INSTRUCTIONS CERAMIC METAL HALIDE REFLECTOR PHR3150

Similar documents
INSTRUCTIONS 315W CERAMIC METAL HALIDE E-BALLAST PHBC3150

USER MANUAL DOUBLE ENDED LIGHTING SYSTEMS (ALL MODELS) OPEN, ENCLOSED AND SUPER DEEP SYSTEMS

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

GC SERIES HORTICULTURAL LIGHTING SYSTEM

1000 DE BOSS. Installation & Operating Instructions COMMERCIAL FIXTURE READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST

Installation/Operating Instructions

GC SERIES HORTICULTURAL LIGHTING SYSTEM

Installation/Operating Instructions

Gavita TripleStar 600 EU

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

MAINTENANCE SPECIFICATIONS LEGISLATION WARRANTY

Gavita HortiStar 600 SE EU

Technical Information Guide

Lamps CERAMIC METAL HALIDE

Maximum Weight Capacity: Top Glass Shelf: 110 lbs. MODEL E113E ASSEMBLY INSTRUCTIONS. Important! Read all warnings before starting assembly.

UNPACKING THE UNIT. Alcohol cleaning pad

Installation/Operating Instructions

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

IMPORTANT: SAFETY INSTRUCTIONS

Assembly & Exercise Guide. Carefully reading and keeping the operating Instructions before use.

INSTALLATION INSTRUCTION Magnetic Transformer

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

MODEL VW2960C ASSEMBLY INSTRUCTIONS

ITEM # V LITHIUM-ION CHARGER MODEL #KRC Español p. 6. ATTACH YOUR RECEIPT HERE Serial Number. Purchase Date

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

Installation Instructions CRAFT M/L

Owner s Manual Dual Flat Screen Desktop Mount

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

shadow focus floodlight SFS-300 INSTRUCTIONS

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

LyteLaunch Dry - Wet and DMX Models. Operation Manual

NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

INSTRUCTION BOOK FOR. Dual Masking Electrol

INSTALLATION TEMPLATE

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

ASSEMBLY AND INSTALLATION INSTRUCTIONS

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Assembly Instructions Instrucciones para ensamblar Instructions de montage. Montageanleitungen Montage-instructies

80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe

ALU-29CF Portable Light NSN:

Installation and Maintenance Instructions

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

Pure Sine Wave Inverter USER MANUAL

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures.

Owner s Manual Full-Motion Ceiling Mount

Have a Bright Day! Nicholas Harmon President and CEO

StreetSense LED Street Light - UL for Roadway and Area Illumination

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Captivate Illuminated Mirror Light

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

MOONRING 1.5 MOONRING 3

OCTA FLUORESCENT 7 SOCKET FIXTURE

Image Pro. Create eye-catching holiday displays or project personalized images. Image projection system

LAL SERIES LED LUMINAIRE

Operating Manual. Follow all safety precautions!

Specification Grade Contemporary Wall Mount/Technical Installation Data

SV38-250w. SV38 technical specifications

MAXLITE RKT LED Retrofit Kit

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

MODELS SafeSite LED Linear, Class I Div V, 2 & 4 Versions

Installation Instructions Hardtop Hoist Part#

SPECIALTY TOP CO. STC. INSTALLATION INSTRUCTIONS TOYOTA FAST TRAC Z TOP Toyota FJ PART #222-31X 82 1/8" 82 1/8"

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

DC TO AC POWER INVERTER 150W DC/AC VERMOGENSINVERTER 150W INVERSEUR CC/CA 150W CONVERTIDOR CC/CA 150W WECHSELRICHTER DC/AC 150W

HARDWARE KIT INSTALLATION GLOVES

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

READY FOR CHECK-IN? RECEPTION ROOMOR COLLECTION

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

25W Explosion Proof LED Light VAC or 11-25V AC/DC - Pedestal Mount - 100' Cord w/ EPP Cap

