Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Similar documents
Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal. Front View Side View

Submittal 6 [152] 6 [152] 8 [203]

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

FH Fan-Coil Units Low-Profile, Horizontal

FS Fan-Coil Units Hi-Rise, Vertical

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

New Fan Coil Piping Packages

RBV Engineering Guide

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

New Fan Coil Piping Package. Redefine your comfort zone.

PIPING PACKAGES TABLE OF CONTENTS

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

FN Fan-Coil Units High-Performance, Horizontal

RAH Engineering Guide

FCVC Series VERTICAL FAN COILS

SDL Single-Duct, Low-Height, VAV Terminals

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Complete HVAC Capability

Hi-Performance Series Fan Coil Technical Catalog

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

TSS Single-Duct VAV Terminals

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

Horizontal Series Fan Coil Technical Catalog

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

SECTION AIR TERMINAL UNITS

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

Horizontal Fan Coils 200-1,200 CFM

FDCLP2 Constant Volume Series Flow, Low Profile

University of Delaware

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

BUILD YOUR REPUTATION ON OURS. Horizontal Series FAN COIL TECHNICAL CATALOG

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

Consider The Possibilities...

ACTIVE CHILLED BEAM 6 1/4" HEATING 9 1/2" DISCHARGE DIRECTION. 1 7/8" u 1/4" NOZZLE SIZE:

BVX SERIES VERTICAL DIRECT EXPANSION BLOWER COIL UNITS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

HOW TO SPECIFY SDV UNITS

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

PHCD-Series. Catalog

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

Air-Cooled Fluid Cooler

Dual Duct Variable Air Volume Terminal (Model TDS)

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

forward curved inline duct blowers

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

SINGLE DUCT TERMINAL UNITS

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

WATER SOURCE HEAT PUMPS

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Climas y Proyectos Leyco, S.A. de C.V.

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

FAN POWERED TERMINAL UNITS

ELITE SERIES R-410A Ready - Multi-Position

5/8 (16) DIA. MOUNTING HOLES TYP [4] PLACES. SEE NOTE #3 ACCESS PANEL BOTH SIDES 2 1/2 (64) Unit Size Fan Size L W H C D E F G J (508) (406) 25 (635)

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Typical Applications. Horizontal Installation

Vertical Hi-Rise Fan Coil Unit (Model FS)

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH


Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

High Performance Fan Coils FCHG Genesis Series Horizontal

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

Direct Gas-Fired Heating

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

MQL TABLE OF CONTENTS

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Transcription:

Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 61 [1549] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] 62 [1575] E 19 [483] [635] [737] 39 [991] 49 [1245] 59 [1499] F 36 [914] 70 [1778] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 5. Standard externally foam coated galvanized steel drain pan has 7/8" OM copper outlet. Stainless steel drain pan has ¾ MPT galvanized steel outlet. 6. ux. drain outlet is 5/8" OM copper or 3/8" MPT galvanized steel respectively. 7. See coil connection drawings for coil connection sizes and locations

Horizontal Low Profile oncealed with Plenum with Electric Heat FU-RBHR-2.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] E 19 [483] [635] [737] 39 [991] 49 [1245] F 36 [914] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Standard externally foam coated galvanized steel drain pan has 7/8" OM copper outlet. Stainless steel drain pan has ¾ MPT galvanized steel outlet. 5. ux. drain outlet is 5/8" OM copper or 3/8" MPT galvanized steel respectively. 6. See coil connection drawings for coil connection sizes and locations 61 [1549] 62 [1575] 59 [1499] 70 [1778]

Horizontal Low Profile oncealed with Plenum q RBHR - Heating Only Option q 1R oil q 2R oil q 3R oil q 4R oil FU-RBHR-3.0 05-11-17 Top View Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] E 19 [483] [635] [737] 39 [991] 49 [1245] F 28 3/8 [721] 28 3/8 [721] 28 3/8 [721] 28 3/8 [721] 28 3/8 [721] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 5. See coil connection drawings for coil connection sizes and locations 61 [1549] 62 [1575] 59 [1499] 28 3/8 [721]

Horizontal Low Profile oncealed with Plenum q RBHR with Electric Heat Only FU-RBHR-4.0 05-11-17 Top View Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] B 21 [533] 27 [686] 31 [787] 19 [483] [635] [737] 22 [559] 28 [711] 32 [813] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 41 [1041] 39 [991] 42 [1067] 51 [15] 49 [1245] 52 [1321] 61 [1549] 59 [1499] 62 [1575]

Horizontal Low Profile oncealed with Plenum q RBHR with 6" Round Outside ir FU-RBHR-5.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 61 [1549] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] 62 [1575] E 19 [483] [635] [737] 39 [991] 49 [1245] 59 [1499] F 36 [914] 70 [1778] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 5. Standard externally foam coated galvanized steel drain pan has 7/8" OM copper outlet. Stainless steel drain pan has ¾ MPT galvanized steel outlet. 6. ux. drain outlet is 5/8" OM copper or 3/8" MPT galvanized steel respectively. 7. See coil connection drawings for coil connection sizes and locations 8. Outside air inlet is unfiltered, and may be located on left or right side of unit.

