VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Similar documents
Molded Case Circuit Breakers Reference Guide

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Critical Power Switchboards. Selection and Application Guide

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Power Break II Switchboard

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

VL Circuit Breaker DG 150A frame

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Engine Generator Circuit Breakers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Product Line Overview. The Most Logically Designed Contact Assembly

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

OTEC Transfer switch open transition

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers

Selection Guide Motor Control Device Solutions

Tmax Molded Case Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers

A. Submit manufacturer's literature and technical data before starting work.

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Product Specification Sheet #3LD2.1

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Moulded case circuit breakers

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Power System Solutions (PSS)

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Air Circuit Breakers

Transfer switch OTEC open or delayed transition

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

ACW Molded-Case Circuit Breaker UL 489 Listed

Air Circuit Breakers

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

BAC Custom Engineered Controls

Molded Case Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SENTRON VL Series Product Specifications

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

Transfer switch OTEC and OTECSE open transition

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Cutler-Hammer. January 2001

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Control Circuit Protection

UMBW-UL489 and UL1077 Listed

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Product Guide. enclosed NEMA STARTERS

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

LOW VOLTAGE SWITCHGEAR

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

DPX moulded case circuit breakers

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Application guide. Tmax Link OEM UL 891 Switchboard Program

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Transfer switch OHPC open or delayed transition

Molded Case Circuit Breakers

ATevo SERIES BATTERY CHARGER

Molded Case Circuit Breakers

Horizontal Circuit Switchers

PowerPact B. Molded case circuit breakers and switches from A

ACS motor protection circuit breakers KT 7 Introduction

Molded Case Circuit Breakers

Medium Voltage Metal-Enclosed Switches

F-Series. Circuit Breaker

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Bussmann series Quik-Spec Power Module Switch elevator disconnect

F-Series. Circuit Breaker

30 ma Ground Fault (Earth Leakage) Modules. Product Description

Cutler-Hammer. January 2001

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Moulded Case Circuit Breakers

OTPC-SE Service entrance transfer switch open transition

Switchboards Instant Service

Industry Automation Control Components

209 Series. Magnetic Circuit Protectors

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Molded Case Circuit Breakers

CTi Automation - Phone: Fax: Web:

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Horizontal Circuit Switchers

AT EVO SERIES BATTERY CHARGER

Transcription:

VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS

A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless possibilities. You take this concept of Tangram-like modularity and apply it to a new breed of breakers. Suddenly you have countless possibilities with steadfast reliability. Cost-Saving Module by module, VL circuit breakers address the critical issue: Your costs for operational processes, space and energy. The advantages range from simple retrofitting right up to compact construction, benefiting all those who work with VL circuit breakers; whether planner, wholesaler, switchboard manufacturer or plant operator. Easy Planning A few modular components open up the possibility of thousands of different combinations for all energy distribution applications. Saving costs, contributing to flexible planning and offering simple integration within overlapping system solutions by communication. Never before have circuit breakers been so versatile and so simple. Global No matter what the electrical standard, no matter where on earth, VL circuit breakers are optimally designed for most applications. The uniform design for global applications provides a standard solution a solution you can trust anywhere. System Solutions Siemens, a name that stands for innovation, now brings a new set of advancements to circuit protection. With the ability to communicate over common protocols, the VL integrates with the broader system giving you the advantage of system monitoring capabilities along with cost effective installations. Build to today s needs, and as your plant capacity or markets expand, VL is the consistent solution. Fast Service VL circuit breakers get by with just a few standard parts, making it easier to get devices and components. That means that you find what you are looking for quicker at your dealer or you can reduce your own inventory costs. Time Savings If time is money, Siemens VL will save you a lot. One example is the quick installation by simple connection of the main line. Another is the simple maintenance. Internal accessories are accessible without special tools and, as far as the life expectancy is concerned, VL circuit breakers are designed to exceed market standards.

