ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

Similar documents
Outdoor Padmount Switching Products

MDS Dead-front Padmount Switchgear Style Guide 1VAM SG May 2010 Revision D

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

ME Series Fused Sectionalizing Enclosures Style Guide 1VAM SG April 16, 2009 Revision D

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

Bus and fuse schematic is orange-colored vinyl for high visibility

S&C Manual PME Pad-Mounted Gear

SWITCHGEAR DIVISION PRODUCT PROFILES

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV

Underground Distribution Switchgear

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR

15-kV Safefront 600 Amp Primary Transformer Station Pad-Mounted Outdoor

Advance 27 ANSI 27 kv switchgear

100 / 110 DRYWELL FUSE SPECIFICATION

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

WARNING. TYPE PSI/II PAD-MOUNT SWITCHGEAR with Non-Loadbreak Fuse Mountings 15kV 25kV INSTRUCTIONS. Qualified Persons. For Installation and Operation

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

SWITCHGEAR DIVISION PRODUCT PROFILES

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

Type MOST oil switch

SPECIFICATION BULLETIN

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

15 kv and 25 kv Thru-Bushings

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Underground Distribution Switchgear

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25 kv Apparatus Bushings

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Medium Voltage Outdoor Apparatus Portfolio 2009

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

C1000 Series Automatic Cap Bank

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Disconnect & ByPass Switches

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Quality Products. Service Excellence.

Figure 1. HX cutout fuseholders.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

MP Meter-Pak Meter Centers

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Switchgear Skid, C1192

AutoLink Frequently Asked Questions

TYPE BLT DISCONNECT SWITCHES

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Cleaning Flooded Gear

PRODUCT BROCHURE. Steel City fire-rated poke-through systems

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

SECTION PANELBOARDS

Design Standard. Purpose: Design Standard:

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Figure 1. HX cutout fuseholders. Positive Interruption

Three-Phase Pole Mounted Recloser

BRACKETS, MOUNTS & HARDWARE

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

DEADFRONT VACUUM INTERRUPTER PAD-MOUNTED SWITCHGEAR 15kV 25kV

Wall-Mount Enclosures CONCEPT Wall-Mount Enclosures

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

www. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva

Product Selection Guide

Type IMC Indoor current transformer

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

Cleaning Flooded Gear

A. Submit manufacturer's literature and technical data before starting work.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Power IT Liquid Filled Single Phase Padmounted Transformers kva

SECTION PADMOUNT TRANSFORMER - OIL FILLED

Transcription:

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

ABB ME series fused sectionalizing enclosures ABB's dead-front Padmount ME series fused sectionalizing enclosures are designed for 200 ampere circuits to protect and sectionalize an underground electrical distribution system. The single and three-phase versions are designed for long term durability and are available in 15 or 25 kv to fit utility system requirements. Provides an economical circuit protection option for singlephase circuits and three-phase circuits where gang operated switching is not required Available in power fusing (MEP) or current limiting fusing (MEC) styles with a wide variety of fuse mounting options Dead-front construction with a metal partition to separate the cable terminating compartment from the fuse compartment Dead-front partition is painted light gray for improved visibility Single-phase switching using loadbreak inserts and elbow connectors or optional loadbreak fuse mountings Available in single-phase and three-phase arrangements with one or two sources and one or two loads 200 ampere bushing wells are standard, with 600 ampere source bushings optional Inner protective door barriers on live-front side Circuit diagram on dead-front side Grounding provisions in each compartment Electrical grade (GPO-3) fiberglass barriers for phase separation 2 ME series dead-front fused sectionalizing enclosures Descriptive bulletin

