A Series Variable Displacement Piston Pumps

Similar documents
AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps. AR Series Variable Displacement Piston Pumps

A Series Variable Displacement Piston Pumps. A16 Type performance characteristics A16 Type Noise level characteristics.

" " Series Variable Displacement Piston Pumps

" " Series Variable Displacement Piston Pumps

VARIABLE DISPLACEMENT PISTON PUMPS

ARL1 Series Piston Pumps. ARL1 Series Piston Pumps. Geometric Displacement. Maximum cm 3 /rev

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22- FR01 3

"AR" SERIES PISTON PUMPS. Variable Displacement-Single Pumps Pressure Compensator Type,AR16 / AR22-FR01

"A" Series Variable Displacement Piston Pumps Single Pump, Pressure Compensator Type

PISTON PUMPS. A3H Series High Pressure Variable Displacement Piston Pumps. Features. A3H Series Variable Displacement Piston Pumps.

AR Series Variable Displacement Piston Pumps. [Comparison of AR16 with A16 ] A16,32 Design 188. AR16,22 Design 130. Ratio of Mass (AR16/A16) 74%

Variable Displacement Piston Pumps

Series Variable Displacement Piston Pump

Series Proportional Electro-Hydraulic Controls

VANE PUMPS. Output Flow at 1200 r/min at No-Load U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols.

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090

Hydraulic Fluids. Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

Proportional Electro-Hydraulic Flow Control (and Check) Valves

FLOW CONTROLS. Maximum Flow U.S.GPM Maximum Operating Pressure MPa (PSI) Graphic Symbols. Page. Valve Type.

50T,150T,250F SERIES Fixed Displacement-Single, Double, Combination 3

"A" Series Piston Pumps Variable Displacement-Single Pumps Electro-Hydraulic Proportional Pressure & Flow Control. Type

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

PROPORTIONAL ELECTRO-HYDRAULIC CONTROLS

UNLOADING RELIEF VALVES

"PV11R" SERIES Fixed Displacement- Single PV11R10/PV11R20

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

Proportional Electro-Hydraulic Relieving and Reducing Valves

Proportional Electro-Hydraulic Pilot Relief Valves

Proportional Electro-Hydraulic Directional and Flow Control Valves

PRESSURE REDUCING AND RELIEVING VALVES

SHUT-OFF TYPE SOLENOID OPERATED DIRECTIONAL VALVES DSPC/DSPG-01/03(1/8,

EH SERIES PROPORTIONAL ELECTRO-HYDRAULIC CONTROL VALVES

PRESSURE REDUCING AND RELIEVING VALVES

06 SERIES MODULAR VALVES. Pub. EC-1404

Direct Operated Type Directional and Flow Control Valves

Proportional Electro-Hydraulic Flow Control and Relief Valves

2.3 MEDIUM HEAVY DUTY SERIES

2.4 HEAVY DUTY SERIES

PROPORTIONAL ELECTRO-HYDRAULIC CONTOROLS

4.2 FIXED DISPLACEMENT DOUBLE PUMP

Max. Reversed Free Flow. Max. Operating. Pressure MPa (PSI) Fine Feed 20 (5.3) 14 (2030) 40 (10.6) ( ) 40 (10.6) (

Pub.EC Series

Pilot Operated Flow Control Valves / Pilot Operated Flow Control and Check Valves

High Pressure, High Flow Rate Modular Valves

Pressure Reducing and Relieving Valves

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

Restrictors / One Way Restrictors

E SERIES. Proportional Electro-Hydraulic Relief Valves. Specification. Model Number Designation. Attachment Mounting Bolts

10 SERIES MODULAR VALVES

EMulti Purpose Control Valves

V Series AXIAL PISTON PUMP ORDER CODE

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

Solenoid Pilot Operated Proportional Directional Control Valve

Proportional Electro-Hydraulic Flow Control (and Check) Valves

Max. Reversed Free Flow L/min

Poppet Type Directional Valves

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

10 SERIES MODULAR VALVES. Pub. EC-1405

Modular Valves. Ratings

EHBG-03 EHBG-06 EHBG-10. Refer to Model No. Designation. 2% or Less(1%) 1% or Less *2. Refer to frequency Response on page V DC

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

V Series AXIAL PISTON PUMP ORDER CODE

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Axial piston pumps type PVPC with ISO mounting flange variable displacement, hydraulic control

Flow Control Valves / Flow Control and Check Valves

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

P2060 P2075 P2105 P2145 P3105 P3145

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

Variable displacement axial piston pumps,

Variable displacement axial piston pumps,

Max. Operating Pressure Kgf/cm 2

1.3 HIGH PRESSURE SERIES

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

MOTOR-PUMPS PAL PUMPS. M Series Electric Motors. M Series Electric Motors 212. PAL PUMPS & M Series Electric Motors. Maximum Operating Pressure MPa

PCP Series Piston Pumps - Industrial

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Axial piston pumps type PVPC variable displacement, by a full line of mechanical controls

High Pressure, High Flow Rate Modular Valves

Proportional Valve.

Variable Displacement Piston Pumps for Industrial Applications

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

EManually Operated Directional Valves

Solenoid Controlled Relief Valves

03 SERIES. General Information Mounting Surface : ISO 4401-AC-05-4-A, CETOP-5, NFPA-DO2 Up to 25 MPa (3630 PSI), 70 L /min (18.5 U.S.

Variable displacement axial piston pump type V30D

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

EManually Operated Directional Valves

Variable Displacement Piston Pumps PISTON PUMP

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Transcription:

A Series Variable Displacement Piston Pumps A37 A56 A1637 A16 A10 A Series Variable Displacement Piston Pumps Pump Type Graphic Symbol Geometric Displacement cm 3 /rev 1 5 10 0 50 100 00 300 Maximum Operating Pressure MPa Page A10 A16 1 A 16 A37 1 1 Single Pumps Double Pumps Outboard Pump Inboard Pump A45 A56 A70 A90 A100 A145 A0 A16 A37 A56 A70 A0 A16 A37 A56 A145 A90 16 1 8 1 8 16 8 8 110 Variable/Fixed Double Pumps Outboard Pump Inboard Pump PVR1 PVR A70 A0 A16 A37 A56 A145 A90 8 11 1 Various control types are available such as pressure compensator type. Refer to page 9 and 30. The maximum operating pressure for each double pump depends on its combination of pumps. Contact us for details. 5

Hydraulic Fluids Hydraulic Fluids Use petroleum based oils such as anti-wear type hydraulic oils equivalent to ISO VG-3 or 46. The recommended viscosity range is from 0 to 400 mm /s and temperature range is from 0 to, both of which have to be satisfied for the use of the above hydraulic oils. Control of Contamination Due caution must be paid to maintaining control over contamination of the operating oil which can otherwise lead to breakdowns and shorten the life of the unit. Please maintain the degree of contamination within NAS Grade 10. The suction port must be equipped with at least a 100 μm (150 mesh) reservoir type filter and the return line must have a line type filter of under 10 μm. Instructions Mounting When installing the pump the filling port should be positioned upwards. Alignment of Shaft Employ a flexible coupling whenever possible, and avoid any stress from bending or thrust. Maximum permissible misalignment is less than 0.1 mm TIR and maximum permissible misangular is less than 0.. Suction Pressure Permissible suction pressure at inlet port of the pump is between -16.7 and +50 kpa. For piping to the suction port, use the pipes of the same diametre as that of the specified pipe flange to be used. Make sure that the height of the pump suction port is within one metre from the oil level in the reservoir. Hints on Piping When using steel pipes for the suction or discharge ports, excessive load from the piping to the pump generates excessive noise. Whenever there is fear of excessive load, please use rubber hoses. Suction Piping In case the pump is installed above the oil level, the suction piping and suction line filter should be located lower than the pump position to prevent air in the suction line. When using steel pipes for the suction or discharge ports, excessive load from the piping to the pump generates excessive noise. Whenever there is fear of excessive load, please use rubber hoses. Drain Piping Install drain piping according to the chart and ensure that pressure within the pump housing should be maintained at a normal pressure of less than 0.1 MPa and surge pressure of less than 0.5 MPa. Length of piping should be less than 1 m, and the pipe end should be submerged in oil. Model [Recommended Drain Piping Size] Fitting Size Inside Dia. of Pipe 3/8 A10, A16, A 10 mm or more [Inside Dia. 8.5 mm or more] A37, A45 A56, A70, A90, A100, A145 1/ [Inside Dia. 1 mm or more] 3/4 [Inside Dia. 16 mm or more] 1 mm or more 19 mm or more Bleeding Air It may be necessary to bleed air from pump case and outlet line to remove causes of vibration. An air bleed valve (Model Number ST1004-* -10 *, Page 65) is recommended for this purpose. 6

PISTON PUMPS Starting Before first staring, fill pump case with clean operating oil via the filling port. In order to avoid air blockage when first starting, adjust the control valves so that the discharged oil from the pump is returned direct to the reservoir or the actuator moves in a free load. [Volume of Pre-fill Oil Required] Setting Discharge Pressure and Delivery At the time of shipment, the unit has been preset to maximum delivery and minimum discharge pressure. Adjust the preset delivery and pressure to meet your system requirements. Adjustment of Discharge Pressure Turning the adjustment screw clockwise, increases pressure. A Series Model A10 A16/A A37/A45/A56 A70 A90/A100 A145 Volume cm 3 370 0 100 100 500 3300 Volume adjusted by each full turn of the pressure adjustment screw Model Numbers A10-FR01B A10-FR01C/H A16/A/A37/A56--R-01-B A16/A/A37/A56--R-01-C A16/A37/A56--R-01-H A70/A90/A100/A145--R01B A70/A90/A100/A145--R01C A70/A90/A100/A145--R01H A70/A90/A100/A145--R01K Adjustment Volume MPa.9 5.4 3.5 6.5 7.9.3 3. 4.0 4.7 Adjustment of Delivery Turning the flow adjustment screw clockwise, decreases delivery. The minimum adjustable flow and adjustable volume of each full turn of the delivery adjustment screw Model Adjustable volume with each full turn of the adjustment screw 3 cm /rev Minimum adjustment flow 3 cm /rev A10 A16 A A37 A56 A70 A90 A100 1.1 1.4.0.9 3.9 4.4 4.8 5..0 4.0 6.0 10 1 36 56 6 A145 7. 83 7

Spool Control Piston Drain Port Pressure Adj. Screw Flow Adj. Screw Pivot Shaft OUT IN Yoke Port Plate Cylinder Block Piston Ass'y Spring, Yoke Return Swash Plate Slipper Retainer Features High efficiency The efficiency properties in case of A16 from are high efficiencies to be shown below. Low noise level In the A16 pump, the noise level is as low as 57.3 db(a) [at the full cut-off pressure 1 MPa with speed 1500 r/min one metre horizontally away from pump head cover.] A16 type performance characteristics Volumetric Efficiency Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Noise Level Full Cut-off Pressure Pressure Accomplishment of energy-saving Because the overall efficiency is high and the cut-off characteristics is sharp, thus the input power may be saved. Low heat generation Because of small power loss, it is possible to reduce the rise in oil temperature. Accordingly, capacity of a reservoir can be reduced. 8

PISTON PUMPS Control Type Control Type Graphic Symbols Performance Characteristics Explanation Page "01" Pressure Compensator Type M O Output Flow Pressure When the system pressure increases and comes close to the preset cut-off pressure, the pump flow decreases automatically while maintaining the set pressure as it is. 31 A Series "0" Solenoid-two Pressure Control Type PL PH M O Output Flow SOL "OFF" PL Pressure SOL "ON" PH This type of control is ideal for an application where the output power of the actuator has to be controlled in two different load pressures while keeping the actuator speed nearly constant. 53 "03" Pressure Compensator with Unloading Type M O Output Flow SOL "OFF" Pressure SOL "ON" It is suitable for a situation where a long unloading time is required and heat generation and noise have to be kept at their lowest levels. The pump can be used in combination with the multistage pressure control valve. 61 "04" Proportional Electro- Hydraulic Load Sensing Type i 1 M O i (S Input Current i L) Output Flow Pressure (S Input Current i1 L) This is an energy-saving type control which regulates the pump flow and load pressure to be at absolute minimum necessary level to operate the actuator. Pump flow rate and cut-off pressure are controlled proportional to the input current to the control device on the pump and the input current is regurated by the specific amplifier. 6 "04E" "04EH" Electro- Hydraulic Proportional Pressure & Flow Control Type Electro- Hydraulic Proportional Pressure & Flow Control Type (OBE Type) M O (S Input Voltage L) Output Flow Pressure (S Input Voltage L) This type of control has the pressure sensor and tilt angle sensor in the pump. The pump is used with the external amplifier (amplifier is integrated into pump in case of "04EH"). Flow and pressure can be controlled in proportion to input voltage by only one control valve. The features has been greatly improved by electrical feedback of swash plate tilt angle correspond to flow rate and load pressure to control valve. Linearity of input characteristics is excellent and easy to set. Hysteresis is lower, repeatability and reproducibility are fine. 7 8 "05" Two-Pressure Two-Flow Control Type by System Pres. PH PL M O Output Flow QH QL PL Pressure PH This type of control is suitable for an application like "Presses" where the changeover from rapid advance to feed is required just when the pressing (pressurizing) starts. 91 "06" Two-Pressure Two-Flow Control Type by Solenoid Valve PL PH M O Output Flow SOL"OFF" QH SOL"ON" QL PL PH Pressure This pump control is suitable for machining found on machine tool, where machining starts after the changeover from rapid advance, to feed has been made. 9 9

Control Type Control Type Graphic Symbols Performance Characteristics Explanation Page "07" Pilot Pressure Control Type Pressure Compensator M O Output Flow Pressure The pump is used in combination with the pilot relief valve or multistage pressure control valve. By controlling the pilot pressure, the full cut-off pressure can be remote-controlled according to your requirements. 93 Output Flow Pump input power can be controlled in accordance with the motor output. "09" Constant Power Control Type M O Output Flow Pressure Input Power When the discharge pressure rise, the output flow decreases corresponding to the preset input power. The pump can act for function of two pumps, lowpressure large-flow and high-pressure small-flow. Therefore, the motor capacity can be reduced. 101 This type of control enables one pump to act as two pumps (low-pressure and large-flow/high-pressure and small-flow-rate). Therefore, the motor capacity can be reduced. "00- Z500" Simple Two- Pressure Two-Flow Control Type When the system pressure increases near the preset PL pressure due to the load increase, the pump flow automatically decreases to QL. This type of control is suitable for an application like the press, where switching from rapid advance to feed is required just when the press (pressurizing) starts. The PH pressure can be remote-controlled with a separately located relief valve. With this type of control, it is easy to change the applied pressure setting when materials or shapes of the press are changed. 109 Availability of Control Type Mark " " in the table below refers to standard model. Model Geometric Control Type Numbers Displacement cm 3 /rev 01 0 03 04 04E 04EH 05 06 07 09 00-Z500 A10 10.0 A16 15.8 A. A37 36.9 A45 45.0 A56 56. A70 70.0 A90 91.0 A100 100 A145 145 A0 19 30