Backed by Siemens Innovation and Technology Siemens VL Circuit Breakers are designed on the principal of contact magnetic repulsion. This allows the current limiting effect of the breakers to help protect the system components from the thermal and dynamic magnetic effects of short circuit currents in the event of an electrical fault. VL Circuit Breakers feature N-Class (35kA), H-Class (65kA) and L-Class (100kA) interrupting ratings. They also feature both thermal magnetic and electronic trip units across the entire product line, assuring compatibility for virtually any application. All of the VL Trip Units are UL listed for field installation and measure true RMS current. This type of measurement ensures the most accurate means of measuring currents in today s harmonic filled electrical distribution systems. VL Trip Units are available for the following applications: Line Protection overload and short-circuit curves are matched to protect cables, wiring and non-motorized loads. Motor Circuit Protection equipped with adjustable instantaneous short circuit protection, trip characteristics are designed for optimum protection and isolation in combination starter applications (consisting of a motor circuit protector, contactor, and overload relay). Non-automatic Circuit Breaker (MCS) can be used as supply, main or non-automatic switches without overload protection. They are fitted with fixed instantaneous settings. Siemens VL Trip Unit Technology N/H/L Class, Model 525 Thermal Magnetic Trip Units: Ideal for line protection Fixed overload protection Adjustable short-circuit protection N/H/L Class, Model 545, Electronic Trip Units: Flashing green LED indicates proper operation Yellow LED for overload status Integrated self-test function Operates without the need for auxiliary voltage Plug-in socket for field testing device N/H/L Class, Model 576, Electronic LCD Trip Units: Integral LCD display User-friendly, menu-driven setting of protection parameters directly in absolute ampere values Integrated self-test function Operates without the need for auxiliary voltage when the breaker is under load Plug-in socket for field testing device Thermal memory function, selectable on/off Fully adjustable LSI and LSIG settings for flexible coordination Connects to communication modules Tool Set: Electronic catalog Easy breaker selection Bill of material generator Technical documentation Automated breaker cross-reference PC-based time current curve software program Internet links with easy to use navigation Technical database Multi-formatted breaker drawings (CAD or PDF) Product specifications in customizable formats for easy submittals Circuit breaker catalog Circuit breaker information guide (technical data) Product video PowerPoint presentations

Competitive Advantages To Reduce Your Installed Cost The compact size saves real estate and its associated costs. The modularity and flexibility reduce inventory, allow for last minute changes, support quick ship opportunities, and promote the most cost effective configuration. Global ratings, accessories, and distribution allow you to efficiently serve virtually every market using breakers with just one design and footprint. The intuitiveness and ease of use eliminate the need for special training and significantly reduce installation time. Operations Breaker 20,000 DG150 FG250 JG400 Approval pending. For higher reliability, most VL components have twice the endurance specified by UL. Automated bar code tracking, testing, and calibration of every breaker saves money on confirmation tests and field service. 10,000 8,000 6,000 Typical 100A Typical 225A Typical 600A

Breaker Frame Family DG FG JG Interrupting Rating (ka) RMS Symmetrical Amperes AC 50/60Hz DC Interrupting Ratings (UL) Dimensions in inches Continuous Amps I N 50 150 A 70 250 A 250 400 A Current Rating I r 30 150 A 40 250 A 70 400 A Poles 2, 3, 4 2,3,4 2, 3, 4 Max. Volts AC 600 V 600 V 600 V Breaker Type NDG HDG LDG NFG HFG LFG NJG HJG LJG Interrupting Class N H L N H L N H L 240Vac 65 100 200 65 100 200 65 100 200 UL 480Vac 35 65 100 35 65 100 35 65 100 600Vac 18 20 25 18 20 25 25 25 25 220/240Vac (I cu /I cs ) 65/65 100/75 200/150 65/65 100/75 200/150 65/65 100/75 200/150 IEC 380/415Vac (I cu /I cs ) 40/40 70/70 100/75 40/40 70/70 100/75 45/45 70/70 100/75 690Vac (I cu /I cs ) 12/6 12/6 12/6 12/6 12/6 12/6 12/6 15/8 15/8 250Vdc (2-pole) 30 30 30 30 30 30 30 30 30 500Vdc (3-pole) 18 18 18 18 25 18 25 35 35 600Vdc (3-pole) 750Vdc (4-pole) 2-pole 6.9 H x 4.1 W x 3.4 D 6.9 H x 4.1 W x 3.4 D 11 H x 5.5 W x 4.2D 3-pole 6.9 H x 4.1 W x 3.4 D 6.9 H x 4.1 W x 3.4 D 11 H x 5.5 W x 4.2D 4-pole 6.9 H x 5.5 W x 3.4 D 6.9 H x 5.5 W x 3.4 D 11 H x 7.2 W x 4.2D Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Electronic Electronic Electronic Trip Unit Information Electronic with LCD Electronic with LCD Electronic with LCD Interchangeable Trip Unit Interchangeable Trip Unit Interchangeable Trip Unit Communications Capability Communications Capability Communications Capability Molded Case Switch Molded Case Switch Molded Case Switch Specific Application Breakers Motor Circuit Protector Motor Circuit Protector Motor Circuit Protector 100% Rated 100% Rated 100% Rated 50ºC Calibrated 50ºC Calibrated 50ºC Calibrated Auxiliary Switch Auxiliary Switch Auxiliary Switch Alarm Switch Alarm Switch Alarm Switch Shunt Trip Shunt Trip Shunt Trip Undervoltage Release Undervoltage Release Undervoltage Release Mechanical Interlock Mechanical Interlock Mechanical Interlock Electric Motor Operator Electric Motor Operator Electric Motor Operator Accessories & Modifications Rear Connecting Studs Rear Connecting Studs Rear Connecting Studs Plug-in Mounting Assy. w/trip Interlock Plug-in Mounting Assy. w/trip Interlock Plug-in Mounting Assy. w/trip Interlock Draw-out Assembly Draw-out Assembly Draw-out Assembly Handle Mechanisms Handle Mechanisms Handle Mechanisms Fungus Proof Fungus Proof Fungus Proof NEMA 1 Indoor, Surface Mount NEMA 1 Indoor, Flush Mount Enclosures NEMA 3R Outdoor, Rain Proof NEMA 4/4X Stainless Steel NEMA 7, 9 Hazardous Locations NEMA 12 Dust Thermal Shields Distribution Lugs Ground Sensor (Neut. Trans) Approval pending. Consult Siemens. Communications available via communications module. Not UL listed. VL circuit breakers are inherently fungus resistant.

