Controlflex Cables Controlflex Cables
|
|
- Emmeline Austin
- 6 years ago
- Views:
Transcription
1 YY Type Cable : CY Type Cable : YCY-JZ Transparent PVC Sheath : SY Type Cable :1 YY-LSF Type Cables :1 CY-LSF Type Cables :1 Technical Information - Current Ratings :1 Technical Information - Voltage Drop :
2 1 Controlflex YY Type PVC Insulated Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Details on dynamic types available on request. 1 1 Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) copper conductors to BS EN 0, Plain. Insulation: PVC insulation TI. to BS EN 0-, Type YI. to DIN VDE 00 Pt. Core Identification: Cores will be number printed, in a contrasting colour, on black PVC insulation. All cables of three core and above will incorporate a green/yellow earth core in the outer layer. Grey PVC sheath Type TM. to BS EN 0--1, Type YM. to DIN VDE 00 Pt. Flame retardant to BS EN 0-1- & IEC 0-1. Voltage Rating: 00/00V. Temperature Rating: 0 C maximum conductor operating temperature Add suffix - KL to part number for cables up to core having coloured cores, or - HKL for and core cables as follows: e.g. AAE-C00-KL or AAE-C00-HKL core-blue, brown core-green/yellow, blue, brown core-green/yellow, brown, black, grey core-green/yellow, brown, black, grey, blue For further technical information refer to the end of the section. For Low Smoke Zero Halogen versions, refer to page : Controlflex is a registered trademark of Anixter Inc. 0
3 Anixter Number Number of Cores Nominal Conductor Continued overleaf... mm #/mm mm kg/km AAC-C /0.0. AAC-C /0.0.1 AAC-C /0.0. AAC-C /0.0. AAC-C / AAC-C0 0. 1/0.0. AAC-C / AAC-C /0.0.1 AAC-C / AAC-C0 0. 1/ AAC-C / AAD-C00 0. /0.0.1 AAD-C00 0. / AAD-C00 0. / AAD-C00 0. /0.0. AAD-C00 0. / AAD-C00 0. / AAD-C00 0. / AAD-C0 0. / AAD-C /0.0. AAD-C /0.0.1 AAD-C / AAD-C0 0. / AAD-C0 0. / AAD-C0 0. / AAD-C / AAE-C00 1 /0.0. AAE-C00 1 / AAE-C00 1 /0.0. AAE-C00 1 /0.0. AAE-C00 1 /0.0. AAE-C0 1 /0.0. AAE-C / AAE-C /0.0. AAE-C / AAE-C0 1 /0.0. AAE-C0 1 / Controlflex YY Type PVC Insulated Flexible Cable 00/00V 0 C
4 1 Controlflex YY Type PVC Insulated Flexible Cable 00/00V 0 C (continued) Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km AAE-C / AAE-C0 1 / AAF-C /0.. 1 AAF-C /0.. AAF-C /0.. AAF-C /0.. AAF-C /0..0 AAF-C /0.. 1 AAF-C0 1. 0/0.. AAF-C /0.. AAF-C0 1. 0/ AAF-C /0. 1. AAF-C /0.. 0 AAF-C0 1. 0/ AAF-C0 1. 0/ AAF-C0 1. 0/0. 1. AAF-C0 1. 0/0. 0. AAF-C /0.. AAF-C /0.. 1 AAG-C00. 0/0.. AAG-C00. 0/0.. AAG-C00. 0/0.. AAG-C00. 0/0.. AAG-C00. 0/0..1 AAG-C /0. 1. AAG-C / AAG-C / AAG-C / AAG-C0. 0/0. 0. ABC-C00 / ABC-C00 / ABC-C00 /0.0. ABC-C00 /
5 Anixter Number Number of Cores Nominal Conductor Controlflex YY Type PVC Insulated Flexible Cable 00/00V 0 C (continued) 1 mm #/mm mm kg/km AAGA-C00 / AAGA-C00 / AAGA-C00 / AAGB-C00 0/ AAGB-C00 0/ AAGC-C00 1 1/ AAGC-C00 1 1/ AAGD-C00 1/ AAGD-C00 1/ AAGE-C00 / AAGE-C00 / AAGF-C00 0 / AAGF-C00 0 / AAGG-C00 0 0/ AAGG-C00 0 0/ AAGH-C00 / AAGH-C00 /0.0. Add suffix - KL to part number for cables up to three core having coloured cores or -HKL for four and five core cables as follows: e.g. AAD-C00-KL or AAD-C00-HKL. core - blue, brown. core - green/yellow, blue, brown. core - green/yellow, brown, black, grey. core - green/yellow, brown, black, grey, blue. For F compliant meeting NBN C0-00 (IEC 0-- Cat. C) add suffix -F e.g. AAF-C00-F. For further technical information refer to the end of the section. For Low Smoke Zero Halogen versions up to and including five core refer to page :