PISTON PUMPS, Pressure Compensator Type Graphic Symbol A Series Applicable only for A00 Specifications Model Numbers Geometric Displacement cm 3 /rev Minimum Adj. Flow cm 3 /rev Operating Pressure MPa 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. 3. Care should be taken in cases of used at a higher pressure than the rated pressure, because operating terms may be restricted. For example, if used as per maximum illustrated operating conditions, intermittent time at maximum flow is restricted to under 1/5 of one cycle time and under six seconds simultaneously. Conditions may vary according to the actual working pressure and delivery (inclination angle of the swash plate). Consult factory or Yuken sales representative for further information. Shaft Speed Range r/min Approx. Mass kg Rated Intermittent 1 Max. Min. Flange Mtg. Foot Mtg. A10-FR01B-1 5.1 10.0 16 1 1800 0 A10-FR01C/H-1 8.5 A16-*-R-01-*-*-K-3 15.8 4 16 1 1800 0 16.5 18.7 A-*-R-01-*-*-K-3. 6 16 16 1800 0 16.5 18.7 A37-*-R-01-*-*-K-3 36.9 10 16 1 1800 0 8.0 3.3 A56-*-R-01-*-*-K-3 56. 1 16 1 1800 0 35.0 39.3 A70-*R01*S- 70.0 36 5 8 1800 0 58.5 70.5 A90-*R01*S- 91.0 56 5 8 1800 0 7.5 93 A100-*R01*S-10 100 6 1 1 1800 0 7.5 93 A145-*R01*S- 145 83 5 8 1800 0 9.5 117.7 Specifications and Design numbers for Special Fluids Type of Fluids Water- Glycols Phosphate Ester Type Polyol Ester Type Pump Series Operating Pressure MPa Allowable Maximum Shaft Speed r/min Temperature Range C 1. Applicable only for "A70/90/145" Viscosity Range mm /s Design Numbers for Special Fluid Rated Intermittent Rated Max. 16 A16-A56 14 330 (14) 1 100 (1800) 0-50 A70-A145 1 1 30 A100 16 16 1030 0-00 16 A16-A56 14 306 (14) 1 100 (1800) 0- A70-A145 1 1 06 A100 1 1 1006 A16-A56 16 16 3450 A70-A145 1 1 1800 1800 0-0-00 450 A100 1 1 10450 1. The figures in brackets are for A type.. As the specific gravities of water-glycol fluids and phosphate ester type fluids are higher than one, an overhead reservoir is required when pumps are operated at 1400 r/min or more. Output Flow Pressure Max. 0 One Cycle Time 1/5 of One Cycle (Max. 6s) * 0 MPa (7 MPa) 1 MPa (8 MPa) * 1 * 1 31

Model Number Designation A16 -F -R -01 -B -S -K -3 Series Number A16 (15.8 cm 3 /rev) Mounting F: Flange Mtg. Direction of Rotation ( Viewed from Shaft End ) Control Type Pres. Adj. Range MPa B: 1. - 7 C: 1. - 16 H: 1. - 1 B: 1. - 7 C: 1. - 16 A 01: Pressure (. cm 3 /rev) Compensator A37 L: Foot R: Clockwise Type (36.9 cm 3 /rev) Mtg. (Normal) B: 1. - 7 A56 (56. cm 3 /rev) C: 1. - 16 H: 1. - 1 Port Position None: Axial Port S: Side Port Shaft Extension K: Keyed Shaft A70 -F R 01 B S - Series Number A10 (10.0 cm 3 /rev) A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A100 (100 cm 3 /rev) A145 (145 cm 3 /rev) Mounting F: Flange 1 Mtg. F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise (Normal) Control Type 01: Pressure Compensator Type Pres. Adj. Range MPa B: 1. - 7 C:.0-16 H:.0-1 B: 1. - 7 C: 1.5-16 H: 1.8-1 K:.0-8 Port Position Design Number 3 3 3 3 Design Number 1 S: Side Port 1. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit shown below separately. Refer to page 0 for dimensions of the Mtg. bracket. Note: The mounting bracket kit consists of a mounting bracket, two hex. bolts and two plain washer. Mtg. Bracket Kit Numbers Approx. Mass kg LP-1A-10.. Available to supply pump with anti-clockwise rotation (Except A100). Consult Yuken for details. Pipe Flange Kits Pipe flange kits are available. When ordering, specify the kit number from the table below. Pump Model Numbers A16-*-R-01 A-*-R-01 A37-*-R-01 A56-*-R-01 A70-*R01 A90-*R01 A100-*R01 A145-*R01 Name of Port Pipe Flange Kit Numbers Threaded Connection Socket Welding Butt Welding Suction F5-06-A-10 F5-06-B-10 F5-06-C-10 Discharge F5-06-A-10 F5-06-B-10 F5-06-C-10 Suction F5-10-A-10 F5-10-B-10 F5-10-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 Suction F5-1-A-10 F5-1-B-10 F5-1-C-10 Discharge F5-08-A-10 F5-08-B-10 F5-08-C-10 Suction F5-16-A-10 F5-16-B-10 F5-16-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used. Details of the pipe flange kits are shown on page 6. 3

PISTON PUMPS The below pumps are also available. Please consult Yuken. Model Number A45-*-R-01-*-K-10 A0-*-R-01-*-K-10 Maximum Operating Pressure MPa 16 16 Geometric Displacement cm 3 /rev 45.0 19 Shaft Speed Range r/min 0-1800 0-1500 A Series The Circuit and Conditions Circuit Response Characteristics Change in Accordance with Circuits and Operating Conditions. High Pressure Rubber Hose Model Rubber Hose Size A10 1/ 800 mm A16 A 3/4 700 mm A37 A56 3/4 000 mm A70 A90 A100 A145 3/4 3500 mm 3/4 3000 mm + 1-1/4 000 mm Conditions Shaft Speed : 1500 r/min Hydraulic Fluid : ISO VG 3 Oil Oil Temperature : See right table Model A10 - A56 A70 - A145 Oil Temperature 50 (0 mm /s) 40 (3 mm /s) Result of Measurement Pressure Model Full Cut-off Pressure P 1 MPa Pressure at Full Flow P MPa Response Time ms t 1 t Overshoot Pressure P S MPa A10 1 100 75.6 A16 16 38 59 3.6 Time A 16 30 7 5.9 A37 16 40 78 7.8 A56 16 38 88 7.6 A70 5 80 100 7.8 A90 5 3 90 110 7.9 A100 1 3 90 110 8.1 A145 5 3 100 150 8.8 Response time except A16, A, A37 and A56 is measured Yoke travel. 33

Typical Performance Characteristics of Type A10 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Volumetric Efficiency Volumetric Efficiency Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Pressure Pressure Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 34

PISTON PUMPS Typical Performance Characteristics of Type A16 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Input Power Output Flow Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power A Series Pressure Pressure Input Power Input Power Output Flow Full Cut-off Power Full Cut-off Power Full Cut-off Pressure Input Power Drain Drain Output Flow Full Cut-off Pressure Full Flow Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 35

Typical Performance Characteristics of Type A at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Pressure Pressure Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 36

PISTON PUMPS Typical Performance Characteristics of Type A37 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power A Series Pressure Pressure Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 37

Typical Performance Characteristics of Type A56 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Pressure Pressure Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 38

PISTON PUMPS Typical Performance Characteristics of Type A70 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Output Flow Input Power Output Flow Input Power A Series Pressure Pressure Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 39

Typical Performance Characteristics of Type A90 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Efficiency Volumetric Efficiency Overall Efficiency Input Power Output Flow Pressure Output Flow Input Power Input Power Output Flow Pressure Output Flow Input Power Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 40

PISTON PUMPS Typical Performance Characteristics of Type A100 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Overall Efficiency Efficiency Volumetric Efficiency Overall Efficiency A Series Output Flow Input Power Output Flow Input Power Output Flow Input Power Output Flow Input Power Pressure Pressure Input Power Input Power Input Power Output Flow Full Cut-off Power Output Flow Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Noise Level [One metre horizontally away from pump head cover] Pressure Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 41

Typical Performance Characteristics of Type A145 at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Performance Characteristic Curve Efficiency Volumetric Efficiency Input Power Overall Efficiency Output Flow Pressure Output Flow Input Power Efficiency Volumetric Efficiency Overall Efficiency Input Power Output Flow Pressure Output Flow Input Power Input Power Input Power Input Power Output Flow Output Flow Full Cut-off Power Drain Full Cut-off Power Drain Full Cut-off Full Flow Full Cut-off Pressure Pressure Noise Level [One metre horizontally away from pump head cover] Noise Level Full Flow Full Cut-off Noise Level Full Flow Full Cut-off Pressure Pressure 4

PISTON PUMPS Flange Mtg. : A10-FR01* A10-FR01C/H Flow Adj. Screw 13 Hex. Pressure Adj. Screw 13 Hex. DEC. INC. Fully Extended Filling Port 1 ( Hex. Head. Plug Furnished) Fully Extended Drain Port 3 Rc3/8 Thd. A Series Dia. Dia., 3 Suction Port Rc 1/ Thd. 34 Dia. 3.5 Deep Rc 1/ Thd. 34 Dia. 3.5 Deep, 3 Dia. A10-FR01B, 3 Suction Port Rc 1/ Thd., 3 Rc 1/ Thd. 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two suction and discharge ports at your option. Keep the remaining ports plugged. 3. As the tightening torques of suction, discharge and drain port fittings, conform to the below. Name of Port Tightening Torque Nm Suction Discharge 65-75 Drain 40-50 43

Axial Port Type Flange Mtg. : A16-F-R-01-*-K A-F-R-01-*-K Flow Adj. Screw 17 Hex. DEC. Lock Nut 17 Hex. Fully Extended Filling Port 1 ( Hex. Head Plug Furnished) Pressure Adj. Screw Drain Port Rc3/8 Thd. 17 Hex. INC. Dia. Dia. Suction Port 19 Dia. M10 Thd. 17 Deep 8 Places 19 Dia. Dia. 1. Install the pump so that the Filling Port is at the top. Foot Mtg. : A16-L-R-01-*-K A-L-R-01-*-K 1 Dia. Through 4 Dia. Spotface For other dimensions, refer to Flange Mtg.. Side Port Type Flange Mtg. : A16-F-R-01-*-S-K A-F-R-01-*-S-K M10 Thd. 17 Deep (Both Sides) 19 Dia. Rear Side Suction Port 19 Dia. Fully Extended Surface of Suction Port Surface of For other dimensions, refer to Axial Port Type. Foot Mtg. Type:Mounting bracket is common to that of Axial Port Type. 44

PISTON PUMPS Axial Port Type Flange Mtg. : A37-F-R-01-*-K Flow Adj. Screw 17 Hex. DEC. Suction Port 3 Dia. Pressure Adj. Screw 17 Hex. INC. 3 Dia. Lock Nut 17 Hex. M10 Thd. 19 Deep 8 Places Fully Extended Dia. Filling Port 1 ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. Dia. Dia. A Series 1. Install the pump so that the Filling Port is at the top. Foot Mtg. : A37-L-R-01-*-K 14 Dia. Through 8 Dia. Spotface For other dimensions, refer to Flange Mtg.. Side Port Type Flange Mtg. : A37-F-R-01-*-S-K M10 Thd. 19 Deep (Both Sides) 3 Dia. Rear Side Suction Port 3 Dia. Fully Extended Surface of Suction Port Surface of For other dimensions, refer to Axial Port Type. Foot Mtg. Type:Mounting bracket is common to that of Axial Port Type. 45

Axial Port Type Flange Mtg. : A56-F-R-01-*-K Flow Adj. Screw 17 Hex. DEC. Pressure Adj. Screw 17 Hex. INC. Lock Nut 17 Hex. Fully Extended Filling Port 1 ( Hex. Head Plug Furnished) Drain Port (Bath Sides) Rc3/4 Thd. Surface of Drain Port Dia. Dia. Suction Port 35 Dia. M10 Thd. 19 Deep 8 Places 3 Dia. Dia. 1. Install the pump so that the Filling Port is at the top.. Use either port of the two drain ports at your option. Keep the remaining port plugged. Foot Mtg. : A56-L-R-01-*-K 14 Dia. Through 8 Dia. Spotface For other dimensions, refer to Flange Mtg.. Side Port Type Flange Mtg. : A56-F-R-01-*-S-K M10 Thd. 19 Deep (Both Sides) 3 Dia. Rear Side Suction Port 3 Dia. Fully Extended Surface of Suction Port Surface of For other dimensions, refer to Axial Port Type. 46

PISTON PUMPS Side Port Type Flange Mtg. : A70-FR01*S Fully Extended Drain Port (Both Sides) Rc3/4 Thd. Surface of Surface of Suction Port A Series Surface of Drain Port Surface of Drain Port 6 Dia. M10 Thd. 17 Deep Dia. Dia. 7 Dia. Spotface (Rear side) 35 Dia. Spotface Places (Rear side) Eye Bolt Filling Port 1 ( Hex. Head Plug Furnished) Flow Adj. Screw 17 Hex. DEC. Pressure Adj. Screw 17 Hex. INC. Suction Port 38 Dia. View Arrow Y Case Drain Port 3 5 Hex. Soc. M1 Thd. 19 Deep View Arrow X 1. Install the pump that the Filling Port is at the top.. Use either port of the two drain port at your option. Keep the remaining port plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mtg. : A70-LR01*S Dia. Through 43 Dia. Spotface For other dimensions, refer to Flange Mtg.. 47

Side Port Type Flange Mtg. : A90-FR01*S A100-FR01*S Drain Port (Both Sides) Rc3/4 Thd. Surface of Surface of Suction Port 3 Dia. M10 Thd. 19 Deep Fully Extended Dia. Dia. Surface of Drain Port 1.5 Dia. Through 39 Dia. Spotface (Rear Side) Surface of Drain Port Case Drain Port 3 5 Hex. Soc. Flow Adj. Screw 17 Hex. DEC. Pressure Adj. Screw 17 Hex. INC. Eye Bolt Filling Port 1 (7 Hex. Head Plug Furnished) Suction Port 48 Dia. View Arrow Y M1 Thd. 19 Deep View Arrow X 1. Install the pump that the Filling Port is at the top.. Use either port of the two drain port at your option. Keep the remaining port plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mtg. : A90-LR01*S A100-LR01*S Dia. Through 43 Dia. Spotface For other dimensions, refer to Flange Mtg.. 48

PISTON PUMPS Side Port Type Flange Mtg. : A145-FR01*S Flow Adj. Screw 17 Hex. DEC. 3 Dia. M10 Thd. 19 Deep Case Drain Port 3 5 Hex. Soc. Drain Port (Both Sides) Rc3/4 Thd. Dia. Dia. Filling Port 1 (7 Hex. Head Plug Furnished) Surface of Surface of Drain Port 1.5 Dia. Through 39 Dia. Spotface (Rear Side) Surface of Suction Port Surface of Drain Port Eye Bolt Pressure Adj. Screw 17 Hex. INC. A Series Suction Port 48 Dia. View Arrow Y View Arrow X M1 Thd. 19 Deep Foot Mtg. : A145-LR01*S 1. Install the pump that the Filling Port is at the top.. Use either port of the two drain port at your option. Keep the remaining port plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Dia. Through 43 Dia. Spotface For other dimensions, refer to Flange Mtg.. 49

Spare Parts List A10 ー F ー R ー 01 Item Name of Parts Part Numbers Qty. 5 Bearing 604 1 6 Oil Seal TCN4408Y 1 8 Bearing HMK115 1 30 O-Ring SO-NB-G50 1 31 O-Ring SO-NB-G10 1 3 O-Ring SO-NB-P14 1 33 O-Ring SO-NB-P1 5 34 O-Ring SO-NB-P6 35 O-Ring SO-NB-P9 1 54 O-Ring AS568-018 (NBR-70) 1 6 O-Ring SO-NB-P10 1 O-Ring of Item 35 shall be SO-NB-P1 in case of A10-FR01-B. Section X-X A16/A/A37/A56 ー * ー R ー 01 Section X-X Item Name of Parts Part Numbers A16-*-R-01 A-*-R-01 A37-*-R-01 A56-*-R-01 Qty. 16 Bearing 6305 6307 NUP 07E 1 17 Bearing HMK 1715 Z30-1303-PK410300-8 HMK 05V HMK 530V 1 35 Oil Seal TCN 54511 TCN 355511 TCN 355511 1 36 Gasket 130-PK11969-1 1316-PK11970-9 1307-PK1197-7 1 37 O-Ring SO-NA-G55 SO-NA-G75 1 40 O-Ring SO-NA-G5 SO-NA-G30 SO-NA-P36 41 O-Ring SO-NB-P1 SO-NB-P10A 1 4 O-Ring SO-NB-P9 1 43 O-Ring AS568-017 (NBR-70) 1 44 Seal Washer W8 1 6 O-Ring SO-NB-P14 1 50

