PRISMALUME ENCLOSED HL /03

Similar documents
ENDURALUME HL /02

Prismalume. Enclosed HOLOPHANE

Prismpack. V Enclosed HOLOPHANE

PRISMALUME HL-755 8/02

CRYSTALGLO. Holophane s potted ballast provides good thermal dissipation and sound absorption, for long life and quiet operation.

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Standard Grade 14 Inch Reflector. Ordering Information

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Applications. Standard Materials

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Applications. Standard Materials. Certifications and Compliances

HOLOPHANE Outdoor Lighting

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Phuzion LED High Bay Wet location listed

Lighting: Explosionproof Area HID. Applications. Standard Materials

PhuzionL Large LED High Bay

AFL FLOODLIGHT SERIES

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

DECORATIVE. Tear Drop Series

N2MV Series W Non-metallic

Applications. Standard Materials. Certifications and Compliances

Applications. Illustrated Features

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

ELG CosmoPolis / MasterColor Elite HID Series Element Enclosed Glass High Bay, watt

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

ELA Low Wattage HID Series Element Acrylic High Bay, W HID


SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

PGL350P W PS Wallpack

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Phuzion Crane Light LED High Bay

Overall Dimensions. Specifications

Perimaliter Wallpacks

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

S43X. elliptipar high lumen. uplights S432 S431 S433 S434 PRODUCT

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

HBL HIGH-BAY INDUSTRIAL LUMINAIRE

now available in 1000w HID

CONTENTS LITHONIA INDOOR HID

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Areamaster LED Flood/High Bay Luminaires

PROJECT INFORMATION. Catalog No.

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

C A M B E RTM PATENTS PENDING

The ideal complement for commercial and retail spaces where users will appreciate classic interpretations of style and elegance. Kaleidoscope Series

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Predator Medium Floodlight Wet Location

DESCRIPTION & APPLICATION

IMPORTANT SAFETY INSTRUCTIONS

ORDERING INFORMATION: 120 Volts (120)

Laredo Decorative Wallpack Family

DELTA RAIL SYSTEM SYMMETRIC OPTICAL SYSTEM STANDARD SPECIFICATIONS DR 1 320MH-PS. 29,700 36,000 40, , mm 400MH 400MH-PS 1000MH-BT37 DR 2

TORNADOTM BOLLARD PATENTS PENDING

SXPJ SERIES S X azz.com/rigalite

ELMGR Compact Fluorescent Series Element Rodded Metal over Glass (glass lined) High Bay

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Design Standard. Purpose: Design Standard:

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

Perimaliter Wallpacks

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Example: RBX15L840-UNV-WT ARR22L. Family Lumens Color Temperature Voltage Finish Options Optics

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

Overall Dimensions. Specifications

MetroVue HOLOPHANE THE

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

Laredo - Decorative Wallpack Family

Kaleidoshade 2 Series

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

elliptipar S43X high-lumen

MAR SERIES Fluorescent Lighting for Hazardous Locations

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

Options. Pole and Arm. Suitable for wet locations

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

LED DockLight. Sustainable lighting with powerful output. UL listed for wet locations. Standard 5 year warranty

PEERLESS BLOWERS DIRECT DRIVE BLOWERS

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

Transcription:

The Prismalume Enclosed fixture is the perfect solution for a variety of industrial areas where an enclosed fixture is essential. Chemical plants, textile mills, processing plants and gymnasiums are a few typical applications for the Prismalume Enclosed fixture. Prismatic glass reflectors with tempered glass closures ensure a long lasting, durable lighting fixture. A full range of wattages and lamp types coupled with an assortment of optical distributions, results in an energy efficient design with superior performance. The Prismalume Enclosed fixture also meets safety requirements for containing nonpassive lamp failure. HL-1130 4/03

Choice of mountings P-Pendant Q-Quick disconnect power hanger N-Non-disconnect changer power Choice of lamps and wattages Metal halide 175, 250, 320, 350, 400, 750, 1000W HPS 150, 250, 400, 750, 1000W Approved for most applications Damp location UL listed CSA listed Choice of factory set optical distributions Choice of tempered bottom enclosures Thermal shock resistant prismatic glass reflectors Die cast aluminum ballast housing Thermoset white polyester powder paint Industrial Two critical criteria when designing lighting for an industrial area are safety and performance. The Prismalume Enclosed fixture comes standard with safety features such as tool-less entry into the optics and it also meets the safety requirements for containing non-passive lamp failures. Our standard prismatic glass reflectors provide superior vertical and horizontal illumination on the work plane. This results in a uniformly lit area utilizing a small quantity of fixtures. 2 Retail Consumers are paying more attention to ambiance and are using this as a criteria on where to spend their time and money. Therefore, retail areas need to supply the correct goods and present it in an appealing manner. The Prismalume fixture s stylish appearance and uniform light distribution provide the retailer with good, general lighting.

ASSEMBLY AREAS INSPECTION AREAS PRODUCTION AREAS WAREHOUSES PAPER MILLS EXPOSITION HALLS SUPER MALLS Gyms, Field Houses Another nice feature of the Prismalume Enclosed fixture is its ruggedness. It can withstand the impact of sport equipment without compromising the fixture's integrity. Steel rods connect the optics to the ballast housing and our polyester powder paint is a great chlorine deterrent. No shadows, no glare, no worry - your athletes can concentrate on their performance, not ours. Efficient lighting of the visual environment Prismalume reflectors provide maximum efficiency for flexibility of design. The unique prismatic glass reflector system coupled with a wide selection of HID lamps and wattages means an extensive choice of distributions is available to tailor your lighting design to the application. The unique balance of uplight and downlight from Prismalume luminaires provides outstanding lighting solutions for countless applications. 3

Ease of Maintenance The combination of the glass reflector and enclosed optics minimizes the dirt depreciation of the fixture. A simple wiping of the smooth inner surface of the glass reflector and the top and bottom surface of the tempered glass door will restore efficiency to near initial output. Stainless steel latches on the hinge door enclosure provide easy tool-less access to the lamp and a tight gasket seal. Ease of Installation The ballast assembly installs quickly with the pendant mounting plate which threads onto DN20NPT (.75 ) conduit and easily slides into the ballast key way. The optional quick disconnect box or thru-way wiring box can be ceiling mounted or threaded onto DN20NPT (.75 ) conduit. The integral hinge design allows for the simple attachment of the ballast assembly. Stainless steel latches then allow quick tool-less attachment of the optical assembly to ballast assembly. 150-400W ballast shown 1 2 3 4 5 6 1 Optional Quick Disconnect Hanger for application flexibility and disconnect under load capability. 2 Die cast aluminum alloy ballast and optical support housing. Pretreated and coated with electrostatically deposited thermo-set polyester white paint. 3 Non-deteriorating fiberglass gasket allows the fixture to breath. 4 Zinc plated steel hinge and stainless steel latch. 5 Prismatic, borosilicate glass reflector allows 15-20% uplight, reducing the cavern effect, and reduces glare. 6 Non-obstructing gasketed, hinged door with tempered glass enclosure for higher efficiencies. Prismatic Glass Optics Thermal-shock resistant Endural prismatic glass reflectors. Five reflectors offer choice of distributions to efficiently meet design requirements. Glass reflector will not pit or corrode in normal industrial use. Prismatic glass reflectors minimize brightness from inner surface. Door enclosure does not obstruct the reflector opening for maximum efficiency. Prismatic bottom enclosure 4