LG MG NG PG 400 600 A 600 800 A 800 1200 A 1200 1600 A 150 600 A 200 800 A 200 1200 A 400 1600 A 2, 3 2, 3, 4 2, 3,4 3, 4 600 V 600 V 600 V 600 V NLG HLG LLG NMG HMG LMG NNG HNG LNG NPG HPG LPG N H L N H L N H L N H L 65 100 200 65 100 200 65 100 200 65 100 200 35 65 100 35 65 100 35 65 100 35 65 100 25 25 25 25 35 50 25 50 65 25 50 65 65/65 100/75 200/150 65/65 100/75 200/150 65/35 100/50 200/100 65/35 100/50 200/100 45/45 70/70 100/75 50/50 70/70 100/75 50/25 70/35 100/50 50/25 70/35 100/50 12/6 15/8 15/8 20/10 30/15 35/17 20/10 30/15 35/17 20/10 30/15 35/17 30 30 30 22 25 42 22 25 42 22 25 42 25 35 35 35 50 65 35 50 65 35 50 65 11 H x 5.5 W x 4.2 D 16 H x 7.5 W x 4.7 D 16 H x 9 W x 6.2 D 11 H x 5.5 W x 4.2 D 16 H x 7.5 W x 4.7 D 16 H x 9 W x 6.2 D 16 H x 9 W x 6.2 D 16 H x 10 W x 4.7 D 16 H x 12 W x 6.2 D 16 H x 12 W x 6.2 D Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Thermal-Magnetic Electronic Electronic Electronic Electronic Electronic with LCD Electronic with LCD Electronic with LCD Electronic with LCD Interchangeable Trip Unit Interchangeable Trip Unit Interchangeable Trip Unit Interchangeable Trip Unit Communications Capability Communications Capability Communications Capability Communications Capability Molded Case Switch Molded Case Switch Molded Case Switch Molded Case Switch Motor Circuit Protector Motor Circuit Protector 100% Rated 100% Rated 100% Rated 50ºC Calibrated 50ºC Calibrated 50ºC Calibrated 50ºC Calibrated Auxiliary Switch Auxiliary Switch Auxiliary Switch Auxiliary Switch Alarm Switch Alarm Switch Alarm Switch Alarm Switch Shunt Trip Shunt Trip Shunt Trip Shunt Trip Undervoltage Release Undervoltage Release Undervoltage Release Undervoltage Release Mechanical Interlock Mechanical Interlock Mechanical Interlock Mechanical Interlock Electric Motor Operator Electric Motor Operator Electric Motor Operator Electric Motor Operator Rear Connecting Studs Rear Connecting Studs Rear Connecting Studs Rear Connecting Studs Plug-in Mounting Assy. w/trip Interlock Plug-in Mounting Assy. w/trip Interlock Plug-in Mounting Assy. w/trip Interlock Draw-out Assembly Draw-out Assembly Draw-out Assembly Draw-out Assembly Handle Mechanisms Handle Mechanisms Handle Mechanisms Handle Mechanisms Fungus Proof Fungus Proof Fungus Proof Fungus Proof