PISTON PUMPS Spare Parts List A70/A90/A100-*R01*S A Series Section Z-Z Section X-X Section X-X (Only for "A70") Detail "A" Item Name of Parts A70-*R01*S Part Numbers A90-*R01*S A100-*R01*S 5 Gasket 1314E-PK1197-5 1310E-PK11973-3 1 Back Up Ring 1310E-PK41440-0 1310E-PK41440-0 1 38 Bearing NUP 08EX50 NUP 10E 1 39 Needle Bearing HMK 3030V HMK 3530BV 1 40 Oil Seal TCN 355511 (FKM) TCN 45681 (FKM) 1 4 O-Ring SO-FA-G85 SO-FA-G95 1 43 O-Ring SO-NA-P18 SO-NA-P18 1 44 O-Ring SO-NB-P9 SO-NB-P9 3 67 O-Ring SO-NB-P14 SO-NB-P18 1 68 O-Ring SO-NB-P5 SO-NB-P5 1 69 Seal Washer W10 1 Qty. 51

Spare Parts List A145-*R01*S Section X-X Item Name of Parts Part Numbers Qty. 6 Gasket 131-PK11974-1 1 15 Back Up Ring 1310E-PK41440-0 1 39 Bearing NUP 11ET 1 40 Needle Bearing 8Q-NK38 55 30 1 41 Oil Seal TCN 5071 (FKM) 1 43 O-Ring S-31.5 (NBR-70) 1 44 O-Ring SO-FA-G105 1 45 O-Ring SO-NA-P18 1 46 O-Ring SO-NB-P9 47 O-Ring AS568-017 (NBR-70) 1 48 O-Ring AS568-016 (NBR-70) 1 49 Back Up Ring For AS568-017 (NBR-70) 1 50 Back Up Ring For AS568-016 (NBR-70) 1 73 O-Ring SO-NB-P18 1 76 O-Ring SO-NB-P5 1 5

PISTON PUMPS, Solenoid Two Pressure Control Type Graphic Symbol Performance Characteristics A Series PL PH Output Flow SOL "OFF" SOL "ON" M O PL Pressure PH Specifications Model Numbers Geometric Displacement cm 3 /rev Minimum Adj. Flow cm 3 /rev Operating Pressure MPa Minimum Adj. Pres. Shaft Speed Range r/min Approx. Mass kg Rated Intermittent 1 MPa Max. Min. Flange Mtg. Foot Mtg. A16-*-R-0-*-K*-3 15.8 4 16 1 1. 1800 0 4.5 6.7 A-*-R-0-*-K*-3. 6 16 16 1. 1800 0 4.5 6.7 A37-*-R-0-*-K*-3 36.9 10 16 1 1. 1800 0 36 40.3 A56-*-R-0-*-K*-3 56. 1 16 1 1. 1800 0 43 47.3 A70-*R0S*- 70.0 36 5 5 1800 0 63.5 75.5 A90-*R0S*- 91.0 56 5 5 1800 0 80.5 101 A145-*R0S*- 145 83 5 5 1800 0 97.5 1.5 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details. Solenoid Ratings Electric source AC DC (K Series) AC DC Rectified(R) 1 Coil Type Frequency Voltage (V) Current & Power at Rated Voltage (Hz) Source Rating Serviceable Range Inrush (A) Holding (A) Power (W) 50 100 80-110.4 0.51 A100 100.14 0.37 90-10 110.35 0.44 50 96-13.0 0.4 A10 10 108-144 1.78 0.31 50 00 1-0 1.1 0.5 A00 00 1.07 0.19 180-40 0 1.18 0. A40 50 19-64 1.01 0.1 40 16-88 0.89 0.15 D1 1 10.8-13..45 D4 4 1.6-6.4 1.3 9 D48 48 43. - 5.8 0.61 R100 100 90-110 0.33 50/ R00 00 180-0 0.16 9 1. R type models with built-in current rectifier is recommended for shockless operation with AC power.. Inrush current in the above table show rms values at maximum stroke. Solenoid Two Pressure Control Type 53

Model Number Designation A16 -F -R -0 -S -K -A100-3 Series Number Mounting Direction of Rotation Control Type Port Position Shaft Extension Coil Type of Solenoid Valve Design Number A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) F: Flange Mtg. L: Foot Mtg. ( Viewed from Shaft End ) R: Clockwise 1 (Normal) 0: Solenoid Two Pressure Control Type None: Axial Port S: Side Port K: Keyed Shaft AC A100, A10 A00, A40 DC D1, D4 D48 R (AC DC Rectified) R100, R00 3 3 3 3 A70 -F R 0 S A100 - Series Number Mounting Direction of Rotation Control Type Port Position Coil Type of Solenoid Valve Design Number A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) F: Flange Mtg. L: Foot Mtg. ( Viewed from Shaft End ) R: Clockwise 1 (Normal) 0: Solenoid Two Pressure Control Type S: Side Port AC A100, A10 A00, A40 DC D1, D4 D48 R (AC DC Rectified) R100, R00 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details. Performance Characteristics For performance characteristics, refer to models of pressure compensator type on page 35 to 4. Pipe Flange Kits For Pipe flange, refer to form of pressure compensator type on page 3. 54 Solenoid Two Pressure Control Type

PISTON PUMPS Axial Port Type X Flange Mtg. : A16-F-R-0-K A-F-R-0-K 7.5 Lock Nut 14 Hex. 145 117 6 Lock Nut 17 Hex. Fully Extended 56.5 95 "PP1" "PP" 141.5 136 17 11 1 59 6.5 6.5 44.5 5 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc3/8 Thd. 19.05 19.0 Dia. 1.4 1.08 8.55 8.50 Dia. 96 1 Pilot Port "PP" Rc1/4 Thd. 95 Dia. 3 106 130 3 74.5 51.5 4.79 4.76 Electrical Conduit Connection G1/ Thd. (Both Ends) 18 R1 176 194.5 A Series Pressure Adj. Screw (PH) 14 Hex. Works at Solenoid Energised INC. 16 3 Pilot Port "PP1" Rc1/4 Thd. 188 3 Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised Flow Adj. Screw 5 Hex. Soc. DEC. 47.6 161 Suction Port 19 Dia.. 65 M10 Thd. 17 Deep 8 Places 19 Dia. View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 3. The pilot port "PP" is not provided for N.American Design Standard. Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 44 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. Solenoid Two Pressure Control Type 55

Side Port Type Flange Mtg. : A37-F-R-0-S-K Fully Extended 79.5 Lock Nut 17 Hex. 95 164.5 159 Pilot Port "PP" Rc1/4 Thd. 71.5 3 Lock Nut 14 Hex. "PP1" "PP" 135 77 9.5 30 59 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. 6 48.5 X 88.5 149 11 68 58.7 Front Side : 3 Dia. Rear Side : Suction Port 3 Dia. 30. 1 3.3.0 Dia. 5.01 4.85 101. 101.55 Dia. 105 14 10 Dia. 146 6.38 6.35 5 180 R14 198.5 M10 Thd. 19Deep 178.5 174 0 Pressure Adj. INC. Screw (PH) 14 Hex. Works at Solenoid Energised Flow Adj. Screw 5 Hex. Soc. 13 6 6 Pilot Port "PP1" Rc1/4 Thd. Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised DEC. 165 86 86 Surface of Suction Port View Arrow X Surface of 1. Install the pump so that the "Filling Port" is at the top.. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 3. The pilot port "PP" is not provided for N.American Design Standard. Axial Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 45 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 45 for the dimensions of mounting bracket. 56 Solenoid Two Pressure Control Type

PISTON PUMPS X Side Port Type Flange Mtg. : A56-F-R-0-S-K 31.5 174 146 Lock Nut 17 Hex. 90 Lock Nut 14 Hex. 77 Fully Extended 9 95 "PP1" "PP" 177 171.5 147.5 6 50.5 9.5 43.5 40 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc3/4 Thd. (Both Sides) 7.97 7.94 Pilot Port "PP" Rc1/4 Thd. 71.5 41 6 48.5 3 4 5 5 Electrical Conduit Connection G1/ Thd. (Both Ends) 49 58.7 05 A Series 5 3.5 14 Front Side : 3 Dia. Rear Side : Suction Port 35 Dia. M10 Thd. 19 Deep 30. 1 07 31.75 Dia. 31.70 35.3 35.14 101. 101.55 Dia. 10 Dia. 146 174 3 R14 Pressure Adj. Screw (PH) INC. 14 Hex. Works at Solenoid Energised Flow Adj. Screw 5 Hex. Soc. 13 6 6 Pilot Port "PP1" Rc1/4 Thd. Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised 3 DEC. 190 Surface of Suction Port 100 100 Surface of View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 4. The pilot port "PP" is not provided for N.American Design Standard. 5. Dimensions show surface of drain port. Axial Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 46 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 46 for the dimensions of mounting bracket. Solenoid Two Pressure Control Type 57

Flange Mtg. : A70-FR0* Fully Extended 354.5 39 95 33.5 09.5 65 6 9.5 Drain Port Rc3/4 Thd. (Both Sides) Surface of Surface of Drain Port 7 Dia. Spotface (Rear Side) 95 95 73 73 10 3 4 Pilot Port "PP" Rc1/4 Thd. Surface of Suction Port Surface of Drain Port Electrical Conduit Connection G1/ Thd. (Both Ends) X 5.4 6 Dia. M10 Thd. 17 Deep 19.5 6. 16 18 46.5 40 31.75 31.70 Dia. 35.3 35.14 17.00 16.95 Dia. 90 0.5 186.5 18 14 35 Dia. Spotface (Rear Side) Places 114.4 134 181 11 7.97 7.94 114.4 180 17.5 118 36 Y INC. Pressure Adj. Screw (PH) 14 Hex. Works at Solenoid 64.5 Energised 87.5 10 View Arrow X Pilot port "PP1" Rc1/4 Thd. 3 Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised Flow Adj. Screw 17 Hex. DEC. Eye Bolt 1 M10 Filling Port ( Hex. Head Plug Furnished) 5 Case Drain Port 5 Hex. Soc. 35.7 46.5 View Arrow Y 69.9 Suction Port 38 Dia. M1 Thd. 19 Deep 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 4. The pilot port "PP" is not provided for N.American Design Standard. 5. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 47 for the dimensions of mounting bracket. 58 Solenoid Two Pressure Control Type

PISTON PUMPS Flange Mtg. : A90-FR0* 63.5 95 Drain Port Rc3/4 Thd. (Both Sides) Surface of Surface of Drain Port 105 105 68 68 Surface of Suction Port Surface of Drain Port A Series 119.5 3 13 Pilot Port "PP" Rc1/4 Thd. 3 4.5 5 9.56 9.53 X 58.7 3 Dia. M10 Thd. 19 Deep 30. 70 63 3 38.10 38.05 Dia. 4.36 4.18 15.40 15.35 Dia. 113 1 196 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 161.6 161.6 17 6 R 45.5 Y Case drain Port 5 Hex. Soc. 5 Pressure Adj. Screw (PH) 14 Hex..5 Works at Solenoid INC. Energised.5 Pilot Port "PP1" Rc1/4 Thd. Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised Flow Adj. Screw 17 Hex. DEC. View Arrow X 3 1 Eye Bolt M10 Filling Port (7 Hex. Head Plug Furnished) Fully Extended 379 58 95 4.9 70 View Arrow Y 77.8 Electrical Conduit Connection G1/ Thd. (Both Ends) 88 168 Suction Port 48 Dia. 196 M1 Thd. 19 Deep 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 4. The pilot port "PP" is not provided for N.American Design Standard. 5. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 48 for the dimensions of mounting bracket. Solenoid Two Pressure Control Type 59

Flange Mtg. : A145-FR0* Fully Extended 400.5 11 Surface of 11 11 Surface of Suction Port X 58.7 3 Dia. M10 Thd. 19 Deep 30. Case Drain Port 5 Hex. Soc. 5 85 55.5 99.5 89 4 3 13 6 70 Drain Port Rc3/4 Thd. (Both Sides) 44.45 44.40 Dia. 49.39 49.1 15.40 Dia. 15.35 110 Surface of Drain Port Pilot Port "PP" Rc1/4 Thd. 14 3 4 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 7 7 1 8.6 73 Surface of Drain Port 8.6 R 198 11.14 11.11 47.5 141 Y Eye Bolt M10 79 95 Electrical Conduit Connection G1/ Thd. (Both Ends) Pressure Adj. Screw (PH) 14 Hex. Works at Solenoid INC. Energised 9 66.5 Pilot Port "PP1" Rc1/4 Thd. 1 3 Pressure Adj. Screw (PL) 14 Hex. Works at Solenoid INC. De-energised Flow Adj. Screw 17 Hex. DEC. 1 Filling Port (7 Hex. Head Plug Furnished) Suction Port 48 Dia. 77.8 M1 Thd. 19 Deep 4.9 View Arrow X 99.5 View Arrow Y 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. The pilot port provided is for connecting a control valve, if multistage pressure control is required. 4. The pilot port "PP" is not provided for N.American Design Standard. 5. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 49 for the dimensions of mounting bracket. Solenoid Two Pressure Control Type

PISTON PUMPS, Pressure Compensator with Unloading Type Graphic Symbol Performance Characteristics A Series M O Output Flow SOL "OFF" SOL "ON" Pressure Specifications Model Numbers Geometric Displacement cm 3 /rev Minimum Adj. Flow cm 3 /rev Operating Pressure Shaft Speed Range Unloading Pressure MPa r/min MPa Rated Intermittent Max. Min. A16-*-R-03-*-K-*-3 15.8 4 16 1 1. 1800 0 A-*-R-03-*-K-*-3. 6 16 16 1. 1800 0 A37-*-R-03-*-K-*-3 36.9 10 16 1 1. 1800 0 A56-*-R-03-*-K-*-3 56. 1 16 1 1. 1800 0 A70-*R03S*- 70.0 36 5 5 1. 1800 0 A90-*R03S*- 91.0 56 5 5 1. 1800 0 A145-*R03S*- 145 83 5 5 1. 1800 0 Model Number Designation A16 -F -R -03 -S -K -A100-3 Series Number A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise 1 (Normal) Control Type 03: Pressure Compensator with Unloading Type Port Position None: Axial Port S: Side Port Shaft Extension K: Keyed Shaft Coil Type of Solenoid Valve AC A100, A10 A00, A40 DC D1, D4 D48 R (AC DC Rectified) R100, R00 Design Number 3 3 3 3 A70 -F R 03 S A100 - Series Number A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise 1 (Normal) Control Type 03: Pressure Compensator with Unloading Type 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. Please inquire for A0 separatery. Port Position S: Side Port Coil Type of Solenoid Valve AC A100, A10 A00, A40 DC D1, D4 D48 R (AC DC Rectified) R100, R00 Design Number Consult Yuken when detailed material such as dimensions figures is required. Pressure Conpensator with Unloading Type 61

, Proportional Electro-Hydraulic Load Sensing Type Performance Characteristics Graphic Symbol 1 (Small Input Current i Large) Output Flow (Small Pressure Input Current i 1 Large) 1 M O A16/A/A37/A56 M O A70/A90/A145 Model Number Designation A56 -F -R -04 -C -K -3 Series Number A16 (15.8 cm 3 /rev) Mounting Direction of Rotation ( Viewed from Shaft End ) Control Type Pressure Adj. Range MPa Shaft Extension B: 1.5-6.9 (0-1000) C: 1.5-15.7 (0-80) H: 1.5-0.6 (0-990) A 04: B: 1.5-6.9 (0-1000) (. cm 3 /rev) F: Flange Mtg. Proportional C: 1.5-15.7 (0-80) Electro-Hydraulic A37 L: Foot Mtg. Load Sensing R: Clockwise 1 (36.9 cm 3 /rev) Type B: - 6.9 (90-1000) A56 (56. cm 3 /rev) C: - 15.7 (90-80) H: - 0.6 (90-990) K: Keyed Shaft Design Number 3 3 3 3 A70 -F R 04 C S - Series Number Mounting Direction of Rotation Control Type Pressure Adj. Range MPa Port Position Design Number A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) F: Flange Mtg. L: Foot Mtg. ( Viewed from Shaft End ) R: Clockwise 1 04: Proportional Electro-Hydraulic Load Sensing Type C: 1.5-16 (0-30) H: 1.5-1 (0-3050) S: Side Port 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. Please inquire for A0 separatery. 6 Proportional Electro-Hydraulic Load Sensing Type