400W Mag. Reg., 750, 1000W Percent of rated life 160 140 120 100 80 60 25 Rated Luminaires 4 Rated Luminaires 55 Rated Luminaires 65 Rated Luminaires 40 25 3 35 4 45 5 55 65 7 75 Ambient temperature ( C) vs. Rated life for integrally ballasted luminaires Ballast assembly Die cast aluminum housing combines corrosion resistance with mechanical strength to withstand harsh industrial environments. Quick install pendant mounting plate threads onto DN20NPT (.75 ) conduit, and housing slides onto the keyed plate. Seven stage pre-treatment of the housing is followed by a sprayed on polyester powder paint, cured and baked on at 218 C. This exceeds ASTM standard practice for hardness, humidity, impact and salt spray resistance to prevent cross hatch creep, fading, cracking and other environmental related deterioration. UL listed - 55 C damp location as standard. Optional 65 C available. Vibration tested at 0.5g to withstand conditions in harsh environments. A variety of malleable iron hooks and loops to accommodate various mounting requirements. Holophane manufactured, high power factor (over 90%) copper wound ballasts, 100% tested and matched to capacitors provide full lamp output while consuming less energy. Optional quick disconnect or thru-way wiring are UL and CUL listed. Thru-way box can carry up to five #10 ga. wires with 24 amps per wire. Remote ballast shown 5

31 35 39 40 50 A choice of light distributions Prismalume Enclosed (PE) Metal Halide High Pressure Sodium Spacing Pulse Start criteria 175MH 400MH 250MH/PM/320PM 350PM/400PM 150HP 250HP 400HP Clear Coated Clear Coated Clear Coated Clear Coated Clear Clear Clear 0.6 E40 P40 E40 M39 M39 0.7 M39 J40 0.8 G40 E40 P40 H39 D39 E40 E35 0.9 D39 D39 P39 D39 G40 S40 S40 C40 C40 E39 S40 E35 P40 1.0 S40 S40 M31 B31 E39 H39 B35 B35 D58 D58 G31 B31 E39 B58 D31 D31 B31 1.1 H39 H39 B35 B58 E39 B35 B31 G35 P39 M35 B58 P40 A58 B58 1.2 M31 M31 J50 A58 M31 N58 A35 M35 G35 M35 M35 J50 M35 T50 J50 J50 U50 1.3 A58 A35 C35 A58 D31 D31 T50 N35 C58 H39 A35 E18 E18 U50 1.4 P18 C35 N58 A35 N58 M31 D31 G31 Z35 H39 M18 1.5 N58 M18 Z31 N35 N35 D31 G31 N35 H58 E18 C31 J18 Z31 M35 1.6 H31 E18 C31 H31 H31 P18 P18 S31 G31 N35 M35 1.7 P18 S31 G31 J31 H31 J18 1.8 H58 J18 S31 S31 U31 C31 J31 S31 1.9 U31 C31 S18 H31 H31 2.0 U31 U31 Reflector Catalog Number Matrix 6

Reflector Catalog Number Matrix Prismalume Enclosed (EP/EGH) Spacing Metal Halide Super Metal Halide High Pressure Sodium criteria 175W 250W 400W 750W 1000W 175W 250W 400W 1000W 250W 400W 750W 1000W CL CTD CL CTD CL CTD CL CL CTD CL CTD CL CTD CL CTD CL CTD CL DIF CL DIF CL CL 0.7 E40 0.8 E40 Z40 0.9 E40 H50/ G40 P40 Z40 1.0 B35 C35 D35 1.1 B35 P40 Z31 P40 C39 D58 1.2 B35 B35 Z39 B40 Z35 Z35 Z35 H50 A35 B40 B40 J40 J50 B58 1.3 Z35 Z35 Z35 Z35 C39 A35 N39 Z35 A35 J31 U50 D35 Z58 B58 A58 D58 1.4 Z58 A35 B40 H31 E31 E31 E31 C35 C35 S50 A58 Y50 C58 P39 P39 1.5 H31 H31 H31 E31 C31/ H31 E31 Z31 M58 E35 1.6 H31 H18 E31 E18 N31 P40 H18 E18 M35C35 1.7 Z18 N18 N31 U50 P39 H18 M35 U50 1.8 J31 H31 H31 1.9 J18 H18 Q50 7

