Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Similar documents
High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Technical Procedure for Gas Chromatography (GC-FID)

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Refinery and Natural Gas Analysis

Analysis of Petroleum Fractions by ASTM D2887

High Temperature Simulated Distillation. Terry Thompson. Intertek Testing Services St. Rose, Louisiana

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Using the PSD for Backflushing on the Agilent 8890 GC System

ANTEK APPLICATED Turn-Key GC solutions

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Application. Gas Chromatography June 1995

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

GC Method Compliance and Large Valve Oven Application

Beverage Grade Carbon Dioxide

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

White Paper.

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Crude Evaluation Best Practices

GC MERGE OF LIGHT ENDS WITH ASTM D7169 BOILING POINT DISTRIBUTION

Dr. Carl Rechsteiner, Research Scientist Chevron Corporation Dr. Brian Rohrback, President Infometrix, Inc. Chevron 2012

Application of High-Temperature Simulated Distillation to the Residuum Oil Supercritical Extraction Process in Petroleum Refining

Live Crude Oil Volatility

Application Note. Author. Introduction. Energy and Fuels

Monitor Chlorine in Crude at Sub-ppm Levels

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Agilent and ASTM. Update on Recent Activities. Page 1

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

AC Reformulyzer M3. 75 Minutes Full Gasoline Analysis. Compliance with ASTM D 6839, EN and ISO Self Explanatory Operation

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

Agilent Multimode Inlet for Gas Chromatography

On-Line NIR Analysis for Blending

On-Line NIR Analysis of Crude Distillation Unit

Live Crude Oil Volatility

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Instruments for the Analysis of Petroleum Products. Oxidation Stability

ADU 5. Automatic Distillation Unit

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

MUTINEER EXETER CRUDE OIL. Santos Limited

Correlating TBP to Simulated Distillations. COQA Long Beach, CA

B/R Vacuum Distillation ASTM D1160. Fully Automatic Vacuum Distillation According to D1160

ASTM D for Denatured Fuel Ethanol Automating Calculations and Reports with Empower 2 Software

Application Note. Authors. Abstract. Energy & Chemicals

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

S-PRO 3200 GC System for Sulfur Analysis

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

breakthrough versatility

On-Line Process Analyzers: Potential Uses and Applications

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Process Analyzer. Reid Vapor Pressure Analyzer Model P-700. Credible Solutions for the Oil and Gas Industry

Operation and Applications of Differential Flow Modulation

Technical Procedure for the Examination of Arson Evidence

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

ASTM D 6730 Detailed Hydrocarbon Analysis

Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

Application Note. Abstract. Authors. Environmental Analysis

NEW METHODOLOGY OF DETERMINATION OF BOILING POINT AT VERY LOW PRESSURE: PETROLEUM CASE

Choose for Your Instrument

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

CONSTITUTION OF COAL TAR PITCH AND ITS EFFECT ON PROPERTIES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

COOPER BASIN CRUDE OIL. Santos Limited

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

AZ Chrom s.r.o.

PETROLEUM SUBSTANCES

TSHR 6000 series TN/TS/TX analyzer

IROX 2000 IROX DIESEL

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Crude Assay, ASTM, TBP distillations, Evaluation of crude oil properties.

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Transcription:

Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com

Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to quickly and accurately determine the true boiling point distribution of crude oil and petroleum fractions by gas chromatography for over 40 years. From the very beginning, Separation Systems has been committed to working with ASTM and others to evolve, improve and advance the technique. And we remain committed to this important endeavor. All of our simulated distillation analyzers are guaranteed to deliver accurate results that meet or exceed all the requirements of the current and proposed standard test methods from ASTM and other international standard organizations. All of our analyzers are comprehensive in nature and include the following: Agilent 7890B GC Automatic liquid sampler/injector Inlet appropriate for the designated test method(s) including our industry preferred SimDis Inlet Column, flame ionization detector (FID) (and element and/or mass selective detector) Chromatography data acquisition system (if required) Industry leading SimDis Expert software 6 month supply of retention time standards, reference materials and consumable items (septa, inlet liners, ferrules) System configuration and testing at Separation Systems prior to shipment Installation & performance verification in the client s lab Training: GC hardware and GC data system, preventative maintenance procedures, how to recognize and fix problems, SimDis Expert software and test method(s) When we leave your lab, your system is ready to go. Our extensive knowledge of simulated distillation analysis coupled with the highly responsive support we provide throughout the lifetime of the system is why so many people count on us for their simulated distillation needs. We never take any of our clients for granted. We d be pleased to have the opportunity to do the same for you. Simulated Distillation Test Methods Summary Test Method Max Carbon # Sample Stream Type Initial (IBP) Boiling Point Range (BP) Final (FBP) ASTM D3710 Up to C15 Gasoline, Naphtha ~ -20 o C to 30 o C < 260 o C/500 o F ASTM C3 to C16 Gasoline, Naphtha ~ -20 o C to 30 o C < 280 o C/536 o F ASTM D2887 IP 406, ISO 3924 DIN 51435 C3 to C44 Jet Fuel, Diesel, Biodiesel Blends ~ 40 o C to 80 o C < 538 o C/1000 o F ASTM D5442 C17 to C44 Petroleum derived waxes < 538 o C/1000 o F ASTM D5307 C3 to C44 Crude Oil -30 o C to 100 o C < 538 o C/1138 o F ASTM D7398 C8 to C70 Biodiesel, B100 > 100 o C/212 o F <615 o C/1139 o F ASTM D7213 C5 to C70 Lube Oil, Base Oil > 100 o C/212 o F < 615 o C/1139 o F ASTM D6352 C5 to C90 Lube Oil, Base Oil > 100 o C/212 o F < 700 o C/1292 o F IP 480, EN 15199-1 C10 to C120 Lube Oil, Base Oil > 100 o C/212 o F < 750 o C/1382 o F ASTM D7169 C3 to C100 Residues, Crude oil -30 o C to 100 o C < 720 o C/1328 o F IP 507, IP 545, EN 15199-2, EN 15199-3 Up to C120 Heavy Distillate Residues, Crude Oil > 100 o C/212 o F > 750 o C/1382 o F ASTM D7500 C5 to C110 Lube Oil, Base Oil > 100 o C/212 o F < 735 o C/1355 o F ASTM D7900, IP 601 C1 to C10 Stabilized Crude Oil ~ > -30 o C Fraction < 170 o C ASTM D6417 C5 to C22 Volatility of Lube Oils IBP to 371 o C /700 o F < 700 o C/1292 o F Separation Systems offers comprehensive GC analyzers for all of these standard test methods.

Simulated Distillation Software without Compromise SimDis Expert is the best simulated distillation data analysis software available today. And, with the release of Version 10, more powerful than ever. It meets or exceeds all of the requirements of existing and proposed standard test methods. Its intuitive design is broadly recognized as the gold standard for being the easiest to learn while offering all of the functionality and advanced capabilities required to make your data to decision workflow simple and straightforward. SimDis Expert is compatible with all of today s chromatography data systems and can be tailored for your needs including support for selective detectors including FPD, PFPD, SCD, NCD and even MS. SimDis Expert is available in client and network server versions. The software fully reflects Separation Systems 40+ year dedication developing, testing and evolving simulated distillation test methods and contributions to advancing the state of the art. Key Software Highlights All current and proposed standard test methods are supported Utilizes a graphical user interface and straightforward analysis workflow D86 and D1160 correlations Full range of standard calculations: MOV, NOACK, Reid Vapor Pressure (RVP), CETANE index, sample average molecular weight Cut points can be calculated as average molecular weight Built in peak integrator with expanded integration parameters simplifies data reprocessing Full range of standard reports as well as the ability to create your own custom reports Fully customizable cut points Supports the use of selective detectors including MS Peak skew and column resolution determination based on multiple peaks User access levels can be assigned for security Single universal software driver to support all chromatography data systems Results can be exported as ASCII/CSV, to Microsoft Excel or OpenOffice Screen views can be exported to the Windows clipboard or as Windows Enhanced Metafiles (WMF) Built in Merge Expert for DHA front end correction of crude oil samples Intelligent adjustment of the peak/elution detection algorithm; it learns based on user defined elution marks Sample blending simulation model including aromatics and saturates analysis (ASA) Method configuration now includes detailed information about the scope of the method, chromatographic conditions and recommended standards and consumables AND SO MUCH MORE D2887 retention time calibration chromatogram, BP curve, and BP table including peak automatic skewness fit