PISTON PUMPS Pipe Flange Kits Pipe flange kits are available. When ordering, specify the kit number from the table below. Pump Model Numbers A16-*-R-04 A-*-R-04 A37-*-R-04 A56-*-R-04 Pipe Flange Kit Numbers Name of Port Threaded Connection Socket Welding 1 Butt Welding Suction F5-06-A-10 F5-06-B-10 F5-06-C-10 Discharge Suction F5-10-A-10 F5-10-B-10 F5-10-C-10 Discharge F5-06-A-10 F5-06-B-10 F5-06-C-10 A Series A 70-*R04 A 90-*R04 A145-*R04 Suction F5-1-A-10 F5-1-B-10 F5-1-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 Suction F5-16-A-10 F5-16-B-10 F5-16-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the flanges. Therefore, please pay cautious attension to the operating pressure when the socket welding flanges are used.. Discharge port for pump model "A16" and "A" is available only the threaded connections. Details of the pipe flange kits are shown on page 6. Instructions Bleeding Air In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature with operating oil. Manual Adjustment Screws Manual adjustment screws may be used for initial running adjustment or in case of electrical failures in order to adjust pressure and flow temporarily. In case of normal use, put the manual adjustment screws back in their preset positions. Position of Cable Departure Position of cable departure can be changed. For details, refer to drawing below. Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type) If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as pilot piping (refer to symbol below). Inside diameter of pipe should be more than 8 mm. Consult Yuken of detail of surge cut-off valve. Connector (The direction can be altered to every 90 degree angles.) Surge Cut-off Valve (SF1105-A-10) i1 "PP" i M O Proportional Electro-Hydraulic Load Sensing Type 63

Specifications Descriptions Model Numbers A16 A A37 A56 A70 A90 A145 Geometric Displacement cm 3 /rev 15.8. 36.9 56. 70.0 91.0 145 Operating Pressure MPa Shaft Speed Range r/min Flow Control Pres. Control Rated 16 16 16 16 1 1 1 Intermittent 1 1 16 1 1 1 1 1 Max. 1800 1800 1800 1800 1800 1800 1800 Min. 0 0 0 0 0 0 0 Flow Adj. Range L/min 1-8.4 1-40 1-66 1-101 1-16 1-163 - 61 Min. Pres. Required for Flow Adj. MPa 1.5 1.5 1.5.0 1.0 1.0 1.0 Differential Pres. (Discharge Pres. -Load Pres.) MPa 0.37 0. Step Response 5 (0 Max. Flow) ms 70 80 10 15 100 10 10 Hysteresis 3 % or less 1 Rated Current ma 900 700 740 790 80 90 90 Coil Resistance (0 C) 10 Pres. Adj. Range MPa Refer to Model Number Designation Step Response ms 5 t 1 80 80 50 55 150 150 1 t 5 140 90 80 80 80 10 180 Hysteresis Rated Current ma (Pres. Adj. Range) B: 770, C:880, H:790 % or less 1 C: 8 H: 765 C: 873 H: 765 C: 875 H: 755 Coil Resistance (0 C) Ω 10 Applicable Amplifier Model 3 AME-D-1010-11 Approx. Mass kg Flange Mtg. 3 3 38 45 7.5 88.5 109.5 Foot Mtg. 34. 34. 43. 49.3 84.5 109 134.5 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details. 3. Specifications of power amplifiers, consult Yuken for details. 4. The figure mentioned in the above table are those obtained using Yuken's amplifier. 5. Step response depends on circuit and operating conditions. Data shown in the table above is an example based on the condition right. Model Pres. Step Response t1 A16, A 1.5 16 MPa 16 1.5 MPa A37, A56.0 16 MPa 16.0 MPa A70, A90 A145 3.0 16 MPa 16 3.0 MPa t Loading Volume High Pressure Hose 3/8" m High Pressure Hose 3/4" m High Pressure Hose 1-1/4" m 64 Proportional Electro-Hydraulic Load Sensing Type

PISTON PUMPS Typical Performance Characteristics at Viscosity 0 mm /s [ISO VG3 Oils, 50 C] Full Cut-off Pres. vs. Input Signal Full Cut-off Pressure MPa 1 0 16 1 8 4 0 "H" "B" "C" 00 400 0 800 900 Input Current ma Full Cut-off Pressure MPa 4 0 16 "H" 1 "C" 8 4 0 00 400 0 800 Input Current ma 1000 A Series Note: Pressure adjustment range "H" is not available for A. Output Flow vs. Input Current Output Flow L/min N=1800 r/min 3 4 16 8 0 00 400 0 800 1000 Input Current ma N=1800 r/min 70 Output Flow L/min Output Flow 40 30 0 10 0 L/min 110 100 80 40 0 N=1800 r/min 00 400 0 800 Input Current ma N=1800 r/min 0 00 400 0 800 900 Output Flow L/min 50 40 30 0 10 0 00 400 0 800 Input Current ma Output Flow L/min 140 10 80 40 0 Input Current ma N=1800 r/min 00 400 0 800 1000 Input Current ma Output Flow L/min 00 1 10 80 40 0 00 400 0 800 N=1800 r/min 1000 Output Flow L/min 80 40 00 1 10 80 N=1800 r/min Input Current ma 40 0 00 400 0 800 Input Current ma 1000 Proportional Electro-Hydraulic Load Sensing Type 65

Flange Mtg. : A16-F-R-04*-K A-F-R-04*-K 9 44.5 Cable Departure (For Pres. Control) 13 6.5 167.5 Filling Port ( Hex. Head Plug Furnished) 101.5 6.5 59 Drain Port Rc3/8 Thd. 63. 5 X 55.5 177.5 15.5 4.79 4.76 18 57.5 96 1 Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd 17 1 Surface of Suction Port 187 6 19.05 Dia. 19.0 1.4 1.08 8.55 8.50 Dia. 95 Dia. 106 130 188 R1 Surface of Tank Port Air Vent Rc1/4 Thd. 3 Hex. Soc. Manual Pressure Adj. Screw 3 Hex. Soc. INC. Safety Valve Pressure Adj. Screw 17 Hex. INC. 48 47.6 Suction Port 19 Dia. 41 70 15. Pilot Port "PP" Rc1/4 Thd. Cable Departure (For Flow Control) 57.5 Manual Pressure Adj. Screw 3 Hex. Soc. INC. 103 Air Vent 3 Hex. 3 Places. M10 Thd. 17 Deep. 56 3.5 85 See 3 94 190.5 G3/8 Thd. View Arrow X 1. Detail of 14 1.5. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm 3. Do not touch the screw because it is adjusted at the time of shipment. G 3/8 Thd. 8 Dia. 18.6 Dia. 15 Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. 66 Proportional Electro-Hydraulic Load Sensing Type

PISTON PUMPS Flange Mtg. : A37-F-R-04*-K X Air Vent 3 Hex. Soc. 3 Places. Manual Flow Adj. Screw 3 Hex. Soc. INC. 75.5 185.5 147. Manual Pressure Adj. Screw 3 Hex. Soc. Air Vent 3 Hex. Soc. 3 Places 308.5 59 Cable Departure 1 96.5 9.5 (For Pres. Control) 110.5 77 30 3 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. 105 INC. 77.3 Safety Valve Pressure Adj. Screw 3 Hex. Soc. INC. 6.38 6.35 13 A Series 7 195 1 Surface of Suction Port 8 8 Surface of 100.5 115.5 Pilot Port "PP" Rc1/4 Thd. 7 Cable Departure (For Flow Control) 1 58.7 85 47.6 14 Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd..3.0 Dia. 5.01 4.85 101. Dia. 101.55 10 Dia. 146 174 0 5 R14 Suction Port 3 Dia. M10 Thd. 19 Deep 1. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm 30.. 36 4 83 View Arrow X 0 Dia. M10 Thd. 19 Deep Foot Mtg. : A37-L-R-04*-K 14 Dia. Through 8 Dia. Spotface 3 14 15 10 74 115 39 10 95 95 30 For other dimensions, refer to Flange Mtg.. Proportional Electro-Hydraulic Load Sensing Type 67

Flange Mtg. : A56-F-R-04*-K X Air Vent 3 Hex. Soc. 3 Places. Manual Flow Adj. Screw 3 Hex. Soc. INC. 83.5 185.5 147. 7 30.5 6 308.5 9.5 1.5 50.5 43.5 40 Manual Pressure Adj. Screw 3 Hex. Soc. Air Vent 3 Hex. Soc. 3 Places 1 Cable Departure (For Pres. Control) Filling Port ( Hex. Head Plug Furnished) Drain Port (Both Sides) Rc3/4 Thd. 90 INC. 77.8 41 49 Surface of Drain Port 7.97 7.94 Safety Valve Pressure Adj. Screw 3 Hex. Soc. INC. 14 5 Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 07 1 31.75 31.70 Dia. 35.3 35.14 101. 101.55 Dia. 10 Dia. 146 174 R14 Surface of Suction Port 40 3 94 Surface of Pilot Port "PP" Rc1/4 Thd. 100 116 7 Cable Departure 1 (For Flow Control) 94 58.7 47.6 1. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm. Use either port of two drain ports at your option. Keep the remaining port plugged. Suction Port 35 Dia. M10 Thd. 19 Deep 30.. 38 44 85 View Arrow X 0 Dia. M10 Thd. 19 Deep Foot Mtg. : A56-L-R-04*-K 14 Dia. Through 8 Dia. Spotface 3 14 15 10 77 115 4 10 95 95 30 For other dimensions, refer to Flange Mtg.. 68 Proportional Electro-Hydraulic Load Sensing Type

PISTON PUMPS Flange Mtg. : A70-FR04*S Manual Pressure Adj. Screw 3 Hex. Soc. Air Vent 3 Hex. Soc. 3 Places Manual Flow Adj. Screw 3 Hex. Soc. INC. Air Vent 3 Hex. Soc. 3 Places 3 Cable Departure (For Flow Control) Tank Port Rc3/8 Thd. 83 30. INC. Primary Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. M10 Thd. 17 Deep 5 Dia. 344.5 Cable Departure 3 (For Pres. Control) 7.5 196.5 191.5 137 19.5 65 9.5 40 16 58.7 18 76 15 Drain Port (Both Sides) Rc3/4 Thd. 6 31.75 31.70 Dia. 35.3 35.14 Dia. 17.00 16.95 1 90 Pilot Port Rc1/4 Thd. Secondary Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 137 10 50 35 Dia. Spotface (Rear Side) Places 7 Dia. Spotface (Rear Side) 196.5 169 140 95 104.3 73 73 114.4 134 181 11 Surface of Drain Port 7.97 7.94 14 14 Safety Valve INC. Pressure Adj. Screw 3 Hex. Soc. Surface of Suction Port 18 114.4 180 118 196.5 X A Series Filling Port ( Hex. Head plug Furnished) Eye Bolt M10 Suction Port 38 Dia. 69.9 M1 Thd. 19 Deep 1. Use either port of two drain ports at your option. Keep the remaining port plugged.. Case drain port is available for use when draining hydraulic fluid from pump casing. 3. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm Case Drain Port 5 Hex. Soc. 46.5 View Arrow X 35.7 Foot Mtg. : A70-LR04*S 4.5 130 17 Dia. 3 Dia. Through 43 Dia. Spotface 4 15 77 6 171 195 37 130 130 30 For other dimensions, refer to Flange Mtg.. Proportional Electro-Hydraulic Load Sensing Type 69

Flange Mtg. : A90-FR04*S Manual Pressure Adj. Screw 3 Hex. Soc. Air Vent 3 Hex. Soc. 3 Places Manual Flow Adj. Screw 3 Hex. Soc. Air Vent 3 Hex. Soc. 3 Places 83 INC. Cable Departure (For Flow Control) 3 30. INC. Tank Port Rc3/8 Thd. Primary Pressure Gauge Connection for Pump Discharge Pres. Rc1/4 Thd. M10 Thd. 17 Deep 5 Dia. 58.7 370.5 51 0 15 38.5 99.5 Cable Departure (For Pres. Control) 1.5 119.5 3 95 3 13 63 3 Drain Port (Both Sides) Rc3/4 Thd. 38.10 38.05 Dia. 4.36 4.18 Case Drain Port 5 Hex. Soc. 15.40 15.35 Dia. 1 Pilot Port Rc1/4 Thd. Secondary Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 113 137 10 50 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 06.5 179 150 104.3 68 68 161.6 105 Filling Port (7 Hex. Head Plug Furnished) Eye Bolt M10 Surface of Drain Port Safety Valve Pressure Adj. Screw 3 Hex. Soc. INC. Surface of Suction Port 17 06 R 161.6 9.56 9.53 Suction Port 48 Dia. X 77.8 1. Use either port of two drain ports at your option. Keep the remaining port plugged.. Case drain port is available for use when draining hydraulic fluid from pump casing. 3. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm 70 4.9 View Arrow X M1 Thd. 19 Deep Foot Mtg. : A90-LR04*S Dia. Through 43 Dia. Spotface 140 3 4 5 15 110 15 00 70 157.5 157.5 375 For other dimensions, refer to Flange Mtg.. 70 Proportional Electro-Hydraulic Load Sensing Type

PISTON PUMPS Flange Mtg. : A145-FR04*S Manual Pressure Adj. Screw 3 Hex. Soc. 83 30. INC. Air Vent 3 Hex. Soc. 3 Places Cable Departure (For Flow Control) Tank Port Rc3/8 Thd. Primary Pressure Gauge Connection for Pump Discharge Pres. Rc1/4 Thd. M10 Thd. 17 Deep 5 Dia. 3 58.7 Cable Departure (For Pres. Control) 400 Drain Port (Both Sides) Rc3/4 Thd. 80.5 11 49.5 64 5 168 4 6 89 3 13 3 70 44.45 44.40 Dia. 49.39 49.1 15.40 Dia. 15.35 1 Manual Flow Adj. Screw 3 Hex. Soc. INC. Pilot Port Rc1/4 Thd. Secondary Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 110 137 Air Vent 3 Hex. Soc. 3 Places 10 50 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 16.5 189 1 11 7 85.3 8.6 73 7 Surface of Drain Port Surface of Suction Port Safety Valve Pressure Adj. Screw 3 Hex. Soc. INC. 11.14 11.11 R A Series Filling Port (7 Hex. Head Plug Furnished) Eye Bolt M10 Suction Port 48 Dia. 77.8 141 08 8.6 X 33 Case Drain Port 5 Hex. Soc. 1. Use either port of two drain ports at your option. Keep the remaining port plugged.. Case drain port is available for use when draining hydraulic fluid from pump casing. 3. Cable Applicable: Outside Dia...8-10 mm Conductor Area...Not Exceeding 1.5 mm 99.5 View Arrow X M1 Thd. 19 Deep 4.9 Foot Mtg. : A145-LR04*S Dia. Through 43 Dia. Spotface 187.3 3 114.3 119 80 9 30 185 80 187.3 187.3 438 For other dimensions, refer to Flange Mtg.. Proportional Electro-Hydraulic Load Sensing Type 71

