Switchgear Wires. Specifications: Page <1> 21/12/11 V1.1. Description : 16 mm 2 flex plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231

Similar documents
Mains Flex Oval/Round 2-3 Core

MC 5% Series. Construction. Power Rating and Dimension. Features: Page <1> 07/04/12 V1.1. Dimension. Width (W) ± Series. Height (H) ±0.

Pushbutton Switches Sub-Miniature

Festoon Series. Features: Applications: Festoon 37 mm, 3 LEDs. Specifications: Festoon 37 mm, 6 LEDs. Page <1> 26/03/12 V1.1

FG Series, 230V ac Toroidal Single Primary Transformers

GBPC15,25,35- Series. Features: Page <1> 10/08/10 V1.1

Stepper Motor Drive. Description: Specifications:

MC 1% Series Thick Film Chip Resistors

Thick Film Chip Resistors

Multi Layer Ceramic Capacitor

Wire Wound Chip Inductor Ferrite

Fast Acting Fuse SMD Thin Film

Slimline Axial Flow Fans 80mm 92mm 119mm

Prototyping and Soldering Kit UK

1 Moulded resin 2 Electrode (Ag) 3 Ferrite core 4 Magnet wire

High Power Chip Resistor

CB Series Tantalum Capacitors

Type Number Symbol Value Units

Surface Mount Thick Film Resistor MCWR Series

Automotive and Anti-Sulfuration Chip Resistor 0603

Blade Fuses - Illuminated Mini Blade

High Voltage Thick Film Chip Resistor MCHVR Series

Thick Film Chip Resistors

Thick Film Low Ohm Chip Resistors

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

6491B / H07Z-R / BS EN Cable

THE UK S BENCHMARK FOR TRI-RATED CABLE

N2XY IEC XLPE PVC 0.6/1kV Cable

SY PVC / BS EN Control Flexible Cable

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

3. Fire Resistant Cables

1 Conductor Class 5 flexible annealed plain copper conductor

Catalogue. Index INDUSTRIAL CABLE

Power & Control Cable IEC

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cable IEC

BFOU 0.6/1kV Power Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

Power & Control Cable IEC

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Firetec BS 7846 LPCB BASEC Approved Power Cable

RFOU 0.6/1kV Power Cable

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

o o blue-brown Fire Performance BS EN BS EN

LSZH Fire Resistant Cables

600/1000V, PVC Insulated Cables according to IEC

buildings. They are also used for industrial electrification regular intervals along with the size of the wire.

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

FR-3S Fire Resistant Cables

FLEX-O-POWER FLEXIBLE WELDING

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Data sheet chainflex CF885.PE

Aluminum Capacitors Standard C Snap-In

Building & Infrastructure Cables DELIVERING ENERGY

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

Process description Johnson Matthey s DAVY methanation system comprises a series of reaction vessels charged with our CRG catalysts.

Power & Control Cables. U o. /U 0.6/1 kv - IEC

DURAREEL TRAILING REELING CABLE

Process description Esterification proceeds by a simple, continuous process in a reactive distillation column.

Aluminum Capacitors Standard - 85 C Snap-In

Data sheet chainflex CF886

Technologies & Economics

Your Partner in Safe Power Solutions. About RESCAB

H05 V-K PVC-Single Cores, fine wire stranded

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Data sheet chainflex CF8821

flame Retardant overall screened Instrumentation cables (Multicore)

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Data sheet chainflex CF881

FLAME RETARDANT CONTROL CABLE. Application Standard. - Design guide : JIS C 3410(2010) - Flameretardant : IEC

R A, 80V Microstepping Driver The PowerHouse

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Engineers Tables SI Units

0.6 / 1kV Afumex Flex Cable. The greater the flow of people, the better the protection should be.

The cables you need when you need them

Calculation of the Cross-sectional Areas of Circuit Live Conductors

Klea 410A Engineers Tables SI Units

Data sheet chainflex CFSOFT1

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

600/1000V, XLPE Insulated Cables according to IEC

Data sheet chainflex CF886

Unarmoured Single-Core Cables to BS6883

BS6724 SWA/LSZH Cable IEC /1000V

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Power Panel 6 W Potentiometer

Controlflex Cables Controlflex Cables

CONTROL CABLES CABLES FZE.