Horizontal Low Profile oncealed with Plenum q RBHR with 6" Round top O.. Inlet FU-RBHR-6.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 61 [1549] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] 62 [1575] E 19 [483] [635] [737] 39 [991] 49 [1245] 59 [1499] F 36 [914] 70 [1778] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 5. Standard externally foam coated galvanized steel drain pan has 7/8" OM copper outlet. Stainless steel drain pan has ¾ MPT galvanized steel outlet. 6. ux. drain outlet is 5/8" OM copper or 3/8" MPT galvanized steel respectively. 7. See coil connection drawings for coil connection sizes and locations 8. 6" [152] round O.. inlet is unfiltered.

Horizontal Low Profile oncealed with Plenum q RBHR with Bottom Filter and Rear O.. Inlet FU-RBHR-7.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041] 51 [15] 61 [1549] 22 [559] 28 [711] 32 [813] 42 [1067] 52 [1321] 62 [1575] E 19 [483] [635] [737] 39 [991] 49 [1245] 59 [1499] F 36 [914] 70 [1778] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Standard control enclosure is mounted on unit side opposite cooling coil connections. Unit casting includes (2) knockouts on each side. Provide sufficient clearance to access electrical controls and comply with applicable codes and ordinances. 4. Optional bottom control enclosure with hinged cover replaces standard side mounted enclosure and includes (2) additional knockouts on bottom of unit, on left side. 5. Standard externally foam coated galvanized steel drain pan has 7/8" OM copper outlet. Stainless steel drain pan has ¾ MPT galvanized steel outlet. 6. ux. drain outlet is 5/8" OM copper or 3/8" MPT galvanized steel respectively. 7. See coil connection drawings for coil connection sizes and locations 8. 6" [152] round O.. inlet is unfiltered. 9. Optional reducer for applications with a 4" [102] round O.. requirement.

FU-RBHR-8.0 05-11-17 RBHR, with Solid Bottom ccess Panel s 38 1/8 [968] STNR PNEL B 14 ½ [368] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. ¼ Turn latch, (2) qty for standard sizes, (3) qty for sizes -. 44 1/8 [1121] 46 [1168] 17 ½ [445] 48 1/8 [1222] 19 ½ [368] 58 1/8 [1476] 24 ½ [622] 68 1/8 [17] 70 [1778] ½ [749] 78 1/8 [1984] 80 [32] 34 ½ [876]

FU-RBHR-9.0 05-11-17 q RBHR Telescoping Bottom Panel ssembly s s 38 1/8 [968] 44 1/8 [1121] 48 1/8 [1222] B 46 [1168] STNR PNEL 14 ½ [368] 17 ½ [445] 19 ½ [368] 4 ¼ [108] 3 ¼ [83] 3 ¼ [83] E 27 ½ [699] 35 ½ [902] 39 ½ [1003] 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 3. Portion of the inlet louver not directly below unit inlet may require covering in the field on applications where infiltration of ceiling plenum air into space is undesired. 4. Telescoping skirt and collar assembly must be field adjusted to assure a proper fit between filter frame and louvered inlet panel assembly. 5. ¼ Turn latch, (2) qty for standard sizes, (3) qty for sizes -. 58 1/8 [1476] 24 ½ [622] 4 ¼ [108] 47 ½ [17] 68 1/8 [17] 70 [1778] ½ [749] 3 ¼ [83] 59 ½ [1511] 78 1/8 [1984] 80 [32] 34 ½ [876] 4 ¼ [108] 67 ½ [1715]

FU-RBHR-10.0 05-11-17 q RBHR, Telescoping Bottom Panel Typical Installation Instructions Suspended Grid/Tile eiling System Stud/rywall eiling System Inlet ollar Installation 1. ll dimensions are Inches [millimeters]. ll dimensions ± ¼ [6mm]. Metric values are soft conversion. 2. ll drawing subject to change without prior notice. 3. Left hand unit shown, right hand unit opposite. 4.Mounting hardware not provided. Mounting holes must be located and drilled to suit individual job requirements. 5. Remove solid louvered bottom panels before mounting frame assembly. 6. Frame assembly must be installed flat and square. Failure to do so may result in poor bottom panel fit and improper airflow pattern. Shim frame to support as required. 7. Telescoping skirt assembly must be field adjusted to assure close fit of filter rack to louvered bottom panel. 8. ttach standard filter rack assembly to bottom of telescoping skirt, after final adjustment of skirt location. Filter removal direction is optional. 9. Portion of the inlet louver not directly below unit inlet may require covering in the field on applications where infiltration of ceiling plenum air into space is undesired.

