert GmbH WE HEREBY CERTIFY THAT: The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them. Name Signature Date Test Engineer Gin Lu Apr 09, 2014 Manager Longson Lin Apr 09, 2014 NOTE: 1. This report will be invalid if reproduced in part or altered in any way. 2. This report refers only to the specimen(s) submitted to test, and is invalid if used otherwise. 3. This report is ONLY valid with the examination seal and signature of this institute. 4. The tested specimen(s) will only be preserved for thirty days from the date issued, if not collected by the applicant.

Reliability & Failure Analysis Engineering Group Page 1 of 12 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT... 2 1.2 UNIT OPERATING CONDITION... 2 2. CONTINUOUS IMMERSION TEST 2.1 TEST EQUIPMENT... 3 2.2 LABORATORY AMBIENCE CONDITION... 3 2.3 REFERENCE DOCUMENT... 3 2.4 TEST CONDITION... 3 2.5 SUMMARY OF TEST... 3 3. DUST TEST 3.1 TEST EQUIPMENT... 4 3.2 LABORATORY AMBIENCE CONDITION... 4 3.3 REFERENCE DOCUMENT... 4 3.4 TEST CONDITION... 4 3.5 SUMMARY OF TEST... 4 ATTACHMENTS... 5

Reliability & Failure Analysis Engineering Group Page 2 of 12 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT Manufacturer:Taiway Electronics Components Co. Sample name:tk SERIES Test item, Unit number and Sample quantity:(total of 6 units) Test item Unit number Sample quantity Continuous immersion test Unit no.1 to no.6 6 units Dust test Unit no.5 and no.6 2 units 1.2 UNIT OPERATING CONDITION None

Reliability & Failure Analysis Engineering Group Page 3 of 12 2. CONTINUOUS IMMERSION TEST 2.1 TEST EQUIPMENT Model Calibration Date ETL-L180 Water Leakage Test Chamber NCR 2.2 LABORATORY AMBIENCE CONDITION Temperature:25 C ± 5 C Relative humidity:65 % ± 5 % (RH) 2.3 REFERENCE DOCUMENT This test is based on IEC/EN 60529 IPX8 (2013) continuous immersion Test Protected. 2.4 TEST CONDITION Units are non-operating. The water temperature is +25 C The lowest point of unit is locating 1000 mm below surface of the water. The duration of test is 60 minutes. 2.5 SUMMARY OF TEST Before and after testing, units function was normal. No permeating water the inner unit inspection will be performed by customer.

Reliability & Failure Analysis Engineering Group Page 4 of 12 3. DUST TEST 3.1 TEST EQUIPMENT Model Serial Number Calibration Date Vötsch- VDT 1000A 59566059640010 DEC 13, 2013 3.2 LABORATORY AMBIENCE CONDITION Temperature:25 C ± 5 C Relative humidity:65 % ± 5 % (RH) 3.3 REFERENCE DOCUMENT The test is based on IEC/EN 60529 IP6X (2013) Dust Test Protected. 3.4 TEST CONDITION Units are non-operating. Dust material:talcum powder (100% dry fine) Particle size Amount (%) < 5 μm (Diameter) 42.31% ± 5 5~10 μm (Diameter) 35.85% ± 5 10~20 μm (Diameter) 21.15% ± 5 20~40 μm (Diameter) 0.69% ± 5 > 40 μm (Diameter) 0% Amount of talcum power:2 kg/m 3 (chamber volume) Dust density:2.03 g/cm 3 Depression level:10 mbar Air direction:vertically to achieve slowest possible downward settlement Duration of exposure:8 hours 3.5 SUMMARY OF TEST Before and after testing, units function was normal. No permeating dust the inner unit inspection will be performed by customer.

Reliability & Failure Analysis Engineering Group Page 5 of 12 Attachment 1:Photo of unit before all tests Function was normal Unit no.1 Unit no.2 Unit no.3

Reliability & Failure Analysis Engineering Group Page 6 of 12 Function was normal Unit no.4 Unit no.5 Unit no.6

Reliability & Failure Analysis Engineering Group Page 7 of 12 Attachment 2:Photo of continuous immersion test setup

Reliability & Failure Analysis Engineering Group Page 8 of 12 Attachment 3:Photo of dust test setup Unit no.5 Before testing Depression level After testing

Reliability & Failure Analysis Engineering Group Page 9 of 12 Unit no.6 Before testing Depression level After testing

Reliability & Failure Analysis Engineering Group Page 10 of 12 Attachment 4:Photo of unit after continuous immersion test Function was normal Unit no.1 Unit no.2 Unit no.3

Reliability & Failure Analysis Engineering Group Page 11 of 12 Function was normal Unit no.4 Unit no.5 Unit no.6

Reliability & Failure Analysis Engineering Group Page 12 of 12 Attachment 5:Photo of unit after dust test Function was normal Unit no.5 Unit no.6 << The Following Blank >>