SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

Similar documents
SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

OPTIFLUX 6000 Technical Datasheet

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic Flowmeters. Product Overview.

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M

ISTEC MAGNETIC METERS

유량계전문제조업체. Electro Magnetic FLOWMETER

SITRANS F M. Flow sensor MAG 1100 F 3/59

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Flow Measurement SITRANS F M

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Magnetic-Inductive Flow Meter FMI

Electromagnetic Flow Meter Owner s Manual HARDWARE

Electromagnetic amplifier type ModMAG M10 for all detectors

OPTIMASS 3000 Technical Datasheet

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

OPTIMASS 2000 Technical Datasheet

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Electromagnetic amplifier Primo Advanced for all detectors

Magnetic-Inductive flow Meter fmi

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Magnetic Inductive Flowmeter EP / UMF2 (B)

Field IT Electro-Magnetic Flowmeters Sensors

Magnetic Inductive Flow

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

SITRANS F M flow sensors 711/A and 711/911E

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

Electromagnetic Flow Monitor magphant

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

Electro-Magnetic Flowmeters Sensors MagMaster MFE

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of

SITRANS P measuring instruments for pressure

Magnetic-inductive flow meter for hazardous areas

ProcessAutomatic EZ-Mag

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

WATERFLUX 3000 Technical Datasheet

Metal tube variable area flowmeter for gases, liquids and steam

OPTISWITCH 6500 C Technical Datasheet

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

OPTISWITCH 6500 C Technical Datasheet

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Process Industry. Diaphragm Seal Solutions

BATCHFLUX 5500 C Technical Datasheet

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Options guide. Electromagnetic flowmeters. M9xx

Pressure Transmitters for Sanitary Applications Model SA-11

WATERFLUX 3070 Technical Datasheet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

OPTIGAS 4010C Technical Datasheet

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

OPTIGAS 4010C Technical Datasheet

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Continuous level sensor NSK

LCMass Series Mass Flow Sensor

Magnetic-Inductive Flow Meter FMQ

Electromagnetic flowmeter EMKO E

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Hygienic Centrifugal pumps

Electromagnetic Flow Monitor magphant

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

WATERFLUX 3070 Technical Datasheet

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

FLUSH MOUNTED TC CONNECTION. Function: blind cap. Design: Requirement:

SANITARY SELF-PRIMING PUMPS CLOSED COUPLED WITH STANDARD MOTOR A - AS SERIES SELF-PRIMING PUMPS. Series A-AS

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Compact pressure switch Model PCS

Continuous Level Sensor NSL-F

PROCESSAUTOMATIC MAGNETIC FLOWMETER

Full Profile Insertion

SATRON VT Pressure Transmitter

QUALITY INDUSTRIAL FLOWMETERS

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Continuous level sensor NSL-F-00, -01, -02

OPTIFLUX Electromagnetic Flow Sensor

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

SANIBOXER - PRODUCTION PROGRAM INDUSTRIAL PUMPS SINCE 1982 FDA. Made in Italy. TÜV NORD Italia S.r.l. compliant

Continuous level sensor NSK

Transcription:

The electromagnetic designed for food industry DS200-1-ENG

The is specifically designed for use in the food processing industry. It is made of materials approved by international regulations, compatible with the temperature and products required for sanitary reasons, and equipped with the attachments used today in the foodstuffs industry. The sensors are manufactured with diameters from 25 to 100. The degree of protection is IP68 for a permanent submersion in water to a depth of 1.5 meters. The allows to measure very low flow rates precisely and repeatable, even in difficult applications or with solid parts contained in the fluid. This threaded sensor series bases its operation on the Faraday Principle, by which a conductor crossing a magnetic field generates a potential perpendicularly orientated to the same field. On top and on the lower part of the stainless steel AISI 304 flow tube, two coils are installed; the magnetic field generated by the electric current crossing the coils, induces in the electrodes a difference in the potential proportional to the flow rate. Connections and Internal lining: The sensors are manufactured completely in stainless steel AISI 304 with an internal liner of PTFE. The connections can be TRICLAMP, DIN11851 or SMS1146. The internal PTFE conform to the norms WRAS, FDA, DPR 777/82 e DM 21/09/773. Electrodes: The standard electrodes are in Hastelloy C and therefore this guarantees a wide compatibility with process fluids. If required, they may be supplied in Hastelloy B, Titanium, Tantalum. A partially empty tube detection is available and can be enabled or disabled through the software. 2 www.euromag.com DS200-1-ENG

Coupling and connection to the sensor: The sensors may be coupled to MC608A or MC608P converters. In the separate version the sensor is connected to the converter through a cable whose maximum length will not exceed 100. No pressure drop : The electro-magnetic s do not have any moving internal parts, thus they have a very low pressure drop. The s, does not have any restriction to the flow, allowing almost no pressure drop even when measuring viscous liquids or containing solid parts. Calibration and maximum error: The sensors belong to the reference Group B1 (ISO 11631). Each sensor is calibrated by an hydraulic bench equipped with a reference weighting system and ACCREDIA certified. The uncertainty of the calibration is equal to 0.2% +/- 2 mm/s. The repeatability is in the order of 0.1%. Bi-directional measure. Standards reference: The Euromag magnetic meters are marked CE and are manufactured according to the following standards: 2014/35/EU - EN 61010-1:2013 (LVD) 2014/30/EU - EN 61326-1:2013 (EMC) European directive 2014/32/EU (MID) (Pending) 2014/34/UE - IEC 60079-0, IEC 60079-18 (ATEX - IECEx) Separate version EHEDG (Pending) PTFE conform to the norms WRAS, FDA, DPR 777/82 e DM 21/09/773 Applications: Food & Beverage Chemicals Pharmaceutical Dosing applications Flowmeter 3