WF-400S/FF Kit WF-400S/FG Kit WF-400S/FH Kit WF-400S/FI Kit WF-400S/F2 Kit

FOODSAFE IL INSTALLATION MANUAL

MOTION-ACTIVATED WALL LANTERN

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

LED Trouble Light / Hand Lamp / Drop Light -10 Watt LED Bulb - 12 Foot SJOW Cord

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

SV14 technical specifications

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

EA5506. Electrically Actuated Carbon Steel PN16 Ball Valve. Description

CORDED CORDLESS RECHARGEABLE

60 Watt Industrial LED Low Bay Light

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

LHS-001 QUICKSTART GUIDE. 650 Watt Tungsten Open Face Light (Lightstar)

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

KINESIS K3 ONE (1) YEAR LIMITED WARRANTY AND RETURN POLICY

Transcription:

INSTRUCTIONS CERAMIC METAL HALIDE REFLECTOR PHR3150

DESCRIPTION INSTRUCTIONS Thank you for purchasing Hydrofarm s Phantom CMh 315 (PHR3150) ceramic metal halide re ector. When used with our matched Phantom CMh ballast and 315-watt ceramic metal halide lamp, this re ector is designed to provide superior PAR light delivery with a very uniform light spread. WARNING: FAILURE TO FOLLOW OUR GUIDELINES COULD RESULT IN ELECTRICAL SHOCK. Do not touc ove s r or c e n our t ture en t s u e n. o t to coo o n e ore n n. eco en e ountin c e r nce or our ture s 12 on s es. o not ount rect to n sur ce. HANGING THE PHR3150 REFLECTOR 1. Upon opening the box, note any dented, deformed, or damaged parts. If any part of your unit is broken or damaged, immediately notify your retailer. 2. Remove plastic bag from re ector and inspect the re ector for any damage. 3. Locate the ceiling joist with a stud finder. If you cannot locate the joist, insert expansion anchors into the ceiling. The anchors (and the hooks used with them) should be rated to hold at least 50 lbs each. 4. Screw an eyebolt, J-hook, or some other means of hanging the re ector securely from the ceiling into the joist or anchor. Screw a second eyehook further down the joist or in an anchor to balance hanging the re ector. 5. Attach a chain, rope, or other sturdy material to the eyehooks (we recommend Hydrofarm s Light Riser, item code LULIFT). 6. Secure the chain, rope, carabiner clips, etc. to the CMh 315 s integrated hangers.. Use the cable tie provided to secure the electrical cord to the hanging cord/chain so that the cord s weight doesn t tilt the fixture. 8. Adjust the re ector s height to the desired distance above the plant canopy. LAMP INSTALLATION Wearing gloves if possible, remove your lamp from its packaging (lamp must be Philips 315W 38 mm T12 ceramic metal halide for PG 18 socket). Install the lamp into the socket by inserting the pins on the lamp base into the matching shaped holes in the socket and turning the lamp a quarter turn to the right (clockwise)(see photo below). When the lamp is properly installed, the base will stop turning and the lamp will feel firmly seated. The lamp is operated in vertical position in this re ector. NOTE: I r coo n o t s re ector s es re or er t e o tion r Coo n t PH 3150C c rov es t o n es n se n ens s ste.

