NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

Similar documents
NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

NEOZED D0 fuse-links gg 400/440VAC

Protistor size 70 gr 690VAC (IEC)

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Limitor -G General Purpose Fuses

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

NH DIN Dual Indication Fuse Links

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

NH DIN Dual Indication Fuse Links

NH HRC Fuses. IEC & British Standard Fuses NHG B

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

IEC Low Voltage Products Module 4

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Leadership in Circuit Protection

fuse-links & fuse holders PHOTOVOLTAIC

Leadership in Circuit Protection

NH Solid Blades 690 VAC sizes 000 to 3

Bussmann series NH catalogue. Leadership in circuit protection

Low voltage NH knife-blade fuse-links

Protistor size 120 gr 750VDC (IEC)

Semiconductor (AC) fuses

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

NH LOW VOLTAGE a FUSE SYSTEM

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

NH Dual NHIndicator Fuse System Fuse System

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

NH (H.R.C) FUSES AND FUSE BASES

Semiconductor Fuses European Fuses

onlinecomponents.com

BETA Fuses and Fuse Systems

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Disconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)

RAPIDPLUS. high speed fuse links for semiconductors

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

High-voltage high-breaking capacity VV fuse-links

Disconnectors FA range 750VDC 250 to 2000Amp

RAPIDPLUS. high speed fuse links for semiconductors

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

High voltage high-breaking capacity VV fuse-links

LV Capacitor CLMD03 Power Module Instruction manual

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

International products

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

NH-Fuse system Low voltage

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

MANUALLY OPERATED CHANGEOVER SWITCHES

IEC Low Voltage General Purpose Protection

DBM Range 1500VDC (13,5kA to 20kA)

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

500 Volts gg/gl NH Fuse links

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Load Break Disconnect Switches FSLBS

3NP1 Fuse Switch Disconnectors up to 630 A

GMA GDB/GDA MDL MDA. Fuses SMALL DIMENSION. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price

General Purpose IEC Fuses

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

Bussmann series IEC cylindrical fuses

Utilisation category gl/gg 500VAC with combi indicator

UL 508 Non-Fusible Disconnect Switches

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1

500 and 690 V a.c. am NH fuse links

LINOCUR Size D02 63A 230VAC/440VAC

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV


UL 508 Non-Fusible Disconnect Switches

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Bussmann series NH bases

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Medium Voltage current limiting Fuse links

Low-Peak 600V Class RK1

MEDIUM VOLTAGE DIN Fuse-Links

Selector guide. PSC Square body fuses Size 3X VAC End Contact Terminals. Features and Benefits

Medium voltage fuses Medium voltage fuses

INDUSTRIAL CYLINDRICAL FUSE LINKS

Vistop TM isolating switches 63 to 160A

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

fuses fuse holders CYLINDRICAL

Medium Voltage current limiting Fuse links

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Transcription:

IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional. Features Benefits z Dimensions according to DIN 43 620 Parts 1 to 4 standard z Non-isolated gripping lugs z Double indicator z Lead free contact blades z 0% cadmium Applications z gg: general purpose cable and line protection Technical data overview Volt (VAC) 500 VAC Ampere Range (A) 2... 800 A Size per Standard Sizes 000, 00, 0, 1, 2, 3 Speed/Characteristic gg I.R. AC (ka) 120 ka Body Material ceramic Materials Contact copper, silver-plated Standards DIN 57636 Part 201 VDE 0636 Part 201 IEC 60269-1 and -2 www.ep.mersen.com 1

Product range Size 000 NH000GG50V2 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n Weight NH000GG50V2 B211946 500 V 2 A 1.9 W 130 g 3 NH000GG50V4 M212462 500 V 4 A 1.5 W 130 g 3 NH000GG50V6 D213995 500 V 6 A 1.6 W 130 g 3 NH000GG50V10 B219651 500 V 10 A 1.1 W 130 g 3 NH000GG50V16 K222097 500 V 16 A 1.8 W 130 g 9 NH000GG50V20 A222847 500 V 20 A 2.3 W 130 g 9 NH000GG50V25 E201185 500 V 25 A 2.4 W 130 g 9 NH000GG50V32 Z211438 500 V 32 A 3.1 W 130 g 9 NH000GG50V35 C211947 500 V 35 A 3 W 130 g 9 NH000GG50V40 N212463 500 V 40 A 3.7 W 130 g 9 NH000GG50V50 T212974 500 V 50 A 4.1 W 130 g 9 NH000GG50V63 E213996 500 V 63 A 5.4 W 130 g 9 NH000GG50V80 Y216543 500 V 80 A 6.5 W 130 g 9 NH000GG50V100 B219122 500 V 100 A 7.5 W 130 g 9 Package Size 00 NH00GG50V125 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n Weight NH00GG50V125 R201863 500 V 125 A 10 W 200 g 3 NH00GG50V160 P211084 500 V 160 A 12.3 W 200 g 3 Package NH0GG50V6 Size 0 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n www.ep.mersen.com 2 Weight NH0GG50V6 H213148 500 V 6 A 1.6 W 270 g 3 NH0GG50V10 G214159 500 V 10 A 1.1 W 270 g 3 NH0GG50V16 Q215179 500 V 16 A 1.8 W 270 g 3 NH0GG50V20 R215686 500 V 20 A 2.3 W 270 g 3 NH0GG50V25 Y216198 500 V 25 A 2.4 W 270 g 3 NH0GG50V32 W216702 500 V 32 A 3.1 W 270 g 3 NH0GG50V35 J217220 500 V 35 A 3 W 270 g 3 NH0GG50V40 P217731 500 V 40 A 3.7 W 270 g 3 NH0GG50V50 Z218246 500 V 50 A 4.1 W 270 g 3 NH0GG50V63 N218765 500 V 63 A 6.6 W 270 g 3 NH0GG50V80 C219284 500 V 80 A 8 W 270 g 3 NH0GG50V100 D219814 500 V 100 A 9.4 W 270 g 3 NH0GG50V125 P222492 500 V 125 A 11.8 W 270 g 3 NH0GG50V160 F223013 500 V 160 A 14.6 W 270 g 3 NH0GG50V200 C229611 500 V 200 A 18.1 W 270 g 3 NH0GG50V224 D229612 500 V 224 A 19.2 W 270 g 3 NH0GG50V250 E229613 500 V 250 A 20.3 W 270 g 3 Package

