VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Similar documents
FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

VCD-23. Low Leakage CONTROL DAMPER

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-23 Low Leakage CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER

VCD-23. Flange Options. Size Limitations

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

Thermal Isolation. Break

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-212. Combination FIRE SMOKE DAMPERS

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

HVAC Control & Balancing Dampers

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

HVAC Control & Balancing Dampers

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products AMD AMS IAQ

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

ID-141x 12-Gauge Hat Channel Industrial Damper

Series HCD Airfoil Control Damper

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

ARROW INDUSTRIAL PRODUCTS

Motorized Fire Dampers

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

LOW LEAKAGE VOLUME CONTROL DAMPER

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

SECTION CONTROL DAMPERS

L O U V E R S & D A M P E R S

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

BD-1600 Balancing/Zone Control Damper

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

ARROW UNITED INDUSTRIES

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

AD-1250 Airflow Measuring Station

PC-125x Counter-Balanced Backdraft Damper

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

DAMPERS WE CONTROL AIR

Introduction to Johnson Controls Dampers

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

SD-1250 and SD-1600 Series Smoke Dampers

Fusible Link (replaceable) Horizontal Mount

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

Installation, Operation and Maintenance Manual

Installation, Operation, and Maintenance Instructions

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Air Quality Solutions

VD-1600 Series Volume Control Dampers

VOLUME CONTROL DAMPER

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

AIR DUCT ACCESSORIES

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Fusible Link (replaceable) Horizontal Mount

MOTORIZED VOLUME DAMPER

When Time is Everything... We Manufacture in Days - Not Weeks!

Blast Protection Damper

CFSD Series. Product Description

Transcription:

Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure and velocity systems. This model is IECC (International Energy Conservation Code) compliant with a leakage rating of 3 cfm/ft 2 @ 1 in. wg (55 cmh/m 2 @.25 kpa) or less. Ratings : : Leakage: Temperature: Up to 6.0 in. wg (.5 kpa - 1.5 kpa) pressure differential Up to 6,000 (30.5 m/s) 6 cfm/ft 2 @ 4 in. wg (110cmh/m 2 @ 1 kpa) 3 cfm/ft 2 @ 1 in. wg (55cmh/m 2 @.25 kpa) Up to 250 F (121 C) Construction Standard Optional Frame Material Aluminum - Frame Type 5 in. x 1in. (127mm x 25mm) hat channel Single Flange, Reverse Flange, Quick Connect Blade Material Extruded Aluminum - Blade Type Airfoil - Linkage Axle Bearings Plated steel out of airstream, concealed in jamb Synthetic with thrush washers 304SS 304SS with thrush washers Axle Material Plated steel 304SS Blade Seals TPE Silicone Jamb Seals 304SS - Paint Finishes Mill Finish Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar 70%; Anodize Vertical Airfoil Blade Control Damper 5 in. 5 in. W* W & H dimension furnished approximately 1/4 in. (6mm) undersize.optional standoff bracket and extension pin shown. Parallel Blades Opposed Blades 1¼ in. (typical) 1¼ in. (typical) H* Size Limitations in. (mm) W x H Channel Frame Type Quick Connect Single or Reverse Flange Blade Action Parallel Parallel Parallel Minimum Sizes Maximum Sizes Single Section Multi- Section * varies by actuator 6 x 8 (178 x 203) 5 x 8 (127 x 203) 74 x 60 (1880 x 1524) 120 x 60 (3048 x 1524) 6 x 8 (178 x 203) Features and Options: Blade seals - pressure activated to produce tighter sealing Wide range of electric and pneumatic actuators available. Actuators (when supplied) are mounted on the top or bottom Clean wrap available NEMA 3, 4, 4x or 7 available Installation instructions available at www.greenheck.com

Frame Type Options Channel Frame Single Flange Reverse Flange * Width and height is based on outside dimension. W & H dimensions furnished approximately 1/4 in. (6mm) undersize. Quick Connect 1 3/8 in. Note: When ordering the Quick Connect Frame, size is based on duct size ( or inside dimension of the damper frame). Quick connect frame is actual size. 1 3/8 in.

Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of 0.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. 6D Figur e 5.3 Figur e 5.2 Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. Figure 5.5

