Test report No

Similar documents
Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Test report No

Test report no

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report No

Test report no

Test Report No

Classification report No K1

Test report no

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

Sound-absorbing spacer Sorp10

Report Test Report

FIRE TEST REPORT FH 5154

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

Determination Of Fire Effluents From Products On Railway Vehicles

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT TABLE FOR AMBULANCE STRETCHER

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Confirmation: / 22 March 2013

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

EU Mutual Recognition Technical Requirements

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

FIRE TEST REPORT FH 5728

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

EC type-examination of SITEMA Safety Brakes by DGUV Test

Product Information. Bayferrox 640. Description. Specification. Brown pigment

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

FLASH POINT TESTER. Instruction Manual. 0. Health and Safety Advice. 1. Introduction

Product Information. Description. Specification

Black pigment - High Performance micronised. Synthetic iron oxide Fe 3 O 4 Pigment black 11 (77499)

MITRAS MATERIALS GMBH

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT AMBULANCE STRETCHER

Synthetic iron oxide α - Fe 2 O 3 Pigment red 101 (77491)

DNVGL-CP-0110 Edition March 2016

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Test report. About the effect of Lambda System Cleaning Products. No

DEUTSCHE NORM DIN 8077

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Technical information No. 01. IT systems. The basis for reliable power supply

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

National Standard of People s Republic of China

Product information. COLORTHERM Red 110 M. Description. Specification. Specification. Red pigment

Product information. COLORTHERM Yellow 30. Description. Specification. Specification. Yellow pigment

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Brown pigment - High Performance, special with high thermal stability

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Test Report Order No _A1 / Part Hessisch Oldendorf. Order: Test of the electrostatic properties of a resilient floor coverings coated

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

20 HUBER+SUHNER RADOX SOLAR

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

Vertex Floors Ltd. Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay. P.R. China. Berlin, den

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

GEZE TS 4000 E. Overhead door closer with electrohydraulic hold-open according to EN 1155, closing force size 1-6.

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

This test report describes the test results of the below mentioned paragliding harness. Ozone Gliders Ozium Medium 1.

Approval mark PL HCR 1a A

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

KAIFLEX PRODUCT BROCHURE

FIRE TEST REPORT FH 5078

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

FIRE REGULATION IN FURNITURE WORLD OVERVIEW

DEUTSCHE NORM DIN Passverzahnungen mit Evolventenflanken und Bezugsdurchmesser Teil 2: Nennmaße und Prüfmaße

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

EEA AGREEMENT - ANNEX XIII p. 99 APPENDIX 2 { 1 }

InnoBYG small scale demonstration tests - Part 1

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

Test Report No

LEGAL REQUIREMENTS FOR TRANSPORT AND DISPOSAL OF HAZARDOUS WASTE IN THE ERA OF WASTE CLASSIFICATION

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

DECLARATION OF CONFORMITY REGARDING RESTRICTIONS OF HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

No carcinogenic nitrosamine generating raw materials are used.

Trailer EBS E 98/91/EG dated ECE-R 105 including amendment 04 and Chapter ADR 2009

HST -LS Interlocking device (Translation of Original Manual)

Transcription:

Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2296 for applying of a required Verwendbarkeitsnachweis issued 25.01.2010 Applicant: Hewlett Packard Company 16399 West Bernardo Drive San Diego SA 92127 USA Date of order: 18.11.2009 Date of sampling: no official taking out of the sample from a representative of the Bodycote Warrington Brandhaus Date of arrival: 23.11.2009 Date of test: 10.12.2009 + 22.01.2010 Order Testing of the flammability (building class B1) according to DIN 4102-1 (Mai 1998) Description / designation of the test object HP Light Display fabric, CH006A Description of the relevant test procedure DIN 4102 Teil 1 (Mai 1998) This test report did replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713 19.05.2010

Test report No. 2009-2296 issued 25.01.2010 page 2 fom 9 1. Description of the test material 1.1 Details of the customer: HP Light Display fabric, CH006A Construction: none Details 1.2 At the sample preparation in the Exova Brandhaus determined values: Pattern. Colour: Weight: white 193 g/m² The samples were stored before testing under climatic conditions (23 C / 50 % rel. humidity).