Product range Size 1 NH1G- G50V16 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n Width Weight Package NH1GG50V16 M200801 500 V 16 A 1.8 W 29.5 mm 280 g 3 NH1GG50V20 C201344 500 V 20 A 2.3 W 29.5 mm 280 g 3 NH1GG50V25 N201860 500 V 25 A 2.4 W 29.5 mm 280 g 3 NH1GG50V32 L211081 500 V 32 A 3.1 W 29.5 mm 280 g 3 NH1GG50V35 A211600 500 V 35 A 3 W 29.5 mm 280 g 3 NH1GG50V40 Y212633 500 V 40 A 3.7 W 29.5 mm 280 g 3 NH1GG50V50 B213648 500 V 50 A 4.1 W 29.5 mm 280 g 3 NH1GG50V63 L214669 500 V 63 A 6.6 W 29.5 mm 280 g 3 NH1GG50V80 S215687 500 V 80 A 8 W 29.5 mm 280 g 3 NH1GG50V100 X216703 500 V 100 A 9.4 W 29.5 mm 280 g 3 NH1GG50V125 Q217732 500 V 125 A 11.8 W 39.5 mm 300 g 3 NH1GG50V160 A218247 500 V 160 A 14.6 W 39.5 mm 300 g 3 NH1GG50V200 P218766 500 V 200 A 18 W 39.5 mm 300 g 3 NH1GG50V224 D219285 500 V 224 A 19 W 39.5 mm 300 g 3 NH1GG50V250 E219815 500 V 250 A 20 W 39.5 mm 300 g 3 NH1GG50V315 Q228519 500 V 315 A 20.5 W 39.5 mm 420 g 3 NH1GG50V355 R228520 500 V 355 A 23.7 W 39.5 mm 420 g 3 NH2G- G50V63 Size 2 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n Width Weight Package NH2GG50V25 N200802 500 V 25 A 2.4 W 39.5 mm 420 g 3 NH2GG50V32 D201345 500 V 32 A 3.1 W 39.5 mm 420 g 3 NH2GG50V35 P201861 500 V 35 A 3 W 39.5 mm 420 g 3 NH2GG50V40 M211082 500 V 40 A 3.7 W 39.5 mm 420 g 3 NH2GG50V50 B211601 500 V 50 A 4.1 W 39.5 mm 420 g 3 NH2GG50V63 Z212634 500 V 63 A 6.8 W 39.5 mm 420 g 3 NH2GG50V80 C213649 500 V 80 A 8.3 W 39.5 mm 420 g 3 NH2GG50V100 M214670 500 V 100 A 10.7 W 39.5 mm 420 g 3 NH2GG50V125 T215688 500 V 125 A 12.2 W 39.5 mm 420 g 3 NH2GG50V160 Y216704 500 V 160 A 15 W 39.5 mm 420 g 3 NH2GG50V200 R217733 500 V 200 A 18.5 W 39.5 mm 420 g 3 NH2GG50V224 Q218767 500 V 224 A 19.2 W 39.5 mm 420 g 3 NH2GG50V250 R222494 500 V 250 A 20.6 W 39.5 mm 420 g 3 NH2GG50V300 P200803 500 V 300 A 21 W 51 mm 640 g 3 NH2GG50V315 E201346 500 V 315 A 25 W 51 mm 640 g 3 www.ep.mersen.com 3