Horizontal Low Profile oncealed with Plenum FU-RBHR-11.0 05-11-17 q External Feature Space Requirements Left hand unit shown. ll dimensions are inches [millimeters]. V. PKG. SIZE 24 2-WY VLVE PKG. OES 36 3-WY VLVE PKG. OES 37 41, 53 ½ 15 ½ [394] 19 7/8 [5] 17 [432] 13 ¼ [336] 17 ¾ [451] 15 [381] 13 1/8 [333] ¾ 12 [4] ¾ [527] 18 ¼ [463] 14 ¼ [362] 18 7/8 [479] 16 5/8 [397] 14 ¼ [362] 1. ll chilled water piping that projects beyond the condensate pan or the optional auxiliary drip pan must be field insulated by others. 2. uxiliary drip pan shown above is optional, and is mounted on the outlet end of the drip pan. 3. rain pan is installed with the outlet tube(s) on cooling coil connection end of coil on 4-pipe units with optional opposite end connection. 4. imensions shown on this drawing apply to standard W and HW valve packages. Refer to the Piping Package atalog for valve package code details. ontact factory for details on valves packages using non-standard or customer furnished components. 5. Some valve package appurtenances may extend slightly above top of unit. 6. imension L is ±1" [mm] due to multiple source components dimensional variations. imensions shown above should be used to approximate space requirements only, and should not be used for piping rough in purposes. 7. Unions and/or adapter couplings add up 1" [mm] to dimension L. 8 Valve packages with optional strainer will interfere with the optional auxiliary drip pan. Strainer cleanout valve may extend below the bottom of the unit slightly. 9. Provide sufficient clearance to access electrical components and comply with all applicable codes and ordinances. Standard side mounted control enclosure is replaced by the bottom hinged control enclosure on units with optional door interlocking disconnect switch.

FU-RBHR-12.0 05-11-17 General Notes - Piping Packages 1. ll the packages and components described in this brochure are optional, extra cost features. onsult your Superior Rex sales representative for details. Not all components are available on all unit models. See valve package code charts. 2. ll standard valve packages and piping components described in this catalog are for chilled and hot water applications. They may also be used with ethylene and propylene glycol solutions up to % concentration. 3. RBH, RH, and RBV fan coil unit packages are factory assembled and shipped loose for field installation and wiring. ll RV fan coil unit packages are factory assembled, installed, and wired. 4. RBH, RH and RBV unit valve packages are designed to mount directly onto the coil connections. 5. ontrol valve actuators are removable, and may be serviced or replaced without removal of the valve body. 6. ontrol valves are piped normally closed to the coil. For hot water coils, control valves are available normally open. 7. 3-Way control valves are piped as mixing valves. 8. ll ball isolation valves are furnished with an adjustable memory stop feature and may be used as a balancing valve. 9. When ordered, unions are installed at the water coil, and are available on all fan coil units except RV. Unions must be ordered on both coils of 4-pipe units. Unions are not available separately. 10. ll RV units include two flexible stainless steel braided hoses and ball isolation valves per coil. This hose/valve combination provides a "union" type connection to allow coil removal. 11. Pressure/temperature (P/T) ports are located to monitor the pressure and temperature across the coil. 12. utomatic fixed flow controls (F, FN, FS) are available in flow (GPM) ratings as follows: 1/2" = 0.5 to 4.0 GPM in 0.5 GPM increments >4.0 to 6.0 GPM in 1.0 GPM increments 3/4" = 3.0 to 4.0 GPM in 0.5 GPM increments >4.0 to 12.0 GPM in 1.0 GPM increments 1" = 5.0 to 10.0 GPM in 1.0 GPM increments >10.0 to.0 GPM in 2.0 GPM increments Individual coil GPM requirements must be specified at time of order. 13. omponent performance ratings such as v, maximum close-off pressure, operating temperature and pressure, are shown in omponent Specifications. 14. Valve and component performance ratings shown are maximum values. ppearance and actual ratings may vary with individual vendor and component size. 15. djustable flow setter (FS) is rated for full shut-off and replaces the return line ball isolation valve on all products except the RV fan coil unit. 16. 2-Pipe "change-over" units using a 2-way control valve and factory thermostat must be ordered with a " "bleed" line to assure proper changeover thermostat (aquastat) operation. The " "bleed" line is optional on 2-pipe "changeover" units with field provided thermostats. 17. Some piping packages may extend beyond the unit drain pan and/or factory auxiliary drip pan. Requirements for field furnished and installed valve package and piping insulation must be determined by others on an individual application basis. The valve package piping and component details shown in this catalog are for standard valves and components. The suitability of all valve packages and components must be determined by others based on individual application requirements. Titus assumes no responsibility for selection and/or application of valve packages and components. Modulating cooling valve control can increase part load space relative humidity. Titus does not encourage or endorse modulating valve control for fan coil cooling systems, and is not liable for high humidity problems that may result. Modulating heating valve control may result in low leaving air temperatures while the valve reduces flow and as setpoint is approached. ontact Superior Rex for any requirements not shown in this catalog.

