3M Cold Shrink Splice Kit QS-III 5536A

Similar documents
Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Cold Shrink QS T Trifurcating Transition Splice Kit

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

3M Mechanical Shearbolt Connectors, QCI Series

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

QT-III Cold Shrink Silicone Rubber

Branch Splice QS-2001B

3M Cold Shrink Splice Kits, QS T Series

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Cable Ties. Data Sheet

ELB ES. Product Installation Instructions

ELB ELB

High Voltage Joints and Terminations up to 72,5 kv 145 kv

3M Locator Plate

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

3 Reenterable Encapsulated PST Dome Closure

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

3M Closure System 2-Type Cover (505)

3M Ladder Kit 3M710/MS 2 -TMK-LK

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

Installation Instructions

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

3M Locator Plate

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

3M Fiber Dome Closure FDC 10

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

HVS S 15kV Class

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Data Sheet July For RoHS information, please visit

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC

710 Splicing Rig. Instructions. January E

3M Pleated Foil I/O Cable Assemblies MDR Series

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Door Edge Protection Film 36 inch

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

C Power Connection Kit

Installation Instructions

Product Number

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

(K),(M)430TB/G Up to 36 kv

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

3M Cable Ties Product Guide. Made in USA. & Plenum Rated

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

Kompensator External Low Voltage Heating Cable System

(K),(M),(P)489TB/G Up to 42 kv

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

INSTALLATION INSTRUCTION PEM1367ENG ENGLISH

3M Textool Test and Burn-In Sockets for 1.0 mm Area Array Packages Including Ball Grid Array and Land Grid Array

CS Fiber Optic Splice Case. Instruction

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

GM Specification Annual Test Data

GM Specification Annual Test Data

3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.

Repair Method for 3M Resilient Floor Protection System

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Complete care. kind of cable. for any. Cable Accessory Products FAX CABLE ACCESSORY PRODUCTS

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

protect mask conduct reflect enhance 3M Specialty Tape Solutions

Transcription:

3M Cold Shrink Splice Kit QS-III 5536A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric Neutral (JCN) Cables Instructions IEEE Std. 404 35 kv Class 250 kv BIL CAUTION Working around energized systems may cause serious injury or death. Installation should be performed by personnel familiar with good safety practice in handling electrical equipment. De-energize and ground all electrical systems before installing product. Kit Selection Table Kit Number Cable Insulation O.D. Range Conductor Size Range 5536A 1.24" 2.07" (31,5 52,6 mm) 350 1000 kcmil* (185 500 mm 2 ) * Splices (including size transitions) can be made to smaller or larger conductors (but larger conductors may require special neutral handling), provided both cables are within the Insulation O.D. Range and the connector meets the dimensional requirements shown below. Connector Dimensional Requirements Minimum Inches (mm) Maximum Inches (mm) Outside Diameter 0.87" (22,1 mm) 2.07" (52,6 mm) Length Aluminum (Al/Cu) Compression Length Copper Compression and 3M Shearbolt Connectors QCI 350-750 or QCI 500-1000 7.50" (191 mm) 8.25" (210 mm) March 2011 3 78-8125-9901-3-C

1.0 Kit Contents a. 3M Cold Shrink Splice Body 5468A (1 ea.) b. Cold Shrink Jacketing Tube (1 ea.) c. Cold Shrink Adapter Tube (1 ea.) d. Shielding Sleeve, 1/3 Neutral Maximum (1 ea.) e. Ground Strap (1 ea.) f. Constant Force Spring Ground Connectors (5 ea.) g. Red Compound Tubes (non-silicone grease) (2 ea.) h. Scotch Mastic Sealing Strips 2230, 6" length (6 ea.) i. Scotch Rubber Mastic Tape 2228 Rolls, 2" x 36" (2 ea.) j. Copper Foil Tape, 1/2" x 10" (2 ea.) k. 3M Cable Cleaning Pads CC-3 (1 ea.) l. Cable Preparation Template (2 ea.) m. Instruction Booklet (1 ea.) Do not use knives to open plastic bags. Connector not shown, but if included, it is indicated on the packaging label. Cold shrink adapter tube may not be included in all kits. Kits contain either 1 or 2 Cut-back Templates, as needed per conductor size. 2 78-8125-9901-3-C

