Safety switches for hinges

Similar documents
Safety switches with separate actuator

Safety switches with separate actuator

Safety rope switch without reset for simple stop

Safety rope switches with reset for emergency stop

Safety rope switch with reset for emergency stop

FL series position switches

Safety switches for hinged doors

Safety switches for hinged doors

LR-LX-LK-LW Safety Switches with separate actuator

Safety switches with solenoid and separate actuator

Position switches FR series

Switches with manual reset

Position switches FD series

Safety switches with solenoid and separate actuator

Position switches FR series

Single foot switches - PX and PA series

LK Position Switches TECHNICAL DATASHEET.

Position switches FC series

Microswitches MK series

SFS-UFS Single Foot Switches

Single foot switches PX and PA series

Prewired position switches FF series

Rope safety switches with reset for emergency stop

Microswitches M series

Safety Limit Switches

Prewired position switches FF series

Safety switches with solenoid and separate actuator

Microswitches MK series

Single foot switches PX and PA series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

Microswitches MK Series

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Key selector switches

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

EA series housings. Selection diagram. 125 General Catalogue HMI ACTUATORS ACCESSORIES COVERS. emergency button Ø 40 push-pull, windowed

Limit Switches - Limit Type Plastic Body IP65

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Miniaturized limit switches

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety switches with solenoid and separate actuator

Position Switches Series 8070/2

Manual Reset Limit Switch

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

FOOT SWITCHES

Safety switches with solenoid and separate actuator

Position Switches Series 8074/2

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

ES series enclosures. Selection diagram ES ES hole, Ø 22 mm 1 hole, Ø 22 mm ES grey cover. 2 holes, Ø 22 mm ES

Limit Switch - Prewired Type Metal Body

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

BETA Switching Switches and Light Indicators

Safety switches with solenoid and separate actuator

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

AF40... AF96 3-pole contactors Technical data

Position Switches Series 8060/2

AZM 161SK 12/12RKED/TU 024

Solenoid Locking Safety Switches

Standard Interlock Safety Switches

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

General_technical_data Series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Installation and Operating Instructions

Automation - Lift - Handling System - Atex

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Standard Interlock Safety Switches

Hinged Safety Door Switch

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

MS General Information Extended Product Type: MS

XACA871 pendant control station XAC-A - 8 pushbuttons

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Technical data. Standards: IEC/EN BG-GS-ET-15

Safety Limit Switch

Limit switches 3. Page 92. Page 92

Installation and Operating Instructions

ASL09..S 3-pole Contactors - Spring Terminals

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

SG-B1 SERIES / SG-A1 SERIES

Pendant control stations 6

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

XACA871 pendant control station XAC-A - 8 pushbuttons

Transcription:

Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded conduit entry (standard) With cable gland With M12 plastic connector With M12 metal connector product option accessory sold separately 7

Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article FR 1896-XGL16M2K70T6 Housing FR FM FX FZ technopolymer, one conduit entry metal, one conduit entry technopolymer, two conduit entries metal, two conduit entries, snap action 6, 7,, make before break 9, 14,, shifted 18,, close 1NO+, 21 NC, 2NO+,, 4, 66, Contact type G G1 External metallic parts X zinc-plated steel (standard) stainless steel silver contacts (standard) silver contacts with 1 µm gold coating silver contacts, 2. µm gold coating (not for contact blocks, 21,,, 4) Ambient temperature T6 Pre-installed cable glands or connectors no cable gland or connector (standard) K2 cable gland for cables Ø 6 12 mm K70 M12 plastic connector, 4-pole For the complete list of possible combinations please contact our technical department. Threaded conduit entry M2 Mx1. (standard) M1 M16x1. (FR-FX housing only) PG 1. A PG 11 (FR-FX housing only) Actuator design actuator with hole (standard) L Ø8x69 mm, tapered Ø6.9 L6 Ø8x1 mm L9 Ø8x140 mm L16 Ø8.7x16 mm, stainless steel -2 C +80 C (standard) -40 C +80 C article FK 96-XGL16M1K24T6 Housing FK technopolymer, one conduit entry, 4, External metallic parts zinc-plated steel (standard) X stainless steel Contact type silver contacts (standard) G silver contacts with 1 µm gold coating Threaded conduit entry M1 Pre-installed cable glands no cable gland (standard) K24 cable gland for cables Ø 10 mm K28 cable gland for cables Ø 7 mm M16x1. (standard) PG11 Ambient temperature T6 Actuator design actuator with hole (standard) L Ø8x69 mm, tapered Ø6.9 L6 Ø8x1 mm L9 Ø8x140 mm L16 Ø8.7x16 mm, stainless steel -2 C +80 C (standard) -40 C +80 C 74

