CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

Similar documents
EZ-IN Series Turbine Flowmeter

True-Cut RP Receptacle

Clif Mock. CD20 (12VDC) Sampler Drive. User Manual. Manual No A

Liquid Turbine Flowmeter

TMCo,, Inc. The Measurement Company

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

INSTALL GUIDE Ford F L

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CD-20A Sample Probe Controller User Manual

INSTALL GUIDE Dodge/RAM 5.7L HEMI

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

DeZURIK KUL KNIFE GATE VALVES

INSTALL GUIDE Silverado/Sierra L/6.2L

DeZURIK 2 20" BOS BUTTERFLY VALVES

MaxLite StaxMax LED Flood Lights

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

ECONOMAIR SERIES CYLINDERS

Guardian Taper Grid Shaft Coupling

Straight-Bore Clutch LSCC-32, 44, 54

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

HSIV PLOW OPERATOR S MANUAL

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

TBM Series 3-Way Ball Valve

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Guardian Steel Gear Shaft Coupling

Guardian FBA Flywheel Coupling

Guardian NV Flywheel Coupling

APCO CSV-1600 SURGE CHECK VALVE

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

INSTALLATION INSTRUCTIONS

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Operating and Installation Instructions

TONS. Before each shift: Before operating: Before initial operation of hoist:

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

Installation and Maintenance Manual for the Lock Down Hatch for the Gauge Hatch Model L61T

TECHNICAL SERVICE MANUAL

PRODUCT OBSOLETED 4Q16

Guardian HH Shaft Coupling

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Installation and Operating Instruction for Complete Freewheels FRS, FRSG, and FRZ. E e Anderson Place Telephone

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

6701 KNIFE GATE VALVES

INSTALL GUIDE Jeep Wrangler JK 3.6L V6

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

AD-7. Instruction Manual. Thermal Indicating Ammeter HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

RB-90 RUPTURE DISK, RB-7R, RB-7FF AND RB-7FS SAFETY HEAD INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

CRD610 Automatic Fitting Inserter

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

TITAN 13 x 2½ BRAKES DUO-SERVO AND FREE BACKING

ENTERTAINMENT. BGV-D8+ Supplement to Manual # Tonne to 1.3 Tonne 250 kg to 1300 kg (REV. AA) E627NH

AWE Track Edition Exhaust System Ford Focus ST 2.0T. AWE website here

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Guardian FH Flywheel Coupling

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

MetroPrime 22MPC Self-Priming Centrifugal Pump

FIGURE 310A & 311A 3-PIECE BALL VALVE

DODGE CUMMINS Air-Boss CR Intake Plenum

Installation, Operation, and Maintenance Manual

ASSEMBLY OF TROLLEY TO HOIST

DEMCO Resilient-Seated Butterfly Valve

User Manual SH Slag Removal Tool for use on laser cutting machines with minimum 1.25 between slats

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves

TECHNICAL SERVICE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

RPD SERIES HEAVY AND SEVERE DUTY SNOW PLOW

RVT SERIES HEAVY DUTY TRIPPING SNOW PLOW

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Instructions and Parts List 3M-Matic P/N Infeed/Exit Conveyor Attachment, 1.2 Meter

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

INTRODUCTION INSTALLATION

Power Float Manifold. Installation and Operations Manual Module 11A

Operation and Maintenance Manual. ACME SCREW Electric Cylinders by Joyce Dayton. Standard, Motor mount, and ComDRIVE style

HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS HUCK FASTENERS INSTRUCTION MANUAL

DAP-625S and DAP-875S

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

MODEL 5120 Tire Repair Station

C200 1/2" - 2" Remote Squeeze Off Tool

PREMIER, MARINE, & STANDARD

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

Single Post Caliper Brake VC500

Installation and Maintenance Manual for the Lock Down Hatch for the Gauge Hatch Model L61T

Model 8309WC Barrier Free Shower & Eye/Face Wash

Air Chain Hoist. Follow all instructions and warnings for. Capacities. 250 lbs (113 kg) 300 lbs (136 kg) 500 lbs (226 kg) 600 lbs (272 kg)

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Transcription:

CLIF MOCK TM Model 5030 Orifice Fitting User Manual Manual No. 25165003, Rev. B

2007 Cameron International Corporation ( Cameron ). All information contained in this publication is confidential and proprietary property of Cameron. Any reproduction or use of these instructions, drawings, or photographs without the express written permission of an officer of Cameron is forbidden. All Rights Reserved. Printed in the United States of America. Manual No. 25165003, Rev. B January 2007