6 1 Controlflex CY Type PVC Insulated, Screened Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Incorporates a collective tinned copper wire braid screen for electrical protection. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Details on dynamic types available on request. 1 1 Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) copper conductors to BS EN 0, plain. Insulation: PVC insulation TI. to BS EN 0-, Type YI. to DIN VDE 00 Pt. Core Identification: Cores will be number printed, in a contrasting colour, on black PVC insulation. All cables of three core and above will incorporate a green/yellow earth core in the outer layer. Binder Tape: p.e.t.p. tape. Tinned copper wire braid. Minimum coverage 0%. Grey PVC sheath Type TM. to BS EN 0--1, Type YM. to DIN VDE 00 Pt.RAL 000. Flame retardant to BS EN 0-1- & IEC 0-1 Voltage Rating: 00/00V. Temperature Rating: 0 C maximum conductor operating temperature Add suffix - KL to part number for cables up to core having coloured cores, or - HKL for and core cables as follows: e.g. AAN-C00-KL or AAN-C00-HKL core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue For further technical information refer to the end of the section. For Low Smoke Halogen versions refer to page :1. 1 Controlflex is a registered trademark of Anixter Inc. 0
7 Anixter Number Number of Cores Nominal Conductor Controlflex CY Type PVC Insulated, Screened Flexible Cable 00/00V 0 C 1 mm #/mm mm kg/km AAK-C /0.0. AAK-C /0.0. AAK-C /0.0. AAK-C /0.0. AAK-C /0.0. AAK-C0 0. 1/0.0. AAK-C / AAK-C / AAK-C / AAK-C0 0. 1/ AAL-C00 0. /0.0.0 AAL-C00 0. /0.0. AAL-C00 0. /0.0. AAL-C00 0. / AAL-C00 0. /0.0. AAL-C00 0. /0.0. AAL-C0 0. /0.0. AAL-C / AAL-C / AAL-C /0.0.1 AAL-C0 0. / AAL-C0 0. / AAL-C / AAM-C00 1 / AAM-C00 1 /0.0. AAM-C00 1 /0.0.0 AAM-C00 1 /0.0. AAM-C00 1 / AAM-C0 1 / AAM-C / AAM-C / AAM-C / AAM-C0 1 /0.0. AAM-C / AAM-C0 1 / Continued overleaf
8 1 Controlflex CY Type PVC Insulated, Screened Flexible Cable 00/00V 0 C (continued) Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km AAN-C /0.. 0 AAN-C /0.. 0 AAN-C /0.. AAN-C /0.. 1 AAN-C /0.. AAN-C0 1. 0/0.. 0 AAN-C /0.. AAN-C / AAN-C / AAN-C0 1. 0/ AAN-C / AAN-C0 1. 0/ AAO-C00. 0/0..0 AAO-C00. 0/0.. 0 AAO-C00. 0/0.. 1 AAO-C00. 0/ AAO-C00. 0/0.. AAO-C /0.. AAOA-C00 /0.0.1 AAOA-C00 / AAOB-C00 / AAOB-C00 / AAOC-C00 0/ AAOC-C00 0/
9 Anixter Number Number of Cores Nominal Conductor Controlflex CY Type PVC Insulated, Screened Flexible Cable 00/00V 0 C 1 mm #/mm mm kg/km AAOD-C00 1 1/ AAOD-C00 1 1/ AAOE-C00 1/ AAOE-C00 1/ AAOF-C00 / AAOF-C00 / Add suffix - KL to part number for cables up to three core having coloured cores or -HKL for four and five core cables as follows: e.g. AAN-C00-KL or AAN-C00-HKL. core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue For F compliant meeting NBN C0-00 (IEC0-- Cat. C) add suffix -F e.g. AAN-C00-F For further technical information, refer to end of section. For Low Smoke Zero Halogen versions up to and including five core refer to page
10 1 Controlflex YCY-JZ Transparent PVC Sheath PVC Insulated, PVC inner bedding, tinned copper wire screened, PVC transparent sheath 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Incorporates a collective tinned copper wire braid screen for electrical protection and inner PVC bedding for better mechanical protection. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Details on dynamic types available on request 1 1 Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) copper conductors to BS EN 0. Insulation: PVC insulation TI. to BS EN 0-, Type YI. to DIN VDE 00 Pt. Core Identification: cores will be number printed, in a contrasting colour, on black PVC insulation. All cables of three core and above will incorporate a green/yellow earth core in the outer layer. PVC inner bedding in grey. Tinned copper wire braid screen 0% coverage. Transparent PVC sheath Type TM. to BS EN 0--1, Type YM. to DIN VDE 00 Pt. Flame retardant to BS EN 0-1- & IEC 0-1. Voltage Rating: 00/00V. Temperature Rating: flexible - C to +0 C, static -0 C to + 0 C Controlflex is a registered trademark of Anixter Inc. 0
