Visual inspection Inspect lift functions regularly. Check to ensure that material is free from damage.

Similar documents
Eva450EE. Functional inspection. Always read the manual. SystemRoMedic TM. Manual - English

adopts a holistic approach to patient transfers and is organized in four categories: transfer, positioning, support and lifting.

Eva400EE/Eva400EM. Functional inspection. Always read the manual. SystemRoMedic TM. Manual - English

Liko M220 / Liko M230

Viking L. Product Description. Instruction Guide

Instruction Guide. English. Uno 100/102 - EM, EE, ES 7EN

Transfer Motor Likorall ES

Likorall 242/243/250. Product Description. Instruction Guide. Likorall 243 ES. Likorall 243, 250. Likorall 242 R2R

Overhead lift Roomer 5200

FreeSpan UltraTwin. Product Description. Instruction Guide

Viking M / Viking L / Viking XL

Uno 100/102. Product Description. Instruction Guide

Multirall 200. Product Description. Instruction Guide

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used.

Multirall 200. Product Description. Instruction Guide

Multirall 200. Prod. No

Golvo. Product Description. Instruction Guide

RiseAtlas450M, with QuickTrolleySystem SystemRoMedic TM

SGA-440 by Prism Medical

Product Description. In this document, the person being lifted is referred to as the patient, and the person helping is referred to as the caregiver.

Molift Quick Raiser 205

Prism A-205. Owner s Manual. Aluminium Mobile Hoist. Use and Care Trouble Shooting Warranty Information. Introduction Overview...

Molift Mover 300. EN - User manual. BM06101 Rev. F

Molift Mover 180. EN - User manual. BM08101 Rev. D

All-in-One Hoist User Manual , , ,

Instructions for use. digital. Bure Rise & Go Walker and Stand-aid with Power Rise Function. Bure Rise & Go

Molift Partner 255. EN - User manual. BM03101 Rev. L

Molift Mover 205. EN - User manual. BM05101 Rev. L

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing Push Handle. Base Width Adjustment Handle.

Instructions for use Shower stretcher Marina

Wheelchair Safety, Maintenance and Operations Guide

Turner PRO. User manual. BM61099 Rev B

Bure Rise & Go Walker and Stand-aid with Power Rise Function

USER MANUAL. Item: #13246 Stand-Aid Lift. Drive Medical Design and Manufacturing

R710. R710 Product Manual

Oxford. Manufacturer s Contact Details. Contents. Oxford Presence. English

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

PRISM MEDICAL UK SA160C STAND AID

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

New Products offering 2014

U S E R M A N U A L. To avoid injury, read user manual prior to use. enablelifecare.com.au. Hoyer Journey. Joerns Hoyer Presence

Ensure the product has been assembled according to the instructions in this manual.

FGSH-450 by Prism Medical

Graduate 150 Scholar 175 Master 200

Mobile Shower Commode Chair

Free Standing Track. Owner s Manual. Use and Care Trouble Shooting

Introduction. Components. Do the following

DOC /500/600 Series Sit to Stand Lift Owner's Manual REV 001

Table of contents 1 Introduction 2 Suitability 3 General safety instructions 4 Adjustments 24 5 Seat location selection and adjustment

solutions to life's challenges

Able Assist Transfer Aids User Manual

User s Instruction Manual Rise IIIS Hoisting Shower-, Commode- & Care Chair w. Tilting Seat

Likorall. LOAD TESTING 12 Mechanical lowering load test (242) Maximum load rail system... DOCUMENTATION 14 Instructions / Instruction guide...

Contents. Oxford Calibre. English

320 kg yoke diagnostic

Instruction Manual. Made in Israel Distributed by:

180 kg yoke or pivot diagnostic

Mobile Shower Commode Chair

Instruction Manual UK

RESTWELL RISE & RECLINE ARMCHAIRS LARS AND SVEN - OWNER S HANDBOOK MODEL DESCRIPTION

Advancement Chair. R901, R902, & R903 Product Manual

PCBL 1600/1800 POWER WHEELCHAIR MODERN USER'S MANUAL Edition

Vanturn Service Manual

Unihoist Ltd. Range of Electric & Hydraulic Hoists

190/195 Tilt Shower Commode User Manual

Owner s Manual. Transport / Companion Wheelchairs M4TV M2TF M2TC M2TL HEALTH PRODUCTS, INC.