Table of Contents Section 1 Introduction...5 Principle of Operation...5 Components...5 Section 2 Installation...9 Preparation...9 Orifice Fitting Installation...10 Section 3 Installing and Removing Orifice Plates...11 Removing an Orifice Plate...11 Inserting an Orifice Plate...11 Section 4 Maintenance...13 Spare Parts...14 January 2007 iii

iv January 2007

Section 1 Introduction Principle of Operation The Clif Mock Model 5030 Orifice Fitting secures an orifice plate in the proper position for measuring flow within a pipe or tube. When correctly positioned in the orifice fitting, an orifice plate will produce a differential pressure by constricting the flow of fluid passing through it. The differential pressure is measured across the plate through two taps located on the fitting near the constriction. The single chamber design allows the user to inspect and replace orifice plates without removing the fitting from the flow line. Components Within the Model 5030 Orifice Fitting is an assembly that includes the sealing bar and orifice plate carrier (Figure 1.1). This assembly allows maintenance personnel to remove the sealing bar, orifice plate carrier, the orifice plate, and plate seal in a single step. The Model 5030 Orifice Fitting is a weld-by-weld fitting available in 2 in. and 3 in. diameters and in two pipe thicknesses (Schedule 40 and Schedule 80). The orifice fitting is rated for ANSI Class 600 with a maximum working pressure of 1480 psi at 100 F per ASME B16.5. Warning! Always relieve system pressure before attempting to disassemble the orifice fitting. The orifice plate fitted with a seal is positioned inside the carrier, which is attached to the sealing bar by two cap screws. To remove the carrier/sealing bar assembly, the user simply loosens the four clamping screws at the top of the fitting, slides the clamping bar out, and lifts the assembly from the body of the orifice fitting. Dimensions for a 2-in. orifice fitting are shown in Figures 1.2 and 1.3. Dimensions for a 3-in. orifice fitting are shown in Figures 1.4 and 1.5. January 2007 5

Figure 1.1 Nomenclature for the Model 5030 single-chamber orifice fitting 6 January 2007

Figure 1.2 Dimensions for a 2-in. orifice fitting (flow line view) Figure 1.3 Dimensions for a 2-in. orifice fitting (side view) January 2007 7

Figure 1.4 Dimensions for a 3-in. orifice fitting (flow line view) Figure 1.5 Dimensions for a 3-in. orifice fitting (side view) 8 January 2007

Section 2 Installation Preparation Before installing the fitting into the line, perform the following steps: 1. Clean piping of all foreign material such as welding chips, scale, oil, grease, and dirt. 2. Remove all foreign matter such as scale, oil, grease, and dirt from the fitting line connections and internal cavities of the fitting. 3. Record the fitting's plate data for future reference. Always provide the serial number and model number of the fitting when ordering spare parts. Figure 2.1 Data plate showing serial number and model number January 2007 9

4. Verify that the piping system in which the orifice fitting will be installed has been adequately designed with respect to the following: Internal/external pressure Ambient and operational temperatures Static pressure in operating and test conditions Corrosion, erosion, fatigue, etc. Fluid decomposition Loading from traffic, wind and earth Reaction forces and moments resulting from supports, attachments, piping, etc. Orifice Fitting Installation Warning! The orifice fitting may contain fluid under high pressure. Failure to comply with the instructions in this document can result in serious injury or death. The Model 5030 Orifice Fitting is an important part of an orifice metering system. To complete the unit, a meter tube must be attached. If the fitting is received without a meter tube, see code AGA-3-1985 for details. Before installing the meter tube containing the orifice fitting, perform the following steps: 1. Clean the meter tube interior as well as the piping sections where the meter tube will be installed. 2. Remove all foreign materials such as welding debris, scale, oil, grease or dirt. 3. If end flanges are used, select and install the proper gaskets and tighten all bolting to the required tightness. If welded connections are used, use proper procedures for the materials being joined. Warning! The gasket seal, sealing bar, and clamping bar must be installed so that a pressure barrier is created between the line pressure and atmospheric pressure. Failure to properly install these components can result in serious injury or death. 4. After the meter tube is in place and all connections are made and any holes plugged, pressure-test the meter tube as follows: a. Tighten the orifice fitting clamping bar screws to 40 ft-lb of torque. b. Hydrostatically pressure test in accordance with applicable piping code ASME B31.3. Before initiating the test, verify that there is no orifice plate in the fitting. c. Check for leaks at the sealing bar gasket and at all threaded connections on the orifice fitting. 10 January 2007