Data Figur e 5.2 12 in. x12 in. (305mm x 305mm) 24x24 (610 mm x 610mm) 36x36 (914mm x 914mm) 12x48 (305mm x 1219mm) (in wg) 48x12 (1219mm x 305mm) 500.01 500.01 500.01 500.01 500.01 1000.06 1000.04 1000.03 1000.03 1000.06 1500.13 1500.10 1500.06 1500.06 1500.13 2000.23 2000.18 2000.12 2000.10 2000.23 2500.35 2500.28 2500.18 2500.16 2500.36 3000.50 3000.40 3000.26 3000.23 3000.51 3500.68 3500.54 3500.35 3500.30 3500.71 4000.88 4000.70 4000.46 4000.39 4000.93 6D 12 in. x12 in. (305mm x 305mm) Figur e 5.3 24x24 (610 mm x 610mm) 36x36 (914mm x 914mm) 12x48 (305mm x 1219mm) (in wg) 48x12 (1219mm x 305mm) 500.01 500.01 500.01 500.01 500.01 1000.03 1000.02 1000.01 1000.02 1000.03 1500.07 1500.04 1500.02 1500.04 1500.06 2000.14 2000.08 2000.04 2000.08 2000.11 2500.21 2500.13 2500.06 2500.12 2500.17 3000.29 3000.19 3000.09 3000.18 3000.25 3500.39 3500.26 3500.13 3500.24 3500.34 4000.51 4000.34 4000.17 4000.31 4000.45 12 in. x12 in. (305mm x 305mm) Figure 5.5 24x24 (610 mm x 610mm) 36x36 (914mm x 914mm) 12x48 (305mm x 1219mm) (in wg) 48x12 (1219mm x 305mm) 500.04 500.03 500.03 500.03 500.03 1000.14 1000.12 1000.10 1000.11 1000.11 1500.31 1500.27 1500.22 1500.26 1500.25 2000.55 2000.48 2000.39 2000.46 2000.46 2500.86 2500.75 2500.61 2500.72 2500.72 3000 1.23 3000 1.07 3000.87 3000 1.02 3000 1.02 3500 1.67 3500 1.47 3500 1.19 3500 1.40 3500 1.40 4000 2.19 4000 1.91 4000 1.56 4000 1.83 4000 1.83

Leakage Data Leakage Data Air leakage is based on operation between 32 F (0 C) and 120 F (49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data are based on a torque of 5.0 in.lb./ft² (0.56 N m) applied to close and seat the damper during the test. 6 Limitations 6.0 in. wg Maximum Damper Width Leakage Class* 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 60 in. (1524mm) 1A 1 * applies to opposed blades only *Leakage Class Definitions The maximum allowable leakage is defined as the following: Leakage Class 1A - 3 cfm/ft 2 @ 1 in. wg (class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 2 @ 1 in. wg - 8 cfm/ft 2 @ 4 in. wg - 11 cfm/ft 2 @ 8 in. wg - 12.6 cfm/ft 2 @ 10 in. wg 74 Limitations 5.0 in. wg 60 Pr essur e 4 2 4.0 in. wg 3.0 in. wg 2.0 in. wg Damper Width (in.) 48 36 24 6000 5000 4000 3500 3000 12 0 0 12 24 36 Damper Height (in.) 48 60 0 0 12 24 36 48 Damper Height (in.) NOTE: will withstand higher pressures and velocities. Displayed ratings are conservative to prevent misapplication. Consult Greenheck if you have an application outside these limitations. Temperatures in excess of 180 F (82ºC) require special consideration. 60 This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. Actuator Mounting External - includes extension pin (standoff bracket optional) External kit - actuator and all mounting hardware Internal - blade lever 5 in. 5 3/8 in. (136.5mm) 3 3/4 in. (95mm) 7 3/4 in. (197mm)

Space Envelopes Specifications On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. D T Optional Jackshaft B Damper frame Actuator Type/Model Width T B D Inches Inches AFBUP (-S) and >6 to <10 0 12 3 4 6 FSNF Series, Belimo MSxx20 Series, Honeywell; 33x- >10 to <18 0 2 6 2976 Series, Siemens >18 0 0 6 FSLF, LF and TFB Series, Belimo >6 to <10 0 3 1 2 6 >10 0 0 6 MSxx04 & MSxx09 Series, >6 to <9 0 4 3 4 6 Honeywell >9 0 0 6 >6 to <10 0 12 3 4 6 MS75xx Series, Honeywell >10 to <18 0 7 6 >18 0 0 6 >6 to <10 0 7 1 2 6 33x-4551 Series, Siemens >10 to <17 0 1 1 2 6 >17 0 0 6 <12 N/A N/A N/A 331-2856, Siemens >12 to <18 0 2 1 2 9 >18 0 0 9 Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall consist of: heavy gauge aluminum frame (0.125 in. [3.2mm] thick) with 5 in. (127mm) depth formed into a structural hat channel shape with reinforced corners; airfoil shaped, extruded aluminum blades (0.063 in. [1.6mm] thick) with metal blade to blade overlap (seal to seal only contact is not acceptable); blades shall be completely symmetrical relative to their axle point, presenting identical resistance to airflow in either direction or pressure on either side of the damper; 1 2 in. (6mm) dia. plated steel axles turning in synthetic (acetal) sleeve bearings; TPE blade seals ; flexible stainless steel jamb seals; and external (out of the airstream) blade-to-blade linkage. Damper manufacturer s printed application and performance data including pressure, velocity, leakage, and temperature limitations shall be submitted for approval showing damper suitable for pressures to 6 in. wg (1.5 kpa), velocities to 6000 (30.5 m/s) and temperatures to 250 F (121 C). Damper leakage for approval showing standard air leakage less than 6 cfm/sq.ft. @ 4 in. wg (110cmh/m sq. @ 1 kpa). Testing and ratings to be in accordance with AMCA Standard 500-D. Basis of design is Greenheck model. Copyright 2018 Greenheck Fan Corporation Rev. 12 February 2018