Technical Data Sheet Shielded (CY) PVC Control Cable

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

3M Mechanical Shearbolt Connectors, QCI Series

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

LOW VOLTAGE c a b l e s

Transcription:

Description : 16 mm 2 flex plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 16 mm 2 (approximate 126 / 0.4 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 1.21 Ω/km : Minimum insulation resistance at 70 C : 0.0048 MΩ km : Minimum average radial thickness : 1 mm : Minimum overall diameter : 6.7 mm : Minimum overall diameter : 9 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 105 A : Approximate mass / unit length : 182 kg/km Page <1> 21/12/11 V1.1

Description : 25 mm 2 flex plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 25 mm 2 (approximate 196/0.4 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 0.78 Ω/km : Minimum insulation resistance at 70 C : 0.0047 MΩ km : Minimum average radial thickness : 1.2 mm : Minimum overall diameter : 8.4 mm : Minimum overall diameter : 11.5 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 141 A : Approximate mass / unit length : 292 kg/km Page <2> 21/12/11 V1.1

Description : 1.5 mm 2 (30/0.25 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 1.5 mm 2 (30/0.25 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 13.3 Ω/km : Minimum insulation resistance at 70 C : 0.0111 MΩ km : Minimum average radial thickness : 0.8 mm : Minimum overall diameter : 3 mm : Minimum overall diameter : 3.6 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 24 A : Approximate mass / unit length : 22 kg/km Page <3> 21/12/11 V1.1

Description :1 mm 2 (32/0.2 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 1 mm 2 (32/0.2 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 19.5 Ω/km : Minimum insulation resistance at 70 C : 0.0128 MΩ km : Minimum average radial thickness : 0.8 mm : Minimum overall diameter : 2.7 mm : Minimum overall diameter : 3.3 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 19 A : Approximate mass / unit length : 16 kg/km Page <4> 21/12/11 V1.1

Description : 2.5 mm 2 (50/0.25 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 2.5 mm 2 (50/0.25 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 7.98 Ω/km : Minimum insulation resistance at 70 C : 0.0094 MΩ km : Minimum average radial thickness : 0.8 mm : Minimum overall diameter : 3.4 mm : Minimum overall diameter : 4.1 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 32 A : Approximate mass / unit length : 32 kg/km Page <5> 21/12/11 V1.1

Description :4 mm 2 (56/0.3 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 4 mm 2 (56/0.3 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 4.95 Ω/km : Minimum insulation resistance at 70 C : 0.0077 MΩ km : Minimum average radial thickness : 0.8 mm : Minimum overall diameter : 3.9 mm : Minimum overall diameter : 4.8 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 43 A : Approximate mass / unit length : 49 kg/km Page <6> 21/12/11 V1.1

Description : 10 mm 2 (80/0.4 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 10 mm 2 (80/0.4 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 1.91 Ω/km : Minimum insulation resistance at 70 C : 0.0058 MΩ km : Minimum average radial thickness : 1 mm : Minimum overall diameter : 5.7 mm : Minimum overall diameter : 7.2 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 79 A : Approximate mass / unit length : 114 kg/km Page <7> 21/12/11 V1.1

Description :6 mm 2 (84/0.3 mm) plain copper, PVC insulated, 600 / 1,000 V, type BK, BS 6231 Conductors* : 6 mm 2 (84/0.3 mm) plain annealed copper bunch meeting the requirements of BS 6360, class 5 : Maximum resistance at 20 C : 3.3 Ω/km : Minimum insulation resistance at 70 C : 0.0059 MΩ km : Minimum average radial thickness : 0.8 mm : Minimum overall diameter : 4.4 mm : Minimum overall diameter : 5.3 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 56 A : Approximate mass / unit length : 73.5 kg/km Page <8> 21/12/11 V1.1

Description : Single core, 35 mm 2 flexible plain copper, PVC insulated, 600 / 1,000 BS 6231, type BK Conductors* : 35 mm 2 (276/0.4 PC) plain annealed copper wires to BS 6360, class 5 : Maximum resistance of conductors at 20 C : 0.554 Ω/km Insulation : Type TI 1 PVC compound to BS EN 50363-3 : Insulation must be circular, smooth and not have air bubbles caused by overheating during extrusion : Minimum point radial thickness : 0.98 mm : Minimum average radial thickness : 1.2 mm : Minimum overall diameter : 10.7 mm : Minimum overall diameter : 11.3 mm : Maximum current rating at 30 C ambient temperature (free air, single cable) : 19 A : Approximate mass / unit length : 16 kg/km and maximum resistance as set in BS specification) Page <9> 21/12/11 V1.1