BP(C) 700 600 500 400 300 200 100 HT SimDis without Quenching Correction HT SimDis with Quenching Correction HT SimDis with DHA Correction 0 15.0 30.0 45.0 60.0 75.0 %Off The boiling point curve for crude oil produced by high temperature simulated distillation can be corrected through the use of the included Merge Expert software to process boiling point data produced by a GC running a detailed hydrocarbon analysis (DHA) test method (ex. ASTM D6729, D6730, D7900) Meeting the Challenge of High Temperature Simulated Distillation 450 The design geometry and glass liner of our patented temperature programmable vaporizing SimDis Inlet work together to provide superior peak symmetry throughout the analysis and extend the lifetime of the column. 400 350 Signal (pa) 300 250 n-c120 200 SimDis Inlet 150 100 50 n-c100 n-c110 n-c120 15 20 25 30

Consumables for Simulated Distillation Analysis All of the consumable products we offer are designed or selected to ensure your ability to achieve superior simulated distillation results is as simple and straightforward as possible. All of the calibration standards we offer are produced and tested by us in house. Calibration and Response Factor Standards, Reference Materials Test Method Description Part Number D3710/ Retention time standard; 6 X 1 ml ampoules SD-008 D3710/ Response factor standard; 6 X 1 ml ampoules SD-007 D2887 Retention time standard; 0.1-1% C5-C44 in carbon disulfide; 6 X 1 ml ampoules SD-SS3E-01 D2887 D2887 Retention time & response factor standard; 0.01 0.1% C5-C44 in carbon disulfide; 6 X 1 ml ampoules Retention time standard; 0.02-0.2% C5-C44 as well as trace n-c3, n-c4, and i-c4 in carbon disulfide; 6 X 1 ml ampoules SD-SS3E-02 SD-SS3E-02-2X-WG D7213 Retention time standard; C5-C72 with C12 and C40 markers; Polywax 500 6 X 1 ml SD-SS3E-03 D7169, D6352 Retention time standard; C5-C26 Polywax 655; 10:1 carbon disulfide; 6 X 1 ml ampoules SD-SS3E-05 D7169, D6352 Response factor standard; C10 - C50; 6 X 1 ml ampoules SD-SS3E-05Q D6352 Retention time standard for D6352; C10-26 Polywax 655; 6 X 1 ml ampoules SD-SS3E-06 D2887 Reference gas oil Lot #2; 25 ml bottle SD-016-02 D2887 Reference gas oil Lot #2; 5 ml bottle SD-016-05 D7169, D6352 Reference material 5010; 25 ml bottle SD-020-01C D7169, D6352 Reference material 5010; 5 ml bottle SD-020-02 Columns, Septa, Inlet Liners, Ferrules, Gas Filters Test Method Description Part Number D3710, D2887 Column; packed (Procedure A) SD-001 Column; wide bore capillary SD-003 D2887 Column; wide bore capillary for ASTM D2887 (Procedure A); 10M SD-002-2 D2887 Column; wide bore capillary for ASTM D2887 (Procedure B); 5M SD-002-5M D7169, D6352 Column; metal clad wide bore capillary for ASTM D7169, D7213; 5M X 0.53 X 0.1µ SD-002HTE2 Septa; for use with SimDis Inlet with D7169, D6352; 25 pieces/package Septa; for use with SimDis Inlet with D2887; 25 pieces/package Ferrules; SimDis Inlet; 10 pieces/package Ferrules; for high temperature methods (D7169, D6352) detector side; 10 pieces/package Inlet liners; SimDis Inlet; 5 pieces/package Inlet liners; SimDis Inlet for fast analysis; 5 pieces/package SS-031-00 SS-031-00CONV SS-030-20 SS-030-20D SS-035-00 SD-035-00.1 All Gas filter; hydrocarbon trap for carrier gas SS-350-001 All Gas filter; oxygen indicating moisture trap SS-350-005 Please call 1-800-340-4402 for pricing, availability or to order.

About Us We are a minority owned business located in Gulf Breeze, Florida. We offer GC and GC- MS based analysis systems, application software, consumables, support and training for petroleum refining, bio-fuels and petrochemical applications. Our systems are comprehensive in nature and include a GC or GC-MS, our own specialized hardware and software, reference & calibration standards, consumables, training and support. While the majority of our systems are designed to meet the international standard testing method requirements (ex. ASTM, EN, ISO), we also design systems for special requirements including custom software. Your One Source for Simulated Distillation Headquarters Separation System, Inc. 100 Nightingale Lane Gulf Breeze, Florida 32651 USA Telephone: 1-800-340-3302 Email: sales@separationsystems.com Web: www.separationsystems.com www.separationsystems.com