FU-RBHR-13.0 05-11-17 RBHR, Piping Packages LEGEN, OMPONENT PRESSURE RTI NGS BVMS: Manual Ball Valves w/memory Stop, 0 PSIG F: Fixed Flow ontrol, 0 PSIG FS: djustable Flow ircuit Setter, 0 PSIG P/T Port: Pressure/Temperature Test Port, 0 PSIG Union: 1 PSIG (contact factory for 0 PSIG) ontrol Valve: 0 PSIG BPV: Balance Bypass Valve, 0 PSIG Y-STR: Y-Strainer BV: Blow own Valve - - - - : Bleed line NOTES: 1. ll drawings subject to change without prior notice. 2. iagrams show component position in relation to fluid flow. ctual valve package configuration varies with unit type, hand connection, pipe size and options. 3. 1/4" bleed line is required on 2-pipe cool and heat auto changeover systems with factory provided thermostats; optional for thermostats by others. 4. Unions provided as standard on all FW piping packages.

FU-RBHR-14.0 05-11-17 STNR FETURES onstruction HRI 4 certified and labeled Galvanized steel construction 1/2" thick fiberglass insulation 1 1/2" duct discharge collar Four point hanger mounting brackets Integral filter rack with 1" throwaway filter Integral rear ducted return - field reversible to bottom return oils ooling - 3 or 4 row chilled water or X, heat pump compatible Heating - 1 or 2 row hot water reheat or preheat position 6 total rows of cooling and heating coils maximum 3/8" O.. seamless copper tubes 0.012" tube wall thickness High efficiency aluminum fin surface for optimizing heat transfer, pressure drop and carryover Left or right hand, same or opposite side connections ccess to entering and leaving air sides for cleaning Removable for service Manual air vents rain Pans Single wall, galvanized steel, externally insulated fire retardant and antimicrobial closed cell foam Positively sloped to drain connection Removable, field reversible 7/8" O.. primary drain connection Fan ssemblies Forwardly curved, WI centrifugal type 115 volt, single phase, three tap PS motors Quick disconnect motor connections Removable fan/motor deck for service Electrical cetl listed for safety compliance Electrical junction box for field wiring terminations Terminal block for field connections Electric Heat ETL listed as an assembly for safety compliance Integral electric heat assembly with removable elements for easy service utomatic reset primary and back-up secondary thermal limits Single point power connection Bottom hinged electrical enclosure OPTIONL FETURES onstruction Foil faced fiberglass insulation Elastomeric closed cell foam insulation Bottom return 1" pleated filters (MERV 8) Spare 1" throwaway filters Telescoping Bottom Panels oils 1/2" O.. seamless copper tubes 0.016" tube wall thickness utomatic air vents Stainless steel coil casings rain Pans Stainless steel construction with external insulation 5/8" O.. secondary drain connection uxiliary drip pans, galvanized or stainless steel Fan ssemblies 8-2, 2 & 277 volt, single phase, three tap PS motors Electrical Bottom hinged cover electrical enclosure SR fan speed controller Fan relay packages Silent solid state fan relays Toggle disconnect switch ondensate overflow switch (drain pan) Main fusing Unit and remote mounted three speed fan switches Electric Heat Manual reset secondary thermal limits oor interlocking disconnect switches Main fusing Silent relay/contactors Piping Packages Factory assembled shipped loose for field installation 1/2" and 3/4", 2 way and 3 way normally closed, two position electric motorized valves Isolation ball valves with memory stop Fixed and adjustable flow control devices Y-strainer Unions and P/T ports Floating point modulating control valves High pressure close-off actuators (1/2" = PSIG; 3/4" = PSIG) Thermostats Remote mounted analog, digital display or programmable 2 and 4 pipe control sequences utomatic and manual changeover Integral three speed fan switches