RG6 TLC F Hands-On. Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168)

Similar documents
Tools & Supplies. Phillips. Combo Head. Slotted. Square. Double Ended Customer Assistance

Termination Procedure for Subminiature SolderTacts Contacts for Coaxial Cable: D & D D & D

Bel Stewart Connector

Wiring Assembly Instructions Section 5 P/N CASS P/N 1899AS RG316 P/N CASS P/N 1899AS RG316

MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable

CASS Interface System Parts Section 1

Termination Procedure for 723 Series SolderTacts Contacts for Coaxial Cable: D , D

Voice/Data/ Video Tools

Backside License Plate Mount for Jeep JK Wrangler

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Assembly Instructions-C12 Amphenol Triax BNC, 180 Polarity

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Cold Shrink QS T Trifurcating Transition Splice Kit

ET-PWR-END-KIT Installation Instructions (part #JSR00)

HVS S 15kV Class

1 GENERAL INFORMATION

Assembly, Installation, and Removal of Contacts and modules

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

80703 & Backside License Plate Mount for Jeep JK Wrangler (80707) & 10+ (80703)

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

American Standard ProAx Triaxial Camera Connectors Installation Instructions

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

UES-LL End Termination Kit

ELB ELB

Terminal Can Wrench Discrete Connector Presser Plier No. 3 Square Tipped Driver Booth Wrench Security Tool

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Step #1 From your spool of 18 gauge primary wire, cut between 11 and 21 three inch strips of wire. You will only need 11 for the ROV, but it is good t

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

INSTALLATION INSTRUCTIONS RATTLER STEEL RUNNING BOARDS FORD TRANSIT VAN (FULL SIZE)

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

General characteristics and technical data Series MCS

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

JUL 17 Rev M

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

DFG PC200e Coil Punch & Bind Machine

354 CHAPTER EIGHT WATER PUMP

QUICKTERM TERMINATION KIT

Bob's Shop Notes: Alternatives to RG58 in Lightspeed Ignition Wiring

6 Gauge Box Set IS0332

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

3M Cold Shrink Splice Kit QS-III 5536A

MR Gradient Cable Field Termination Training

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Go-ped ESR750 / ESR750EX Rear Brake Installation Instructions

INSTALLATION INSTRUCTION PEM1121ENG ENGLISH

CS Fiber Optic Splice Case. Instruction

INSTALLATION INSTRUCTIONS

Installation Instructions

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

2013 RT / 2014RT / 2015 RT - Shock Spring Adjuster Installation Instructions

Crimp & Cleave Termination Instructions

DFG EC1000 Heavy Duty Coil Punch/Bind Machine

WARNING. Important Notice

VITALink Taped Splice Pigtail Crimp

Application Tooling Specification Sheet

RSK Connectors and Installation Tools

C Power Connection Kit

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

Crimp & Cleave Termination Instructions

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

GENUINE PARTS INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Cabling Instructions NOνA Project Written By: Dale Mudd September 21 st, 2010

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

INSTALLATION GUIDES DekaFlex Connectors DEKAFLEX MC-HL CONNECTOR INSTALLATION GUIDE FOR HAZARDOUS LOCATIONS

Application Tooling Specification Sheet

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Installation Instructions

Wire Piercing Guide Heavy Duty Circuit Tester 6, 12, 24 Volt Professional Circuit Tester 6, 12 Volt

6 Gauge Box Set with Programmable Speedometer. Made in the USA. Caution. Speedometer Parts. Tachometer Parts. Fuel Level Gauge Parts.

LMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS

QT-III Cold Shrink Silicone Rubber

Application Tooling Specification Sheet

Written By: Walter Galan

INSTALLATION INSTRUCTIONS

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Continuous Cord Loop Designer Series Roller Shades

Application Tooling Specification Sheet

#TL T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS

Around the cable. Stripping.... convincing solutions

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

CI 3000 Coil Inserter

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Application Tooling Specification Sheet

Transcription:

RG6 TLC F Hands-On Materials Needed RG6 regular/dual coax cable Adjustable prep tool (stripper) (45-526) RG6 F TLC connector (85-168)

Prep the RG6 Tool directions Verify grey cartridge is in the front (nose) position of the 45-605. Note the location of the wall side of the cartridge. Remove and flip cartridge if needed. Squeeze handle to open the jaw. Place the coax into the grey cartridge flush against the wall of the cartridge. Not on top of wall. Quickly rotate tool clockwise 4 times around cable. No need to spin in the opposite direction. Pinch tool nose and pull cable from tool. Remove slugs from tool if necessary. Wall UTP/STP side Flush against wall COAX Fixed depth and width blades. Auto adjusts for 59/6/6Q and plenum coax. Notched blade now handles 59 plenum. Replaceable blades available. Provides standard ¼ x ¼ prep. 45-605 PrepPro Tool

Inspect & Dress the RG6 Same procedure as 6 F Crimp To do checklist: No braids touching or wrapped around the center conductor. Braid strands all cut flush with dielectric edge. Dielectric cut flush 90. No excessive remnants/residue on the center conductor. No excessive scoring of the center conductor near the dielectric. Ensure braids are not severed/scored near the jacket cut and will become loose. Center conductor is straight with a well formed tip. Outer jacket cut is clean and flush. Gently fold back the braiding against the jacket. Do not disrupt, remove, or fold the foil layer. Leave it flat against the dielectric. Keep the braiding evenly distributed around the jacket. Fold back

TLC Tool-less F Compression No compression tool required. Just prep and attach connector. Designed for indoor connections. Fast, easy, and inexpensive option for a reliable connection. Works kind of like a Chinese finger trap device. Does not pierce jacket with teeth Sliding post captures the cable with a 360 seal. No connector or cable dielectric deformation. Permanent connection, it is not re-useable. Also available in RG6 Quad TLC: Tool-Less Compression saves you Time, Labor, and Cost!

Place TLC connector on RG6 cable Assembly directions Take the RG6 F TLC connector and center it over the cable. Align and insert the center conductor from the bottom of the connector through the smaller inner hole (mandrel). Make sure the dielectric is centered in the mandrel opening. Push or slightly twist the connector back and forth until the white dielectric is flush with the bottom of the nut of the connector. Notice the mandrel moves in this connector. The conductor tip should extend ¼ beyond the top lip of the hex nut. Pull connector body FORWARD to help seat the post to the base of the nut. And expose nut threads. The conductor will now be standard length. Give one last inspection to ensure no strands are in contact with the center pin. Attaching the TLC connector to a device will seat the post fully to the base of the nut if the pull back alone did not do it. Use of an F-Connector tool to tighten the TLC to a device is optional. The tool (35-046) will help ensure that the post is fully recessed, providing good electrical continuity between the nut and the post. Because the TLC has a sliding post design, the center conductor will initially stick out farther than crimp or compression connectors. When attached to a device, the post slides back to a recessed position, and the conductor will be the standard length. Properly Seated Connector SHARP Completed Termination

IDEAL TLC F Connector Termination Instructions 1) Use coax stripper to strip cable so ¼ of conductor and ¼ of braiding are exposed. (45-605 shown) 2) Fold back braiding, make sure no braids are touching the center conductor. Straighten conductor if needed. Do not remove foil that is attached to the white dielectric (RG6/6Q) 3) Center cable over back end of connector and push connector on to cable until fully seated. Connector post will slide. This is normal. Threads hidden 4) Cable is fully seated when white dielectric is flush with the bottom of the nut. Threads exposed 5) Holding the connector, pull back on cable to expose threaded rings and lock connector into place. No tool is required. 6) Verify threaded rings are exposed and dielectric is at/near connector nut bottom. Connect to device. RG6 coax is used in this example. General preparation instructions are the same for RG6 Quad TLC IDEAL F connectors. When working with RG6 Quad cable, the outer foil can be removed, and the inner braiding should be folded down. This makes it easier to push the connector on to the cable.