Modularity To Support All Your Application Needs Modules and More: VL Circuit Breakers with Optional Accessories 9 2 8 7 1 10 6 5 4 3 11 15 14 21 16 12 17 18 19 20 6 13 5 4 3 8 7 2 1 2 3 4 5 6 7 8 Base for Plug-In or Draw-Out Interphase Barriers Rear Terminals Flat and Round Bus Extensions Terminal Connectors Plug-In Terminal Blades Extended Terminal Shield Standard Terminal Shield 9 10 11 12 13 14 15 16 Cover Frame for Door Cutout Stored Energy Operator Rotary Handle Operator Variable Depth Rotary Operator Max Flex Operator Circuit Breaker Shunt Trip or Undervoltage Releases Auxiliary/Alarm Switches 17 18 19 20 21 Thermal-Magnetic Trip Unit (525) Electronic Trip Unit (545) Electronic Trip Unit with LCD (576) Communication Module with ZSI Electronic Trip Unit Test Kit

Siemens VL Molded Case Circuit Breakers Guide Form Specifications General Specifications Siemens molded case circuit breakers shall be provided for the protection of all electrical circuits. Other makes of molded circuit breakers will not be accepted unless approved by this office. All circuit breakers shall be listed by Underwriter s Laboratories, as well as comply with International Electrotechnical Commission IEC 60 947-2, Canadian Standards Assoc. C22.2, applicable requirements of NEMA Standard publication AB-1. All circuit breakers shall have a quick-make, quick-break over center toggle-type mechanism and the handle mechanism will be trip-free to prevent holding contacts closed against a short circuit or sustained overload. All circuit breaker handles shall assume a position between ON and OFF when tripped automatically. Breaker is suitable for isolation, and the handle will only remain in the OFF position if the contacts are actually separated. All circuit breakers shall be of modular design and have available interchangeable trip units. The trip unit will define the nominal current rating of the complete breaker and no rating plugs will be required. For the protection and coordination for all circuits, 30A through 1600A, thermalmagnetic, electronic and electronic with integral LCD display type trip units must be available. For all frame sizes, available mounting configurations shall include fixed, draw-out, and plug-in with trip interlock. Thermal Magnetic Trip Specification Choose either thermal-magnetic or electronic trip specifications Each circuit breaker shall operate automatically by means of a thermalmagnetic trip unit providing inverse time delay for overload protection and a magnetic instantaneous trip for short circuit protection. The instantaneous magnetic trip shall be adjustable and set from the front of the trip unit. Electronic Trip Specification Each circuit breaker shall operate automatically by means of an electronic trip unit sensing true RMS current. Depending on the trip unit selected, adjustable Continuous Amps, Long Time Pick-up and Delay, Short Time Pick-Up and Delay, Instantaneous Trip and Ground Fault trip functions will be available. The settings shall be made from the front of the trip unit. A red LED will flash continuously to confirm operation of the microprocessor and a yellow LED will indicate overload status. Built-In LCD Type (Optional) Electronic trip units shall also include an integral LCD that will continuously display the current in each phase. The display can show breaker set points, option menus and list the date, time and current of the latest trip event. In addition, the Ground Fault setting shall be programmable and a Ground Fault Time Delay function shall be included. Instantaneous Only Trip Specifications (Optional) Where indicated on the drawings or the combination motor starter/motor control schedule, furnish instantaneous magnetic trip only circuit breakers for motor short circuit protection. The magnetic trip setting shall be adjustable from the front of the breakers. Internal Accessories All internal accessories shall be field installable using a snap-in-place method and will be mounted in an isolated pocket inside the front cover of the breaker, away from the internal power conductors and operating mechanism. Auxiliary and Alarm switches shall be of one style that can be used across all frame sizes. Shunt trips and under voltage releases shall be available in two groupings by frame size, up to 600A and from 800A through 1600A. Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.sea@siemens.com www.sea.siemens.com/power 2006 Siemens Energy & Automation, Inc. All Rights Reserved Siemens is a registered trademark of Siemens AG. Product names mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice. CBCM-VLFBG-0306 New 10M0306B&A Printed in USA