CLEANING THE REFLECTOR AND LAMP Unplug the reflector and allow it to cool. INSTRUCTIONS Wearing gloves, carefully remove the lamp and set it aside. Mix warm, mild soap and water and apply sparingly to the reflector s aluminum interior with a clean washcloth. Dry with a second washcloth. Flip reflector over to cleanse both sides. Run a dry, soft washcloth over the lamp to remove dust particles, taking care not to leave any skin oils/fingerprints on it (try to wear gloves whenever handling the lamp). Install the lamp back into the socket in the reflector. TIPS The lamp may require 10 30 minutes cooling time before restarting. After you plug in and power on the ballast, the lamp may require several minutes to reach its full brightness. Be aware that in the event of a momentary power interruption, the lamp will not restart immediately. Some variation in the color of light emitted by the lamp is not unusual, especially in the first 100 hours of operation. Never pull the cord to unplug the reflector; pull the plug only. Avoid scratching the lamp, subjecting it to undue pressure, or getting it wet when it is hot these actions may cause the lamp to break. In the event of lamp breakage, immediately unplug the reflector to prevent exposure to ultraviolet energy, which may be harmful to eyes and skin. Keep room temperature below 95 F, with adequate air circulation provided by oscillation fans in the growing area. Please take care to consider proximity to plants when installing your fixture. Closer proximities will give greater intensity, but they will also reduce the effective coverage footprint. Always use a heavy-duty three-pronged grounded timer, rated for at least 15 amps.

SPECIFICATIONS SPECIFICATIONS DIMENSIONS 18"L x 18"W x 11"H WEIGHT 8 lbs INTERIOR 95% re ectivity hammertone aluminum SOCKET PGZX18 (built-in) LAMP COMPATIBILITY 315W ceramic metal halide T12 (38 mm) PGZX18 base only LENS Available with optional cooling kit (item code PHR3150CKT) FLANGES Available with optional cooling kit (item code PHR3150CKT) DIMENSIONES PESO SPECIFICATIONS 45 cm (L) x 45 cm (An) x 28 cm (Al) 3,6 kg INTERIOR Aluminio de efecto martelé con reflectividad del 95% PORTALÁMPARAS LÁMPARAS COMPATIBLES LENTE BRIDAS PGZX18 (incorporado) Halogenuro metálico y tecnolog a cerámica de 315W T12 (38 mm) únicamente para portalámparas PG 18 Disponibles con el kit de aire condicionado opcional (código del producto PHR315CKT) Disponibles con el kit de aire condicionado opcional (código del producto PHR315CKT)

WARRANTY LIMITED WARRANTY Hydrofarm warrants the PHR3150 re ector to be free from defects in materials and workmanship. The warranty term is 5 years beginning on the date of purchase. Misuse, abuse, or failure to follow instructions is not covered under this warranty. Hydrofarm will, at our discretion, repair or replace the re ector covered under this warranty if it is returned to the original place of purchase. Call your place of purchase to receive a return authorization form for a faulty part. Unauthorized returns will not be accepted. To request warranty service, please return the re ector, with original sales receipt and packaging, to your place of purchase. The purchase date is based on your original sales receipt. GARANTÍA LIMITADA Hydrofarm garantiza que el PHR3150 no presenta defectos en los materiales ni la fabricación. La vigencia de la garantía es cinco años que comienza en la fecha de compra. Esta garantía no cubre el uso erróneo, el abuso o el incumplimiento de las instrucciones. Hydrofarm, según si criterio, reparará o sustituirá el PHR3150 incluido en esta garantía si se devuelve al centro original de compra. Para solicitar el servicio de garantía, devuelva el PHR3150, con el tique de compra y el embalaje originales, a su centro de compra. La fecha de compra se basa en su tique de compra original. GARANTIE LIMITÉE Hydrofarm garantit que le PHR3150 ne présente pas de défauts de matériel ni de fabrication. La garantie est en vigueur pendant cinq ans à compter de la date d achat. Cette garantie ne couvre pas l utilisation incorrecte, l abus ou le non respect de la notice. Hydrofarm, selon ses critères, réparera ou remplacera le PHR3150 couvert par cette garantie s il est renvoyé au centre original d achat. Pour demander le service de garantie, renvoyer le PHR3150, avec le ticket d achat et l emballage originaux, au centre d achat. La date d achat est indiquée sur le ticket d achat original. BEGRENZTE GARANTIE Hydrofarm gewährleistet, dass der PHR3150 ohne Material- und Herstellungsmängel geliefert wird. Die Garantiedauer beträgt fünf Jahre und beginnt zum Kaufdatum zu laufen. Schäden, die aufgrund eines unsachgemäßen Gebrauchs oder der Nichteinhaltung der Anleitungen entstehen, sind von der Garantie nicht gedeckt. Hydrofarm wird den unter Garantie stehenden PHR3150 nach eigenem Ermessen entweder reparieren oder ersetzen, sofern die Rückgabe an der Verkaufsstelle, an der er erworben wurde, erfolgt. Um Garantieleistungen zu beantragen, senden Sie den PHR3150, mit Original-Kau eleg und Verpackung, um Ihre Verkaufsstelle. Das Kaufdatum ist auf dem Original- Kau eleg basiert. PH 3150 Instructions - rev..02.2015