Test report No. 2009-2296 issued 25.01.2010 page 3 fom 9 2. Test results 2.1 Brandschachtprüfung nach DIN 4102-1 Sample A: fabric tested in production direction Sample B: fabric tested crosswise to the production direction Test results of the Brandschacht tests part 1 line Measurements test sample no. A B C 1 no. test arrangement according to DIN 4102 part 15, table 1 1 2 flame height max. over lower sample edge cm 30 30 time 1) 0:08 0:10 3 ascertainments on the front side Flaming/glowing 0:02 0:03 time 1) 4 melting / burning through time 1) 0:06 0:04 ascertainments on the back side 5 Flaming/glowing no no time 1) 6 discolouring time 1) burning droplets 7 begin 1) extent 8 occasional droping of material 9 constant droping of material 10 11 12 separating from burning sample parts begin 1) occasional separating parts constant separating parts 13 duration of burning on the sieve tray (max.) influnce on the burner flame by droping of / separating material 14 time 1) earlier end of test 15 end of the fire scenario on the sample 1) 16 time of a possible resulted test stop 1) no no 1) time from start of test

Test report No. 2009-2296 issued 25.01.2010 page 4 fom 9 Test results of the Brandschacht tests part 2 line Measurements test sample no. A B C flaming after end of test 17 duration 18 number of sample 19 front side of sample 20 backside of sample 21 flame length cm 22 23 24 25 26 27 glowing after end of test duration number of sample place of occurrence lower sample part upper sample part front side of sample backside of sample min. s 28 29 30 smoke density < 400 % x min 1 3 > 440 % x min diagram in annex no. 1 2 31 32 33 34 35 36 residual length single results average of the single results foto of the sample on page smoke temperature max. of the average results time 1) diagram in annex no. cm cm C 70 / 71 69 / 71 72 / 70 70 / 71 70 70 5 5 116 116 8:35 9:26 1 1 1) time from start of test Remarks:.

Test report No. 2009-2296 issued 25.01.2010 page 5 fom 9 Appearance of sample A after the Brandschacht test Appearance of sample B after the Brandschacht test

Test report No. 2009-2296 issued 25.01.2010 page 6 fom 9 2.2 Normal flammabilty test according to DIN 4102-1 Test with edge ignition without deposit Flame application on: lower sample edge Test direction: in direction of production Sample-no. Time from start of test 1 2 3 4 5 Ignition point [s] - - - - - Reaching the measuring mark within 20 seconds no no no no no Self extinguishing of the flame [s] 3 3 3 3 3 Max. flame height [mm] 30 30 30 30 30 Time [s] 3 3 3 3 3 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material no no no no no Time [s] - - - - - Remarks: none in cross direction: Sample-no. Time from start of test 1 2 3 4 5 Ignition point [s] - - - - - Reaching the measuring mark within 20 seconds no no no no no Self extinguishing of the flame [s] 2 2 2 2 2 Max. flame height [mm] 20 20 20 20 20 Time [s] 2 2 2 2 2 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material no no no no no Time [s] - - - - - Remarks : none

Test report No. 2009-2296 issued 25.01.2010 page 7 fom 9 Appearance of the sample after the small burner test:

Test report No. 2009-2296 issued 25.01.2010 page 8 fom 9 Assessment The in chapter one described material fulfils the requirements of the building class B2 according to DIN 4102-1 (Mai 1998). The determined test results show that the material fulfils also the requirements of the building class according to DIN 4102-1 (Mai 1998). B1 Special comment The fire test result is only valid for the in chapter one described material, in the tested thicknesses, square weights and colours, in free hanging configuration,. The distance to other plane material must be more then 40 mm. In accordance to the experience of the test institute the test result is also valid for the colour amongst. The material wasn't tested after an outside storage. In combination with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable so that the classification above is valid any longer. According to DIN 4102-1 the burning behaviour in combination with other materials has to be tested separately. This test certificate did replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Frankfurt, the 25.01.2010 H. Anders / H. Schmid Dipl.-Ing. T. Zachäus Tester in charge Laboratory Supervisor This Test report is valid until 09.12.2014. The results of the tests relate only to the behaviour of the test sample which is designated on the top. Test reports are only allowed to be published or reproduced, changed in form and tenor without permission of the Exova Brandhaus. The abridged account of a test report is only allowed with the agreement of the Exova Brandhaus. This Test report is a translation of the German version 2009-2296 (issued 25.01.2010). In case of doubt only the German version is valid This test report contains 8 pages and 2 annexes.

Annex 1 to the Test report No. 2009-2296 dated 25.01.2010 Sample A:

Annex 2 to the Test report No. 2009-2296 dated 25.01.2010 Sample B: