Solenoid Operator 0516 / 1216

Similar documents
Solenoid Operator 0513 / 1213

Ex m Solenoid Operator Type 0519

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Solenoid coils VACF Type codes

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

System 6. Solenoid Coils Armature Assemblies Valve Systems

10 Load and Motor Switchgear

Type 6213 EV, 6281 EV

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Spring-applied single-disc brake with dust and explosion protection II. Operating Instructions 76..G..B00 EEX LINE

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Limit Switch Type 4747

Linear Luminaire for Fluorescent Lamps

Solenoid coil for control in potentially explosive areas Type BZ

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

IQL Helios Area-/Streetlight. User Manual

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Sensor boxes SRBE Key features and product range overview

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

11 Control Panels, Distribution Panels and Components

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

97100 NAMUR. Technical data

Instruction Manual. Ex-Time 40 / 50

Proportional Solenoid for Hydraulics ATEX + IECEX

Solenoid Valves Type 3963

MINI MCR-SL-UI-UI(-SP)(-NC)

Operating Instructions

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Operating Instructions

SITRANS P measuring instruments for pressure

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Electromagnetic single-face clutch. Operating Instructions E00 ACTIVE CLUTCH LINE

Operating Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions (Translation)

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Explosion and flame-proof cast iron electric motors

2/2 Solenoid Cartridge Valve, Size 6

System 13. ü ( System 13

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

A good connection. International approvals.

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Modular Explosion Proof Brakes. IECLine rev 0

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

HERION SERIES Indirect solenoid actuated soft seal

Unused flameproof threads for cable glands have to be closed with certified plugs.


3/2 and 4/2 directional seat valves with solenoid actuation

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Technical Data. Dimensions

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Level Measuring Sensor for Diesel Fuel Tanks

Explosion and flame-proof single phase electric motors

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Operating pressure (bar) kv factor (m 3 /h) *3)

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Control and Terminal Box Type A21-**-*****

RVP-R- VAV controller. In explosion-proof version

97105 Inline. Ordering information. Technical data. Accessories See page 5

FICHA TÉCNICA DE PRODUTO

Solenoid System FLANGE MOUNTING VERSION

Operating Instructions

Lifting / Lowering valve type HSV and HZV

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

IECEx Certificate of Conformity

Junction box for EKL light

3/2-way Rocker Solenoid Valve for pneumatic systems

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

Direct-acting 3/2 way plunger valve

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Technical Documentation

Compact System NRGS 11-2 NRGS Original Installation Instructions English

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

APPLICATION OF SYSTEM 8

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Installation and Operating Instructions Magnetic Vibrator MR 1

MODULE LINE. Operating Instructions B.. Spring-applied single-disc brake module. Types: B B B B15

Transcription:

nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer! In order to guarantee the function and for your own safety, please read the enclosed operating instructions attentively, before starting installation. Should there still arise any question or queries, please contact nass magnet GmbH. Phone ++49 (0) 511 6746-0 Fax ++49 (0) 511 6746-222 e-mail vertrieb@nassmagnet.de Operating Instructions General Conditions We are not liable for any damage caused by non-observation of this information as well as in case of improper intervention regarding this device. Furthermore, warranty for the devices and accessories will become void. Please observe the information given in the present operating instructions as well as the application conditions and admissible data indicated on the imprints / type plates of the respective devices. The PTB approval exclusively covers solenoid operators with nass magnet armature assembly and with nass magnet solenoid coil. Follow the generally accepted technical rules when selecting and operating a unit. Take suitable measures to exclude unintentional activation or inadmissible impairment. Make sure not to detach pipes and valves of pressurized systems. Caution! Risk of injury! The solenoid s surface can get very hot during continuous operation. Installation After removing the packing, make sure that dirt cannot penetrate into the system. Before mounting the system, check that there is no dirt in the piping or the valve housing. When inserting the system, make sure that the flange O-ring will not be damaged. If coils are used in manifold assembly (directly side by side) pay attention to the minimum distance according the temperature class (see technical datas). Mounting is admissible in any position. Preferably the solenoid system has to point upwards. The solenoid coil can be locked in 45 steps. Tightening torque for fastening nut: 0.5 Nm Electrical connection with the integrated cable of the solenoid coil (wire ends suitable for screw terminals/clamps), in the hazardous area with approved explosion-protected equipment (e.g. terminal box with type of protection Increased Safety "e" according EN 50019).