SARA PLUS THE ADVANCED STANDING AND RAISING AID

atient lifters Assembly, Maintenance & Specifications Manual SUNRISE HML400 Hoyer Manual Patient Lift HPL400 Hoyer Power Patient Lift Sunrise Medical

A205 Patient Lifter - Aluminium USER MANUAL

SERVICE MANUAL. Seat system for electric wheelchair

User Manual SONESTA S2 & S3

QA4 Surgery Trolley System Manual Function Operating Instructions

Marlin Bath Lift BLM-8200 WARNING! Read ALL instructions before using this product!

U S E R M A N U A L. To avoid injury, read user manual prior to use. enablelifecare.com.au. Joerns Hoyer Presence

seca 954 D GB F I E Instruction manual and guarantee

MINOS GLOBAL ALU User Manual

User Manual. Use and Care Fault Finding Warranty Information. Unit 1, Tir Llwyd Industrial Estate, St Asaph Avenue, Kinmel Bay, Rhyl, Conwy, LL18 5JZ

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

2 in 1 Rollator and Transit Chair M58203

PCBL 1610/ 1810 DE LUXE POWER WHEELCHAIR USER'S MANUAL Edition

BATTERY OPERATED PATIENT LIFT MODEL: 650HD OWNER'S MANUAL

Table of Contents Zitzi Flipper Pro 6:1 6:2 6:3 6:4 6:5 7:1 7:2

User Guide. Always abide by this User Guide

BATTERY OPERATED PATIENT LIFT MODEL:650HD OWNER S MANUAL

A200S Patient Stander - Aluminium USER MANUAL

ATLAS SIT-TO-STAND LIFT

User Instructions Shower and Commode Wheel Chairs

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

Self-propelling Shower and Commode Wheel chairs

Poollift Neptune with Transporter

RehabCare Avnvej 10 DK-7400 Herning

SARA PLUS INSTRUCTIONS FOR USE

User guide Operator chair Carl Carl Foot and Carl Heel

EASY RIDER CONTROLS Fitting Instructions for portable hand control

Heavy Duty Four Wheeled Walker

K710 Product Manual. Support Station. K710 Product Manual

Ultima & Ultima Access Bath Transfers with Foldable Base

Booster Car Seat User Guide

User Instruction Manual Hoyer. HPL700 and HPL700WSC To avoid injury, read user manual prior to use.

Transcription:

MiniLift200 Manual The MiniLift200 is an electrically powered stand-up lifter for people with impaired mobility and strength and who are unable to stand up unassisted. The MiniLift200 is designed for indoor use and is designed to be used by a caregiver who attaches the sling to the user and operates/manoeuvres the unit. To be able to use this Minilift200, the user must have a degree of stability above the knees, i.e. he/she must have some remaining standing fuction. At the same time, the MiniLift200 trains the user s leg muscles as well as their sense of balance and endurance. The MiniLift200 is CE-marked under Medical Equipment, class 1. Max Load: 200kg / 441lbs RoMedic s slings and lifts are part of the SystemRoMedic concept, which takes a holistic approach to patient transfers. SystemRoMedic has four categories: transfer, repositioning, support and lifting. Functional inspection Visual inspection Inspect lift functions regularly. Check to ensure that material is free from damage. Always read the instructions Read instructions for all assistive devices used in connection with transfers. Keep the manual where it is accessible to users of the product. Do not leave the patient unattended during a lifting situation. Checklist before use: Make certain the lift is properly assembled. Lifting accessories must be properly trial fitted and tested in relation to the patient s needs and functional ability. Check Slingbar connection and safety latch function. Check lift lifting function and base-width adjustment. Under no circumstances may the lift be used by persons who have not received instruction in the operation of the lift. Manual nr: 00874-EN ver. 2 090513 EAN no: 733176901169 7 1