2.0 Prepare Cables 2.1 For Tape, LC, Wire Shield or UniShield Cable: 2.1.1 Prepare cables according to standard procedures. Refer to template provided or illustration below for proper dimensions. (Figure 1). Tape & LC Shielded Cables A 3 1/2" (89 mm) B Cable Jacket Metallic Shield Semi-con Insulation Wire Shielded Cable A 3 1/2" (89 mm) B Cable Jacket Wire Shield Semi-con Insulation UniShield Cable A 3 1/2" (89 mm) B Shield Wires Insulation Typical Conductor Size* kcmil (mm 2 ) 350**-500 (185-300) 750-1000** (325-500) Insulation OD Range Inches (mm) 1.24 1.70 (31,5 43,2) 1.59 2.07 (40,4 52,6) Jacket Cutback "A" Inches (mm) 15 3/4 (400) 15 1/4 (387) *For 100% and 133% insulation levels, Insulation OD is the final determining factor. **Cables must be within the Insulation OD Range of the splice kit and the connector must meet the dimensional requirements shown on the front page. Figure 1 Semi-con Cutback "B" Inches (mm) 9 1/4 (235) 8 3/4 (222) 78-8125-9901-3-C 3

2.1.2 For Tape shield and LC shield: Secure end of each metallic shield with a copper tape strip. For Wire shield and UniShield : Carefully bend shield wires back over cable jackets and temporarily secure with vinyl tape. (Figure 2). Tape & LC Shielded Cables Cable Jacket Metallic Shield Foil Tape Semi-con Wire Shielded Cable Cable Jacket Vinyl Tape Shield Wires Semi-con UniShield Cable Cable Jacket Vinyl Tape Shield Wires Figure 2 Go to section 3.0 Park Splice Components. if not transition splicing to JCN or CN cable. 2.2 For Transitions to Jacketed Concentric Neutral (JCN) Cable: 2.2.1 Prepare cables according to standard procedures. Refer to template provided or illustration below for proper dimensions (Figure 3). A B Insulation Semi-con Neutral Wires Typical Conductor Size* kcmil (mm 2 ) 350**-500 (185-300) 750-1000** (325-500) Insulation OD Range Inches (mm) 1.24 1.70 (31,5 43,2) 1.59 2.07 (40,4 52,6) Jacket Cutback "A" Inches (mm) 15 3/4 (400) 15 1/4 (387) *For 100% and 133% insulation levels, Insulation OD is the final determining factor. **Cables must be within the Insulation OD Range of the splice kit and the connector must meet the dimensional requirements shown on the front page. Figure 3 Semi-con Cutback "B" Inches (mm) 9 1/4 (235) 8 3/4 (222) 4 78-8125-9901-3-C

2.2.2 Carefully bend neutral wires back over edge of cable jacket and temporarily secure with vinyl tape. Semi-con Neutral Wires Vinyl Tape Figure 4 Go to section 3.0 Park Splice Components. 2.3 For Transitions to Concentric Neutral (CN) Cable: 2.3.1 Prepare cables according to standard procedures. Refer to template provided or illustration below for proper dimensions (Figure 5). Do not cut neutral wires on CN cables. Concentric Neutral (CN) A B Insulation Semi-con Neutral Wires Typical Conductor Size* kcmil (mm 2 ) 350**-500 (185-300) 750-1000** (325-500) Insulation OD Range Inches (mm) 1.24 1.70 (31,5 43,2) 1.59 2.07 (40,4 52,6) Jacket Cutback "A" Inches (mm) 15 3/4 (400) 15 1/4 (387) *For 100% and 133% insulation levels, Insulation OD is the final determining factor. **Cables must be within the Insulation OD Range of the splice kit and the connector must meet the dimensional requirements shown on the front page. Figure 5 2.3.2 Clean cable semi-con as shown (Figure 6). Semi-con Cutback "B" Inches (mm) 9 1/4 (235) 8 3/4 (222) Clean Semi-Con Binder Wire Folded Back Neutral Wires Figure 6 78-8125-9901-3-C 5

2.3.3 Place a strip of mastic around cable semi-con next to neutral binder. Fold neutrals into mastic and place another binder wire on the other side of the mastic (Figure 7). Binder Wire Mastic Strip Binder Wire Figure 7 2.3.4 Wrap two additional strips of mastic over the first one and cover with two half lapped layers of vinyl tape (Figure 8). 2 additional mastic strips covered with 2 layers vinyl tape Figure 8 2.3.5 Fold neutrals over mastic seal and temporarily secure ends with vinyl tape (Figure 9). Secure folded-back neutral wires with vinyl tape Figure 9 6 78-8125-9901-3-C