250W MH, pulse start 250W MH, pulse start 250W MH, pulse start 15 18 15 9 9 TEST OF PE250PM00XP40 LAMP 250W Clear PMH 26300 WATTS 250 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =.6 3500 CD/DIV ANGLE CANDLE POWER 0 21521 5 18700 1785 10 17301 15 14661 4156 20 10205 25 7651 3542 30 5220 35 3607 2266 40 2647 45 2295 1777 50 2170 55 1670 1498 60 487 65 624 620 70 777 75 870 921 80 919 85 846 923 90 727 95 803 876 105 1056 1118 115 1485 1474 125 1807 1621 135 774 600 145 342 215 155 407 188 165 452 128 175 414 40 180 310 0-30 9483 36.1 30-60 5541 21.1 60-90 2464 9.4 0-90 17488 66.5 90-180 6260 23.8 0-180 23747 90.2 15 18 15 9 9 TEST OF PE250PM00XM35 LAMP 250W Clear PMH 26300 WATTS 250 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =1.2 1500 CD/DIV ANGLE CANDLE POWER 0 8990 5 8727 833 10 8667 15 9127 2587 20 8935 25 8778 4063 30 7886 35 6881 4323 40 4388 45 2297 1779 50 1514 55 1114 999 60 957 65 972 965 70 1014 75 996 1053 80 967 85 887 967 90 834 95 991 1081 105 1369 1448 115 1272 1263 125 580 521 135 378 293 145 480 302 155 473 219 165 273 77 175 155 15 180 108 0-30 7483 28.5 30-60 7101 27.0 60-90 2986 11.4 0-90 17570 66.8 90-180 5219 19.8 0-180 22789 86.6 15 18 15 9 9 TEST OF PE250PM00XS31 LAMP 250W Clear PMH 26300 WATTS 250 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =1.8 1000 CD/DIV ANGLE CANDLE POWER 0 3178 5 2992 286 10 2720 15 2762 783 20 2854 25 3292 1524 30 3785 35 4717 2963 40 5816 45 5501 4260 50 3811 55 2426 2176 60 1800 65 1638 1626 70 1626 75 1494 1580 80 1340 85 1191 1299 90 1088 95 1204 1314 105 1363 1442 115 1213 1204 125 1195 1072 135 1172 908 145 967 607 155 449 208 165 294 83 175 203 19 180 147 0-30 2593 9.9 30-60 9400 35.7 60-90 4506 17.1 0-90 16498 62.7 90-180 6858 26.1 0-180 23356 88.8 50682 50684 50685 0.94.94.94.76.76.76.65 1.83.80.78.68.66.65.55 2.75.70.67.62.59.57.49 3.68.63.58.57.53.51.44 4.62.56.52.52.49.46.40 5.57.51.47.49.45.42.37 6.53.47.43.45.41.38.34 7.49.43.39.43.39.36.32 8.46.40.36.40.36.33.30 9.43.37.34.38.34.31.28 10.40.35.31.36.32.29.26 0.93.93.93.77.77.77.67 1.82.79.76.68.66.64.56 2.73.68.64.61.58.55.49 3.65.60.55.55.52.49.43 4.59.53.49.50.46.43.38 5.54.48.43.46.42.39.34 6.49.43.39.43.38.35.31 7.45.39.35.39.35.32.28 8.42.36.32.37.32.29.26 9.39.33.29.34.30.27.24 10.36.30.26.32.27.24.22 0.94.94.94.75.75.75.63 1.80.76.72.63.61.59.49 2.69.63.58.55.51.48.40 3.60.53.48.48.43.39.33 4.53.45.40.42.37.33.27 5.47.39.34.37.32.28.23 6.41.34.29.33.28.24.20 7.37.30.25.30.25.21.17 8.34.26.22.27.22.18.15 9.30.24.19.25.20.16.13 10.28.21.17.23.18.14.11 400W MH 400W MH 400W MH 3500 CD/DIV 15 18 15 9 9 TEST OF PE400MH00XG40 LAMP 400W Clear MH 36000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =.8 ANGLE CANDLE POWER 0 20622 5 19182 1831 10 19785 15 19043 5398 20 14530 25 10662 4935 30 7215 35 4934 3100 40 3526 45 2950 2285 50 2754 55 2098 1882 60 708 65 887 880 70 1026 75 1172 1240 80 1268 85 1196 1305 90 1015 95 1011 1103 105 1309 1384 115 1900 1886 125 2585 2319 135 1746 1352 145 496 312 155 556 257 165 618 175 175 490 47 180 369 0-30 12164 33.8 30-60 7267 20.2 60-90 3425 9.5 0-90 22856 63.5 90-180 8836 24.5 0-180 31692 88.0 1800CD/DIV 15 18 15 9 9 TEST OF PE400MH00XE39 LAMP 400W Clear MH 36000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.1 ANGLE CANDLE POWER 0 10537 5 10954 1046 10 12113 15 13241 3753 20 12221 25 10170 4707 30 8113 35 6282 3947 40 4511 45 3482 2697 50 2126 55 1166 1046 60 1462 65 1561 1550 70 1665 75 1657 1753 80 1607 85 1497 1634 90 1411 95 1507 1645 105 1642 1737 115 1962 1948 125 2452 2200 135 1305 1011 145 533 335 155 591 274 165 520 147 175 366 35 180 289 0-30 9506 26.4 30-60 7689 21.4 60-90 4936 13.7 0-90 22131 61.5 90-180 9331 25.9 0-180 31462 87.4 1200CD/DIV 15 18 15 9 9 TEST OF PE400MH00XC31 LAMP 400W Clear MH 36000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.9 ANGLE CANDLE POWER 0 3849 5 3740 357 10 3489 15 3421 970 20 3573 25 3963 1834 30 4542 35 5703 3582 40 7192 45 7170 5553 50 5285 55 3542 3177 60 2533 65 2257 2240 70 2202 75 2067 2187 80 1855 85 1684 1838 90 1514 95 1599 1745 105 1888 1998 115 1778 1764 125 1756 1575 135 1634 1265 145 1480 930 155 705 326 165 388 110 175 264 25 180 191 0-30 3161 8.8 30-60 12313 34.2 60-90 6265 17.4 0-90 21738 60.4 90-180 9738 27.0 0-180 31476 87.4 50352 50349 50362 0.93.93.93.74.74.74.62 1.81.78.76.66.64.62.53 2.73.68.65.60.57.55.47 3.66.61.57.55.51.49.42 4.60.55.50.50.47.44.38 5.55.49.45.47.43.40.35 6.51.45.41.43.40.36.32 7.47.41.37.41.37.34.30 8.44.38.34.38.34.31.28 9.41.36.32.36.32.29.26 10.39.33.30.34.30.27.25 0.93.93.93.74.74.74.62 1.80.77.74.64.62.60.50 2.71.66.62.57.54.51.43 3.63.58.53.51.48.45.38 4.57.51.46.47.43.40.34 5.52.46.41.43.39.35.30 6.48.41.37.40.35.32.28 7.44.37.33.37.32.29.25 8.40.34.30.34.30.27.23 9.37.31.27.32.28.25.21 10.35.29.25.30.26.23.20 0.92.92.92.73.73.73.60 1.78.74.70.61.59.56.46 2.67.61.56.52.49.46.37 3.58.51.46.45.41.37.30 4.51.44.38.40.35.31.25 5.45.38.32.35.30.27.21 6.40.33.27.32.27.23.18 7.36.29.24.28.23.20.15 8.32.25.21.26.21.17.13 9.29.23.18.23.19.15.12 10.27.20.16.21.17.13.10 Photometric Data Metal Halide 8