Safety switches for hinges Technical data Housing FR, FX and FK series housing made of glass fibre reinforced technopolymer, self-extinguishing, shock-proof and with double insulation: FM and FZ series: metal housing, baked powder coating. FR, FM series: one threaded conduit entry: Mx1. (standard) FK series: one threaded conduit entry: M16x1. (standard) FX series: two knock-out threaded conduit entries: Mx1. (standard) FZ series: two threaded conduit entries: Mx1. (standard) Protection degree: IP67 acc. to EN 6029 with cable gland of equal or higher protection degree Main features Metal housing or technopolymer housing, from one to two conduit entries Protection degree IP67 12 contact blocks available Versions with M12 connector Versions with gold-plated silver contacts Versions with stainless steel external metallic parts General data For safety applications up to: SIL acc. to EN 661 PL e acc. to EN ISO 1849 1 Mechanical interlock, not coded: type 1 acc. to EN ISO 14119 Safety parameters: B 10D :,000,00 for NC contacts Service life: years Ambient temperature: -2 C +80 C Max. actuation frequency: 600 operating cycles/hour Mechanical endurance: 1 million operating cycles Max. actuation speed: 180 /s Min. actuation speed: 2 /s Tightening torques for installation: see page 1 24 Cable cross section (flexible copper strands) s, 21,,, 4: min. 1 x 0.4 mm 2 (1 x AWG ) max. 2 x 1. mm 2 (2 x AWG 16) s, 6, 7, 9, 14, 18, 66: min. 1 x 0. mm 2 (1 x AWG ) max. 2 x 2. mm 2 (2 x AWG 14) Quality marks: IMQ approval: EG610 (FR-FX-FK series) EG609 (FM-FZ series) UL approval: E11787 CCC approval: 0701002001 (FR-FX-FK series) 0701009998 (FM-FZ series) EAC approval: RU C-IT.AД.В.0044 In compliance with standards: IEC 60947-1, EN 60947-1, EN 60947 1, IEC 604 1, EN 604 1, EN ISO 14119, EN ISO 12100, IEC 6029, EN 6029, UL 08, CSA.2 No.14. Approvals: IEC 60947-1, UL 08, CSA.2 No.14, GB14048. 01. Compliance with the requirements of: Machinery Directive 06/42/EC and EMC Directive 14/0/EU. Positive contact opening in conformity with standards: IEC 60947-1, EN 60947-1. If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements from page 1 to page 24. Electrical data Thermal current (I th 10 A 00 Vac 600 Vdc 400 Vac 00 Vdc (contact blocks, 21,,, 4) Rated impulse withstand voltage (U imp 6 kv 4 kv (contact blocks, 21,,, 4) Conditional short circuit current: 1000 A acc. to EN 60947 1 Protection against short circuits: type am fuse 10 A 00 V Pollution degree: without connector with M12 connector 4 and -pole Thermal current (I th 4 A 20 Vac 00 Vdc Protection against short circuits: type gg fuse 4 A 00 V Pollution degree: Utilization category Alternating current: AC1 (0 60 Hz) (V) 20 400 00 (A) 6 4 1 Direct current: DC1 (V) 24 12 20 (A) 6 1.1 0.4 Alternating current: AC1 (0 60 Hz) (V) 24 1 20 (A) 4 4 4 Direct current: DC1 (V) 24 12 20 (A) 4 1.1 0.4 with M12 connector 8-pole Thermal current (I th 2 A 0 Vac 6 Vdc Protection against short circuits: type gg fuse 2 A 00 V Pollution degree: Alternating current: AC1 (0 60 Hz) (V) 24 (A) 2 Direct current: DC1 (V) 24 (A) 2 7