11 Controlflex YCY-JZ Transparent PVC Sheath PVC Insulated, PVC inner bedding, tinned copper wire screened, PVC transparent sheath 00/00V 0 C Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km AAM-C / AAM-C /0.0.1 AAM-C /0.0. AAM-C /0.0. AAM-C /0.0. AAM-C / AAN-C /0.. AAN-C / AAN-C /0.. AAN-C /0.. 1 AAN-C /0. 1. AAN-C /0. 1. AAO-C /0.. 1 AAO-C / AAO-C /0.. 1 AAO-C /0. 1. AAO-C / AAOA-C / AAOA-C / AAOA-C / AAOB-C /0.0.0 AAOB-C /
12 1 Controlflex SY Type PVC Insulated, GSWB, Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Incorporates steel wire braid screen for additional mechanical protection. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Details on dynamic types available on request. 1 1 Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) copper conductors to BS EN 0, plain. Insulation: PVC insulation TI. to BS EN 0-, Type YI. to DIN VDE 00 Pt. Core Identification: Cores will be number printed, in a contrasting colour, on black PVC insulation. All cables of three core and above will incorporate a green/yellow earth core in the outer layer. Inner Sheath: PVC inner sheath Type TM. to BS EN 0--1, Type YM. to DIN VDE 00 Pt. Galvanised steel wire braid (minimum coverage 0%). Outer Sheath: Transparent PVC outer sheath. Flame retardant to BS EN 0-1- & IEC0-1. Voltage Rating: 00/00V. Temperature Rating: 0 C maximum conductor operating temperature Add suffix - KL to part number for cables up to core having coloured cores, or - HKL for and core cables as follows: e.g. AAT-C00-KL or AAT-C00-HKL core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue For further technical information refer to the end of the section. The number and size of wires #/mm are nominal and may be changed dependent on supply. Controlflex is a registered trademark of Anixter Inc. 0 1
13 CONTROLFLEX "SY" TYPE Controlflex SY Type PVC Insulated, GSWB, Flexible Cable 00/00V 0 C 1 Anixter Number Number of Cores Nominal Conductor Continued overleaf... mm #/mm mm kg/km AAQ-C /0.0. AAQ-C /0.0. AAQ-C /0.0. AAQ-C / AAQ-C /0.0. AAQ-C / AAQ-C /0.0. AAR-C00 0. /0.0. AAR-C00 0. /0.0. AAR-C00 0. /0.0. AAR-C00 0. / AAR-C00 0. / AAR-C / AAR-C0 0. / AAR-C / AAR-C0 0. / AAS-C00 1 /0.0. AAS-C00 1 / AAS-C00 1 /0.0. AAS-C00 1 /0.0.1 AAS-C00 1 /0.0. AAS-C0 1 / AAS-C / AAS-C / AAS-C /
14 1 Controlflex SY Type PVC Insulated, GSWB, Flexible Cable 00/00V 0 C (continued) Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km AAS-C0 1 / AAS-C0 1 / AAT-C /0.. AAT-C /0.. AAT-C /0.. 1 AAT-C /0.. AAT-C /0.. 1 AAT-C /0. 1. AAT-C /0. 1. AAT-C0 1. 0/ AAT-C0 1. 0/0. 1. AAU-C00. 0/0.. AAU-C00. 0/0.. 1 AAU-C00. 0/ AAU-C00. 0/0.. AAU-C00. 0/0. 1. AAU-C / AAU-C /0. 1. AAU-C0. 0/0.. 1 AAV-C00 / AAV-C00 / AAV-C00 / AAV-C00 / Continued overleaf... 0
15 Anixter Number Number of Cores Nominal Conductor Controlflex SY Type PVC Insulated, GSWB, Flexible Cable 00/00V 0 C (continued) mm #/mm mm kg/km AAW-C00 /0.0. AAW-C00 / AAX-C00 0/ AAX-C00 0/ AAX-C00 0/ AAY-C00 1 1/ AAY-C00 1 1/ AAY-C00 1 1/ AAZ-C00 1/ AAZ-C00 1/ AAZ-C00 1/0.0. AEA-C00 / AEA-C00 / Add suffix - KL to part number for cables up to three core having coloured cores or -HKL for four and five core cables as follows: e.g. AAT-C00-KL or AAT-C00-HKL. core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue For F compliant meeting NBN C0-00 (IEC0-- Cat. C) add suffix -F e.g. AAN-C00-F For further technical information, refer to the end of the section