, Electro-Hydraulic Proportional Pressure & Flow Control Type Input Signal for Flow Control Input Signal for Pressure Control Amplifier Proportional Solenoid Pressure Sensor Control Valve Control Piston Performance Characteristics (S Input Voltage L) Output Flow Pressure (S Input Voltage L) 1. Unloading pressure when input signal is 0 V.. Safety valve setting pressure Safety valve Tilt Angle Sensor Bias Piston Model Number Designation A45 -F R 04E 16M S - -10 A70 -F R 04E 16M A - - Series Number A45 (45.0 cm 3 /rev) A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A100 (100 cm 3 /rev) A145 (145 cm 3 /rev) Mounting L: Foot Mtg. F: Flange Mtg. Direction of Rotation Viewed (from End Shaft) R: Clockwise 1 (Normal) Control Type 04E: Proportional Pressure & Flow Control Type Control Pressure at Input Signal is 5 V Use the same measure of the control pressure as shown on the right, 6.9 MPa specify within the range of maximum operating pressure Type of Outboard Pump Port Position 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. These pumps, except A16/A/A45 types, can be connected to outboard pumps. - A37/A56 type (outboard pump connection symbol: None): spigot diameter: 8.55 mm (A16, A, and PVR1). - A70/A90/A100/A145 type (outboard pump connection symbol: "A"): spigot diameter:8.55 mm (A16, A, and PVR1). - A70/A90/A100/A145 type (outboard pump connection symbol: "B"): spigot diameter:101.6 mm (A37 and PVR). 3. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail. None : Axial Port S : Side Port Compensation Number 3 Design Number 10 06 4 11 4 None 4 A B 4 10 7 Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Specifications Descriptions Model Numbers A16 A A37 A45 A56 A70 A90 A100 A145 Geometric Displacement cm 3 /rev 15.8. 36.9 45.0 56. 70.0 91.0 100 145 Operating Pressure MPa Rated 16 16 16 16 16 5 5 1 5 Intermittent 1 1 16 1 17. 1 8 8 1 8 Shaft Speed Range r/min 0-1800 Flow Control Pressure Control Max. Flow 3 L/min 50 Hz Pin 8.4 40.0 66.4 81.0 101 16 163 180 61 Hz Pin 3.7 33.3 55.4 67.0 84.3 105 136 150 17 Min. Pres. Required for Flow Adj. MPa Hysteresis Repeatability Input Signal 1 % or less 1 % or less Max. Flow / 5 V DC Min. Adjustment Pressure MPa 0.7 Hysteresis Repeatability Input Signal 1 % or less 1 % or less Specified Control Pressure / 5 V DC Coil Resistance Ω(@0 ) 10 Input Impedance Flow Control : 10 kω Pressure Control : 10 kω Supply Electric Power 4 V DC (1-8 V Included Ripple) Power Input (Max.) W 30 Output Signal Flow Pressure 5 V DC / Max. Flow (50 Hz Pin) 5 V DC / Specified Control Pressure Alarm Signal Output (Open Collector) Voltage : Max. 30 V DC Current : Max. 40 ma Ambient Temperature 0-50 (With Circulated Air) Approx. Mass kg Flange Mtg. 0.5 0.5 3 3 39 64 76.5 76.5 96.4 Foot Mtg..7.7 36.3 36.3 43.3 76 97 97 11.4 A Series 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details. 3. Maximum flow differs to shaft speed. The value listed above indicates shaft speed of 1800 r/min. For other shaft speed calculate by the ratio of shaft speed. Pipe Flange Kits Pipe flange kits are available. When ordering, specify the kit number from the table below. Pump Model Numbers Name of Port Pipe Flange Kit Numbers Threaded Connection Socket Welding Butt Welding A 16-*R04E A -*R04E A 37-*R04E A 45-*R04E A 56-*R04E A 70-*R04E Suction F5-06-A-10 F5-06-B-10 F5-06-C-10 Discharge F5-06-A-10 F5-06-B-10 F5-06-C-10 Suction F5-10-A-10 F5-10-B-10 F5-10-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 Suction F5-1-A-10 F5-1-B-10 F5-1-C-10 Discharge F5-08-A-10 F5-08-B-10 F5-08-C-10 A 90-*R04E Suction F5-16-A-10 F5-16-B-10 F5-16-C-10 A100-*R04E A145-*R04E Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used. Details of the pipe flange kits are shown on page 6. Electro-Hydraulic Proportional Pressure & Flow Control Type 73

Outboard Pumps A37 to A145 type pumps, except A16/A/A45, can be used as double pumps, by connecting an outboard pump on the cover side. See the table below for details. Connectable Outboard Pump Outboard Pump Connection Symbol A37/A56 A70/A90/ A100/A145 Connectable pumps shafts are involute-serrated design, not the standard parallel key slot design. For details, including pump dimensions and model numbers, consult Yuken. Coupling Please use assembly part number when ordering coupling assemblies for shaft connections to outboard pumps. Dia. Outboard Pump Connection Symbol Spigot Diameter for Connecting an Outboard Pump mm mm Selecting an Outboard Pump Type The maximum torque of outboard pumps is limited by shaft and coupling assembly strength. When determining the outboard pump type, the value of the displacement times the pressure for a particular pump should not exceed the value shown in the table below. q1, q : Displacement cm 3 /rev P1, P : Pressure MPa For selection of the appropriate pump, both values, 1 and, should be satisfied. Dia. Involute-serration Connectable Pump None A 8.55 A16, A, PVR1 A 101.6 A37, PVR Part Number of Coupling Ass'y Dimensions mm "D 1 " "D " ( Serration Size Nominal Dia. No. of Teeth ) Mojule A37/A56 None 098-PK41588-6 7 19.5 18.75 4 0.75 A70/A90/ A A100/A145 B 098-PK4163-1 36 6 5 4 1 Pump Model No. 1Inboard Pump and Outboard Pump (q 1 P 1 )+(q P ) Outboard Pump q P Outboard pump connection symbol "None"/"A" "B" A37 900 and less A56 174 and less A70 408 and less 519 and less 935 and less A90/A100 4348 and less 977 and less A145 4739 and less 951 and less Attachment Amplifier Pump Model Numbers Amplifier Model Numbers Control Pressure MPa SK1106- -16-06-10-14.7 A16-*R04E -06-4 SK1106- -16-06-1001 14.8-19.6 SK1106- -16-06-100 19.7-1.0 A-*R04E -11-4 SK1106- --11-10 - 14.7 SK1106- --11-1001 14.8-16.0 SK1106- -37--10-14.7 A37-*R04E --4 SK1106- -37--1001 14.8-19.6 SK1106- -37--100 19.7-1.0 SK1106- -45--10-14.7 A45-*R04E *--10 SK1106- -45--1001 14.8-17. SK1106- -56--10-14.7 A56-*R04E --4 SK1106- -56--1001 14.8-19.6 SK1106- -56--100 19.7-1.0 SK1106- -70--10-14.7 A70-*R04E *-- SK1106- -70--1001 14.8-19.6 SK1106- -70--100 19.7 -.6 SK1106- -70--1003.7 - SK1106- -91--10-14.7 A90-*R04E *-- SK1106- -91--1001 14.8-19.6 SK1106- -91--100 19.7 -.6 SK1106- -91--1003.7 - SK1106- -100--10-14.7 A100-*R04E --10 SK1106- -100--1001 14.8-19.6 SK1106- -100--100 19.7-1.0 SK1106- -145--10-14.7 SK1106- -145--1001 14.8-19.6 A145-*R04E *-- SK1106- -145--100 19.7 -.6 SK1106- -145--1003.7 - Note 1. The symbol " ", shown with pump and amplifier model numbers, is the control pressure at input signal of 5 V.. Cable for pump-amplifier connection is not included. See Page 81 for details on ordering cables. Instructions Input Signal The pump is on unload condition when the pump is operated without input signal voltage. Electric Source Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed. Compensation of Pump Maximum Regulated Flow at Frequency If the same maximum flow is required at 50 Hz or Hz, connect short plug in the amplifier to Hz at the place where supplied frequency is Hz. At this condition, maximum flow comes to the same value at 50 Hz. If short plug is used at Hz without making the change, maximum flow increased in proportion to frequency. 74 Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Output Flow vs. Input Signal Output Flow Output Flow A Series Output Flow Input Signal Output Flow Input Signal Output Flow Input Signal Output Flow Input Signal Output Flow Input Signal Output Flow Input Signal Input Signal Note: Pump characteristics at 1800 r/min is the same as those at 1500 r/min where frequency is compensated. (Refer to page 74.) Full Cut-off Pres. vs. Input Signal Full Cut-off Pressure Specified Pressure Input Signal Output Flow Input Signal Input Signal Refer to page 35 to 4 for performance characteristics of pressure compensator type excluding characteristics appeared on this catalogue. As for A45, contact us for details. Electro-Hydraulic Proportional Pressure & Flow Control Type 75

Flange Mtg. : A16-FR04E* A-FR04E* Cable Departure Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm Pressure Sensor Connector Air Vent 3 Hex. Soc. Filling Port 1 ( Hex. Head Plug Furnished) Drain Port Rc3/8 Thd. Tilt Angle Sensor Connector Suction Port 19 Dia. M10 Thd. 17 Deep 8 Places 19 Dia. Dia. Dia. Dia. 1. Install the pump so that the Filling Port is at the top.. Do not touch the screw because it is adjusted at the time of shipment. 3. For cable connection with amplifiers, see page 81. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. Flange Mtg. : A37-FR04E* Cable Departure 3 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm End Cover Seal Cover Plain Washer Hex. Hd. Screw 3 Dia. M10 Thd. 19 Deep Outboard Pump Position Air Vent 3 Hex. Soc. Drain Port Rc1/ Thd. Dia. Dia. Tilt Angle Sensor Connector Filling Port 1 ( Hex. Head Plug Furnished) Dia. Pressure Sensor Connector Suction Port 3 Dia. M10 Thd. 19 Deep 1. Install the pump so that the Filling Port is at the top.. Do not touch the screw because it is adjusted at the time of shipment. 3. For cable connection with amplifiers, see page 81. View Arrow X Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 45 for the dimensions of mounting bracket. 76 Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Axial Port Type Flange Mtg. : A45-FR04E* Cable Departure 3 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm Pressure Sensor Connector Air Vent 3 Hex. Soc. Filling Port 1 ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. A Series Suction Port 3 Dia. 3 Dia. M10 Thd. 19 Deep 8 Places Dia. Dia. Dia. Tilt Angle Sensor Connector View Arrow X Side Port Type 1. Install the pump so that the Filling Port is at the top.. Do not touch the screw because it is adjusted at the time of shipment. 3. For cable connection with amplifiers, see page 81. Flange Mtg. : A45-FR04E*S M10 Thd. 19 Deep (Both Sides) Suction Port 3 Dia. Rear Side 3 Dia. Surface of Surface of Suction Port For other dimensions, refer to Axial Port Type. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 46 for the dimensions of mounting bracket. Electro-Hydraulic Proportional Pressure & Flow Control Type 77

Flange Mtg. : A56-FR04E* Cable Departure 4 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm End Cover Seal Cover Plain Washer Hex. Hd. Screw 3 Dia. M10 Thd. 19 Deep Outboard Pump Position 3 Air Vent 3 Hex. Soc. Drain Port Rc3/4 Thd. Places Dia. Dia. Tilt Angle Sensor Connector Filling Port 1 ( Hex. Head Plug Furnished) DR (with Plug) DR Dia. Pressure Sensor Connector Suction Port 35 Dia. M10 Thd. 19 Deep 3 View Arrow X 1. Install the pump so that the Filling Port is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For cable connection with amplifiers, see page 81. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 46 for the dimensions of mounting bracket. Flange Mtg. : A70-FR04E* Cable Departure 4 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm End Cover Seal Cover Plain Washer Hex. Hd. Screw 6 Dia. Thd. Deep Places Outboard Pump Position 5 Air Vent Hex. Soc. Drain Port Rc Thd. Places Dia. Dia. Dia. Spotface (Rear Side) Places Filling Port 1 ( Hex. Head Plug Furnished) P DR DR (with Plug) Case Drain Port 3 5 Hex. Soc. Eye Bolt Tilt Angle Sensor Connector Pressure Sensor Connector Suction Port 38 Dia. M1 Thd. 19 Deep 3 3 1. Install the pump so that the Filling Port is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. View Arrow X 4. For cable connection with amplifiers, see page 81. 5. If you do not use the special sequence valve, plug the port (FP-SC-1/3). Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 47 for the dimensions of mounting bracket. 78 Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Flange Mtg. : A90-FR04E** A100-FR04E** Cable Departure 4 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm End Cover Seal Cover Plain Washer Hex. Hd. Screw 3 Dia. M10 Thd. 19 Deep Outboard Pump Position 5 Air Vent 3 Hex. Soc. Drain Port Rc Thd. Places Surface of Drain Port 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 3 Case Drain Port 3 5 Hex. Soc. 3 View Arrow X Dia. Dia. Surface of Drain Port (with Plug) Filling Port 1 (7 Hex. Head Plug Furnished) Eye Bolt Tilt Angle Sensor Connector Pressure Sensor Connector Suction Port 48 Dia. M1 Thd. 19 Deep 1. Install the pump so that the Filling Port is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For cable connection with amplifiers, see page 81. 5. If you do not use the special sequence valve, plug the port (FP-SC-1/3). A Series Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 48 for the dimensions of mounting bracket. Flange Mtg. : A145-FR04E** Cable Departure 4 Cable Applicable : Outside Dia.... 8-10 mm Conductor Area...Not Exceeding 1.5mm End Cover Seal Cover Plain Washer Hex. Hd. Screw 3 Dia. M10 Thd. 19 Deep Outboard Pump Position Air Vent 3 Hex. Soc. Drain Port Rc3/4 Thd. Places Surface of Surface of Drain Port Dia. Dia. 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 5 Filling Port 1 (7 Hex. Head Plug Furnished) Surface of Suction Port Surface of Drain Port (with Plug) Eye Bolt Tilt Angle Sensor Connector Pressure Sensor Connector 3 3 Suction Port 48 Dia. M1 Thd. 19 Deep Case Drain Port 5 Hex. Soc. 1. Install the pump so that the Filling Port is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For cable connection with amplifiers, see page 81. 5. If you do not use the special sequence valve, plug the port (FP-SC-1/3). Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 49 for the dimensions of mounting bracket. Electro-Hydraulic Proportional Pressure & Flow Control Type 79

Amplifiers for Electro-Hydraulic Proportional Pressure & Flow Control Type Pumps SK1106- -*-*-10** Specifications Model No. SK1106- -*-*-10** Description Applicable Coil Resistance 10 Ω (0 ) Input Impedance 10 kω (PIN, QIN) Power Supply 4 V DC (1-8 V Included Ripple) Power Input (Max.) 30 W Input Signal Max. Flow / 5 V (QIN) Specified Pres. / 5 V (PIN) Output Signal for Sensor Monitor 5 V / Max. Flow (SMQ) 5 V / Specified Pres. (SMP) Ambient Temperature 0-50 Approx. Mass 450 g Detail of Connector Connector CN1 Solenoid CN Power Supply CN3 Pres. Sensor CN4 Tilt Angle Sensor CN5 Input/ Output Signal Name of Signal 1 Output to pilot valve solenoid 1 0 [V] (0 V) +4 [V] (4 V) 3 0 [V] 1 +5 [V] Power Supply for Sensor 0 [V] 3 Input Signal - Sensor 4 0 [V] 1 +8 [V] Power Supply for Sensor 0 [V] 3 Input Signal - Sensor 4 0 [V] 5 1 Input Signal - Flow (Qin) Input Signal - Common (COM) 3 Input Signal - Pres. (Pin) 4 Output Signal - Sensor Monitor P (SMP) 5 Output Signal - Sensor Monitor Q (SMQ) 6 0 [V] Solenoid Power Supply Fuse Pres. Sensor Tilt Angle Sensor Input/ Output Signal Frequency Select Switch View with the Cover Removed 80 Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Cable Connection Between Pump and Amplifier The cable connections between the proportional pilot valve and the sensor of the pump and the attached amplifier (SK1106) are shown below. The cable assemblies are not included in the pump assembly. Purchase separately with model number described in the below table if required. ASeries Piston Pump Detail of Connector (Pump Side) A Series Proportional Pilot Valve Pressure Sensor [HW900 connector, 3-pin(T type)sumitomo Wiring Systems] Terminal Number 1...Power...Output 3...0 V Tilt Angle Sensor [J series connector (Mark Ⅱ), 4-pin(17459-) : Tyco Electronics Japan G.K.] Tilt Angle Sensor Colour of Lead Wire Red : +4 V DC (Power Supply) White : 0 V (Power Supply) Shield : Ground Colour of Lead Wire Red : Qin (Input Signal, Flow) Black : C (0 V) White : Pin (Input Signal, Pressure) Yellow : SMP (Sensor Monitor, Pressure) Green : SMQ (Sensor Monitor, Flow) Pressure Sensor Terminal Number 1...Power...Output 3...0 V 4... Shield Wire Solenoid (GDM-11-B-11 : Yuken Kogyo Co., Ltd.) Terminal Number 1...Power Supply... Power Supply 3...Not Used Amplifier Model : SK1106----10 (For the details of amplifier, see the previous page.) Connector for Cable Ass'y Amplifier Side Housing Terminal Cable Core Size : AWG #18 - #4 Covered Dia. : 1.3-3. Dia. Strip Length : 3.0-3.5 mm : 5195-0*P (MOLEX) : 5194 (MOLEX) Sensor Side 1. Pressure Sensor Model : HW090 Housing : F (6189-0131) Retainer : F (6918-036) Terminal : F (1500-0106) Wire seal : S (7165-0118) (Sumitomo Wiring System). Tilt Angle Sensor Model : J series Connector(Mark Ⅱ) 4-pin(17457-) (Tyco Electronics Japan G.K.) 1. Cable assemblies are available. When ordering, specify the cable ass'y model numbers from the table below. Cable Ass'y Model Numbers Name of Cable Ass'y Approx. Length of Cable (mm) 000 5000 10000 15000 0000 5000 1 For Solenoid SK111-S--10 SK111--S-5-10 SK111-S-10-10 SK111-S-15-10 SK111-S-0-10 SK111-S-5-10 For Power Supply SK111-V--10 SK111-V-5-10 SK111-V-10-10 SK111-V-15-10 SK111-V-0-10 SK111-V-5-10 3 For Pressure Sensor SK111-P--10 SK111-P-5-10 SK111-P-10-10 SK111-P-15-10 SK111-P-0-10 SK111-P-5-10 4 For Tilt Angle Sensor SK111-Q--10 SK111-Q-5-10 SK111-Q-10-10 SK111-Q-15-10 SK111-Q-0-10 SK111-Q-5-10 5 For Signal SK111-C--10 SK111-C-5-10 SK111-C-10-10 SK111-C-15-10 SK111-C-0-10 SK111-C-5-10 Electro-Hydraulic Proportional Pressure & Flow Control Type 81

, OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type Input Signal for Pressure Control Safety valve Input Signal for Flow Control Amplifier Proportional Solenoid Pressure Sensor Control Valve Control Piston Performance Characteristics (S Input Voltage L) Output Flow 1 Pressure (S Input Voltage L) 1. Unloading pressure when input signal is 0 V.. Safety valve setting pressure Tilt Angle Sensor Bias Piston A16/A/A37/A56 Graphic Symbols A70/A90/A145 Example of Specified Control Pressure Control Pressure at Control Pressure Symbol (EX.) Input Signal is 5 V kgf/cm MPa 70 70 6.9 105 105 10.3 140 140 13.7 175 175 17. 10 10 0.6 7M 71.4 7 16M 163. 16 1M 14. 1 Model Number Designation A70 -F R 04EH 16M R S - -61 Series Number A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation Viewed (from End Shaft) R: Clockwise 1 (Normal) Control Type 04EH: "OBE" Type Proportional Pressure & Flow Control Type Pressure Control Level Control Pressure at Input Signal is 5 V (Refer to above Table) Amplifier Direction Port Position 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. Amplifier Compensation Number may differ according to the main machine conditions. Consult Yuken for detail. Viewed (from End Shaft) R: Right L: Left None: Axial Port S: Side Port S: Side Port Compensation Number Design Number 06 43 11 43 01 43 0 43 61 61 61 8 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Specifications Descriptions Model Numbers A16 A A37 A56 A70 A90 A145 Geometric Displacement cm 3 /rev 15.8. 36.9 56. 70.0 91.0 145.0 Operating Pressure MPa (PSI) Rated 16 16 16 16 5 5 5 Intermittent 1 1 16 1 1 8 8 8 Shaft Speed Range r/min 0-1800 Max. Flow L/min 8.4 40.0 66.4 101. 16.0 163.0 61.0 Flow Control Pressure Control Min. Pres. Required for Flow Adj. Hysteresis Repeatability Input Signal Min. Adjustment Pressure Hysteresis Repeatability Input Signal MPa.0 1 % or less 1 % or less Max. Flow / 5 V DC MPa 0.7 1 % or less 1 % or less Specified Control Pressure / 5 V DC Coil Resistance Ω [@ 0 ] 10 Input Impedance Flow Control : 10 kω Pres. Control : 10 kω Supply Electric Power 4 V DC (1-8 V Included Ripple) Power Input (Max.) W 30 Output Signal Flow 5 V DC / Max. Flow Pressure 5 V DC / Specified Control Pressure Alarm Signal Output (Open Collector) Voltage : Max. 30 V DC Current : Max. 40 ma Ambient Temperature 0-50 (With Circulated Air) Mass kg Flange Mtg. 0.7 0.7 3. 39. 64 76.5 98 Foot Mtg..9.9 36.5 43.5 76 97 13 A Series 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details. 3. Maximum flow differs to shaft speed. The value listed above indicates shaft speed of 1800 r/min. For other shaft speed calculate by the ratio of shaft speed. Pipe Flange Kits For Pipe flange, refer to form of pressure compensator type on page 3. Instructions Input Signal The pump is on unload condition when the pump is operated without input signal voltage. Electric Source Always turn off electric source whenever the connector for swash plate tilt angle sensor is removed. Compensation of Pump Maximum Regulated Flow at Frequency If the same maximum flow is required at 50 Hz or Hz, connect short plug in the amplifier to Hz at the place where supplied frequency is Hz. At this condition, maximum flow comes to the same value at 50 Hz. If short plug is used at Hz without making the change, maximum flow increased in proportion to frequency. Painting on Amp. Box and Solenoiod To maintain suitable radiation effect, the amp. box and the solenoid of the control valve should not be painted. OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type 83

Output Flow vs. Input Signal Output Flow L/min 3 4 16 8 1800 r/min 1500 r/min Output Flow L/min 10 100 80 40 0 1800 r/min 1500 r/min 0 1 3 4 Input Signal V DC 5 0 1 3 4 5 Input Signal V DC Output Flow L/min 45 40 30 0 10 1800 r/min 1500 r/min Output Flow L/min 150 15 100 75 50 5 1800 r/min 1500 r/min Output Flow L/min 0 80 40 0 1 3 4 5 Input Signal V DC 1800 r/min 1500 r/min Output Flow L/min 0 175 150 15 100 75 50 5 1 3 4 5 Input Signal V DC 1800 r/min 1500 r/min 0 1 3 4 5 Input Signal V DC 0 1 3 4 5 Input Signal V DC Note: Pump characteristics at 1800 r/min is the same as those at 1500 r/min where frequency is compensated. (Refer to page 74.) Output Flow L/min 80 40 00 1 10 80 40 1800 r/min 1500 r/min Full Cut-off Pres. vs. Input Signal 0 1 3 4 5 Input Signal V DC Full Cut-off Pressure Input Signal V DC Input Signal V DC Refer to page 35 to 4 for performance characteristics of pressure compensator type excluding characteristics appeared on this catalogue. Full Cut-off Pressure 84 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Axial Port Type Flange Mtg. : A16-FR04EH* A-FR04EH* See 150.5 144 Air Vent 3 Hex. Soc. Electrical Conduit Connection G 1/ Thd. 39 44.5 1 6.5 59 6.5 Filling Port 1 ( Hex. Head Plug Furnished) 5 Drain Port Rc3/8 Thd. A Series 19 Dia. 47.6 51 173 138 1.4 1.08 96 X Suction Port 19 Dia. 65 145 94. M10 Thd. 17 Deep 8 Places 17 1 19.05 Dia. 19.0 Dia. 8.55 8.50 1. Install the pump so that the "Filling Port" is at the top.. Do not touch the screw because it is adjusted at the time of shipment. 3. For detail of amplifier, refer to page 90. 4.79 4.76 Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 44 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. 11 95 Dia. 106 130 View Arrow X R1 18 Axial Port Type Flange Mtg. : A37-FR04EH* See 15.5 146 Air Vent 3 Hex. Soc. Electrical Conduit Connection G 1/ Thd. 61.5 59 43.5 9.5 77 30 3 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. 3 Dia. 67 177 14 105 X 58.7 Suction Port 30. 3 Dia. 7 149 101 M10 Thd. 19 Deep 8 Places 195 1 Dia..3.0 5.01 4.85 101. Dia. 101.55 1. Install the pump so that the "Filling Port" is at the top.. Do not touch the screw because it is adjusted at the time of shipment. 3. For detail of amplifier, refer to page 90. 6.38 6.35 Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 45 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 45 for the dimensions of mounting bracket. 14 10 Dia. 146 174 View Arrow X R14 5 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type 85

Axial Port Type Flange Mtg. : A56-FR04EH* 1 Filling Port (4 Hex. Head Plug Furnished) 74 6 15.5 Air Vent 3 Hex. Soc. 56 50.5 9.5 146 Electrical Conduit Connection G 1/ Thd. 43.5 Drain Port Rc3/4 Thd. (Both Sides) See 3 40 3 Dia. 300 58.7 0 167 90 X Suction Port 35 Dia. 30. M10 Thd. 19 Deep 8 Places 1 Dia. 31.75 31.70 35.5 35.14 Dia. 101. 101.55 76 07 163.5 116 Surface of Drain Port 41 49 7.97 7.94 14 5 R14 10 Dia. 146 174 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 90. View Arrow X Side Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 46 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 46 for the dimensions of mounting bracket. 86 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Flange Mtg. Amplifier Direction "L" : A70-FR04EH*LS Surface of Drain Port Surface of 107 157 Surface of Suction Port A Series 314 6 95 95 Drain Port Rc3/4 Thd. (Both Sides) 65 19.5 9.5 Air Vent 3 Hex. Soc. Electrical Conduit Connection G 1/ Thd. 89 73 73 Surface of Drain Port 5 Plug Hex. Soc. 5.4 6 Dia. M10 Thd. 17 Deep 6. 16 18 40 31.75 Dia. 31.70 35.3 35.14 17.00 Dia. 16.95 90 179.5 18 14 35 Dia. Spotface (Rear Side) Places 114.4 134 7.97 7.94 114.4 180 118 13.5 7 Dia. Spotface (Rear Side) X 46.5 181 306.5 11 Amplifier Direction "R": A70-FR04EH*RS Surface of Electrical Conduit Connection Eye Bolt M10 1 Filling Port ( Hex. Head Plug Furnished) 117.5 3 69.9 Case Drain Port 5 Hex. Soc. 46.5 35.7 Suction Port 38 Dia. M1 Thd. 19 Deep 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 90. 5. If you use the special sequence valve, remove the plug. View Arrow X Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 47 for the dimensions of mounting bracket. OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type 87

Flange Mtg. Amplifier Direction "L" : A90-FR04EH*LS Surface of Electrical Conduit Connection 13.7 95 107 157 Surface of Drain Port Drain Port Rc3/4 Thd. (Both Sides) 119.5 13 3 63 Electrical Conduit Connection G1/ Thd. 89 68 68 Air Vent 3 Hex. Soc. 5 Plug Hex. Soc. 58.7 3 Dia. M10 Thd. 19 Deep 30. 38.10 Dia. 38.05 4.36 4.18 Dia. 15.40 15.35 113 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 9.56 9.53 161.6 R 161.6 189 17 3 X 3 105 105 70 Surface of Surface of Suction Port 34 Amplifier Direction "R": A90-FR04EH*RS 1 Filling Port (7 Hex. Head Plug Furnished) 77.8 Eye Bolt M10 3 Suction Port 48 Dia. 70 4.9 M1 Thd. 19 Deep View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 90. 5. If you use the special sequence valve, remove the plug. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 48 for the dimensions of mounting bracket. 88 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS Flange Mtg. Amplifier Direction "L" : A145-FR04EH*LS Surface of Electrical Conduit Connection 149.5 11 89 3 107 171.5 Surface of Drain Port 89 Air Vent 3 Hex. Soc. A Series Drain Port Rc3/4 Thd. (Both Sides) 13 7 7 70 Electrical Conduit Connection G1/ Thd. 5 Plug Hex. Soc. 58.7 3 Dia. M10 Thd. 19 Deep 30. 99.5 357.5 4 6 44.45 Dia. 44.40 49.39 49.1 Dia. 15.40 15.35 110 11.14 11.11 R Surface of 11 11 8.6 73 8.6 191 141 5 1.5 Dia. Through 39 Dia. Spotface (Rear Side) Surface of Suction Port X Amplifier Direction "R": A145-FR04EH*RS 1 Filling Port (7 Hex. Head Plug Furnished) Eye Bolt M10 77.8 3 Suction Port 48 Dia. Case Drain Port 5 Hex. Soc. 99.5 4.9 M1 Thd. 19 Deep View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. For detail of amplifier, refer to page 90. 5. If you use the special sequence valve, remove the plug. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 49 for the dimensions of mounting bracket. OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type 89

Detail of Amplifier Connecting Terminal LED for Power Supply 50/ Hz Short Plug P GAIN CMG FMG LQC DITHER FUSE Hz 50Hz Compensation Cartridge 4 V 0 V ALM C ALM S SMQ SMP Q IN C P IN C H SPARE FUSE Connector for Tilt Angle Sensor Terminal P IN C Q IN SMP SMQ 0 V 4 V ALM S ALM C CH Name Input Signal, Pressure (+) Input Signal (COM) Input Signal, Flow (+) Sensor Monitor Output, Pressure Sensor Monitor Output, Tilt Angle Power Supply Alarm Output Alarm Output (COM) Output Current Check (to COM) Note 1. For "SENSOR MONITOR" terminal, external instruments should have input impedance of more than 10 kω.. For "CH" terminal, external instruments should have input impedance of more than 10 kω. 3. Volume adjustment of "DITHER", "GAIN", "CMG", "FMG" and "LQC" is made at the time of shipment. Adjustment at the customer is not required. 4. Use shielded cable for "Input" connection. The ground of the shielded cable must be connected to input signal side. Circuit Schematic ALARM SIG COM P SENSOR MONITOR PRESS. SENSOR P IN A C P GAIN ALARM LQC Q IN D A CMG OSC CH DITHER POSITION SENSOR FMG 4 V 0 V Q SENSOR MONITOR 90 OBE Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PISTON PUMPS, Two-Pressure Two-Flow Control Type By System Pressure Graphic Symbol Output Flow Performance Characteristics A Series Pressure Specifications Model Numbers Geometric Displacement cm 3 /rev Deliverry Volume Adj. Range cm 3 /rev Large Displacement (QH) Small Displacement (QL) Operating Pressure MPa A16-*-R-05-**-S-K-3 15.8.6-15.8.6-11.1 16 1 A37-*-R-05-**-S-K-3 36.9 4.1-36.9 4.1-0.1 16 1 A56-*-R-05-**-S-K-3 56. 3.4-56. 3.4-5.1 16 1 Shaft Speed Range r/min Rated Intermittent Max. Min. 1800 0 Model Number Designation A16 -F -R -05 -B C -S -K -3 Series Number Mounting A16 (15.8 cm 3 /rev) F: Flange Mtg. A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise (Normal) Control Type 05: Two Pressure Two Flow Control Type by System Pressure Pres. Adj. Range for High Pressure MPa B:.5-7 C:.5-16 H:.5-1 Pres. Adj. Range for Low Pressure MPa B:.5-7 C:.5-16 H:.5-1 Port Position None: Axial Port S: Side Port Shaft Extension K: Keyed Shaft Design Number 3 3 3 Consult Yuken when detailed such as dimensions figures is required. Two-Pressure Two-Flow Control Type By System Pressure 91