Table of contents Technical information 2 Important information 3 Maximum load 3 MiniLift200 Parts 4 Assembling MiniLift200 5 Measurement MiniLift200 6-7 Final inspection 8 Operation 9 Funktions on the controlbox/batteri 10 Emergency stop, emergency lowering 11 Charging 11 Trial operation of MiniLift200 12-14 Trouble-shooting 15 Other maintenance details 15 Technical information Lifting speed: 1.5 cm/s without load Controlbox: 24V DC, 9A Batteries: 24V DC 2,9 Ah, IP65 Charger: Built-in charger, 100-240 VAC, 50-60 Hz, max 400 ma Motor (mast): DC24 V, 10,5 AH. IP54. Operationtime: 10% at maximum continous running of 2 minutes. Push: 7500 N. Motor (base): 24 V DC, 12,3 AH, IP54. Operationtime: 10% at maximum continous operation of 2 minutes. Push: 2000N. Material: Steel Emergency lowering: Mechanical and electrical Castors: Back 4,100mm, front 3, 80mm IP class: IP54 A-weighted sound power level: 55,8 DBA Approval: EN 60601-1 Confirm to UL 60601-1 and CAN/CSA-C22.2 No.601.1-M90, ISO 10535:2006. The device is intended for indoor use. Type B, according to the degree of protection against electric shock. www.romedic.com 2

Important information MiniLift200 must be assembled in accordance with the assembly instructions provided by RoMedic. Warranty does not apply if repairs or alterations are made to the lift by personnel who are not authorized by RoMedic. Batteries control box and actuator on MiniLift must not come in direct contact with water. To ensure optimal function, the lift must be inspected regularly. See section on other maintenance details. Only use MiniLift200 on flat surfaces. Do not push Never move the lift by pulling on the actuator! Under no circumstances may max. load be exceeded. See section on technical information and the product decal on the lift. Lifting accessories must be properly trial fitted and tested in relation to the patient s needs and functional ability. MiniLift200 may not be charged in wet areas or used during a shower and bath. Lift shall not be exposed to running water. Maximum load: It may be different maximum allowable loads to different products on the assembled lift system: lift, slingbar, sling, scale, and others accesories. It is always the lowest maximum allowable load indicated for the respective products on the system that applies. Always check the markings on all products in the unit and contact RoMedic representativ if you have any questions. 3

MiniLift200 parts 1. Lifting arm. 2. Hooks for attaching the sling. 3. Hand control unit for adjusting the lifting arm and legs spread. 4. Shin pad unit. 5. Footplate. 6. Castors: Rear are braked. 7. Battery. 8. Red emergency stop button, control box. 9. Knob for adjusting the height and depth of the shin pad unit. 10. Manual down button for lowering arm. Note: the mechanical down button is located on the actuator and is manually operated. 11. Electric down button. 12. Charging: lamp on. Fully charged: lamp off. 13. Stopper for sling loops. 14. Lock for adjusting telescope lifting arm, in and out. 15. Push bar. 2 1 14 15 13 3 4 7 10 8 9 11 5 12 6 www.romedic.com 4

Assembling MiniLift200 Check to ensure that all components are included: Lift motor, control box and battery pack. Base with motor.foot rest Handset and cord. Instructions, charging cable and power supply cord for charging. Assembly: Place the upper section (1) above the lower section DETAIL (2) and A carefully lower it onto the lower section. Push all the way down. Insert the bolts (3) in all four tubes and tighten. Finally, place the cap nuts (4) on the bolts. 1 3 A 4 2 Assemble the footplate by attaching it to the crossbar and swinging it down. Make sure the pins (6) insert into the holes of the plate. Attach the leg spreading cable to the control box. 5

Measurement MiniLift200 1 2 www.romedic.com 6

Measurement Mini Lift 200 Measurement Tolerance +/- 5mm A Length 950 mm B Width inside min. legspread 480 mm Width indside max. legspread 930 mm C Width outside min. legspread 590 mm Width outside max. legspread 1030 mm D Height 1010 mm E Maximum reach at 600 mm (reference height) 295 mm Max height from the base 1375 mm F Height at base 135 mm G Clearance at base 90 mm H Lifting height min. 880 mm I Lifting height max. 1500 mm J Hoisting range 620 mm K1 Min. distance from wall to CSP at max. Height ( legs spread) 860 mm Minimum distance from wall to CSP at max. reach ( legs spread) 410 mm K2 Min. distance from wall to CSP at min. height ( legs spread) 410 mm L Footplate, clearance 50 mm M Footplate, height 80 mm N Inside space between bars 525 mm O Overall length 1000 mm P Reach from base with legs spread to 700 mm 570 mm R Max. reach from base 425 mm Max. load 200 kg Total weight 52 kg Weight loose parts ( footplate) 5 kg Number of lifts per charge 20-25 Footplate, dimensions ( W x D) 390 x 345 Materiale frame Steel Wheels Ø80/Ø100 Turning diameter 1050 Lifting speed unloaded 15mm/sec Lifting speed with load 7mm/sec 7