16 1 Controlflex YY-LSF Type Low Smoke Zero Halogen Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. 1 1 Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) copper conductors to BS EN 0. Insulation: Zero halogen insulation. Core Identification: Cores will be number printed, in a contrasting colour, on black low smoke zero halogen insulation. All cables of three core and above will incorporate a green/yellow earthcore in the outer layer. Grey LSF outer sheath Type LTS to BS Section.1. RAL 000. Flame retardant to BS EN Meets IEC m cube smoke emission test. Voltage Rating: 00/00V. Temperature Rating: 0 C maximum conductor operating temperature Add suffix - KL to part number for cables up to core having coloured cores, or - HKL for and core cables as follows: e.g. ALE-C00-KL or ALE-C00-HKL core - blue, brown core - green/yellow, blue, brown core - green/yellow, brown, black, grey core - green/yellow, brown, black, grey, blue For further technical information refer to the end of the section. Controlflex is a registered trademark of Anixter Inc. 0 1
17 Anixter Number Number of Cores Nominal Conductor Controlflex YY-LSF Type Low Smoke Zero Halogen Flexible Cable 00/00V 0 C 1 mm #/mm mm kg/km ALC-C /0.0. ALC-C / ALC-C /0.0. ALC-C /0.0. ALD-C00 0. / ALD-C00 0. / ALD-C00 0. / ALD-C00 0. /0.0. ALE-C / ALE-C / ALE-C /0.0.0 ALE-C /0.0. ALF-C /0.. ALF-C / ALF-C /0..1 ALF-C /0.. ALG-C00. 0/0.. ALG-C00. 0/0.. 1 ALG-C00. 0/0.. 1 ALG-C00. 0/0.. 1 Larger core counts and cables having coloured cores also available
18 1 Controlflex CY-LSF Type Low Smoke Zero Halogen Screened Flexible Cable 00/00V 0 C Application These flexible cables are designed for industrial control and instrumentation circuits and interconnections between mobile and fixed equipment. Incorporates a collective tinned copper wire braid screen for electrical protection. Cables are not recommended for applications where cable is likely to be subjected to repetitive flexing and/or twisting e.g. robotics, reeling drum, cranes etc. Especially for use in areas where fire would create dense smoke and toxic fumes causing a major threat to life and equipment. Specifications Generally in accordance with BS00 and VDE00. Conductors: Flexible (Class ) plain copper conductors to BS EN 0. Insulation: Zero halogen insulation. Core Identification: Cores will be number printed, in a contrasting colour, on black low smoke zero halogen insulation. All cables of three core and above will incorporate a green/yellow earthcore in the outer layer. Binder Tape: p.e.t.p. tape. Tinned copper wire braid (minimum 0% coverage). Grey LSF outer sheath Type LTS to BS section.1. RAL 000. Flame retardant to BS EN Meets IEC m cube smoke emission test. Voltage Rating: 00/00V. Temperature Rating: 0 C maximum conductor operating temperature. Add suffix -KL to part number for cables up to core having coloured cores, or -HKL for and core cables as follows: e.g. ALN-C00-KL or ALN-C00-HKL. core - blue, brown. core - green/yellow, blue, brown. core - green/yellow, brown, black, grey. core - green/yellow, brown, black, grey, blue. 1 For further technical information refer to the end of the section. 1 Controlflex is a registered trademark of Anixter Inc. 0 1