Photometric Data Metal Halide 400W MH, pulse start 400W MH, pulse start 400W MH, pulse start 8000CD/DIV ANGLE CANDLE POWER 3000CD/DIV ANGLE CANDLE POWER 2000CD/DIV ANGLE CANDLE POWER 15 18 15 0 48915 5 34910 3332 10 29927 15 24274 6881 20 16317 25 11613 5375 30 7725 9 9 35 5224 3282 40 3813 45 3336 2584 50 3108 55 2146 1925 60 802 65 1017 1009 70 1234 75 1380 1460 80 1450 85 1321 1441 90 1172 95 1278 1395 105 1775 1877 115 2646 2627 125 3154 2830 135 1320 1022 145 597 375 155 729 337 165 779 221 TEST OF PE400PM00XE40 LAMP 400W Clear PMH 44000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =.6 175 683 65 180 509 0-30 15588 35.4 30-60 7790 17.7 60-90 3910 8.9 0-90 27288 62.0 90-180 10749 24.4 0-180 38037 86.4 15 18 15 9 9 TEST OF PE400PM00XE39 LAMP 400W Clear PMH 44000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.0 0 16323 5 15677 1496 10 16703 15 17432 4941 20 14758 25 12074 5589 30 9281 35 7078 4446 40 4940 45 3853 2984 50 2601 55 1335 1197 60 1680 65 1803 1790 70 1966 75 1971 2085 80 1949 85 1811 1976 90 1708 95 1844 2012 105 2004 2120 115 2540 2522 125 2958 2653 135 1267 981 145 666 418 155 751 347 165 646 183 175 452 43 180 354 0-30 12026 27.3 30-60 8627 19.6 60-90 5850 13.3 0-90 26504 60.2 90-180 11280 25.6 0-180 37784 85.9 15 18 15 9 9 TEST OF PE400PM00XA35 LAMP 400W Clear PMH 44000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.3 0 13235 5 11310 1080 10 10759 15 11543 3272 20 11786 25 12343 5713 30 12311 35 11352 7131 40 8562 45 4738 3669 50 2943 55 2019 1811 60 1626 65 1578 1566 70 1668 75 1692 1790 80 1723 85 1608 1755 90 1410 95 1458 1591 105 1956 2070 115 2453 2435 125 1753 1573 135 730 566 145 692 435 155 645 299 165 392 111 175 231 22 180 167 0-30 10065 22.9 30-60 12612 28.7 60-90 5111 11.6 0-90 27788 63.2 90-180 9101 20.7 0-180 36889 83.8 50673 50672 50679 0.91.91.91.72.72.72.61 1.80.77.75.65.63.61.52 2.72.68.64.59.56.54.46 3.65.60.56.54.51.48.42 4.60.55.50.50.47.44.39 5.55.50.46.47.43.40.36 6.51.46.42.44.40.37.33 7.48.42.38.41.37.35.31 8.45.39.35.39.35.32.29 9.42.37.33.37.33.30.27 10.39.34.31.35.31.28.26 0.91.91.91.72.72.72.60 1.78.75.72.62.61.59.49 2.70.65.61.56.53.50.42 3.62.57.52.51.47.44.37 4.56.50.46.46.42.39.34 5.51.45.41.43.38.35.30 6.47.41.36.39.35.32.28 7.43.37.33.36.32.29.25 8.40.34.30.34.30.27.23 9.37.31.28.32.28.25.22 10.35.29.25.30.26.23.20 0.91.91.91.74.74.74.63 1.79.76.73.65.63.61.52 2.70.65.61.58.55.52.45 3.62.57.52.52.48.45.39 4.56.50.45.47.43.40.35 5.51.45.40.43.39.35.31 6.46.40.35.39.35.32.28 7.42.36.32.36.32.28.25 8.39.33.29.33.29.26.23 9.36.30.26.31.27.23.21 10.33.27.23.29.24.21.19 400W MH, pulse start 400W MH, pulse start 1000W MH 1400CD/DIV ANGLE CANDLE POWER 2500CD/DIV ANGLE CANDLE POWER 5000CD/DIV ANGLE CANDLE POWER 15 18 15 9 9 TEST OF PE400PM00XC31 LAMP 400W Clear PMH 44000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.7 0 6161 5 5745 548 10 5112 15 4943 1401 20 4814 25 5145 2381 30 5638 35 6724 4224 40 8261 45 8515 6595 50 6158 55 4059 3642 60 2928 65 2641 2621 70 2627 75 2484 2628 80 2266 85 2051 2237 90 1841 95 1998 2180 105 2334 2469 115 2143 2127 125 2153 1931 135 2060 1596 145 1807 1135 155 793 367 165 485 137 175 329 31 180 236 0-30 4331 9.8 30-60 14460 32.9 60-90 7487 17.0 0-90 26278 59.7 90-180 11975 27.2 0-180 38252 86.9 15 18 15 9 9 TEST OF PE400PM00XB58 LAMP 400W Clear PMH 44000 BULB TYPE ED-37 TEST DISTANCE 25 ft S.C. =1.1 0 14506 5 14084 1344 10 13340 15 14126 4004 20 13713 25 12925 5982 30 10093 35 7698 4836 40 5541 45 3852 2983 50 2839 55 2258 2026 60 1995 65 1955 1941 70 1989 75 1914 2025 80 1840 85 1651 1801 90 1545 95 1714 1870 105 2394 2532 115 2268 2251 125 1210 1085 135 687 532 145 727 457 155 699 323 165 461 131 175 276 26 180 198 0-30 11331 25.8 30-60 9845 22.4 60-90 5767 13.1 0-90 26943 61.2 90-180 9208 20.9 0-180 36150 82.2 15 18 15 9 9 TEST OF EGPC10MH00XXY50 LAMP 1000W Clear SMH 125,000 WATTS 1000 BULB TYPE BT-56 TEST DISTANCE 25 ft S.C. =1.3 0 29588 5 28482 2719 10 26474 15 28327 8030 20 30698 25 34063 15766 30 37043 35 35731 22446 40 28327 45 15423 11945 50 6626 55 4340 3894 60 4365 65 4406 4374 70 4388 75 3975 4205 80 4045 85 4256 4644 90 4488 95 5020 5477 105 5569 5891 115 6867 6816 125 8954 8033 135 10337 8005 145 7194 4519 155 1886 873 165 1060 300 175 670 64 180 428 0-30 26515 21.2 30-60 38285 30.6 60-90 13222 10.6 0-90 78022 62.4 90-180 39979 32.0 0-180 118001 94.4 50668 50675 41906 0.91.91.91.72.72.72.59 1.77.73.70.60.58.56.46 2.66.61.56.52.48.45.37 3.58.51.46.45.41.37.30 4.51.44.38.40.35.31.25 5.45.38.32.35.30.27.21 6.40.33.28.32.27.23.18 7.36.29.24.29.24.20.16 8.32.26.21.26.21.17.14 9.29.23.18.24.19.15.12 10.27.21.16.22.17.14.11 0.88.88.88.71.71.71.61 1.76.73.70.62.60.58.50 2.67.62.58.55.52.50.43 3.60.54.50.50.46.43.37 4.54.48.44.45.41.38.33 5.49.43.39.41.37.34.30 6.45.39.34.38.34.31.27 7.41.35.31.35.31.28.24 8.38.32.28.33.28.25.22 9.35.29.26.30.26.23.21 10.33.27.24.28.24.21.19 0.98.98.98.77.77.77.62 1.86.82.79.67.65.63.52 2.76.71.67.60.57.54.45 3.68.62.57.54.50.47.39 4.61.54.49.49.45.41.35 5.55.48.43.44.40.37.31 6.50.43.38.41.36.33.28 7.45.39.34.37.33.29.25 8.42.35.30.34.30.26.22 9.38.32.27.32.27.24.20 10.35.29.25.29.25.22.18 9