INSTRUCTIONS 315W CERAMIC METAL HALIDE E-BALLAST PHBC3150

INSTRUCTIONS Thank you for your purchase of the Phantom CMh ballast (PHBC3150). Supply power for the ballast is based on typical commercial or residential input. This ballast should be used only with the matching 315W ceramic metal halide lamp to achieve the highest efficiency, safety, luminosity, and proper operation. ALWAYS DISCONNECT THE BALLAST S POWER CORD BEFORE MOVING UNIT OR CHANGING LAMPS WARNINGS Use this Phantom CMh ballast indoors only. Position it in an area away from excessive heat or contact with liquids. This ballast does not rely on the luminance enclosure for protection against accidental contact with live parts. Use the Phantom CMh ballast with a maximum lamp cord length of 50 feet. Disconnect the ballast from the power supply before performing any maintenance, lamp changes, or other modifications. Opening the ballast will void the warranty. Do not use lamps of any type other than the 315W (T12 38 mm PGZX18 base) with this ballast. Not for use with external ignitors. Do not use the Phantom CMh ballast with Hydrofarm s TM01240 240V timer. The TM01240 timer is not designed for use with electronic ballasts and using it may cause the ballast to fail. The Phantom CMh ballast is designed to be used with Hydrofarm power cords ONLY. Using it with other power cords, or modifying the power or lamp cords, will void the warranty. DEFINITION OF TERMS Main Voltage Rated input voltage for the ballast Watts Input power Amps Input current or draw Power Factor A measurement of how effectively the ballast converts electrical current to useful power output, in this case, output to the lamp. Power factor is measured between 0-1; the closer you get to 1, the more effective the circuit is said to be. The Phantom s power factor is greater than.98. Working Voltage The acceptable operating range for input voltage to the ballast. Deviations from the rated numbers may result in decreased ballast performance and additional case generated heat. Ignitor Voltage Ballast output during ignition sequence THD (Total Harmonic Distortion) A measurement of all harmonics present in a circuit. The higher the number, the more stress is applied to internal parts, the lamp, and the power grid. Generally, a number below 10% is considered desirable in an electronic ballast application. 2