If connecting the lead wires make ensure the wire ends of the leads are properly inserted to the electrical terminal. Connecting cable and wires should be free of sharp bends in order to avoid short circuits and interruptions. Before initial operation of the device make sure that the overall equipment or unit respectively meets the requirements of the EMC directive. At a ambient temperature from -40 C to -50 C the connecting cable must be laid stationary. Please order spare parts completely by indicating the identification number provided on the units (imprint / type plate). At installation and maintenance it is essential to keep to the concerning Ex standards, especially ENa60079-14 and EN 50281-1-2. The electrical installation has to be carried out by authorized personnel following additional relevant national regulations (in Germany VDE 0100). Each solenoid operator has to be protected by a fuse according to the rated (max. 3x rated accord. DIN 41571 or IEC 60127-2-1) resp. Motor protection switch with shortciruit and fast thermal tripping protection. The fuse can be accommodated in the associated device or must be added separately. The fuse voltage has to be equal or higher than the rated solenoid voltage. The shutdown capability has to be equal or higher than the max. assumed short-circuit at the installation point (usually 1500A). Valve-housing material: Casting alloy: Mg contents < 6% Synthetic material: according to EN 50014, surface resistance < 1 GΩ or surface area including solenoid coil surface limited to max. 20 cm² projected to all directions. Operation Admissible media are gas and liquids that do not affect the system and the sealing material contained therein. The outside surfaces of the solenoid should be free of contact with liquids or corrosives. The devices maximum operating pressure depends on the armature assembly or valve system used. Caution should be exercised to make sure the maximum operating pressure of 20 bar of the product is not exceeded. Do not strain the system by bending or torsion. Prevent the connecting cables and strands from being buckled in order to avoid short circuits and interruptions. Troubleshooting Check the cable connections, operating voltage and pressure. Should problem persist, remove pressure, disconnect from power supply. Defective explosion-proof devices must not be repaired, but must be replaced.

Certificate of Conformity Messrs. Nass Magnet GmbH, Hannover, declare and bear sole responsibility for the following EEx products to be in compliance with the safety standards: Solenoid operator 0516 00 to 0516 29 II 2G EEx ma II T4 IEC Ex m II T4 Solenoid operator 1216 00 to 1216 29 II 2D IP65 T130 C IP65 DIP A21 T130 C Solenoid operator 0516 30 to 0516 59 II 2G EEx ma II T5 IEC Ex m II T5 Solenoid operator 1216 30 to 1216 59 II 2D IP65 T95 C IP65 DIP A21 T95 C Solenoid operator 0516 60 to 0516 99 II 2G EEx ma II T6 IEC Ex m II T6 Solenoid operator 1216 60 to 1216 99 II 2D IP65 T80 C IP65 DIP A21 T80 C The Homologation Certificate and the Certificate of Conformity with the numbers: PTB 04 ATEX 2015 X and IECEx PTB 05.0009X issued by PTB (registration entity no. 010 is applicable for the solenoid operator. The solenoid operator is an encapsulated safe electrical work equipment group IIC, designed for application in atmospheres according to category 2G and 2D (temperature class and surface temperature as per imprint). The device, which is provided with the CE symbol, meets the following standards: EN 50014: 1997 IEC 60079-0: 2000 EN 60079-18: 2004 IEC 60079-18: 1992 EN 50281-1-1: 1999 IEC 61241-1-1: 1999 DIN EN 60529: 2000 DIN EN 61000-6-4: 2002 DIN EN 61000-6-2: 2002 DIN VDE 0580: 2000 Richtlinie 94/9/EG Electrical apparatus for potentially explosive atmospheres (General requirements) Electrical apparatus for explosive gas atmospheres (General requirements) Electrical apparatus for potentially explosive atmospheres (Encapsulation m) Electrical apparatus for explosive gas atmospheres (Encapsulation m) Electrical apparatus for use in the presence of combustible dust Electrical apparatus for use in the presence of combustible dust Degrees of Protection provided by Enclosures (IP Code) Electromagnetic Compatibility, Interference Emissions, Industrial Sector (met by additional circuitry measures) 1) Electromagnetic Compatibility, Interference Immunity Industrial Sector Electromagnetic Devices and components (General specifications) Equipment intended for use in potentially explosive atmospheres 1) Remark to the Electromagnetic Compatibility (emitted interferences): At the moment there are no regulations (standards) defining wire bounded interferences for DC operated devices. Newer power supply units suppreses interferences caused by switch off effects in the coil. In AC operated coils / solenoids a rectifier is internally inserted between winding and cable. Therefore at AC coils no inadmissibly interferences can appear. For DC operated units a shielded cable is required. Hannover 2007-01-10 Klaus Kirchheim General manager