400W HPS 400W HPS 400W HPS 6000CD/DIV ANGLE CANDLE POWER 1800CD/DIV ANGLE CANDLE POWER CORPORATION 1500CD/DIV ANGLE CANDLE POWER 15 18 15 9 9 TEST OF PE400HP00XM39 LAMP 400W Clear HPS 51000 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =.6 0 37136 5 28757 2745 10 23808 15 20426 5790 20 16593 25 13126 6076 30 10175 35 8060 5063 40 6230 45 4739 3670 50 2957 55 1920 1722 60 2047 65 2230 2214 70 2293 75 2188 2315 80 2127 85 2097 2288 90 2047 95 2258 2464 105 2685 2840 115 2542 2524 125 2182 1958 135 1328 1029 145 856 538 155 892 413 165 821 233 175 642 61 180 503 0-30 14611 28.6 30-60 10456 20.5 60-90 6817 13.4 0-90 31883 62.5 90-180 12058 23.6 0-180 43941 86.2 15 18 15 9 9 TEST OF PE400HP00XM35 LAMP 400W Clear HPS 51000 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =1.4 0 11689 5 9977 952 10 9664 15 10153 2878 20 10789 25 11237 5201 30 11669 35 12071 7583 40 10711 45 8205 6354 50 5865 55 4124 3700 60 2792 65 2162 2146 70 2092 75 2075 2195 80 2112 85 2100 2291 90 2045 95 2118 2311 105 2337 2472 115 2364 2346 125 2199 1972 135 1402 1086 145 805 506 155 653 302 165 419 119 175 265 25 180 196 0-30 9032 17.1 30-60 17637 34.6 60-90 6632 13.0 0-90 33300 65.3 90-180 11140 21.8 0-180 44441 87.1 15 18 15 9 9 TEST OF PE400HP00XH31 LAMP 400W Clear HPS 51000 BULB TYPE ED-28 TEST DISTANCE 25 ft S.C. =1.9 0 5673 5 5217 498 10 4905 15 5015 1421 20 5339 25 5926 2743 30 6811 35 8086 5079 40 9295 45 8991 6963 50 7432 55 5685 5101 60 4577 65 3675 3647 70 3179 75 2894 3061 80 2696 85 2552 2784 90 2384 95 2480 2706 105 2562 2710 115 2428 2411 125 2345 2104 135 2058 1594 145 1649 1036 155 977 452 165 581 165 175 392 37 180 284 0-30 4662 9.1 30-60 17143 33.6 60-90 9493 18.6 0-90 31299 61.4 90-180 13216 25.9 0-180 44514 87.3 50429 50427 50440 0.92.92.92.74.74.74.62 1.79.76.73.64.62.60.51 2.71.66.62.58.55.52.44 3.63.58.53.52.49.46.39 4.58.52.47.48.44.41.35 5.53.46.42.44.40.37.32 6.48.42.38.41.37.34.29 7.45.39.34.38.34.31.27 8.41.36.31.36.31.28.25 9.39.33.29.33.29.26.23 10.36.31.27.31.27.25.22 0.94.94.94.77.77.77.65 1.81.77.74.66.64.62.53 2.71.66.61.58.55.52.45 3.63.57.52.52.48.44.38 4.56.49.44.46.42.38.33 5.50.43.38.42.37.34.29 6.45.38.33.38.33.30.25 7.41.34.30.35.30.26.23 8.37.31.26.32.27.23.20 9.34.28.23.29.24.21.18 10.31.25.21.27.22.19.16 0.93.93.93.74.74.74.62 1.78.74.70.61.59.57.47 2.67.61.56.53.49.46.38 3.58.51.46.46.41.37.31 4.51.43.38.40.35.31.25 5.45.37.32.35.30.26.21 6.40.32.27.32.27.23.18 7.36.28.23.28.23.20.15 8.32.25.20.26.21.17.13 9.29.22.18.23.19.15.12 10.27.20.16.21.17.13.10 750W HPS 750W HPS 1000W HPS 5000CD/DIV ANGLE CANDLE POWER 4000CD/DIV ANGLE CANDLE POWER 3500CD/DIV ANGLE CANDLE POWER 15 18 15 0 33430 5 29556 2821 10 29103 15 29295 8304 20 28897 15 18 15 0 15859 5 15262 1457 10 16018 15 17956 5090 20 18655 15 18 15 0 16563 5 11794 1126 10 12144 15 14751 4181 20 16317 9 9 25 27603 12776 30 24738 35 21596 13567 40 17994 45 14656 11350 9 9 25 18584 8602 30 18360 35 17693 11115 40 17102 45 16138 12498 9 9 25 18883 8740 30 20622 35 21352 13413 40 21404 45 20868 16161 50 11494 55 9059 8127 60 6755 65 5080 5043 70 3889 50 14162 55 10921 9798 60 8059 65 5825 5782 70 4934 50 18516 55 16288 14613 60 13900 65 11340 11256 70 8889 75 3504 3706 80 4046 85 4269 4657 90 4215 95 4295 4687 75 5416 5729 80 6094 85 6473 7062 90 6412 95 6342 6920 75 7293 7716 80 7651 85 7780 8488 90 7736 95 8030 8762 TEST OF EP750HP00XXJ40 LAMP 750W Clear HPS 110,000 WATTS 750 BULB TYPE BT-37 TEST DISTANCE 25 ft S.C. =1.2 105 4529 6132 115 5177 5139 125 5231 4693 135 4134 3201 145 2306 1449 155 1439 666 165 1465 415 175 1438 137 180 1625 0-30 23902 21.7 30-60 33044 30.0 60-90 13407 12.2 0-90 70353 64.0 90-180 25178 22.9 0-180 95530 86.8 TEST OF EP750HP00XXH39 LAMP 750W Clear HPS 110,000 WATTS 750 BULB TYPE BT-37 TEST DISTANCE 25 ft S.C. =1.7 105 5796 6132 115 5405 5365 125 4615 4140 135 3101 2401 145 1539 967 155 1048 485 165 947 268 175 1065 102 180 1080 0-30 15149 13.8 30-60 33410 30.4 60-90 18573 16.9 0-90 67132 61.0 90-180 26781 24.3 0-180 93919 85.4 TEST OF EGPC10HP00XXQ50 LAMP 1000W Clear HPS 140,000 WATTS 1000 BULB TYPE E-25 TEST DISTANCE 25 ft S.C. =1.9 105 7633 8075 115 7774 7717 125 7779 6979 135 7291 5647 145 5475 3440 155 2645 1224 165 809 229 175 605 58 180 488 0-30 14048 10.0 30-60 44187 31.6 60-90 27460 19.6 0-90 85695 61.2 90-180 42130 30.1 0-180 127825 91.3 45884 44041 41920 0.93.93.93.75.75.75.64 1.80.77.74.65.63.61.52 2.71.66.62.58.55.52.45 3.63.57.52.52.48.45.39 4.56.50.45.47.43.39.34 5.51.44.39.42.38.34.30 6.46.40.35.39.34.31.27 7.42.36.31.36.31.27.24 8.38.32.28.33.28.25.22 9.35.29.25.30.26.23.20 10.33.27.23.28.24.21.18 0.91.91.91.73.73.73.61 1.76.73.69.61.58.56.47 2.66.61.56.53.49.46.38 3.58.51.46.46.42.39.32 4.51.44.39.41.37.33.27 5.46.39.33.37.32.28.23 6.41.34.29.33.28.25.20 7.37.30.25.30.25.22.18 8.34.27.22.28.23.19.16 9.31.24.20.25.21.17.14 10.28.22.18.23.19.15.13 0.95.95.95.75.75.75.61 1.80.76.72.62.59.57.46 2.68.62.57.53.49.46.37 3.59.52.47.46.41.38.30 4.52.44.39.40.35.31.25 5.46.38.33.36.30.26.21 6.41.33.28.32.27.23.18 7.37.29.24.29.23.20.15 8.33.26.21.26.21.17.13 9.30.23.18.24.19.15.12 10.27.21.16.22.17.13.10 Photometric Data High Pressure Sodium 10