INSTRUCTIONS CF (Crest Factor) A measurement of how clean the ballast power output wave is. A perfectly clean output sine wave would have a CF of 1.414. Given that some harmonics must exist in an electrical system, the crest factor must always be higher than 1.414. Therefore, the closer the ballast is to a CF of 1.414, the easier it is on the lamp. ta (Ambient Temperature) Maximum rated ambient temperature for the ballast area. Excessive ambient temperature can result in ballast failure, safety shutdown, or lamp failure. tc (Case Temperature) Maximum temperature that the case of the ballast should reach. If the case temperature exceeds this number, the ballast may be malfunctioning or the ambient temperature may exceed the rating. INSTALLING AND CONNECTING THE BALLAST 1. Find a suitable location for the ballast with sufficient cooling and away from any heat source. 2. Install the lamp firmly into the lamp socket and connect the lamp cord to the ballast. 3. Plug the power cord into the power input panel on the side of the ballast. 4. Plug the power cord into the power source (electrical outlet - 120/240V only). NOTE: For proper break-in on new lamps, we recommend that you run the ballast and lamp for at least 12 straight hours after initial startup. This will improve lamp life and performance. MOUNTING THE BALLAST ON THE WALL 1. Find a suitable location for the ballast. You will need a space at least 9½ wide. You will need to install two wall screws approximately 9 apart. If studs or another wooden mounting surface are not available, use drywall anchors sufficient to hold 15 lbs. Ensure that the screw heads are large enough not to slip out of the screw slots in the ballast frame. 2. Hold the ballast up to the spot where you want to wall-mount it, and make sure it is level. With a pen or pencil, make dot marks on the wall where you will be putting the screws. (We recommend drilling pilot holes if your mounting surface is hard wood, like a stud.) 3. After preparing your holes, hold the ballast in place and install the two screws. Carefully tighten the screws until the ballast is secure. Do not overtighten. SPECIFICATIONS Input power 340W Output power (Max) 315W Output voltage 120V/208V/240V Safe voltage 90V~260V Amps 2.3A/120V, 1.63A/208V, 1.41A/240V Input frequency 50/60Hz Power Factor >0.99 3

WARRANTY LIMITED WARRANTY Hydrofarm warrants the PHBC3150 to be free from defects in materials and workmanship. The warranty term is for 3 years beginning on the date of purchase. Misuse, abuse, or failure to follow instructions is not covered under this warranty. Hydrofarm will, at our discretion, repair or replace the PHBC3150 covered under this warranty if it is returned to the original place of purchase. To request warranty service, please return the PHBC3150, with original sales receipt and original packaging, to your place of purchase. The purchase date is based on your original sales receipt. GARANTÍA LIMITADA Hydrofarm garantiza que PHBC3150 no presenta defectos en los materiales ni la fabricación. La vigencia de la garantía es 3 años comienza en la fecha de compra. Esta garantía no cubre el uso erróneo, el abuso o el incumplimiento de las instrucciones. Hydrofarm, según si criterio, reparará o sustituirá PHBC3150 incluido en esta garantía si se devuelve al centro original de compra. Para solicitar el servicio de garantía, devuelva PHBC3150, con el tique de compra y el embalaje originales, a su centro de compra. La fecha de compra se basa en su tique de compra original. GARANTIE LIMITÉE Hydrofarm garantit que PHBC3150 ne présente pas de défauts de matériel ni de fabrication. La garantie est en vigueur 3 ans à partir de la date d achat. Cette garantie ne couvre pas l utilisation incorrecte, l abus ou le non respect de la notice. Hydrofarm, selon ses critères, réparera ou remplacera PHBC3150 couvert par cette garantie s il est renvoyé au centre original d achat. Pour demander le service de garantie, renvoyer PHBC3150, avec le ticket d achat et l emballage originaux, au centre d achat. La date d achat est indiquée sur le ticket d achat original. BEGRENZTE GARANTIE Hydrofarm gewährleistet, dass der PHBC3150 ohne Material- und Herstellungsmängel geliefert wird. Die Garantiedauer beträgt 3 Jahre und beginnt zum Kaufdatum zu laufen. Schäden, die aufgrund eines unsachgemäßen Gebrauchs oder der Nichteinhaltung der Anleitungen entstehen, sind von der Garantie nicht gedeckt. Hydrofarm wird den unter Garantie stehenden PHBC3150 nach eigenem Ermessen entweder reparieren oder ersetzen, sofern die Rückgabe an der Verkaufsstelle, an der er erworben wurde, erfolgt. Für die Beantragung der Garantieleistungen ist der PHBC3150 mit der Quittung und in der Originalverpackung an der Verkaufsstelle zurückzugeben. Als Kaufdatum gilt jenes Datum, das dem Kaufticket im Original zu entnehmen ist. PHBC3150 Instructions - rev.7.14.2015