, Two-Pressure Two-Flow Control Type By Solenoid Valve Graphic Symbol Performance Characteristics Output Flow Pressure A16/A/A37/A56 A70/A90/A145 Specifications Model Numbers Geometric Displacement cm 3 /rev Deliverry Volume Adj. Range cm 3 /rev Large Displacement (QH) Small Displacement (QL) Operating Pressure MPa A16-*-R-06-**-S-K-*-33 15.8.6-15.8.6-11.1 16 1 A-*-R-06-**-S-K-*-33. 3.7 -. 3.7-15.5 16 16 A37-*-R-06-**-S-K-*-33 36.9 4.1-36.9 4.1-0.1 16 1 A56-*-R-06-**-S-K-*-33 56. 3.4-56. 3.4-5.1 16 1 A70-*R06S*- 70.0 36-70.0 3-70.0 5 5 A90-*R06S*- 91.0 56-91.0 3-70.0 5 5 A145-*R06S*- 145 83-145 3-145 5 5 Model Number Designation Shaft Speed Range r/min Rated Intermittent Max. Min. 1800 0 A16 -F -R -06 -B C -S -K A00-33 Series Number A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise (Normal) Control Type 06: Two-Pressure Two-Flow Control Type by Solenoid Valve Pres. Adj. Range for High Pressure MPa B:.5-7 C:.5-16 H:.5-1 Pres. Adj. Range for Low Pressure MPa B:.5-7 C:.5-16 H:.5-1 A70 -F R 06 S A00 - Series Number A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise (Normal) Control Type 06: Two-Pressure Two-Flow Control Type by Solenoid Valve Port Position Coil Type of Solenoid Valve AC A100, A10 A00, A40 S: DC Side Port D1, D4 D48 R(AC DC Rectifild) R100, R00 Port Position S: Side Port Design Number Shaft Extension K: Keyed Shaft Coil Type of Solenoid Valve AC A100, A10 A00, A40 DC D1, D4 D48 R(AC DC Rectifild) R100, R00 Design Number 33 33 33 33 Consult Yuken when detailed such as dimensions figures is required. 9 Two-Pressure Two-Flow Control Type By Solenoid Valve

PISTON PUMPS, Pilot Pressure Control Type Pressure Compensator Graphic Symbol M O Performance Characteristics Output Flow A Series Specifications Model Numbers Geometric Displacement cm 3 /rev Minimum Adj. Flow cm 3 /rev Pressure Operating Pressure Shaft Speed Range Minimum MPa r/min Adj. Pres. Rated Intermittent 1 MPa Max. Min. Approx. Mass kg A10-FR07-1 10.0 16 1.0 1800 0 8.5 10.7 A16-*-R-07-*-K-3 15.8 4 16 1 1. 1800 0 1 3. A-*-R-07-*-K-3. 6 16 16 1. 1800 0 1 3. A37-*-R-07-*-K-3 36.9 10 16 1 1. 1800 0 9 33.3 A56-*-R-07-*-K-3 56. 1 16 1 1. 1800 0 36 40.3 A70-*R07S- 70.0 36 5 5 1800 0.3 7.3 A90-*R07S- 91.0 56 5 5 1800 0 77.5 98 A145-*R07S- 145 83 5 5 1800 0 94 119 1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details. Model Number Designation A16 -F -R -07 -S -K -3 Series Number Mounting Direction of Rotation Control Type Port Position Shaft Extension Design Number A16 (15.8 cm 3 /rev) A (. cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) F: Flange Mtg. L: Foot Mtg. ( Viewed from Shaft End ) R: Clockwise 1 (Normal) 07: Pilot Pressure Control Type Pressure Compensator None: Axial Port S: Side Port K: Keyed Shaft A70 -F R 07 S - Series Number Mounting Direction of Rotation Control Type Port Position Design Number A10 (10.0 cm 3 /rev) A70 (70.0 cm 3 /rev) F: A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) F: Flange Mtg. Flange Mtg. L: Foot Mtg. ( Viewed from Shaft End ) R: Clockwise 1 (Normal) 07: Pilot Pressure Control Type Pressure Compensator 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. When A10 pump is used as the foot Mtg., order the Mtg. Bracket kit shown below separately. Refer to page 0 for dimensions of the Mtg. bracket. 3. Please inquire for A0 separatery. 1 S: Side Port Flange Mtg. 3 3 3 3 Foot Mtg. Mtg. Bracket Kit Numbers Approx. Mass kg LP-1A-10. Note: The mounting bracket kit consists of a mounting bracket, hex. bolts and plain washer. Pilot Pressure Control Type Pressure Compensator 93

Performance Characteristics For performance characteristics, refer to models of pressure compensator type on page 34 to 4. Pipe Flange Kit For pipe flange, refer to form of pressure compensator type on page 3. Flange Mtg. : A10-FR07 Pilot Port "PP" Rc1/4 Thd. Fully Extended Safety Valve 96.5 Pressure Adj. Screw 3 Hex. Soc. 33 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc3/8 Thd. Fully Extended 180 170 44.5 90.5 6.5 3 INC. Flow Adj. Screw 13 Hex. DEC. 3 Suction Port Rc1/ Thd. 9 5 5 64.5 64.5 171 107 41 Rc1/ Thd. 3 5.5 10.5 131 156 5 19.05 Dia. 19.0 1.4 1.08 8.55 8.50 Dia. 65 93 Dia. 106 130 11 4.79 4.76 159.5 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two suction and discharge ports at your option. Keep the remaining ports plugged. 3. As the tightening torques of suction, discharge and drain port fittings, conform to the below. Model Numbers Tightening Torque Nm Suction Port & Drain Port A10-FR07-1 65-75 40-50 94 Pilot Pressure Control Type Pressure Compensator

PISTON PUMPS Axial Port Type Flange Mtg. : A16-F-R-07-K A-F-R-07-K Pilot Port "PP" Rc3/8 Thd. Fully Extended 7 0 187 44.5 A Series 6.5 59 6.5 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc3/8 Thd. 5 4.79 4.76 X 187 109 8.5 6 1 19.05 19.0 Dia. 1.4 1.08 8.55 8.50 Dia. 96 1 95 Dia. 106 18 R1 17 Surface of Suction and 130 188 Flow Adj. Screw 5 Hex. Soc. DEC. Safety Valve Pressure Adj. Screw 17 Hex. 16 43.5 18 Pilot Port "PP" Rc1/4 Thd. INC. 65 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot ports at your option. Keep the remaining port plugged. 47.6 Suction Port 19 Dia.. 65 View Arrow X M10 Thd. 17 Deep 8 Places 19 Dia. Axial Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 44 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. Pilot Pressure Control Type Pressure Compensator 95

Side Port Type Flange Mtg. : A37-F-R-07-S-K Fully Extended 50 Pilot Port "PP" Rc3/8 Thd. 5 10 59 77 9.5 30 1 Filling Port ( Hex. Head Plug Furnished) Drain Port Rc1/ Thd. 3 6.38 6.35 X 0 11 88.5 68 58.7 105 14 5 M10 Thd. 19 Deep (Both Sides) 30. 1.3 Dia..0 5.01 4.85 101. 101.55 Dia. 10 Dia. 146 R14 3 Dia. (Rear Side) Suction Port 3 Dia. 178.5 174 0 Flow Adj. Screw 5 Hex. Soc DEC. Safety Valve Pressure Adj. Screw 17 Hex. 46.5 13 1 Pilot Port "PP" Rc1/4 Thd. INC. 71 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot ports at your option. Keep the remaining port plugged. 86 86 Surface of Suction Port Surface of View Arrow X Axial Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 46 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 46 for the dimensions of mounting bracket. 96 Pilot Pressure Control Type Pressure Compensator

PISTON PUMPS Side Port Type Flange Mtg. : A56-F-R-07-S-K Pilot Port "PP" Rc3/8 Thd. Fully Extended 6.5 37.5.5 6 50.5 9.5 1 Filling Port ( Hex. Head Plug Furnished) A Series 43.5 Drain Port Rc3/4 Thd. (Both Sides) Surface of Drain Port 41 49 40 7.97 7.94 X 36 138 97.5 90 77 58.7 14 5 M10 Thd. 19 Deep (Both Sides) 30 Dia. (Rear Side) Suction Port 35 Dia. 30. 1 191 31.75 31.70 Dia. 35.3 35.14 101. 101.55 Dia. 10 Dia. 146 174 3 R14 Flow Adj. Screw 5 Hex. DEC. Safety Valve Pressure Adj. Screw 17 Hex. 46.5 13 1 Pilot Port "PP" Rc1/4 Thd. INC. 80 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged. 100 100 Surface of Suction Port Surface of View Arrow X Axial Port Type Port mounting dimensions are the same as those of pressure compensator model. Refer to page 47 for port mounting dimensions. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 47 for the dimensions of mounting bracket. Pilot Pressure Control Type Pressure Compensator 97

Flange Mtg. : A70-FR07S Fully Extended 351.5 6 Drain Port Rc3/4 Thd. (Both Sides) Surface of Surface of Drain Port 95 95 73 73 Surface of Suction Port Surface of Drain Port 65 9.5 7 Dia. Spotface (Rear Side) 13 X 40 5.4 90 180.5 18 114.4 180 18 14 7.97 7.94 Y 6 Dia. M10 Thd. 17 Deep 6. 46.5 19.5 16 18 31.75 31.70 Dia. 35.3 35.14 17.00 16.95 Dia. 35 Dia. Spotface (Rear Side) Places 114.4 134 181 11 118 316.5 Surface of Pilot Port "PP1" Pilot Port "PP" Rc1/4 Thd. Pilot Port "PP1" Rc1/4 Thd. Safety Valve Pres. Adj. Screw 14 Hex. INC. Eye Bolt M10 1 Filling Port ( Hex. Head Plug Furnished) 44 165.5 View Arrow X Flow Adj. Screw 17 Hex. DEC. Case Drain Port 5 Hex. Soc. 3 35.7 69.9 Suction Port 38 Dia. M1 Thd. 19 Deep 46.5 View Arrow Y 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 48 for the dimensions of mounting bracket. 98 Pilot Pressure Control Type Pressure Compensator

PISTON PUMPS Flange Mtg. : A90-FR07S Drain Port Rc3/4 Thd. (Both Sides) 119.5 95 3 13 Surface of Surface of Drain Port 105 105 68 68 Surface of Suction Port Surface of Drain Port A Series X 58.7 3 Dia. M10 Thd. 19 Deep Pilot Port "PP1" Rc1/4 Thd. 30. 70 9.5 17.5 3 63 38.10 Dia. 38.05 4.36 4.18 15.40 15.35 Dia. Case Drain Port 5 Hex. Soc. 3 1 113 Eye Bolt M10 Filling Port (7 Hex. Head Plug Furnished) 161.6 1.5 Dia. Through 39 Dia. Spotface (Rear Side) Fully Extended 376 341 68.5 161.6 9.56 9.53 R 17 190 190.5 Surface of Pilot Port "PP1" Pilot Port "PP" Rc1/4 Thd. Safety Valve Pres. Adj. Screw 14 Hex. INC. 170 Flow Adj. Screw 17 Hex. DEC. Y 77.8 88 View Arrow X 70 4.9 View Arrow Y Suction Port 48 Dia. M1 Thd. 19 Deep 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 49 for the dimensions of mounting bracket. Pilot Pressure Control Type Pressure Compensator 99

Flange Mtg. : A145-FR07S Drain Port Rc3/4 Thd. (Both Sides) Surface of Surface of Suction Port Fully Extended 400.5 89 11 3 13 Surface of Drain Port 11 11 7 7 15 Surface of Drain Port X 58.7 70 110 11.14 11.11 8.6 198.5 3 Dia. M10 Thd. 19 Deep 30. 4 6 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 8.6 73 141 R 99.5 Case Drain Port 5 Hex. Soc. 3 Pilot Port "PP1" Rc1/4 Thd. 4 Safety Valve Pres. Adj. Screw 14 Hex. INC. Flow Adj. Screw 17 Hex. DEC. 1 Eye Bolt M10 Filling Port (7 Hex. Head Plug Furnished) 36.5 90 Surface of Pilot Port "PP1" Pilot Port "PP" Rc1/4 Thd. 177 19 Suction Port 48 Dia. 77.8 Y 44.45 44.40 Dia. 49.39 49.1 15.40 15.35 Dia. View Arrow X M1 Thd. 19 Deep 4.9 99.5 View Arrow Y 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two pilot and drain ports at your option. Keep the remaining ports plugged. 3. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 50 for the dimensions of mounting bracket. 100 Pilot Pressure Control Type Pressure Compensator

PISTON PUMPS, Constant Power Control Type Performance Characteristics Output Flow A Series Output Flow Input Power Input Power Pressure Graphic Symbol PP P PP P M O M O S DR M O S DR M O A16 A37 A56 A70/A145 Specifications Model Numbers Geometric Displacement cm 3 /rev Minimum Adj. Flow cm 3 /rev Operating Pres. MPa Shaft Speed Range r/min Max. Max. Min. Flange Mtg. Approx. Mass kg A16-*-R-09-*-*-K-3 15.8 1 1 1800 0 9.0 31. A37-*-R-09-*-*-K-3 36.9 1 1 1800 0 37.0 41.3 A56-*-R-09-*-*-K-3 56. 1 1 1800 44.0 44.0 48.3 A70-*R09*S- 70.0 36 5 1800 0 7.8 84.8 A145-*R09*S- 145 83 5 1800 0 110 135 1. Maximum Operating Pressure of A16/A37/A56 varies according to Input Power Setting. See Model Number Designation for details.. Minimum Adjustment Flow of A70/A145 is absolutely minimum flow that can be adjusted with Flow Adjustment Screw. Foot Mtg. A90 type pump (91 cm 3 /rev) is available. Ask Yuken for Details. Constant Power Control Type 101

Model Number Designation A16/A37/A56 A16 -F -R -09 -A -16M -K -3 Series Number A16 (15.8 cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) Mounting F: Flange Mtg. L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise 1 (Normal) Control Type Input Power Setting Specify Control Pres. 09: Constant Power Control Type A : 3.7 kw B : 5.5 kw A : 3.7 kw B : 5.5 kw A : 3.7 kw B : 5.5 kw C : 7.5 kw D : 11 kw E :. kw F : 1.5 kw 7M : 7 Pa C : 7.5 kw D : 11 kw E : 15 kw F : 18.5 kw G : kw 10.5M : 10.5 Pa 14M : 14 Pa 16M : 16 Pa 17.5M : 17.5 Pa 1M : 1 Pa Shaft Extension K: Keyed Shaft A70/A145 A70 -F R 09 -A S - Series Number Mounting A70 (70 cm 3 /rev) F: Flange Mtg. A145 (145 cm 3 /rev) L: Foot Mtg. Direction of Rotation ( Viewed from Shaft End ) R: Clockwise 1 (Normal) Control Type Input Power Setting Direction of Port 09: Constant Power Control Type A : 15 kw B : 18.5 kw A : 15 kw B : 18.5 kw C : kw D : 30 kw C : kw D : 30 kw E : 37 kw F : 45 kw G : 55 kw H : 75 kw S: Side Port 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.. Specify control pressure of A16/A37/A56 with lower than Maximum Operating Pressure depending on Input Power Setting Design Number 3 3 3 Design Number Performance Characteristics Maximum Operating Pressure MPa Model 1.5 kw. kw 3.7 kw 5.5 kw 7.5 kw 11 kw 15 kw 18.5 kw kw A16 10.5 16 1 1 A37 16 1 1 1 A56 10.5 14 17.5 1 1 1 1 Pipe Flange Kits Pipe flange kits are available. When ordering, specify the kit number from the table below. Pump Model Pipe Flange Kit Numbers Name of Port Numbers Threaded Connection Socket Welding 1 Butt Welding A16-*-R-09 Suction F5-06-A-10 F5-06-B-10 F5-06-C-10 Discharge A37-*-R-09 Suction F5-10-A-10 F5-10-B-10 F5-10-C-10 A56-*-R-09 Discharge F5-06-A-10 F5-06-B-10 F5-06-C-10 A70-*-R-09 Suction F5-1-A-10 F5-1-B-10 F5-1-C-10 Discharge F5-08-A-10 F5-08-B-10 F5-08-C-10 A145-*-R-09 Suction F5-16-A-10 F5-16-B-10 F5-16-C-10 Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10 1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of hat flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.. Discharge port for pump model "A16" is available only the threaded connections. Detail of the pipe flange kits are shown on page 6. 10 Constant Power Control Type