Performance Specification Complete luminaire shall be Holophane catalog number. The luminaire shall consist of two sub-assemblies: ballast assembly containing the electrical components, mounting hardware and reflector attachment latches; and optical reflector. It shall have passed 0.5g accelerated fatigue vibration test, high ambient temperature test of and low ambient temperature test of -3C. The complete luminaire shall be listed by Underwriter Laboratories, Inc. as suitable for use in damp location ambients of up to 55 C as standard and be CUL listed. The die cast aluminum ballast housing shall be protected against corrosion by a seven stage pretreatment process followed by a sprayed on white polyester powder paint, cured and baked on at 218 C; which exceeds ASTM standards for hardness, humidity, impact and salt spray resistance to prevent cross hatch creep, fading, cracking, and other corrosion related deterioration. Mounting hooks and loops shall be self lubricating malleable cast iron and protected against corrosion with zinc plated chromate finish. All other hardware shall be zinc plated steel for corrosion protection. Optical Assembly Glass reflector shall be Endural prismatic borosilicate glass with a minimum wall thickness of 3 mm (.13 ) and be supported from a die cast socket housing with three 5 mm (.19 ) minimum diameter steel rods bolted to a bottom retaining ring made of 16 gauge zinc plated clear chromate steel. The tempered glass bottom closure shall hinge from this retaining frame. When bottom closure is latched at each support rod, it shall enclose the optical housing. Fixture to breathe through a nondeteriorating fiberglass gasket between the optical assembly and the ballast housing. When tested with a watt lamp, zonal outputs shall be not less than: Zonal % total degrees lamp lumens - - 9-9 9-18 Luminaire shall have a spacing criteria of. Optional Mounting Methods (Choose One) P Pendant The separable DN20NPT (.75 ) threaded conduit mounting plate with integral set screw shall provide quick install luminaire slide on attachment. Housing shall be balanced and suitable for support from hooks, loops or conduit. A wireway cover shall enclose the wiring chamber which is suitable for 9C supply wire. N Non-Disconnect Pendant and Thruway Wiring Box The die cast aluminum pendant and/or thru-way integral wiring box shall contain provisions for both DN20NPT (.75 ) conduit and direct ceiling mounting. It shall contain an integral hinge which connects with the die cast aluminum hinge pin on the housing to support the luminaire while electrical connections are made. It shall have the same corrosion resistant finish as the housing. It shall have two cast in side knockouts, four ceiling mount drill points, DN20NPT (.75 ) conduit threaded top opening, and be UL listed for up to five #10 AWG conductors for thru-way wiring. The fixture housing shall swing up and connect to the N box by latching the captive J bolt and wing nut without use of tools. Q - Quick-Disconnect Pendant and Thruway Wiring Box The die cast aluminum pendant and/or thru-way quick disconnect wiring box shall contain provisions for both DN20NPT (.75 ) conduit and direct ceiling mounting. It shall contain an integral hinge which connects with the die cast aluminum hinge pin on the housing to allow the luminaire to hang free with electrical disconnect. It shall have the same corrosion resistant finish as the housing. It shall have two cast in side knockouts, four ceiling mount drill points, DN20NPT (.75 ) conduit threaded top opening, and be capable of carrying up to five #10 AWG conductors for thru-way wiring. The fixture housing shall swing up and connect to the Q box by latching the captive J bolt and wing nut without use of tools. A dead front female receptacle shall be mounted inside the Q box which will make an electrical connection with the pre-wired male plug on the fixture housing. The receptacle shall be UL and CUL listed for connection to lighting branch circuits which can then be energized before the housing is attached. The grounding connection shall be the first to make contact and the last to disconnect. It shall be CUL Listed and listed per UL-1059 (Panel Board Accessory) and UL-98 (Enclosed and Dead Front Switches) permitting the fixture to be disconnected while under load to meet OSHA requirements for relamping. EGH (Remote Ballast) Optical specification shall be identical to that of the Prismalume Enclosed; however, it shall mount to a cast wiring box. This box shall permit circuit leads to be attached to socket leads while in a hinged position. Optical assembly then latches to the closed position. Wiring box may be pendant mount, suspended with loop, hook and cord, or ceiling mount with DN20NPT (.75 ) threaded side entry. To be used with Holophane Remote Ballasts. Prismalume Enclosed fixture is covered by the following patents: D332,503;D332,504; D333,011; 5,121,309. The physical properties of the Holophane Prismalume Enclosed Series luminaires represent typical average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Check with your local Holophane sales representative to assure current information 11

Application Photos 12

PE Ordering Data How to construct a catalog number for Prismalume Enclosed (PE) Fixture type EXAMPLE: PE 250MH 12 Q N H31 EM Fill in 1 2 3 4 5 6 7 cat. no.: 1 2 3 4 5 6 7 Catalog no. Description 1 Luminaire PE Prismalume Enclosed, (150W - 400W) integral ballast 2 Source and wattage 15AHP 150W/55V HPS Q, N 25LHP 250W HPS, energy saving ballast 250HP 250W HPS 40LHP 400W HPS, energy saving ballast 400HP 400W HPS 175MH 175W MH 250MH 250W MH and MV P 250PM 250W MH, pulse start 25LPM 250W MH, pulse start, energy saving ballast 25LMH 250W MH, energy saving ballast 320PM 320W MH, pulse start 35LPM 350W MH, pulse start, energy saving ballast Dia. 400MH 400W MH and MV 40LMH 400W MH, energy saving ballast Diameter Q, N P 400PM 400W MH, pulse start Optics mm (in.) mm (in.) mm (in.) 40LPM 400W MH, pulse start, energy saving ballast PE31 454 (17.875) 718 (28.250) 660 (26.000) 3 Voltage PE35 454 (17.875) 718 (28.250) 660 (26.000) PE39 530 (20.875) 706 (27.813) 649 (25.563) 12 120 volt PE40 603 (23.750) 702 (27.625) 645 (25.375) 20 208 volt PE50 711 (28.000) 854 (33.625) 797 (31.325) 24 240 volt PE18 454 (17.875) 768 (30.250) 711 (28.000) 27 277 volt PE58 454 (17.875) 768 (30.250) 711 (28.000) 34 347 volt 48 480 volt MT Multi-voltage (120 through 277V) VT 1 Vari-tap (120, 277, 347V) 4 Mounting/wiring Standard mountings P Pendant mount for conduit DN20NPT (.75 ) Q Quick disconnect power hanger for pendant and thru-way wiring N Non-disconnect power hanger for pendant and thru-way wiring Steel hook and Holoflex L or T Cord Drop mountings A 2 L cord drop wired phase to common. UL and dry location only. Available with 120, 208, 277 and 480V only. Not available with F2. C 2 Cord without plug. Not available with F2. E 2 T cord drop wired phase to common. Dry location only. Available through TSG only. Not available with F2. H 2 NEMA twistlock plug. Not available with F2. S 2 Holoflex II Selectable cord drop. UL/CUL and dry location only. Not available with 240V, MT, VT or F2. Cast hook and Holoflex L or T Cord Drop mountings B 2 L cord drop wired phase to common. UL and dry location only. Available with 120, 208, 277 and 480V only. F 2 T cord drop wired phase to common. Dry location only. Available through TSG only. T 2 Holoflex II Selectable cord drop. UL and dry location only. Available with 120, 208, 277, 347 and 480V only. 5 Fixture cord length N None. Must be used with P, Q, or N mountings only R 3 foot cord length. N/A with P, Q, or N mountings F 5 foot cord length. Available with S and T mounting only S 6 foot cord length. N/A with P, Q, or N mountings T 10 foot cord length. N/A with P, Q, or N mountings 6 Optics See catalog number from matrix on page 6 and 7 for desired spacing ratio and lamp. 7 Options and accessories See pages 15 and 16 for available options and accessories Note: 1 Available only with 250HP, 250MH, 320PM, 35LPM, 400HP and 400MH. 2 MT or VT available with cord, fusing and Holoflex through TSG. Customer specifies voltage for wiring. 13