3.0 Park Splice Components 3.1 Clean or cover cable jacket if necessary, for cold shrink parking position. Slide jacketing tube onto one cable end. Slide splice body onto opposite cable, loose core end first. For size transitions, park splice on smaller cable (Figure 10). Jacketing is not optional. Cold shrink jacketing tube must be installed. Loose Core End Jacketing Tube Splice Body Figure 10 If space is limited, the jacketing tube and splice body can be put on the cable stacked inside each other. 3.2 Position the expanded shield sleeve onto one cable. The shield sleeve is designed to carry up to 1/3 neutral current (Figure 11). Expanded Shield Sleeve Figure 11 78-8125-9901-3-C 7

4.0 Install Connector If using a crimp-type connector, go to step 4.3. 4.1 If using a 3M Shearbolt Connector QCI 350-750 or QCI 500-1000, refer to the instructions included with the connector for insulation cut-back dimension. Insulation removal length shall not exceed 3 3/4" (95 mm) from conductor end (Figure 12). Refer to connector instructions for dimensions Figure 12 4.2 Install 3M Shearbolt Connector QCI 350-750 or QCI 500-1000 according to the instructions included with the connector (Figure 13). Shearbolt Connector Go to section 5.0 Install Splice. Figure 13 8 78-8125-9901-3-C

4.3 If using a crimp type connector, remove cable insulation for 1/2 connector length plus an allowance* for increases in connector length due to crimping. Insulation removal length shall not exceed 4 1/8" (105 mm) from conductor end. Do not install connector now (Figure 14). * This assumes that the installer has determined the increased length of an aluminum connector crimped with a specific tool and die. Aluminum (Al/Cu) Crimp Connector Growth Chart Conductor Size 350 500 kcmil 1/4" (6 mm) 750-1000 kcmil 3/8" (10 mm) Typical growth allowance (per end) 1) Copper connectors do not require a length change allowance. 2) Maximum aluminum connector crimped length allowed is 8.25" (210 mm). One-half connector length + growth allowance* Figure 14 4.4 For 350 through 1000 kcmil copper connectors, 350 through 750 kcmil aluminum connectors, or connectors with an O.D. between 0.87 1.60" (22,1 40,6 mm): Slide the cold shrink adapter tube onto the insulation with the loose core ribbon end going on first, away from the cable end (Figure 15). Loose Core End Cold Shrink Adapter Tube Figure 15 78-8125-9901-3-C 9

4.5 Install connector. See table (on cover) for proper connector dimensions. (For standard 3M Connectors, refer to table at the end of this instruction for crimping information). Remove any excess oxidation inhibitor from connector ends if aluminum connector is used. File sharp connector flashing if necessary, taking care to remove all metal filings from splice area (Figure 16). Connector 5.0 Install Splice Figure 16 5.1 Apply a tape marker to semi-con insulation shield on cable which does not contain splice. Measure 11 1/4" (286 mm) from center of connector (Figure 17). 11 1/4" (286 mm) Tape Marker Semi-con Figure 17 5.2 If using cold shrink adapter tube: Position adapter tube over the connector. Shrink adapter near center of connector by pulling and unwinding the loose core end in a counter-clockwise direction (Figure 18). Cold shrink adapter tube Figure 18 10 78-8125-9901-3-C

5.3 Clean cables using standard practice: a. Do not allow solvent or abrasive to contact the cable semi-conductive insulation shield. b. Do not reduce cable insulation diameter below 1.24" (31,5 mm) specified for the splice. c. The insulation surface must be round, smooth and free of cuts/voids. Sanding may be necessary, finish sanding should be done with a 300 grit or higher electrical grade abrasive. d. Make certain that the cable insulation is smooth, clean and dry before continuing. 5.4 Apply red compound on cable insulations, making certain to fill in edge of cable semi-con. Do not use silicone grease (Figure 19). Fill semi-con step Fill semi-con step Apply Red Compound Apply Red Compound Figure 19 5.5 Position the splice body over connector area, aligning end of the splice body (not the core) at the center of the tape marker. Slowly start to remove the splice core by pulling and unwinding the loose core end counterclockwise, allowing only ¼" (6 mm) of the splice to shrink onto the tape marker. Carefully slide the splice body off the tape marker by pulling and twisting until the entire tape marker is exposed. Continue removing the core to complete the splice body installation (Figure 20). The splice body ends must overlap onto the semi-con of each cable by at least 1/2" (13 mm). Do not push the splice body toward the tape marker as this may cause the end to roll under. If the end does roll under, DO NOT use sharp-edged tools to pull it out as this could cut and damage the splice. Unwind Counter-clockwise Align splice body with tape marker Figure 20 78-8125-9901-3-C 11