19 Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km ALK-C /0.0. ALK-C /0.0. ALK-C /0.0. ALK-C /0.0. ALL-C00 0. /0.0. ALL-C00 0. /0.0.1 ALL-C00 0. / ALL-C00 0. /0.0.0 ALM-C / ALM-C /0.0. ALM-C / ALM-C /0.0. ALN-C /0.. ALN-C /0.. ALN-C /0.. 1 ALN-C /0..1 ALO-C00. 0/0.. ALO-C00. 0/0..1 ALO-C00. 0/0.. 1 ALO-C00. 0/0.. 1 ALOA-C00 / ALOA-C00 /0.0. Continued overleaf... Controlflex CY-LSF Type Low Smoke Zero Halogen Screened Flexible Cable 00/00V 0 C
20 1 Controlflex CY-LSF Type Low Smoke Zero Halogen Screened Flexible Cable 00/00V 0 C (continued) Anixter Number Number of Cores Nominal Conductor mm #/mm mm kg/km ALOB-C00 /0.0. ALOB-C00 / ALOC-C00 0/0.0. ALOC-C00 0/ ALOD-C00 1 1/ ALOD-C00 1 1/0.0.0 Larger core counts and cables having coloured cores also available
21 Technical Information for Controlflex 1 CURRENT RATINGS 0 C ambient air temperature Nominal Conductor Area Current Ratings Single Phase a.c. or d.c. Three Phase a.c. mm A A The above ratings are based on cable in FREE air, in an ambient air temperature of 0 C. For ambient air temperatures other than 0 C the following rating factors should be applied: Ratings for cables up to and including mm are based on 0 C conductor operating temperature with mm and above based on 0 C operating temperature. Cables up to and including mm (Assuming 0 C conductor temperature) Ambient air temp C 0 0 Rating factor Cables mm and above (Assuming 0 C conductor temperature) Ambient air temp C Rating factor
22 Technical Information for Controlflex VOLTAGE DROP 0 C* conductor operating temperature Nominal Conductor Area Voltage Drop Single Phase a.c. or d.c. Three Phase a.c. mm mv/a/m mv/a/m r x z r x z Since cables may be used at conductor operating temperatures up to 0 C, the current ratings may be increased by the following factors: Cable up to and including mm x 1. cables above mm x 1.. Ambient temperature correction factors for cables operating at 0 C conductor temperatures should be applied as follows. Ambient air temp C Rating factor For cables where four or more cores are loaded, the following rating factors should be applied: No. of cores loaded Rating factor These factors need not be applied if the number of cores loaded does not exceed the square root of the total number of cores in the cable. 1 0
SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath
Applications Control cables in tool machinery, plant installation, power stations and data equipment. The braided screen of the galvanized steel wires offers the best possible protection against mechanical
More informationSY PVC / BS EN Control Flexible Cable
SY PVC / BS EN 50525-2-51 Control Flexible Cable Eland Product Group: A5J APPLICATION Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing
More information600/1000V, PVC Insulated Cables according to IEC
8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)
More informationHIGH TEMPERATURE CABLES
HIGH TEMPERATURE CABLES C O N T E N T S DEF 61-12 Part 18 Type 1 LFH Equipment Wires :2 Technical Information for DEF 61-12 :8 PTFE Insulated Equipment Wire Single Core :10 PTFE EFGLAS Aircraft Cable :12
More informationBS 6724 Armoured Power Cables, 600/1000V
BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The
More information600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH
More informationSPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI
1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
Technical Data Sheet Unshielded (YY) PVC Control Cable MachFlex 350 YY VDE Registered Flexible PVC Control Cables Applications Designed for applications which are installed in occasional flexing and fixed
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities
Shielded data cable with colour code according to DIN 47100 - shielded PVC data cable with colour code DIN 47100 for use in machinery and apparatus construction and in measurement, control and regulation
More informationÖLFLEX CLASSIC 110 CY
Screened PVC control cable with transparent outer sheath - PVC control cable, VDE registered, screened, flexible and numbered for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationÖLFLEX CLASSIC 115 CY
Screened PVC control cable with small outer diameter - PVC control cable, screened and flexible for various applications, thin and light without inner sheath, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr
More informationTechnical Data Sheet Shielded (CY) PVC Control Cable
MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include
More informationFlame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)
Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY
More informationVDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications
VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications - PVC control cable, VDE registered, oil resistant, flexible and UV-resistant for various applications,
More informationPRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities
Screened data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN 47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant Screened, Instrumentation
More informationSY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8
SY Cable Application: Measuring and control cable to connect equipment in production lines / assembly lines and conveyor systems. Can be used both fixed and flexible installations. Techincal Data: 1 Plain
More informationflame Retardant overall screened Instrumentation cables (Multicore)
Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer
More informationThe cables you need when you need them
The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you
More informationTechnical Data Sheet Unshielded (YY) PVC Control Cable
MachineTuff Cables Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include precision control sensors, multi axis control machines,
More informationCRANE, CONVEYOR, LIFT & REELING CABLES
CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264
More informationFlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E
Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationInsulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black
-I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed
More informationFlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable
Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating
More informationis the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.
is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for
More informationChemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations
More information600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)
600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power
More information600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC
MachineTuff Cables Low Voltage Control & Power Cable Galvanized Steel Wire Braid Armored (GSWB) > Excellent Mechanical Protection Applications Designed for applications which are installed in occasional
More informationBS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable
ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with
More informationData sheet chainflex CF240
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Aluminum/Polyester tape and extremely bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic foil 4.
More informationPRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved
Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info
More informationPower & Control Cable IEC
(2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationFlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable
Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V
More informationPVC SHEATH FLAME RETARDANT CABLE TO IEC60332
600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit
More information600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)
www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V
More informationSingle Core Cables 51
Single Core Cables 51 Single Core Cables PVC PVC Single Core Cables H05V-K /H07V-K Conductors: Flexible copper (class 5) Insulation: PVC Standards: HAR CENELEC Fire Performance: Flame retardant to IEC
More informationÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V
PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:
More informationData sheet chainflex CF6
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Extremely bending-stable braid made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture
More informationData sheet chainflex CF8821
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE
More informationBS6724 SWA/LSZH Cable IEC /1000V
BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationo o blue-brown Fire Performance BS EN BS EN
Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).
More informationBS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)
LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density
More informationN2XY IEC XLPE PVC 0.6/1kV Cable
N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to
More informationwww. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL
Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications
More informationÖLFLEX CLASSIC 110 H Info Benefits
Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article
More informationData sheet chainflex CF886
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Conductor
More informationFiretec BS 7846 LPCB BASEC Approved Power Cable
Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm
More informationBFOU 0.6/1kV Power Cable
BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency
More informationData sheet chainflex CF140.UL
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling PVC mixture 4. CFRIP: Tear strip
More informationMaterials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)
XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test
More informationConductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5
Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationData sheet chainflex CF881
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Banding: Plastic foil 4. Core insulation: Mechanically high-quality PVC mixture 5. Conductor: Stranded
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION fire protection halogen-free flexibility oil resistance These are the characteristics united
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationVDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements
VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,
More informationH07RN-F TITANEX (industrial flexible)
Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has
More informationUnarmoured Single-Core Cables to BS6883
Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units
More informationData sheet chainflex CF10
1. Outer jacket: Pressure extruded, halogen-free TPE mixture 2. Overall shield: Extremely bending-resistant braiding made of tinned copper wires 3. Inner jacket: Pressure extruded, gusset-filling TPE mixture
More information(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable
()SSHÖU O/J, ()SSHÖU 3E, ()SSHÖU 3E + ST 0.6/1kV Cable Eland Product Group: A7JS APPLICATIO Heavy duty tough rubber flexible cable with or without individually earth screened cores for dynamic or static
More informationH05 V-K PVC-Single Cores, fine wire stranded
H05 VK PVCSingle Cores, fine wire stranded Technical data PVC single cores to DINVDE0283 H05 VK/H05 VU to DINVDE028 part3, HD2.3S3 and IEC02273 Temperature range flexing 5 C to +70 C fixed installation
More informationCaledonian Fire Resistant Optic Fiber Cables
Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They
More informationTelephone Cables Fire Warning Cables
Telephone Cables Fire Warning Cables Telephone Cables Fire Warning Cables As supplier of underground cables, telephone cables for indoor and outdoor lying, as well as fire warning cables (also the halogen-free
More informationCatalogue. Index INDUSTRIAL CABLE
Catalogue INDUSTRIAL CABLE 1. BARE COPPER EARTH WIRE 2. GENERAL PURPOSE HOUSE WIRE 3. SURFIX CABLE 4. FLAT TWIN & EARTH CABLE 5. CABTYRE CABLE 6. TWIN ILLUMINATION CABLE 7. SINGLE CORE FLEX 8. SOLID PANEL
More information600/1000V, XLPE Insulated Cables according to IEC
600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single
More informationData sheet chainflex CFSOFT1
to 5 x d Highly flexible, soft design PVC outer jacket Oil-resistant Flame retardant 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Core insulation: Mechanically high-quality TPE mixture
More informationFR-3S Fire Resistant Cables
FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and
More informationPRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath
Spiral cable with outer PUR sheath for exact impulse transmission, unshielded - PUR spiral cable, abrasion-resistant data and control cable for use in data processing, measurement and control engineering
More information1 Conductor Class 5 flexible annealed plain copper conductor
YY Control Cable Application: YY Control is a flexible mulit-core cable with class 5 flexible annealed plain copper conductors, PVC insulation, and a grey PVC sheath. YY Cable is used in fixed installations
More informationPower & Control Cables
The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.
More informationÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V
Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For
More informationZHPCG CK0226 POWER CABLE WIRE & CABLE
ZHPCG CK0226 POWER CABLE WIRE & CABLE ZHPCG CK0226 POWER CABLE WIRE & CABLE Application/Use Rail approved zero Halogen Power Cables, available as 750V or 1800V rated. ZHPCG cables are all Halogen free,
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................
More informationPower & Control Cables. U o. /U 0.6/1 kv - IEC
Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4
More informationINDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *
october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent
More informationRFOU 0.6/1kV Power Cable
RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment
More informationData sheet chainflex CF210.UL
For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic
More informationCaledonian Flame Retardant RS485 Databus Cables
Flame Retardant RS485 Databus Cables Copper Wire Braid(optional) Individual AL/Polyester Tape(optional) Foam PE/Foam skin PE. Stranded Tinned Copper AL/Polyester Tape With Tinned Copper Drain Wire PVC
More informationCables for Railway Technology
Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual
More informationPROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.
PROTEC Screened Wiring Cable Updated to meet new requirements of BS 8436:2011 BASEC approved www.aeicables.co.uk PROTEC CABLES Manufactured and designed to BS 8436 and IS 273 Protec Low Smoke Zero Halogen
More informationTechnical attributes
Technical attributes Standards adapted to DIN VDE 0281 Conductor material Cu, bare Conductor type flexible Conductor standard IEC 60228 Conductor category 5 Core insulation Core s black, number-coded,
More informationData sheet chainflex CF886
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.
More informationIndustrial Cables and Wires
HELUKABEL Products are available from MARYLAND METRICS P.O. Box Owings Mills, MD USA web: http://mdmetric.com ph: ()35-330 (00)3-30 fx: ()35-3 (00)7-939 email: sales@mdmetric.com RFQ form: http://mdmetric.com/rfq.htm
More informationData sheet chainflex CF885.PE
1. Outer jacket: Pressure extruded PVC mixture 2. Core insulation: Mechanically high-quality PVC mixture 3. Conductor: Conductor consisting of bare copper wires For detailed overview please see design
More informationIndustrial Ethernet Cables
Industrial Ethernet Cables www.sab-worldwide.com INDUSTRIAL ETHERNET CABLES Content page Application of Industrial ETHERNET Cables.........................................................................................
More informationH07RN-F TITANEX PREMIUM
New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description
More informationData sheet chainflex CF5
1. Outer jacket: Pressure extruded, gusset-filling, oilresistant PVC mixture 2. Core insulation: Mechanically high-quality TPE or PVC mixture 3. CFRIP: Tear strip for faster cable stripping 4. Conductor:
More informationTHERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx
THERMOCOUPLE CABLE Customization Customized colour option and printing of the outer sheath on request Compensating & Extension 1601 Application: Compensating or Extension Cables are used in temperature
More information6491B / H07Z-R / BS EN Cable
6491B / H07Z-R / BS EN 50525-3-41 Cable Eland Product Group: A3Z APPLICATION Suitable for use in conduit and for fixed, protected installation. For installations where fire, smoke emission and toxic fume
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More informationGlobal data. Electrical parameters
()TSCGEWOEU TEAX TTS 3,6/6 kv: Application Flexible medium voltage reeling cable for application under high mechanical stresses, e.g. high travel speeds, dynamic loads, multiple changes of direction into
More informationH05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.
H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial
More informationCLEVELAND CABLE LOCATIONS
A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2010 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables
More informationPVC motor cables unshielded
PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements
PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application
More informationInstallation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable
According to VDE 0250 part 204 Characteristics Properties Unit Group Power cables < 1 kv Class House wiring cable Type material Cu, bare minal cross section conductor mm² Low smoke (acc. EN 61034-2) Diameter
More informationPROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics
PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with Application Flexible medium voltage reeling cable for high mechanical stresses (e.g. dynamic tensile loads, multiple changes
More information