Technical Data supply voltage tolerance +/- 10% nominal pressure according armature / valve system, max. 20 bar Temperature Class T4 Solenoid Operator IEC II 2G EEx ma II T4 II 2D IP65 T130 C Ex m II T4 IP65 DIP A21 T130 C Type 0516 00 0516 29 1216 00 1216 29 Current AC-operation 50 60Hz DC-operation, max. 20% ripple Ambient Temperature -Single assembly -Manifold assembly max. media temperature Manifold assembly min. distance Voltage U N 1 I N -50 C +60 C -50 C +60 C 80 C 80 C I 1 N [V] 6 815 4,9 4,1 1600 12 380 4,6 3,6 1000 471 5,6 4,6 1000 24 171 4,1 3,3 400 218 5,2 4,3 500 32 145 4,7 3,9 315 36 134 4,8 3,9 315 42 135 5,7 4,5 315 48 116 5,6 4,5 250 106 5,1 4,2 200 60 85 5,1 4,2 200 110 43 4,7 3,8 100 54 5,9 4,9 100 120 47 5,7 4,6 125 125 48 6,0 5 100 220 22 4,8 3,9 63 27 6,0 5 63 230 23 5,3 4,2 63 240 24 5,8 4,6 63 1) dimensioning maximum power at the thermal load limit 3) Each solenoid operator has to be protected by a fuse according to the rated (max. 3x rated accord. DIN 41571 or IEC 60127-2-1) resp. Motor protection switch with short-ciruit and fast thermal tripping protection. The fuse can be accommodated in the associated device or must be added separately. The fuse voltage has to be equal or higher than the rated solenoid voltage. The shutdown capability has to be equal or higher than the max. assumed short-circuit at the installation point (usually 1500A).

Temperature Class T5 Solenoid Operator IEC II 2G EEx ma II T5 II 2D IP65 T95 C Ex m II T5 IP65 DIP A21 T95 C Type 0516 30 0516 59 1216 30 1216 59 Current AC-operation 50 60Hz DC-operation, max. 20% ripple Ambient Temperature -Single assembly -Manifold assembly -50 C +40 C max. media temperature 80 C 80 C Manifold assembly min. distance Voltage U N [V] 1 I N I 1 N 6 531 3,2 3,0 1000 12 212 2,5 2,4 500 267 3,2 3,0 500 24 124 2,5 2,4 315 136 3,3 3,0 315 32 110 3,5 3,3 250 36 77 2,8 2,6 200 42 75 3,1 3,0 200 48 66 3,2 3,0 160 68 3,3 3,1 160 60 55 3,3 3,1 125 110 27 3,0 2,8 80 33 3,6 3,4 80 120 29 3,5 3,3 80 125 28 3,5 3,3 63 220 13 2,8 2,6 32 14 3,0 2,8 40 230 14 3,1 2,9 32 240 15 3,6 3,4 40 1) dimensioning maximum power at the thermal load limit 3) Each solenoid operator has to be protected by a fuse according to the rated (max. 3x rated accord. DIN 41571 or IEC 60127-2-1) resp. Motor protection switch with short-ciruit and fast thermal tripping protection. The fuse can be accommodated in the associated device or must be added separately. The fuse voltage has to be equal or higher than the rated solenoid voltage. The shutdown capability has to be equal or higher than the max. assumed short-circuit at the installation point (usually 1500A).

Temperature Class T6 Solenoid Operator IEC II 2G EEx ma II T6 II 2D IP65 T80 C Ex m II T6 IP65 DIP A21 T80 C Type 0516 60 0516 99 1216 60 1216 99 Current AC-operation 50 60Hz DC-operation, max. 20% ripple Ambient Temperature -Single assembly -Manifold assembly -50 C +40 C -50 C +40 C max. media temperature 70 C 70 C Manifold assembly min. distance 1 mm 2 mm Voltage U N [V] 1 I N I 1 N 6 435 2,6 2,5 1000 12 158 1,9 1,8 400 214 2,6 2,4 500 24 80 1,9 1,8 200 109 2,6 2,5 250 32 82 2,6 2,5 200 36 60 2,2 2,0 160 42 56 2,3 2,2 160 48 50 2,4 2,3 125 54 2,6 2,5 125 60 44 2,6 2,5 100 110 22 2,4 2,3 63 24 2,6 2,5 63 120 18 2,2 2,0 50 125 21 2,6 2,4 50 220 11 2,4 2,3 32 12 2,6 2,5 32 230 9 2,1 1,9 32 240 10 2,4 2,3 32 1) dimensioning maximum power at the thermal load limit 3) Each solenoid operator has to be protected by a fuse according to the rated (max. 3x rated accord. DIN 41571 or IEC 60127-2-1) resp. Motor protection switch with short-ciruit and fast thermal tripping protection. The fuse can be accommodated in the associated device or must be added separately. The fuse voltage has to be equal or higher than the rated solenoid voltage. The shutdown capability has to be equal or higher than the max. assumed short-circuit at the installation point (usually 1500A).