Operation: These instructions must be followed for correct use of the MiniLift200. Warning: Because of the actuator s squeeze-protector, the lifting arm can fall freely down to the actuator position. Press the lifting arm on the stand-up lifter downwards to make sure it supports the lift actuator before and after all lifting operations. This must be done, because otherwise there is a risk of injuring the user when the lifting arm falls down. Operating the MiniLift200 via the hand control: The MiniLift200 has four functions: up, down, out and in. Press the respective arrow buttons (up, down, out or in) for the desired function. It is not possible to use two functions simultaneously. NOTE: Make sure the emergency stop button is disengaged. Setting the lifter in motion: Push the push bar to set the lifter in motion. This is the safest way to move the stand-up lifter. NOTE: A stand-up lifter is not a means of transport. Moving a person using the MiniLift200: The width of the lower section must be adjusted to achieve the greatest possible stability. This is the safest way to move the stand-up lifter. NOTE: A stand-up lifter is not a means of transport. Turning: To turn the stand-up lifter, stand beside the lifter and grasp the side bar with one hand and the push handle with the other, pushing with one hand and pulling with the other. Do this at a calm, steady pace to prevent the user from losing their balance. Warning: Do not place your hand by the actuator as you risk pinching your fingers. Use: The MiniLift200 must only be used for moving people and only people who do not weigh more than the specified maximum load (including sling). If the MiniLift200 is used for loads that exceed the specified maximum load or for lifting anything other than people, any and all product liability on the part of Handicare A/S Danmark relating to insurance/guarantee/service will cease. To avoid accidents or personal injury to the user of the stand-up lifter and to the operator of the stand-up lifter, the stand-up lifter must be operated as described in points 1 through 5. 8 www.romedic.com

Final inspection Inspect the lift for signs of wear and damage. Check all four castors and castor locks. Check all connections and fixtures including screws and bolts. Check the packaging for any loose bolts and screws. If you find any, locate their intended positions on the lift and replace them. Check emergency stop function by depressing the emergency stop, and then pressing either the Up or Down button. If nothing happens when the Up or Down buttons are pressed, the emergency stop is functioning properly. Grasp the handset, press the Up button and run the liftarm all the way up. Then, press the Down button and run the liftarm all the way down. Test lift function by lifting a person (not a patient) using an approved sling. At the same time, check the emergency lowering function with someone on the lift. If the equipment is satisfactory upon inspection, connect the freestanding adaptor for charging to the lift and to a power outlet, and then check to ensure that the charging lamp on the control box lights up. NOTE! Before the lift is used for the first time, it must be charged for at least 4 hours. See section on Charging batteries. Place the manual where it is easily accessible near the lift. 9

The controlbox/batteri has the following functions: Emergency stop that disconnects the power to and from the batteries. Emergency lowering button that lowers the lifting arm if problems arise with the hand control unit. Visual battery indicator Beeper which emits a signal when the batteries need to be charged. Plug for hand control unit (see drawing) Plug for lifting motor (see drawing) Plug for width adjustment (see drawing) Control box IP65 To protect the electronic equipment, the hand control unit is also furnished with a motor protection switch for the lifting function. www.romedic.com 10

Emergency stop To activate emergency stop: Depress the red emergency stop button on the control box. Resetting: Turn the button in the direction of the arrows until the button pops out. Emergency lowering To activate the mechanical lowering function, pull up on the red handle. Charging Charge the lifter after each period of daily use so you are always certain the lifter is fully operational (e.g. charge it every night). Charging the MiniLift200: Plug the mains cable from the control unit into an outlet. When the batteries are charged, the charger will turn off automatically. Remember: The emergency stop button must be disengaged / out. Battery: 24V DC. 2,9 Ah, IP65. The average battery service life is two years, depending on the amount of use. 11

