Experiment 1 Breadboard Basics

Similar documents
Digital Multimeter: This handheld device is used by this course to measure voltage and resistance we will not use this to measure current or capacitan

Laboratory 2 Electronics Engineering 1270

CHAPTER 2. Current and Voltage

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

In the first part of this series on

Mini Multimeter with Non-Contact Voltage Detector (NCV)

True RMS Autoranging Multimeter

Autoranging Multimeter

C capacitance, 91 capacitors, codes for, 283 coupling, polarized and nonpolarized,

2W, Low Cost DIP, Dual Output DC/DC Converters

LAB 7. SERIES AND PARALLEL RESISTORS

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

DIGITAL MULTIMETER INSTRUCTION MANUAL

Lab 4.4 Arduino Microcontroller, Resistors, and Simple Circuits

Building an Electric Circuit to Convert the Sensor Resistance into a Usable Voltage INSTRUCTIONS

Basic Electronics Course Part 1

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Digital Multimeter AHMAD FOUAD ALWAN

OPERATING INSTRUCTIONS

General Electrical Information

User's Guide. True RMS Multim eter. Extech 430

Autoranging Industrial Multimeter

Dawson DAN100. Analog Multimeter User s Manual

Basic Characteristics Data

90 Series - Socket overview for 60 series relays

Mini Multimeter with Non-Contact Voltage Detector (NCV)

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

Lab 2 Electrical Measurements and Ohm s Law

Lab Electronics Reference: Tips, Techniques, and Generally Useful Information for the Labs

Electronics Made Easy 1 Experimental Kit

Selectable Impedance Adapter

P08451 Prototype Thermoelectric Heat Exchanger

Model 125 Electrical Service Voltmeter

Table of Contents Title Page No.

Electronics Technology and Robotics I Week 2 Basic Electrical Meters and Ohm s Law

Ohm s Law. 1-Introduction: General Physics Laboratory (PHY119) Basic Electrical Concepts:

MODEL ELC-12/40-CVM-D BATTERY CHARGER

BREADBOARD PLUGIN POWER SUPPLY # REV3 +5VDC

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Lab #1: Electrical Measurements I Resistance

DECIDUOUS FILTER ASSEMBLY INSTRUCTIONS RECOMMENDED TOOL AND SUPPLY LIST DECIDUOUS FILTER KIT PARTS LIST

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

MODEL MAS BAR TO BAR TESTER INSTRUCTIONS

Series and Parallel Networks

HOW TO USE A MULTIMETER, PART 1: INTRODUCTION

DIY Synth Kit - Manual STUTTER SYNTH

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

5.2 PRE-OPERATION PROCEDURE WARRANTY

DE13 FM/MW/SW1, 2 WORLD RECEIVER WITH FLASHLIGHT, CRANKER DYNAMO & SOLAR POWER SUPPLY. Operation Manual PATENT NO.:

Model ½ Digit Multimeter

Handout Activity: HA061

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO

Reading on meter (set to ohms) when the leads are NOT touching

A device that measures the current in a circuit. It is always connected in SERIES to the device through which it is measuring current.

Digital Multimeter User's Manual

EXPERIMENT 4 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

ElPower script. Contents. ElPower script diagnostics of the engine starting and charging system

3-1/2 Digit LCD Multimeter with Tachometer Kit

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

THE ALT AL ERNA RN T A OR

Figure 1: (a) cables with alligator clips and (b) cables with banana plugs.

Summary of Specifications

PARTS AND SERVICE MANUAL FOR MERCO HOLDING CABINET MODEL MHC-22-TDL

A.W. SPERRY INSTRUMENTS INC.

DIY Synth Kit - Manual

PAGE Both power cords must be connected & powered to operate the E-TES 120.

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

MOTHMAN FUZZ ASSEMBLY INSTRUCTIONS RECOMMENDED TOOL AND SUPPLY LIST MOTHMAN FUZZ KIT PARTS LIST

User s Manual Rev 1.3 GME

Acceleration Sensor AS - 030

arxiv:submit/ [math.gm] 27 Mar 2018

Surface Mount Multilayer Ceramic Chip Capacitors for Non-Magnetic Applications (Epoxy Bonding)

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

Features. Isolation PFM. Block Diagram

TESTING & ELECTRONICS

ENGG1015: lab 5. A Taste of the Project

INTECH Micro 2300-RTD6

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

5 mm contact pin pitch PCB or 95 series sockets

Getting Started with the Digilent Electronics Explorer Board

MGV (Marshall TM Guv'nor TM Replica) Instructions

Chapter 3. ECE Tools and Concepts

Surface Mount Multilayer Ceramic Chip Capacitors for Non-Magnetic Applications (IR Reflow Soldering)

Lenze Gearmotor Product Warning (Verification of Ground Connectivity)

TROUBLESHOOTING AND MAINTAINING ELECTRONIC KILN CONTROL SYSTEMS

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Copper Bar... ASTM B187, B152 Silicon Bronze... ASTM F468, F467, F651

Faraday's Law of Induction

Using your Digital Multimeter

High Voltage Engineering

The above explanation leaves out a few details, which may frustrate a user. Here are some instructions with pictures to help you be successful.

Power Electronics Training System

CERTIFICATE OF ACCREDITATION

DELTA4000 Accessories

High Efficiency SiC Power Semiconductor. May 20, 2014 Toyota Motor Corporation

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

ESC Aluminum Electrolytic Capacitors

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

Transcription:

Experiment 1 Breadboard Basics

The goal of Experiment 1 is for you to identify on the breadboard of the ANDY board: which of the rows of pins are connected (shorted) together and which of the set of pins in columns are connected together so that you will be able to construct the circuits properly in the experiments that follow.

The breadboard on the ANDY board is the white section with the rows of pins. It is used to hold components and to allow easily wiring between the power supplies on the ANDY board to the components and from the component to component to form a circuit. The squarish holes are where wires or the legs of your components are inserted. Inside each hole is a set of leaf springs that clamp on to the wire or end of the component inserted into the hole.

This is the back surface of the breadboard, which one of the ECE lab staff removed from the board similar to the ANDY board. Some metal strips run horizontally and some run vertically. These strips create a low resistance connection between the sets of square holes along the metal strip to allow you to easily connect ends of components together without running wires between them. Wires are used to make jumpers between metal strips. Maximum frequency of operation is 4 MHz, due to parasitic capacitance

. Your job in Experiment 1 is to determine which set of holes in specific columns and rows are connected by these metal strips on the ANDY board.

An instrument that is used to measure: DC voltage and DC current AC voltage and AC current (RMS values) Resistance up to 200 MW Continuity Commonly used to determine polarity of diodes Capacitance at 20 khz Frequency of a sinusoidal voltage Low frequency h fe (or b) of a transistor Temperature Measured with thermocouple probe.

Change the battery in the multimeter. The current 9V battery was inserted when the multimeter was manufactured. The battery has about a 1 year shelf life. Errors in measurements can be greater than 10% when the battery voltage is low. This is greater than the measurement error allowed in the grading program. Failure to replace the battery with a new one may cause you to lose points on your post-validation report. There should be a new battery in your parts kit. Directions are available online at http://filebox.ece.vt.edu/~liab/equipment/dmm/changing_battery.pdf

Resistance measurements can be made directly using a digital multimeter (DMM). The probes are inserted into the V/W/T plug or jack (red probe) and the COM jack (black). Note that the dial on the meter is positioned at the 20k mark within the W measurement region.

The probes that come with the DMM have tips that are too large to fit into the holes on the ANDY board breadboard. Do not force them into the holes as this will damage the leaf springs within the holes. There are a set of banana jack probes in the probe kit that is offered by Electronix Express that have smaller tips, which you can use instead. Or you can use a small length of wire wrapped around each of the original probe tips that you then insert into the holes. Banana jacks

Set the dial to the maximum resistance value. When there is only air between the tips of the red and black probes, the reading on the DMM is in the overflow condition as air is an insulator and the resistance of air is greater than 200 MW. A 1 off to the left with no other digits displayed. When there is a very conducting material placed between the two tips, the measurement should be 0.00, indicating that the resistance of the material is much less than 200 MW. You should rotate the dial to a lower resistance range until you either reach the lowest range or an overflow condition is indicated. In the first case, you should record the measurement. In the latter case, you should set the range to the next highest setting and then record a measurement.

Follow the pattern described in the laboratory manual to map the position of the metal strips that connect sets of holes (pins) on the ANDY board breadboard. Should you find that the minimum resistance that you measure between pins that are connected by a metal strip is greater than 5 W, you may have a bad breadboard. Very rarely, the metal strips shift in position during shipment. Contact one of the the OpEL GTA immediately and show the GTA the measurement. If the GTA determines that you have a bad board, he will trade your old ANDY board for a new.