Advantages: No moving parts No parts inside of the No obstruction on the flow tube No pressure loss Long lasting stability and precision No filter needed, zero maintenance Resistance to periodic sanitary cleaning Extremely sturdy structure A dedicated Robot welds all the parts Internal parts protected by a bi-component resin in order to increase protection from external agents Bi-directional measure Technical features: Flow tube material AISI 304 AISI 316 (optional) Connections material AISI304 AISI 316 (optional) Available electrodes Hastelloy C (standard) Hastelloy B Titanium Tantalum Internal lining PTFE for food Liquid temperature Separate -40 C / + 130 C (180 C optional) / Compact -25C / + 80C Available diameters mm 25 32 40 50 65 80 100 inches 1 1 ¼ 1 ½ 2 2 1/2 3 4 Standard connections Triclamp Other connections available DIN 11851 Female SMS 1146 Female Standard operation pressure Number of electrodes Installation requirements/conditions 16 bar with Triclamp / 25 Bar with DIN or SMS 2 Standards 3rd electrode for empty pipe alarm as option U5 D3 Protection Degree IP68 permanent submersion at 1,5 m (EN 60529) Convertes compatibility Electrical connections Hygienic MC608A/P Cableglands M20 x 1.5 + terminal box (aluminum std, polycarbonate optional) + sealing resin FDA approved materials EHEDG Pending 4 www.euromag.com DS200-1-ENG

Characteristics and process connections: DIN 11851 SMS 1146 TriClamp DIN11851 SMS1146 25 1 50,4 Rd 52 x 1/6 Rd 40 x 1/6 32 - - Rd 58 x 1/6" - 40 1 1/2 64 Rd 65 x 1/6 Rd 60 x 1/6 50 2 64 Rd 78 x 1/6 Rd 70 x 1/6 65 2 1/2 77,5 Rd 95 x 1/6 Rd 85 x 1/6 80 3 91 Rd 110 x 1/4 Rd 98 x 1/6 100 4 119 Rd 130 x 1/4 Rd 132 x 1/6 TriClamp Process connection: D6 Di D5 L4 (mm) L2 (mm) Lr (mm) D5 (mm) Di (mm) D6 (mm) 25 1 150 (+1/-3) 76 37,5 75 22,6 50,4 40 1 1/2 157 (+1/-3) 86 36 75 37,6 64 / 50.4 50 2 174 (+1/-3) 94 40 92 48,6 64 65 2 1/2 194 (+1/-3) 100 47 107 60,3 77,5 80 3 200 (+1/-3) 107 47 130 73 91 100 4 216 (+1/-3) 120 48 150 97,6 119 Flowmeter 5

DIN 11851 Process connection: L4 (mm) L2 (mm) Lr (mm) D5 (mm) Di (mm) D6 (mm) 25 1 150 (+1/-3) 76 37 75 22,6 Rd 52 x 1/6 32-236 (+1/-3) 76 80 75 22,6 Rd 58 x 1/6" 40 1 1/2 157 (+1/-3) 86 41 75 37,6 Rd 65 x 1/6 50 2 180 (+1/-3) 94 43 92 48,6 Rd 78 x 1/6 65 2 1/2 196 (+1/-3) 100 48 107 60,3 Rd 95 x 1/6 80 3 213 (+1/-3) 107 53 130 73 Rd 110 x 1/4 100 4 244 (+1/-3) 120 62 150 97,6 Rd 130 x 1/4 SMS 1146 Process connection: D6 Di D6 Di D5 D5 L4 (mm) L2 (mm) Lr (mm) D5 (mm) Di (mm) D6 (mm) 25 1 132 (+1/-3) 76 28 75 22,6 Rd 40 x 1/6 38 1 1/2 152 (+1/-3) 86 33 75 37,6 Rd 60 x 1/6 51 2 160 (+1/-3) 94 33 92 48,6 Rd 70 x 1/6 63 2 1/2 174 (+1/-3) 100 37 107 60,3 Rd 85 x 1/6 76 3 181 (+1/-3) 107 37 130 73 Rd 98 x 1/6 101 4 200 (+1/-3) 120 40 150 97,6 Rd 132 x 1/6 6 www.euromag.com DS200-1-ENG

Aluminium separation box 145 171 125 2 x M20 68 173 106 104 2 x M20 74 Policarbonate separation box 123 86 2 x M20 52 131 180 112 68 126 H1 (mm) H2 (mm) H3 (mm) H4 (mm) 25 1 163,5 220,5 108,2 182,2 32-163,5 220,5 108,2 182,2 40 1 1/2 163,5 220,5 108,2 182,2 50 2 172 229 116,7 190,7 65 2 1/2 179,5 236,5 124,2 198,2 80 3 191 248 135,7 209,7 100 4 201 258 145,7 219,7 Flowmeter 7

gasweb.it DS200-1-ENG EUROMAG INTERNATIONAL Srl Via della Tecnica, 20-35035 Mestrino (Padova) Italia Tel. +39 049.9005064 - Fax +39 049.9007764 www.euromag.com - www.euromagdata.com euromag@euromag.com All rights reserved. No part of this catalogue may be reproduced, stored in a database or otherwise used without the authorisation of Euromag. The policy of Euromag is dictated by the continuing technological and project innovation. Therefore, the Company reserves the right to amend the data contained herein without notice.