Trial operation of MiniLift200 Only ThoraxSling must be used in combination with the MiniLift200, as the MiniLift has a special movement of raising the user up, and the slings are designed for the attachment of the MiniLift only. See the manual for ThoraxSling for application. Next, position the MiniLift200 as close as possible to the user. Place the user s feet as far forward on the footplate as possible. The knee pad unit should be all the way back as a starting point. Warning: When adjusting the leg width, there is a risk of squeezing the user s feet. Therefore, always make sure to place the user s feet on the footplate. Adjust the shin pad unit so that the top of the pad is just below the user s kneecap and at least with enough space to slip a hand between shin and pad. Pull up the locking bolt. Pull the lifting arm all the way towards the user. Warning! Release bolt all the way down to lock lifting arm in fixed position. www.romedic.com 12

Attach the sling loops to the lifting arm from below the lifting arm. Fasten the sling loops to the hooks on the lifting arm. N.B. Attach loops to hooks from underneath the handle bar. Choose the closest loop as innermost as possible - and attach to hook. Warning: Keep an eye on the user s hands during the lifting process, as there is a risk of pinching them with the sling straps. Push the liftarm back as much as possible and make sure its safely locked. Warning: Check the lifting arm is locked in position before proceeding with the lift. Have the user place his/her hands on the lifting arm handle. We recommend that the caregiver stand at the side of the user, place a hand on the user s shoulder, and ask the user to lean back slightly. Begin lifting to a standing or semi-standing position. Adjust the waist strap when the user has been lifted slightly. Note!!! The wheels on the lifter (and wheelchair, if relevant) must be unlocked. 13

Lowering the user: Move the MiniLift close to the chair/bed, where the user is to be seated, so that the edge of the chair is just behind the hollow of the knees of the user. Lock the wheels on the MiniLift. The user shall be guided to lean slightly back while he/she is lowered down into sitting position. Use the straps at both sides of the sling to guide the user into the right position. Pull the liftarm out in it`s longest position before removing the loops from the hooks. Unlock the buckle and remove the sling. www.romedic.com 14

Trouble-shooting If the lift is not working properly (up or down), check the following: Make sure the emergency stop button is not pressed in and that all cables are connected. Check the battery level and check to ensure that the battery charges via the adaptor. If the lift is not working properly, contact RoMedic. The lift can be raised but not lowered (or vice versa), or the base-width adjustment only works in one direction. Check the following: That all cables are properly and securely connected. Pull out the contact and plug it in again firmly. If the lift is not working properly, contact RoMedic. If the lift makes unusual noises: Try to locate the source of the sound, take the lift out of operation and contact RoMedic. Other maintenance details: The lift must undergo thorough inspection at least once per year. This must be done by authorized RoMedic service personnel and in accordance with RoMedic s service manual. Repairs and maintenance may only be done by authorized personnel using original spare parts. Old batteries are to be left at the nearest recycling station or given to personnel authorized by RoMedic. Disposal The MiniLift200 can be seperated into metal, plastic and electronic parts for recycling and disposal. The electronic parts must be disposed regarding the WEEE -directive. Cleaning and disinfection When necessary, clean the lift with warm water or rubbing alcohol and ensure that the castors are free of dirt and hair. Do not use cleaning agents containing phenol or chlorine. Storage If the lift is not to be used for some time or e.g., when transporting, we recommend that the emergency stop button be pressed in. Store the lift at a temperature exceeding freezing point and at normal relative humidity (about 60%). Service agreements RoMedic offers the possibility of service agreements for maintenance and regular testing of your lift. Contact your local RoMedic representative. 15

SystemRoMedic RoMedic s lifts and lifting accessories are part of SystemRoMedic. This means they are part of a holistic approach to lifting and transferring. SystemRoMedic includes four transfer segments: transfer, repositioning, support and lifting. RoMedic s products are developed on an ongoing basis, which is why we reserve the right to modify product designs without prior notice. Contact your RoMedic representative for information, advice and updates. When in doubt, contact your RoMedic representative for product trials, advice or information. If you require additional information, contact your transfer specialist or our representative, or visit www.romedic.com. Make sure you always have the most recent version of the manual. Manuals are available for downloading from our website; http://www.romedic. com RoMedic AB Veddestav. 15, Box 640 Tel: +46 (0)8-594 773 33 Internet: www.romedic.com SE-175 27 Järfälla Fax:+46 (0)8-594 773 44 E-mail: office@romedic.com www.romedic.com SWEDEN 16