Product range Size 3 Catalog Reference Rated voltage AC (IEC) Rated current I n Power dissipation at I n Width Weight Package NH3GG50V250 C211602 500 V 250 A 21.1 W 51 mm 650 g 1 NH3GG50V300 A212635 500 V 300 A 20 W 51 mm 650 g 1 NH3GG50V315 L213151 500 V 315 A 25 W 51 mm 650 g 1 NH3GG50V355 K214162 500 V 355 A 32 W 51 mm 650 g 1 NH2GG50V355 Q201862 500 V 355 A 31.5 W 51 mm 640 g 3 NH2GG50V400 N211083 500 V 400 A 28.5 W 51 mm 640 g 3 NH3GG50V400 T215182 500 V 400 A 34 W 51 mm 1050 g 1 NH3GG50V425 B216201 500 V 425 A 34 W 70 mm 1050 g 1 NH2GG50V425 S228521 500 V 425 A 29.2 W 70 mm 640 g 3 NH3GG50V450 Z216705 500 V 450 A 38 W 70 mm 1050 g 1 NH3GG50V500 M217223 500 V 500 A 43 W 70 mm 1050 g 1 NH2GG50V500 T228522 500 V 500 A 35.6 W 70 mm 640 g 3 NH3GG50V630 S217734 500 V 630 A 43.1 W 70 mm 1050 g 1 NH3GG50V800 V228523 500 V 800 A 53.2 W 70 mm 1050 g 1 Technical Data Size 000 Size 00 Size 0 Size 1 Size 2 Size 3 Rated current 2... 100 A 125... 160 A 6... 250 A 16... 355 A 25... 315 A 250... 800 A Rated breaking capacity AC 120 ka 120 ka 120 ka 120 ka 120 ka 120 ka Rated voltage AC 500 V 500 V 500 V 500 V 500 V 500 V Indication System double indicator double indicator double indicator double indicator double indicator double indicator Width 20.8 mm 29.5 mm 29.5 mm - - - www.ep.mersen.com 4

Time current characteristic curves NH fuse-links gg 2A to 800A 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 200 224 250 315 355 400 500 630 800 10000 Actual prearcing time (s) 1000 100 10 1 0,1 0,01 1 10 100 1000 10000 100000 A RMS value of prearc current (A) ± 10% www.ep.mersen.com 5

Current limiting diagram 50 Hz rms symetrical prospective current (Ip) A) Maximum peak let thru current (A) www.ep.mersen.com 6

Characteristics total I²t curve Nominal Current (A) Prearcing and Clearing I²t (A²s) www.ep.mersen.com 7

Dimensions IEC LV NH-fuse link size 000 with double indicator (0118997C) Indicator is visible after operation of fuse 49 ± 1.5 45 ± 1.5 2.5 +1 0.5 15 min 52.5 1 35 ± 0.8 16 +5 6 0 2.5 0 0.5 41 max 2 min = = 21 max 78.5 ± 1.5 Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. 6 ± 0.2 Dimensions in mm www.ep.mersen.com 8

Dimensions IEC LV NH-fuse link size 00 with double indicator (118998 D) 49 ± 1.5 45 ± 1.5 20 ± 5 Indicator is visible after operation of fuse 2 +1 0.5 15 min 60 max 1 6 0 35 ± 0.8 2.5 0.5 0 48 max 2 min = = 78.5 ± 1.5 30 max Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. Dimensions in mm 6 ± 0.2 www.ep.mersen.com 9

Dimensions IEC LV NH-fuse link size 0 with double indicator (118999 C) Indicator is visible after operation of fuse 68 +1.5 3 62 +3 1.5 2,5 +1.5 0.5 6 0 20 ± 5.5 2.5 0.5 0 15 min (61 max) 11 0 0.2 35 ± 0.8 48 max = = 30 max 125 ± 2.5 Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. 6 ± 0.2 2 min Dimensions in mm www.ep.mersen.com 10

Dimensions IEC LV NH-fuse link size 1 with double indicator (119000 C) Indicator is visible after operation of fuse 68 ± 2.5 62 ± 2.5 2.5 +1.5 0.5 6 0 20 +5 2.5 +0.5 0 135 ± 2.5 Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. 6 ± 0.2 20 min (64 max) 40 ± 0.85 53 max 2 min 11 0 40 max Dimensions in mm www.ep.mersen.com 11

Dimensions IEC LV NH-fuse link size 2 with double indicator (119001 C) 68 ± 2.5 Indicator is visible after operation of fuse 62 ± 2.5 2.5 +1.5 0.5 6 0 20 +5 150 ± 2.5 Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. 6 ± 0.2 25 min (74 max) 11 0 48 ± 0.8 60 max 2 min 2,5 +0.5 0 52 max Ech. 1/2 Scale Dimensions in mm www.ep.mersen.com 12

Dimensions IEC LV NH-fuse link size 3 with double indicator (119002 C) Indicator is visible after operation of fuse 68 ± 2.5 62 ± 2.5 2.5 +1.5 0.5 32 min (89 max) 11 0 60 ± 0.8 6 0 20 +5 2.5 +0.5 0 76 max 2 min = = 150 ± 2.5 72 max Visibility of red indicator signals conduction of the fuse-link. After operation the red indicator is no longer visible. 6 ± 0.2 Ech. 1/2 Scale Dimensions in mm www.ep.mersen.com 13