6.0 Connect Shield Sleeve 6.1 Center the expanded shield sleeve over splice body. Hand-tighten sleeve from splice center outward in both directions (Figure 21). Hand-tighten sleeve from splice center outward Shield Sleeve Figure 21 6.2 For Tape Shielded and LC Shielded Cables: 6.2.1 Secure sleeve to cable metallic shield next to each cable jacket using two wraps of vinyl tape (Figure 22). Cable Jacket End Vinyl Tape Shield Sleeve Figure 22 6.2.2 Bend ends of sleeve back over vinyl tape and secure with constant force springs at 1 1/2" (38 mm) and 2 1/2" (64 mm) from jacket end. Trim off excess sleeve 1/2" (13 mm) from springs, if necessary (Figure 23). 2 1/2" (64 mm) 1 1/2" (38 mm) Trim end of sleeve if necessary Constant Force Springs Folded over shield sleeve Figure 23 12 78-8125-9901-3-C

6.2.3 Wrap two layers of stretched vinyl tape over springs (Figure 24). Vinyl Tape 6.3 For Wire Shielded Cable: Figure 24 6.3.1 Carefully remove vinyl tape from drain wires. Secure sleeve to cable semi-conducting layer next to each cable jacket using two wraps of vinyl tape (Figure 25). Drain Wires Vinyl Tape Figure 25 6.3.2 Bend ends of sleeve back over vinyl tape. Position drain wires over the shield sleeve and secure with constant force springs at 1 1/2" (38 mm) and 2 1/2" (64 mm) from jacket end. Trim off excess sleeve 1/2" (13 mm) from springs, if necessary (Figure 26). 2 1/2" (64 mm) 1 1/2" (38 mm) Trim end of sleeve if necessary Constant Force Springs Drain wires over shield sleeve Figure 26 78-8125-9901-3-C 13

6.3.3 Wrap two layers of stretched vinyl tape over springs (Figure 27). Vinyl Tape 6.4 For UniShield Cable: Figure 27 6.4.1 Carefully remove vinyl tape from drain wires. Secure sleeve to cable semi-con jacket next to bent-back shield drain wires using two wraps of vinyl tape (Figure 28). Drain Wires Vinyl Tape Figure 28 6.4.2 Bend ends of sleeve back over vinyl tape. Carefully position drain wires over the shield sleeve. Secure with constant force springs 1 1/2" (38 mm) and 2 1/2" (64 mm) onto drain wires. Trim off excess sleeve 1/2" (13 mm) from springs, if necessary (Figure 29). 2 1/2" (64 mm) 1 1/2" (38 mm) Trim end of sleeve if necessary Constant Force Springs Drain wires over shield sleeve Figure 29 14 78-8125-9901-3-C

6.4.3 Wrap two layers of stretched vinyl tape over springs (Figure 30). Vinyl Tape 6.5 For CN and JCN Cable: Figure 30 6.5.1 Connect shield sleeve to metallic (LC, etc.) shield first. Remove vinyl tape from neutral wires and route neutral wires upward next to end of cable jacket (or CN binder) (Figure 31). Neutral Wires Figure 31 6.5.2 Secure sleeve to cable semi-con next to neutral wires using two wraps of vinyl tape. Cover the end of the splice body (as shown below) with two half-lapped layers of rubber or vinyl tape (Figure 32). Neutral Wires Shield Sleeve (twisted) Vinyl Tape Rubber or Vinyl Tape Figure 32 78-8125-9901-3-C 15

6.5.3 Place a 3-4" piece of cable jacket over the rubber or vinyl tape and cable semi-con as shown below. Secure with vinyl tape (Figure 33). Cable Jacket Piece Figure 33 6.5.4 Keeping the connector as close as possible to the cable, connect shield sleeve and neutrals together, using a suitable compression connector. ( INLINE, C, or H type). Crimp connector following the connector manufacturer s recommendation. Trim excess neutral wires and sleeve extending beyond the connector (Figure 34). Compression connector Figure 34 6.5.5 Fold connector over shield sleeve, ensuring that the connector is over the cable jacket piece, and secure with vinyl tape (Figure 35). Vinyl Tape Figure 35 16 78-8125-9901-3-C

7.0 Grounding (Optional) Use these instructions if circuit grounding is required at this location. 7.1 On metallic shielded (non-neutral) cable, wrap the ground strap around the shield sleeve (between the cable jacket and constant force spring) with the tails towards the cable jacket (Figure 36). Ground Strap Figure 36 7.2 Secure ground strap to the shield sleeve using a constant force spring (Figure 37). Constant Force Spring Figure 37 7.3 Wrap two layers of stretched vinyl tape over spring (Figure 38). Vinyl Tape Figure 38 78-8125-9901-3-C 17