Part Number Table Description Part Number Description Part Number Wire, BK, Black, 32/0.2 mm, 100 m BK 1.0 BLK 100M Wire, BK, Black, 126/0.4 mm, 50 m BK 16.0 BLK 50M Wire, BK, Red, 32/0.2 mm, 100 m BK 1.0 RED 100M Wire, BK, Red, 126/0.4 mm, 50 m BK 16.0 RED 50M Wire, CK, Black, 30/0.25 mm, 100 m CK 1.5 BLK 100M Wire, BK, GRN/YEL, 126/0.4 mm, 50 m BK 16.0 G/Y 50M Wire, CK, Blue, 30/0.25 mm, 100 m CK 1.5 BLU 100M Wire, BK, Black, 196/0.4 mm, 50 m BK 25.0 BLK 50M Wire, CK, Red, 30/0.25 mm, 100 m CK 1.5 RED 100M Wire, BK, Red, 196/0.4 mm, 50 m BK 25.0 RED 50M Wire, CK, GRN/YEL, 30/0.25 mm, 100 m CK 1.5 G/Y 100M Wire, BK, Black, 276/0.4 mm, 50 m BK 35.0 BLK 50M Wire, CK, Black, 50/0.25 mm, 100 m Wire, CK, Blue, 50/0.25 mm, 100 m Wire, CK, Red, 50/0.25 mm, 100 m Wire, CK, GRN/YEL, 50/0.25 mm, 100 m Wire, BK, Black, 30/0.25 mm, 100 m Wire, BK, Green, 30/0.25 mm, 100 m Wire, BK, Red, 30/0.25 mm, 100 m Wire, BK, GRN/YEL, 30/0.25 mm, 100 m Wire, BK, Black, 50/0.25 mm, 100 m Wire, BK, Blue, 50/0.25 mm, 100 m Wire, BK, Red, 50/0.25 mm, 100 m Wire, BK, GRN/YEL, 50/0.25 mm, 100 m Wire, BK, Black, 56/0.3 mm, 100 m Wire, BK, Red, 56/0.3 mm, 100 m Wire, BK, GRN/YEL, 56/0.3 mm, 100 m Wire, BK, Black, 84/0.3 mm, 100 m Wire, BK, Blue, 84/0.3 mm, 100 m Wire, BK, Red, 84/0.3 mm, 100 m Wire, BK, GRN/YEL, 84/0.3 mm, 100 m Wire, BK, Black, 80/0.4 mm, 100 m Wire, BK, Red, 80/0.4 mm, 100 m Wire, BK, GRN/YEL, 80/0.4 mm, 100 m CK 2.5 BLK 100M CK 2.5 BLU 100M CK 2.5 RED 100M CK 2.5 G/Y 100M BK 1.5 BLK 100M BK 1.5 GRN 100M BK 1.5 RED 100M BK 1.5 G/Y 100M BK 2.5 BLK 100M BK 2.5 BLU 100M BK 2.5 RED 100M BK 2.5 G/Y 100M BK 4.0 BLK 100M BK 4.0 RED 100M BK 4.0 G/Y 100M BK 6.0 BLK 100M BK 6.0 BLU 100M BK 6.0 RED 100M BK 6.0 G/Y 100M BK 10.0 BLK 100M BK 10.0 RED 100M BK 10.0 G/Y 100M Wire, BK, BS6231, Black, 6 mm, 25 m 1179195 Wire, BK, BS6231, Blue, 6 mm, 25 m 1179197 Wire, BK, BS6231, Red, 6 mm, 25 m 1179198 Wire, BK, BS6231, Yellow, 6 mm, 25 m 1179199 Wire, BK, BS6231, GRN/YEL, 6 mm, 25 m 1179200 Wire, BK, BS6231, Black, 10 mm, 25 m 1179201 Wire, BK, BS6231, Red, 10 mm, 25 m 1179204 Wire, BK, BS6231, Yellow, 10 mm, 25 m 1179205 Wire, BK, BS6231, Black, 16 mm, 25 m 1179207 Wire, BK, BS6231, Red, 16 mm, 25 m 1179209 Wire, BK, BS6231, Yellow, 16 mm, 25 m 1179210 Wire, BK, BS6231, Black, 25 mm, 25 m 1179212 Wire, BK, BS6231, Blue, 25 mm, 25 m 1179213 Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Pro-POWER is the registered trademark of the Group. Premier Farnell plc 2011. Page <10> 21/12/11 V1.1