Section 3 Installing and Removing Orifice Plates The Model 5030 Orifice Fitting design allows an operator to install or remove the orifice plate while minimizing line shutdown time. Within the orifice fitting is an assembly that includes the sealing bar and orifice plate carrier. This sealing bar/orifice plate carrier assembly allows maintenance personnel to remove the sealing bar, orifice plate, and plate seal at one time. The design of the Model 5030 Orifice Fitting prevents spillage in liquid service applications. Removing an Orifice Plate 1. Depressurize or shut in the line supporting the orifice fitting. 2. Once pressure in the plate holder is reduced to ambient pressure, remove the sealing bar/orifice plate carrier assembly, containing the orifice plate, from the fitting. 3. Loosen the fasteners on the clamping bar two turns. 4. Lightly tap the sealing bar to break the gasket seal. 5. Slide out the clamping bar. 6. Lift out the sealing bar/orifice plate carrier from the orifice fitting body. 7. Remove the sealing bar gasket. 8. Remove the orifice plate and orifice plate seal from the sealing bar/orifice plate carrier. 9. Remove the orifice plate seal from the orifice plate. Inserting an Orifice Plate To insert an orifice plate into the orifice fitting without removing the fitting from the line, perform the following steps. 1. Remove the sealing bar and clamping bar from the body. 2. Install a new sealing bar gasket onto the orifice fitting body. 3. Install a new orifice seal onto the orifice plate. 4. Install the orifice plate and seal assembly into the plate carrier, taking into account the flow direction of the line. This can be done using the dowel pin located in the sealing bar as a reference. January 2007 11

Caution! Failure to install the orifice plate and orifice gasket assembly in a direction properly oriented with the direction of flow will result in measurement error and a possible loss of revenue. 5. Lower the plate carrier assembly into the orifice fitting, while aligning the dowel pin hole with the dowel pin, until the sealing bar/plate holder comes in full contact with the sealing bar gasket. 6. Install the clamping bar. 7. Tighten each of the clamping bar fasteners to 40 ft-lb of torque. The Model 5030 Orifice Fitting is now ready for final pressurization and operation. 12 January 2007

Section 4 Maintenance Under normal measurement conditions, the Model 5030 Orifice Fitting will require no maintenance. However, Cameron recommends a periodic inspection of the orifice fitting at an interval established by the measurement supervisor. The inspection should include a check of the plate holder for vandalism, or other inadvertent damage and well as a check for tightness of fasteners and connectors to ensure that the corrosion and tolerance dimensions of the fitting are not exceeded. January 2007 13

Spare Parts Tables 4.1 though 4.4 provide recommended spare parts for 2 in. and 3 in. fittings in Schedule 40 and Schedule 80 pipe. Important Always provide the serial number and model number of the fitting when ordering spare parts. Table 4.1 2-in. Model 5030 Fitting. Schedule 40, Weld-by-Weld (Part No. 50306000440) Qty. Part No. Description Notes 1 50306000442 Body, Mach., 2-in. Schedule 40, Weld-by- Weld 1 50316000438 Pin, Sealing Bar Locator 1 50316000439 Pin, Carrier Alignment 1 50316000444 Carrier, Mach, 2 Orifice Fitting 1 50316000445 Bar, Clamping 1 50316000446 Bar, Sealing 1 50316000447 Gasket, Sealing Bar 1 9910100 Seal Ring, Nitrile, 2, Schedule 40 1 TBD 2-in. Universal Orifice Plate 2 50025400759 Rivet 2 50316000437 Bolt, Hex HD, 3/8-16 x 1 SS 4 50316000448 Screw, Clamping, ½-13 x 1 ¼ SQ HD Half-Dog 2 50316000465 Washer, Split Lock, 3/8 SS 3 0199-0192C Plug, Pipe, ½ MNPT ST Other materials available on request. See Orifice Plates data sheet at www.c-a-m.com/flo. See Orifice Plate data sheet at www.c-a-m.com/flo. Common to all fittings For information on orifice plates, see the Orifice Plates and Orifice Plate Sealing Units data sheet on the Cameron (Measurement Systems Division) website, www.c-a-m.com/flo. 14 January 2007