PISTON PUMPS Typical Performance Characteristics at 1500 r/min Output Flow L/min 30 0 10 0 Output Flow 5.5 kw Input Power 3.7 kw. kw 1.5 kw 1 0 3.5 7 10.5 14 17.5 1 Pressure MPa 6 5 4 3 Input Power kw Output Flow L/min 00 150 100 50 Output Flow Input Power 30 kw kw 18.5 kw 30 kw kw 18.5 kw 15 kw 40 35 30 5 0 15 10 5 Input Power kw A Series 15 kw 0 0 10 0 30 Pressure MPa Output Flow L/min 50 40 30 0 10 0 11 kw Output Flow 1 Input Power 10 7.5 kw 5.5 kw 3.7 kw 0 3.5 7 10.5 14 17.5 1 Pressure MPa 8 6 4 Input Power kw Output Flow L/min 300 Output Flow 00 100 30 kw 37 kw 45 kw Input Power 55 kw kw 55 kw 45 kw 37 kw 30 kw kw 75 70 50 40 30 0 10 Input Power kw 0 0 10 0 30 Pressure MPa 10 5.5 kw 7.5 kw11 kw 15 kw kw 18.5 kw 4 Input Power 100 Output Flow 0 Output Flow L/min 80 40 0 0 3.7 kw 0 3.5 7 10.5 14 17.5 1 Pressure MPa 10 Input Power kw Constant Power Control Type 103

Flange Mtg. : A16-F-R-09-*-K Surface of Suction Port Filling Port ( Hex. Head Plug Furnished) 57 44.5 9 6.5 17 6.5 Drain Port Rc3/8 Thd. 130 106 X Fully Extended 111 5 96 4.79 4.76 R1 78 1 19.05 19.0 Dia. 1.4 1.08 Dia. 8.55 8.50 18 Fully Extended 45 63.5 47.6 1 95 Dia. 5 Pressure Adj. Screw 3 Suction Port 19 Dia. M10 Thd. 19 Deep. 3.5 56 94 87 View Arrow X Input Power Setteing Screw G1/ Thd. 3 17 34 Dia. 15.6 Dia. 0.5.5 G1/ Thd. 1. Detail of. Install the pump so that the "Filling Port" is at the top. 3. Do not touch the screw because it is adjusted at the time of shipment. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 44 for the dimensions of mounting bracket. 104 Constant Power Control Type

PISTON PUMPS Flange Mtg. : A37-F-R-09-*-K 1 Filing Port ( Hex. Head Plug Furnished) 30 59 9.5 3 Drain Port Rc1/ Thd. 101 101 A Series X Fully Extended 155 90 7 Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 8 195 1.3.0 Dia. 5.01 4.85 Dia. 101. 101.55 105 R14 10 Dia. 146 174 6.38 6.35 Fully Extended 141 7 30.. 36 4 14 Dia. Through 8 Dia. Spotface 3 14 15 10 58.7 14 47.6 85 5 8 Surface of Suction Port Pressure Adj. Screw Pilot Port Rc1/4 Thd. Input Power Setting Screw Rc1/4 Thd. Suction Port 30 Dia. 0 Dia. 1. Install the pump so that the "Filling Port" is at the top.. Do not touch the screw because it is adjusted at the time of shipment. M10 Thd. 19 Deep M10 Thd. 19 Deep View Arrow X Foot Mtg. : A37-L-R-09-*-K 74 115 39 10 95 95 30 For other dimensions, refer to Flange Mtg.. Constant Power Control Type 105

Flange Mtg. : A56-F-R-09-*-K 1 Filling Port ( Hex. Head Plug Furnished) X 98 161 Drain Port Rc3/4 (Both Sides) 90 7 07 50.5 43.5 6 9.5 1 40 31.75 Dia. 31.70 35.3 35.14 101. 101.55 Dia. Surface of Drain Port 5 14 R14 7.97 7.94 41 49 146 Surface of Drain Port 10 Dia. Pressure Gauge Connection for Pump Discharge Pressure Rc1/4 Thd. 94 40 Surface of Suction Port 174 3 Pressure Adj. Screw Fully Extended 141 7 3 Pilot Port Rc1/4 Thd. Input Power Setting Screw 3 Suction Port 35 Dia. 94 58.7 M10 Thd. 19 Deep 14 Dia. Through 8 Dia. Spotface 3 14 15 10 0 Dia. 47.6 M10 Thd. 19 Deep 30.. 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 38 44 View Arrow X Foot Mtg. : A56-L-R-09-*-K-3 77 115 4 10 95 95 30 For other dimensions, refer to Flange Mtg.. 106 Constant Power Control Type

PISTON PUMPS Flange Mtg. : A70-FR09*S M10 Thd. 17 Deep Drain Port Rc3/4 Thd. (Both Sides) Fully Extended 351.5 6 65 19.5 9.5 40 7 Dia. Spotface (Rear Side) 4 places 188 Surface of Drain Port 73 95 73 Surface of Suction Port Surface of Drain Port A Series Y 6. 90 180.5 7.97 7.94 18 18 X 1.5 18 17.00 16.95 Dia. 114.4 134 118 181 11 69.9 114.4 180 18 Dia. 5.4 31.75 Dia. 31.70 35.3 35.14 14 35 Dia. Spotface (Rear Side) places Input Power Setting Screw "A" 3 Input Power Setting Screw "B" 3 Safety Valve Pressure Adj. Screw 14 Hex. INC. Flow Adj. Screw 17 Hex. DEC. 1 Filling Port ( Hex. Head Plug Furnished) Eye Bolt M10 Suction Port 38 Dia. View Arrow Y Case Drain Port 5 Hex. Soc. 4 46.5 35.7 M1 Thd. 19 Deep View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 47 for the dimensions of mounting bracket. Constant Power Control Type 107

Flange Mtg. : A145-FR09*S Input Power Setting Screw "B" 3 Input Power Setting Screw "A" 57 3 Dia. 30. M10 Thd. 19 Deep 58.7 3 Case Drain Port 5 Hex. Soc. Fully Extended 397 4 YUKEN 99.5 4 89 Drain Port Rc3/4 Thd. (Both Sides) 11 Surface of 14 3 Surface of Drain Port 13 70 44.45 44.40 Dia. 49.39 49.1 Dia. 15.40 15.35 110 Fully Extended 46 1.5 Dia. Through 39 Dia. Spotface (Rear Side) 11 7 7 8.6 73 Surface of Suction Port Surface of Drain Port 11.14 11.11 8.6 R 141 198.5 X Eye Bolt M10 1 Filling Port (7 Hex. Head Plug Furnished) INC. Pressure Adj. Screw 17 Hex. Flow Adj. Screw 17 Hex. DEC. Suction Port 48 Dia. 77.8 4.9 M10 Thd. 19 Deep 99.5 View Arrow X 1. Install the pump so that the "Filling Port" is at the top.. Use either port of two drain ports at your option. Keep the remaining port plugged. 3. Do not touch the screw because it is adjusted at the time of shipment. 4. Case drain port is available for use when draining hydraulic fluid from pump casing. Foot Mounting Type Mounting bracket is common to that of pressure compensator model. Refer to page 49 for the dimensions of mounting bracket. 108 Constant Power Control Type

PISTON PUMPS - Single Pump, Simple Two-Pressure Two-Flow Control Type Specifications Model Numbers Geometric Displacement cm 3 /rev Output Flow Adj. Range cm 3 /rev Large Small Displacement Displacement (QH) (QL) Operating Pressure MPa Rated Intermittent A16-*-R-00-H-K-3500 15.8 4-15.8 3-10 16 1 Shaft Speed Range r/min Output Flow Performance Characteristics A Series A37-*-R-00-H-K-3500 36.9 7-36.9 3-18 16 1 A56-*-R-00-H-K-3500 56. 9-56. 3-7.7 16 1 A70-*R00HS-500 70.0 36-70.0-4 1 1 0-1800 Pressure A90-*R00HS-500 91 56-91.0-45 1 1 Graphic Symbol A145-*R00HS-500 145 83-145 -70 1 1 Note) : Minimum adjustment flow of relief valve, which is for setting with PH pressure. (Relief valve is external set.) Instruction As the pump does not have Full-Cut off function, setting relief valve of PH pressure (Maximum Pressure on circuit) for pump discharge line is absolutely required. Model Number Designation A16-A56 A16 F R 00 H K 3500 Series Number Mounting Direction of Rotation Control Type Pres. Adj. Range MPa Shaft Extension Design Number A16 (15.8 cm 3 /rev) A37 (36.9 cm 3 /rev) A56 (56. cm 3 /rev) F : Flange Mtg L : Foot Mtg. (Viewed from Shaft End) R : Clockwise (Normal) 00 : Special Control Type H : 1.-1 K : Keyed Shaft 3500 3500 3500 A70-A145 A70 F R 00 H S 500 Series Number Mounting Direction of Rotation Control Type Pres. Adj. Range MPa Port Position Design Number A70 (70.0 cm 3 /rev) A90 (91.0 cm 3 /rev) A145 (145 cm 3 /rev) F : Flange Mtg L : Foot Mtg. (Viewed from Shaft End) R : Clockwise (Normal) 00 : Special Control Type H : -1 S : Side Port 500 Available to supply pump with anti-clockwise rotation. Consult Yuken for details. Consult Yuken when detailed material such as dimensions figures is required. Simple Two-Pressure Two-Flow Control Type 109

Double Pumps, Pressure Compensator Type Graphic Symbol M O M O Specifications Model Numbers Geometric Displacement cm 3 /rev Min.Adj. Flow cm 3 /rev Operating Pressure MPa Shaft Speed Range r/min Rated Intermittent Max. Min. Approx. Mass kg Flange Mtg. Foot Mtg. A1616-*R01*01**K-3 Outboard Pump 15.8 4 16 1 1800 0 35.5 37.7 Inboard Pump 15.8 4 16 1 A16-*R01*01**K-3 Outboard Pump 15.8 4 16 1 1800 0 35.5 37.7 Inboard Pump. 6 16 16 A-*R01*01**K-3 Outboard Pump. 6 16 16 1800 0 35.5 37.7 Inboard Pump. 6 16 16 A1637-*R01*01**K-3 Outboard Pump 15.8 4 16 1 1800 0 50 54.3 Inboard Pump 36.9 10 16 1 A37-*R01*01**K-3 Outboard Pump. 6 16 16 1800 0 50 54.3 Inboard Pump 36.9 10 16 1 A1656-*R01*01**K-3 Outboard Pump 15.8 4 16 1 1800 0 54.5 58.8 Inboard Pump 56. 1 16 1 A56-*R01*01**K-3 Outboard Pump. 6 16 16 1800 0 54.5 58.8 Inboard Pump 56. 1 16 1 A1670-*R01*01**- A70-*R01*01**- A3770-*R01*01**- A1690-*R01*01**- A90-*R01*01**- A3790-*R01*01**- A5690-*R01*01**- Outboard Pump 15.8 4 16 1 Inboard Pump 70.0 36 5 8 Outboard Pump. 6 16 16 Inboard Pump 70.0 36 5 8 Outboard Pump 36.9 10 16 1 Inboard Pump 70.0 36 5 8 Outboard Pump 15.8 4 16 1 Inboard Pump 91.0 56 5 8 Outboard Pump. 6 16 16 Inboard Pump 91.0 56 5 8 Outboard Pump 36.9 10 16 1 Inboard Pump 91.0 56 5 8 Outboard Pump 56. 1 16 1 Inboard Pump 91.0 56 5 8 1800 0 77.5 89.5 1800 0 77.5 89.5 1800 0 86.5 98.5 1800 0 88 108.5 1800 0 88 108.5 1800 0 100.5 11 1800 0 107.5 18 A16145-*R01*01**- Outboard Pump 15.8 4 16 1 1800 0 109 134 Inboard Pump 145 83 5 8 A145-*R01*01**- Outboard Pump. 6 16 16 1800 0 109 134 Inboard Pump 145 83 5 8 A37145-*R01*01**- Outboard Pump 36.9 10 16 1 1800 0 11.5 146.5 Inboard Pump 145 83 5 8 A56145-*R01*01**- Outboard Pump 56. 1 16 1 1800 0 18.5 153.5 Inboard Pump 145 83 5 8 Consult Yuken when detailed material such as dimensions figures is required. 110 Double Pumps, Pressure Compensator Type

PISTON PUMPS Model Number Designation A1637 -F -R Series Number A1616 (15.8/15.8 cm 3 /rev) Mounting F: Flange Mtg. Direction of Rotation R: Clockwise 1 (Normal) Outboard Pump 01 C 01 C Control Type 01: Pressure Compensator Type Pres. Adj. Range MPa B : 1.- 7 C : 1.-16 D : 1.-1 cm 3 /rev) B : 1.- 7 L: C : 1.-16 Foot H : 1.-1 Mtg. Inboard Pump (Driven End) S K -3 Control Type 01: Pressure Compensator Type Pres. Adj. Range MPa B : 1.- 7 C : 1.-16 D : 1.-1 A16 (15.8/. cm 3 /rev) B : 1.- 7 A (./. cm 3 /rev) A1637 (15.8/36.9 cm 3 /rev) A37 (./36.9 cm 3 /rev) A1656 (15.8/56. cm 3 /rev) A56 (./56. cm 3 /rev) A1670 (15.8/70.0 cm 3 /rev) A70 (./70.0 cm 3 /rev) A3770 (36./70.0 A1690 (15.8/91.0 cm 3 /rev) A90 (./91.0 cm 3 /rev) A3790 (36.9/91.0 cm 3 /rev) A5690 (56./91.0 cm 3 /rev) A16145 (15.8/145 cm 3 /rev) A145 (./145 cm 3 /rev) B : 1.- 7 C : 1.-16 B : 1.- 7 C : 1.-16 H : 1.-1 B : 1.- 7 C : 1.-16 B : 1.- 7 C : 1.-16 H : 1.-1 B : 1.- 7 C : 1.-16 B : 1.- 7 C : 1.-16 H : 1.-1 B : 1.- 7 C : 1.-16 B : 1.- 7 C : 1.-16 B : 1.- 7 C : 1.-16 H : 1.-1 B : 1.- 7 C : 1.-16 A37145 (36.9/145 cm 3 /rev) B : 1.- 7 A56145 (56./145 cm 3 /rev) ( Viewed from Shaft End ) C : 1.-16 H : 1.-1 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details. C : 1.-16 B : 1.- 7 C : 1.-16 D : 1.-1 B : 1.- 7 C : 1.5-16 H : 1.8-1 K :.0-8 Port Position of Outboard Pump S: Side Port None: Axial Port Shaft Extension K: Keyed Shaft None: Keyed Shaft Design Number 3 3 3 3 3 3 3 A Series Double Pumps, Pressure Compensator Type 111

A Series Piston Pumps Variable / Fixed Double Pumps Graphic Symbol M O Model Number Designation A1637 -F -R Series Number A16R1 AR1 Mounting Direction of Rotation Inboard Pump Outboard Pump (Driven End) 01 C -3 A A Control Type Pres. Adj. Range MPa B : 1.- 7 C : 1.-16 D : 1.-1 B : 1.- 7 C : 1.-16 Nominal Displacement cm 3 /rev Position Suction Port Position K -3 Shaft Extension K: Keyed Shaft A37R1 3 B : 1.- 7 6, 8 C : 1.-16 10, 1 D : 1.-1 A56R1 F: 14, 17 3 Flange 19, 3 Mtg. 5, 31 A70R1 ( Viewed from Shaft End ) 01: ( Viewed from Shaft End ) Pressure R: Compensator B : 1.- 7 Clockwise 1 Type C : 1.5-16 A90R1 A: Up A: Up L: (Normal) H : 1.8-1 Foot K :.0-8 A145R1 Mtg. A70R None: Keyed Shaft B : 1.- 7 41,47 C : 1.5-16 A90R 56,59 H : 1.8-1 65 K :.0-8 A145R 1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details. Design Number 3 3 Consult Yuken when detailed material such as dimensions figures is required. 11 A Series Piston Pumps Variable / Fixed Double Pumps