How to construct a catalog number for Prismalume Enclosed (EGH/EP) Fixture type EXAMPLE: EGH 400HP 12 P S40 EM Fill in 1 2 3 4 5 6 cat. no.: 1 2 3 4 5 6 Catalog no. Description 1 Luminaire EP Prismalume Enclosed, integral ballast (400W mag reg, 750W, 1000W) EGH 1 Prismalume Enclosed, remote ballast 2 Source and Wattage EGH Q, N 250HP 250W HPS 25LHP 250W HPS, energy saving ballast 400HP 400W HPS 40LHP 400W HPS, energy saving ballast P 175MH 175W MH 250MH 250W MH and MV 25LMH 250W MH, energy saving ballast 400MH 400W MH and MV 40LMH 400W MH, energy saving ballast Dia. EP/EGH 750HP 750W HPS (N/A with MT or VT) EP C10HP 1000W HPS 750/1000W Diameter P Q, N 40RMH 400W MH, mag. reg. (N/A with MT, VT or EGH fixture) Optics mm (in.) mm (in.) mm (in.) 750PM 750W MH, pulse start EP31 472 (18.6) 734 (28.9) 795 (31.3) C10MH 1000W MH and MV EP40S* 544 (21.4) 766 (30.2) 827 (32.6) 3 Voltage EP50 659 (25.9) 886 (34.9) 947 (37.3) Weight: 25.42-31.75 kg / 34-70 lbs 12 120 volt 20 208 volt 24 240 volt 27 277 volt 34 347 volt (N/A with 750HP) 48 480 volt MT Multi-voltage (120 through 277V) H VT 2 Vari-tap (120, 277, 347V) 4 Mounting P Pendant mount for conduit DN20NPT (.75 ) Q Quick disconnect power hanger for pendant and thru-way wiring Dia. N No quick disconnect power hanger for pendant and thru-way wiring EGH (Remote Ballast Unit) 5 Optics Dia. H - height Optics mm (in) mm (in) Select catalog no. from matrix on page 7 for desired spacing ratio and lamp. EGH31 394 (15.5) 543 (21.4) EGH35 394 (15.5) 543 (21.4) 6 Options and accessories EGH39 472 (18.6) 533 (22) See pages 16 and 17 for available options and accessories EGH40 544 (21.4) 527 (20.8) EGH50 659 (25.9) 679 (26.8) Note: 1 Pulse start ballasts are not available for remote ballast fixture. EGH18 413 (16.2) 591 (28.8) EGH58 413 (16.2) 591 (28.8) 2 Available with 250HP, 400HP, 250MH and 400MH only. 1000W (EGH) EGH40S* 544 (21.4) 568 (22.4) EGH50 659 (25.9) 679 (26.8) Weight: 9.53-16.78 kg / 21-37 lbs * Dimensions include sag glass door EGH/EP Ordering Data 14

Options 110mm (4.5 ) 120mm (4.88 ) DN20NPT (.75 ) threaded entry 22mm (.88 ) UPH-36 130mm (4.94 ) 110mm (4.31 ) (2) wiring access covers PHCB Power-hook 30mm (1.06 ) 88mm (.31 ) x 10mm (.38 ) ceiling mounting (2) places Thru-way UPH-35 Mounting Detail UPH-35 Pendant UPH-36 (2) KO s for DN20 (.75 ) conduit Ballast housing Catalog number Description Options (factory installed) F1 Single fuse assembly for 120, 240, 277, 347V. F2 Double fuse assembly for 208, 240, 480V. (N/A with VT or steel hook mounting). PF-105 Loop, DN20NPT (.75 ) male; malleable iron; all fixtures except Q. PF-121 Safety hook, DN20NPT (.75 ) male; malleable iron; all fixtures except Q. PF-129 Anti-rotational hook, DN20NPT (.75 ) male; malleable iron; all fixtures except Q. PF-291 Gasketed hook, DN20NPT (.75 ) male; malleable iron; all fixtures except Q. 65 For use in 65 C ambients (available for C10HP, C10MH only). CDP-L5-15-3 (120V) 120V 914mm (3 ), three conductor cord and NEMA plug (order PF also) N/A with ER, MT, VT or Q. CDP-L6-15-3 (208/240V) 208/240V 914mm (3 ), three conductor cord and NEMA plug (order PF also) N/A with ER, MT or Q. CDP-L7-15-3 (277V) 277V 914mm (3 ), three conductor cord and NEMA plug (order PF also) N/A with ER, MT or Q. CDP-L24-20-3 (347V) 347V 914mm (3 ), three conductor cord and NEMA plug (order PF also) N/A with ER, MT or Q. CDP-L8-20-3 (480V) 480V 914mm (3 ), three conductor cord and NEMA plug (order PF also) N/A with ER, MT or Q. X For CDP option only. List length if other than 3. EM Standby lighting fixture uses a D.C. bayonet base, 250W (max.) tungsten halogen lamp (included) when temporary power failure extinguishes HID lamp. (Not available with C10MH, 750HP27 or 750HP48). ER Emergency lighting fixture less relay for use with a 120 volt external power source to operate a D.C. 250W (max.) bayonet base tungsten halogen lamp (included). (All fixtures except Q and EGH.) (Includes T condulet) Available with CDP, HFW, or PHCB through TSG. PS HPS protected starter (NA with 750HP ). PHCB (120, 208, 240, Power-hook cord, special configuration plug cap and PF-105 loop attached (use with UPH-35 or UPH-36 ); MT, VT available 277, 347V) though TSG. PHCB-L8-480 (480V) Power-hook cord, special configuration plug cap and PF-105 loop attached (use with UPH-35-L8-480 or UPH-36-L8-480 on 480 volt units only); all fixtures except ER, or Q. AERS AERS Automatic Energy Reduction System. Select DC low voltage or AC line voltage control system. Handled through TSG. Control Module and sensors must be specified through TSG. 4C rated. D35 35% low mode operation. (DC) N/A with 15AHP, MH or MP lamps, EM or EP luminaire. D50 50% low mode operation. (DC) N/A with 35LPM or EP luminaire. A35 35% low mode operation. (AC) N/A with 15AHP, MH or MP lamps, EM, CDP, PHCB, Q or EP luminaire. A50 50% low mode operation. (AC) N/A with MH or MP lamps, 35LPM, CDP, PHCB, Q or EP luminaire. HFW Holoflex flexible wiring system. EP luminaire only. Available through TSG. H HALT, Holophane automatic lamp time-out. Available for MH or PM lamps on EP fixture only. Available with MT or VT through TSG. Customer specifies voltage to be wired. 15