Table 4.2 2-in. Model 5030 Fitting, Schedule 80, Weld-by-Weld (Part No. 50306000461) Qty. Part No. Description Notes 1 50306000459 Body, Mach., 2-in. Schedule 80, Weld-by- Weld 1 50316000438 Pin, Sealing Bar Locator 1 50316000439 Pin, Carrier Alignment 1 50316000444 Carrier, Mach, 2 Orifice Fitting 1 50316000445 Bar, Clamping 1 50316000446 Bar, Sealing 1 50316000447 Gasket, Sealing Bar 1 9910101 Seal Ring, Nitrile, 2, Schedule 80 1 TBD 2-in. Universal Orifice Plate 2 50025400759 Rivet 2 50316000437 Bolt, Hex HD, 3/8-16 x 1 SS 4 50316000448 Screw, ½-13 x 1 ¼ SQ HD Half-Dog 2 50316000465 Washer, Split Lock, 3/8 SS 3 0199-0192C Plug, Pipe, ½ MNPT ST Other materials available on request. See Orifice Plates data sheet at www.ca-m.com/flo. See Orifice Plates data sheet at www.c-a-m.com/flo. Common to all fittings For information on orifice plates, see the Orifice Plates and Orifice Plate Sealing Units data sheet on the Cameron (Measurement Systems Division) website, www.c-a-m.com/flo. January 2007 15

Table 4.3 3-in. Model 5030 Fitting, Schedule 40, Weld-by-Weld (Part No. 50306000450) Qty. Part No. Description Notes 1 50306000452 Body, Mach., 3-in. Schedule 40, Weld-by- Weld 1 50316000438 Pin, Sealing Bar Locator 1 50316000439 Pin, Carrier Alignment 1 50316000454 Carrier, Mach, 3 Orifice Fitting 1 50316000455 Bar, Clamping 1 50316000456 Bar, Sealing 1 50316000457 Gasket, Sealing Bar 1 9910102 Seal Ring, Nitrile, 3, Schedule 40 1 TBD 3-in. Universal Orifice Plate 2 50025400759 Rivet 2 50316000437 Bolt, Hex HD, 3/8-16 x 1 SS 4 50316000448 Screw, ½-13 x 1 ¼ SQ HD Half-Dog 2 50316000465 Washer, Split Lock, 3/8 SS 3 0199-0192C Plug, Pipe, ½ MNPT ST Other materials available on request. See Orifice Plates data sheet at www.c-a-m.com/flo. See Orifice Plate data sheet at www.c-a-m.com/flo. Common to all fittings For information on orifice plates, see the Orifice Plates and Orifice Plate Sealing Units data sheet on the Cameron (Measurement Systems Division) website, www.c-a-m.com/flo. 16 January 2007

Table 4.4 3-in. Model 5030 Fitting, Schedule 80, Weld-by-Weld (Part No. 50306000462) Qty. Part No. Description Notes 1 50306000460 Body, Mach., 3-in. Schedule 80, Weld-by- Weld 1 50316000438 Pin, Sealing Bar Locator 1 50316000439 Pin, Carrier Alignment 1 50316000454 Carrier, Mach, 3 Orifice Fitting 1 50316000455 Bar, Clamping 1 50316000456 Bar, Sealing 1 50316000457 Gasket, Sealing Bar 1 9910103 Seal Ring, Nitrile, 3, Schedule 80 1 TBD 3-in. Universal Orifice Plate 2 50025400759 Rivet 2 50316000437 Bolt, Hex HD, 3/8-16 x 1 SS 4 50316000448 Screw, ½-13 x 1 ¼ SQ HD Half-Dog 2 50316000465 Washer, Split Lock, 3/8 SS 3 0199-0192C Plug, Pipe, ½ MNPT ST Other materials available on request. See Orifice Plates data sheet at www.c-a-m.com/flo. See Orifice Plate data sheet at www.c-a-m.com/flo. Common to all fittings For information on orifice plates, see the Orifice Plates and Orifice Plate Sealing Units data sheet on the Cameron (Measurement Systems Division) website, www.c-a-m.com/flo. January 2007 17

18 January 2007

WARRANTY - LIMITATION OF LIABILITY: Seller warrants only title to the products, software, supplies and materials and that, except as to software, the same are free from defects in workmanship and materials for a period of one (1) year from the date of delivery. Seller does not warranty that software is free from error or that software will run in an uninterrupted fashion. Seller provides all software "as is". THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE WHICH EXTEND BEYOND THOSE STATED IN THE IMMEDIATELY PRECEDING SENTENCE. Seller's liability and Buyer's exclusive remedy in any case of action (whether in contract, tort, breach of warranty or otherwise) arising out of the sale or use of any products, software, supplies, or materials is expressly limited to the replacement of such products, software, supplies, or materials on their return to Seller or, at Seller's option, to the allowance to the customer of credit for the cost of such items. In no event shall Seller be liable for special, incidental, indirect, punitive or consequential damages. Seller does not warrant in any way products, software, supplies and materials not manufactured by Seller, and such will be sold only with the warranties that are given by the manufacturer thereof. Seller will pass only through to its purchaser of such items the warranty granted to it by the manufacturer.