Description These safety switches are designed to monitor gates or doors that safeguard dangerous parts of machines without inertia. They are very sensitive, open the contacts after few degrees of rotation and immediately send the stop signal. The head, which can be turned in 90 steps, enables installation in multiple positions. Available with technopolymer or metal housings, with protection degree IP67. The special design allows it to be used even under operating conditions in which dust and dirt could inhibit the operation of normal safety switches with separate actuator. Head with variable orientation For all switches, the head can be adjusted in 90 steps after removing the four fastening screws. This allows you to use the same switch on both right- and left-facing door fronts. Protection degree IP67 These devices are designed to be used in the toughest environmental conditions and they pass the IP67 immersion test acc. to EN 6029. They can therefore be used in all environments where maximum protection degree of the housing is required. Extended temperature range These devices are also available in a special version suitable for an ambient operating temperature range from -40ºC up to +80 C. They can therefore be used for applications in cold stores, sterilisers and other equipment with low temperature environments. The special materials used to produce these versions retain their characteristics even under these conditions, thereby expanding the installation possibilities. Application examples Adjustable switching point When installing the device, the contact switching point can be adjusted over the entire 60 range. By fixing the stud screw, it is possible to check the correct setting of the activation angle and quickly and easily adjust it if necessary. Once adjustment is complete, you can render the device tamper-proof against commonly used tools using the supplied lock pin. Features approved by IMQ 00 Vac 400 Vac (for contact blocks, 21,,, 4) Conventional free air thermal current 10 A (I th Protection against short circuits: type am fuse 10 A 00 V Rated impulse withstand voltage 6 kv (U imp 4 kv (for contact blocks, 21,,, 4) Protection degree of the housing: IP67 MV terminals (screw terminals) Pollution degree: Utilization category: AC1 Operating voltage ( 400 Vac (0 Hz) Operating current ( A Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X Positive opening contacts on contact blocks, 6, 7, 9, 14, 18,, 21,,, 4, 66. In compliance with standards: EN 60947 1, EN 60947 1+ A1:09, fundamental requirements of the Low Voltage Directive 14//EU. Please contact our technical department for the list of approved products. Features approved by UL Utilization categories Q00 (69 VA, 12 20 Vdc) A600 (7 VA, 1 600 Vac) Housing features type 1, 4X indoor use only, 12, 1 For all contact blocks use 60 or 7 C copper (Cu) conductor, rigid or flexible, wire size 12, 14 AWG. Tightening torque for terminal screws of 7.1 lb in (0.8 Nm). In compliance with standard: UL 08, CSA.2 No.14 Please contact our technical department for the list of approved products. 76

Safety switches for hinges Dimensional drawings All values in the drawings are in mm Contact type: Technopolymer housing Technopolymer housing Technopolymer housing R = snap action L = LO = make before break LS = shifted R 6 L 7 LO 9 L 14 LS 18 L L 21 L L L 4 L 66 L 84.7.2 11.2 1. FR 96-M2 FR 696-M2 FR 796-M2 FR 996-M2 FR 1496-M2 FR 1896-M2 FR 96-M2 FR 2196-M2 FR 96-M2 FR 96-M2 FR 496-M2 FR 6696-M2 0.8.2 8. 1 24 1NO+ NC 2NO+ 12.2 0.8. 11.1 6 11 4 FX 96-M2 FX 696-M2 FX 796-M2 FX 996-M2 FX 1496-M2 FX 1896-M2 FX 96-M2 FX 2196-M2 FX 96-M2 FX 96-M2 FX 496-M2 FX 6696-M2 40 42 8 24.1 1 8. 4 18. Ø.2 1.7 69.7.2 11.2 6. 0.8.2 8. 1 12.2 24 Actuating force 0.1 Nm (0.4 Nm ) 0.1 Nm (0.4 Nm ) 0.1 Nm (0.4 Nm ) Travel diagrams page 18 - group 9 page 18 - group 9 page 18 - group 9 1NO+ NC 2NO+ FK 96-M1 FK 496-M1 0.8 Contact type: Metal housing Metal housing R = snap action L = LO = make before break LS = shifted R 6 L 7 LO 9 L 14 LS 18 L L 21 L L L 4 L 66 L 87.6 4.4 11.2.2 FM 96-M2 FM 696-M2 FM 796-M2 FM 996-M2 FM 1496-M2 FM 1896-M2 FM 96-M2 FM 2196-M2 FM 96-M2 FM 96-M2 F96-M2 FM 6696-M2.2 1 24 8. 12.2 0.8 1. 1NO+ NC 2NO+ 78.2 44. 11.2.2 FZ 96-M2 FZ 696-M2 FZ 796-M2 FZ 996-M2 FZ 1496-M2 FZ 1896-M2 FZ 96-M2 FZ 2196-M2 FZ 96-M2 FZ 96-M2 FZ 496-M2 FZ 6696-M2 40 42 0 18..2 8. 12.2 1 24 Actuating force 0.1 Nm (0.4 Nm ) 0.1 Nm (0.4 Nm ) Travel diagrams page 18 - group 9 page 18 - group 9 1NO+ NC 2NO+ 1. Items with code on green background are stock items Accessories See page 299 The 2D and D files are available at www.pizzato.com 77

Dimensional drawings for actuators All values in the drawings are in mm Option Drawing L Ø 8 1 Ø 6.9 69 L6 1 Ø 8 Ø 8 L9 140 Ø 8.7 L19 16 Adjustment of the switching point Temporary locking of the actuator (stud screw provided). Verify the switching point according to EN ISO 187 and recalibrate if necessary. Pin the switch (pin is provided). 78