57mm (2.25 ) 73mm (2.88 ) 45mm (1.75 ) 92mm (3.62 ) 67mm (2.63 ) 71mm (2.78 ) PF-105-B Malleable iron Loop DN20NPT (.75 ) male PF-121-A Malleable iron Safety hook, DN20NPT (.75 ) male PF-129-A Malleable iron Anti-rotational hook DN20NPT (.75 ) male PF-116-A Malleable iron Loop DN20NPT (.75 ) female PF-122-A Malleable iron Safety hook, DN20NPT (.75 ) female PF-291 Malleable iron Safety hook, DN20NPT male Catalog number Description Accessories (shipped separately) LAMP Appropriate HID lamp supplied with fixtures PF-105-B Loop, DN20NPT (.75 ) male; malleable iron; not available with Q PF-116-A Loop, DN20NPT (.75 ) female; malleable iron; not available with Q PF-121-A Safety hook, DN20NPT (.75 ) male; malleable iron; not available with Q PF-122-A Safety hook, DN20NPT (.75 ) female; malleable iron; not available with Q PF-129-A Anti-rotational hook, DN20NPT (.75 ) male; malleable iron; not available with Q PF-291 Gasketed hook, DN20NPT (.75 ) male; malleable iron; not available with Q UPH-35-XXX-WH Thru-way power-hook (order PHCB with fixture); not available with MT, VT, ER, or Q. Insert voltage for XXX. (120, 208, 240, 277, 347V) UPH-35-L8-480-WH Thru-way power-hook (order PHCB-L8-480 with fixture); not available with ER, or Q UPH-36-XXX-WH Pendant power-hook (order PHCB with fixture); not available with MT, VT, ER, or Q. Insert voltage for XXX. (120, 208, 240, 277, 347V) UPH-36-L8-480-WH (480V) Pendant power-hook (order PHCB-L8-480 with fixture); not available with ER, or Q 09193 Wire guard for EP/EGH31 and EP/EGH35A optics. 09194 Wire guard for EP/EGH39 optics only. 09195 Wire guard for EP/EGH40 optics only. 09162-3 Chain, 914mm (3 ). 09216 Wire guard for EP40S optics. Chain Extra Chain - specify number of meters/feet. Ambient Temperature UL and CSA Listing Mounting Option N (Non-Disconnect) Q (Quick Disconnect) Lamp Wattage, Ballast Type P Through No Through Through No Through (Pendant) Wiring Wiring Wiring Wiring Metal Halide, 9C Building Wire 400W Peak Lead 55 C 55 C 55 C 55 C 55 C 400W EM, Peak Lead 55 C 55 C 55 C 55 C 55 C 400W Mag Reg 55 C 55 C 55 C 55 C 55 C 400W EM, Mag Reg 4C 4C 4C 4C 4C 1000W Peak Lead 55 C 55 C 55 C 55 C 55 C 1000W EM, Peak Lead 55 C 55 C 55 C 55 C 55 C Metal Halide, 105 C Building Wire 1000W 65 C Option, Peak Lead 65 C N/A 65 C N/A 65 C High Pressure Sodium, 9C Building Wire 400W Lead 55 C 55 C 55 C 55 C 55 C 400W EM, Lead 55 C 55 C 55 C 55 C 55 C 400W Mag Reg 55 C 55 C 55 C 55 C 55 C 400W EM, Mag Reg 4C 4C 4C 4C 4C 750W Lead 55 C 55 C 55 C 55 C 55 C 750W EM Lead (120, 208, 240 Only) 55 C 55 C 55 C 55 C 55 C 1000W Lead 55 C 55 C 55 C 55 C 55 C 1000W EM, Lead 55 C 55 C 55 C 55 C 55 C 1000W Compact Lamp, Lead N/A N/A N/A N/A 55 C 1000W EM, Compact Lamp Lead N/A N/A N/A N/A 55 C High Pressure Sodium, 105 C Building Wire 1000W 65 C Option, Lead 65 C N/A 65 C N/A 65 C 1000W Compact Lamp, Lead 55 C N/A 55 C N/A 65 C 16 Accessories

HALT Holophane Automatic Lamp Time-out (patent pending) H: Designed for metal halide fixtures operating 24 hours per day, 7 days per week, the HALT device will extinguish the individual luminaire s lamp for 15 minutes, once per week at random times, complying with lamp manufacturer s turn-off recommendations. HALT reduces the potential for non-passive end of life lamp failure while eliminating the inconvenience of switching on and off. For additional information see Holophane brochure HL-1926. Available with EP fixture. HALT HALT inside ballast housing UL 1572 listed standby light systems EM: When an HID lamp is extinguished due to a momentary power interruption, and power is immediately restored, an internal relay energizes a tungsten halogen lamp (QCL/DC) until the HID lamp restrikes, at which time the tungsten halogen lamp goes off. UL 924 listed emergency fixture ER: When an HID lamp is extinguished due to a power failure, 120V auxiliary power may be supplied directly to a tungsten halogen lamp Tee condulet included. Not CSA certified. EM, ER Standby, Emergency and HALT Options 17

N Mount fuse option: in line fuses are available for field installation N Mount fuse option P Mount fuse option: fuse holder attaches to splice box cover as shown. P Mount fuse option N/Q Fuse holder P Mount single fuse assembly Q Mount fuse option: fuse holder is standard. N/Q Fuse holder: is available as single fuse F1 for 120, 240, 277 and 347V; double fuse F2 available for 208, 240 and 480V. P Mount single fuse assembly F1 : available for 120, 240, 277 or 347V. P Mount double fuse assembly F2 : available for 208, 240 or 480V Q Mount fuse option P Mount double fuse assembly Fusing Holoflex wiring A modular single or three phase wiring system that provides flexibility in layout, quick installation and lower installed cost. Holoflex is available in a 4 and 5 wire circuit selector system. Holoflex II is available in a 3, 4, and 5 wire selectable cord drop. Holoflex system benefits Labor saving installation Flexibility; fixtures may be easily relocated without costly electrical system modifications Replaces power-hook and cord assemblies Ease of maintenance Possible tax advantages For additional information on Holoflex, see brochure HL-992. Holoflex HFW - Lighting T cord drop Three circuit power distribution Distribution Box Cable Home Run Cable Lighting Panel Distribution Box Cable Extender Cable Lighting Fixture Drop 18 Fusing and Holoflex Options

AERS Options AERS luminaire AERS Low voltage control wiring 12 Volt or 24 Volt Low Voltage DC Control Wiring (Class II) Control Module Line Voltage Feeds Sensor Locations The standard Holophane luminaire is designed with a modified ballast and relay. The modified ballast is designed to operate the lamp at two input wattages: HPS, normal input like a standard luminaire, and a reduced input, either 35% or 50% of full input; metal halide, normal input and a reduced input of 50%. The relay is wired to an occupancy sensor (or some type of contact closure) through a control module allowing the luminaire to switch between the two input wattages. The relay signals the ballast which input wattage to supply the lamp at any time. Low voltage control The AERS system can be installed separately from the main power distribution using low voltage DC control wiring. Each control module is designed to handle up to six zones. This system is ideal for adding to installations with existing power distribution. Line voltage control AERS is also available using line voltage control wiring. Line power and control wiring can run together through the same conduit. (Not available with Q, CDP or PHCB). AERS AC Power control wiring Holoflex Power Distribution with AERS Control Zone 3 AERS AC Holoflex Control Module Sensor Locations Zone 2 Conduit Zone 1 Distribution Panel For additional information see HL-1161 19

Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 / Holophane Canada, Inc. 9040 Leslie Street, Suite 208, Richmond Hill, ON L4B 3M4 / Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England / Holophane, S.A. de C.V., Apartado Postal No. 986, Naucalpan de Juarez, 53000 Edo. de Mexico Contact your local Holophane factory sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-707- 5830 or fax 905-707-5695. Limited Warranty and Limitation of Liability Refer to the Holophane limited material warranty and limitation of liability on this product, which are published in the Terms and Conditions section of the current product digest, and is available from our local Holophane sales representative. Visit our web site at www.holophane.com HL-1130 4/03 2003 Acuity Lighting Group, Inc Printed in USA