7.4 Place one mastic sealing strip on the cable jacket under the solder blocks of the ground strap (Figure 39). Solder Block Mastic Strip Figure 39 7.5 Place other strip over the solder blocks. Press the mastic strips around the solder block and to the cable jacket. If tails overlap at the solder blocks, place a piece of mastic between them (Figure 40). Second Mastic Strip 8.0 Install Jacket Figure 40 Jacketing is not optional. 8.1 Apply one roll of slightly stretched rubber mastic tape around each jacket end (tacky side toward cable). Stretch and tear off the end of the rubber mastic as shown below. If ground strap was applied, tape over mastic sealing strips. For CN cable, cover mastic seal next to binder (Figure 41). Rubber Mastic Rubber Mastic Stretch and tear off last 1 2" (25 50 mm) of rubber mastic Figure 41 18 78-8125-9901-3-C

8.2 Begin to install the cold shrink tube by completely covering the rubber mastic, and slowly pulling and unwinding the inner core counterclockwise toward the splice body. The outer core should remain relatively stationary while unwinding the inner core. If the outer core begins to move towards the first mastic seal, gently pull the outer core and jacketing tube towards the second mastic seal and continue unwinding the inner core (Figure 42). Unwind Counter-clockwise Figure 42 8.3 Continue to install the cold shrink tube over the rubber mastic on the other cable by slowly pulling and unwinding the outer core counterclockwise. This portion of the cold shrink tube installs differently than typical cold shrink products in that as the tube shrinks, the end rolls under. The tube may need a slight push to get over the second mastic seal (Figure 43). Unwind Counter-clockwise Figure 43 In applications where the splice is regularly exposed to high levels of ultra-violet radiation (i.e. direct sunlight), wrap two half-lapped layers of Scotch Super 33+ Vinyl Electrical Tape or Scotch Vinyl Electrical Tape Super 88 over the re-jacketing tubes. Connect optional grounding. 78-8125-9901-3-C 19

Crimping Tool - Die Sets (number of crimps/end) 3M Connector Number Conductor Size (kcmil) Y34A B urndy Thomas & Betts Corp. Y35, Y39 Y1000** TBM 8 TBM 12 TBM 15 Y45*, Y46* Square D Co. Anderson Div. VC6-3** VC6-FT** VC8C** 10011 (Cu) 350 A 31R (2) U 31RT (2) R ed (3) 71H (3) ( 2) 20011 (Al/Cu) 350 U 31ART (2) ( 1) 87H (3) 87H (3) ( 2) 11011 (Cu) 350 A 31R (3) U 31RT (3) R ed (4) 71H (4) ( 3) CI-350 (Al/Cu) 350 U 31ART (2) 87H (2) 87H (2) ( 3) 20012 (Al/Cu) 400 U 32ART (4) ( 1) 94H (4) 94H (4) ( 2) (2) 10014 (Cu) 500 A 34R (2) U 34RT (2) B rown (3) 87H (3) ( 2) 20014 (Al/Cu) 500 U 34ART (4) ( 1) 106H (3) 106H (4) ( 2) (2) 11014 (Cu) 500 A 34R (4) U 34RT (3) B rown (4) 87H (4) ( 3) CI-500 (Al/Cu) 500 U 34ART (3) 106H (3) ( 3) 20016 (Al/Cu) 600 U 36ART (4) ( 1) 115H (3) ( 3) (3) 10019 (Cu) 750 U 39RT (3) 106H (3) 20019 (Al/Cu) 750 U 39ART (4) 125H (5) ( 3) (3) 11019 (Cu) 750 U 39RT (5) 106H (4) CI-750 (Al/Cu) 750 S 39ART (3) 140H (3) (3) 10024 (Cu) 1000 S 44RT, P44RT (4) 125H (3) 20024 (Al/Cu) 1000 S 44ART, P44ART (4) 140H (4) 11024 (Cu) 1000 S 44RT, P44RT (4) 125H (4) *Y45 and Y46 accept all Y35 dies ("U Series"). For Y45, use PT6515 adapter. For Y46, use PUADP adapter. **Anderson VC6-3, VC6-FT, VC8C and Burndy Y1000 require no die set. 3M and Super 33+ are trademarks of 3M Company. Scotch is a registered trademark of 3M Company. UniShield is a registered trademark of General Cable Technologies Corporation. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electrical Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 800-245-3573 Fax 800-245-0329 www.3m.com/electrical Please Recycle. Printed in USA. 3M 2011. All Rights Reserved. 78-8125-9901-3-C