ABB's Padmount switching products represent over 30 years of quality design and manufacturing of air insulated dead-front products for underground distribution systems. Enclosure features Heavy duty channelized construction for superior rigidity and tamper resistance Premium powder coating and rugged construction meet or exceed ANSI C57.12.28 and RUS U-4 requirements for padmount equipment enclosure integrity Flexible modular design promotes life cycle support, including field upgrades and repairs Tamper resistant ventilation to prevent excessive condensation build-up Blind threaded lifting provisions Stainless steel hinges Available in mild steel, stainless steel or aluminum construction Folding three-point door handle assembly Manually operated latch requires deliberate action to open or close doors Corrosion resistant housing Stainless steel penta-head security bolt Heavy duty cast aluminum folding handle Penta-head bolt hidden behind handle when padlocked Complete handle assembly or individual parts easily replaceable Automatic door stay assembly Secures door in open position Easy release with hand or foot Easily removable doors Descriptive bulletin ME series dead-front fused sectionalizing enclosures 3

Enclosure features Parking stands accept industry standard cable parking devices Circuit diagram (mimic bus) in cable compartment Optional phase and/or bushing identification letters/numbers 200 ampere bushing wells standard (600 ampere source bushings optional) 3-point door latch with flush folding handle and penta-head security bolt Stainless steel lift-off hinges Grounding provisions for each phase and also on enclosure side panels Light gray dead-front for improved visibility Dead-front panel reinforced to prevent flexing NEMA GPO-3 fiberglass inner protective barriers inside fuse compartment; doors secured with penta-head bolt (clear (lexan) barriers optional) Blind threaded lifting provisions NEMA Mr. Ouch danger labels inside doors and on innerbarriers NX Clip style current limiting (MEC) fuse mountings shown (power fuse style (MEP) mountings available) Automatic door stay assembly secures door in open position Open bottom with 2 base flange (floor pan optional) Tamper resistant ventilation top and bottom NEMA GPO-3 fiberglass phase/ fuse separation barriers 4 ME series dead-front fused sectionalizing enclosures Descriptive bulletin

MEP Power Fuse Enclosure shown with non-loadbreak fuse mountings and special customer labeling MEP Power Fuse Enclosure shown with loadbreak fuse mountings and optional ANSI-70 light gray color MEC Current Limiting Enclosure shown with NX clip style fuse mountings Descriptive bulletin ME series dead-front fused sectionalizing enclosures 5

MEC current limiting fusing Part number & option guide Available options and accessories: Fuse extenders (for NX fuses) Clear polycarbonate (Lexan) inner door barriers Fuse storage provisions Copper bus Copper core bushings (600 A) Factory installed bushing inserts Hex-head security bolts for doors and barriers Grounding connectors One-line diagram kv class Phase Dimensions (in) Catalog number H W D 15 1 42 30 36 MEC1111 15 3 42 66 36 MEC1311 25 1 52 36 42 MEC2111 25 3 52 72 42 MEC2311 15 1 42 30 36 MEC1121 15 3 42 66 36 MEC1321 25 1 52 36 42 MEC2121 25 3 52 72 42 MEC2321 15 1 42 30 36 MEC1112 15 3 42 66 36 MEC1312 25 1 52 36 42 MEC2112 25 3 52 72 42 MEC2312 15 1 42 30 36 MEC1122 15 3 42 66 36 MEC1322 25 1 52 36 42 MEC2122 25 3 52 72 42 MEC2322 Note: Consult factory for alternate circuit confi gurations Fuse mounting options: Option A - Type NX Arc-Strangler hinge style mountings - code 1 Option B - Type NX Arc-Strangler hinge style mountings - code 2 Option D - Type NX clip style mountings - code 5 (standard for 15 kv) Option E - Type NX clip style mountings - code 6 (standard for 25 kv) Note: Fuse mountings accept Cooper NX style fuses or equivalent with 5/8" ferrules. Fuse extenders can be provided to increase length of fuse from code 4 to 5 or from code 5 to 6. 6 ME series dead-front fused sectionalizing enclosures Descriptive bulletin

MEP power fusing Part number & option guide Available options and accessories Fuse holders or fuse end fittings Clear polycarbonate (Lexan) inner door barriers Fuse storage provisions Copper bus Copper core bushings (600 A) Factory installed bushing inserts Hex-head security bolts for doors and barriers Grounding connectors One-line diagram kv class Phase Dimensions (in) Catalog number H W D 15 1 52 36 42 MEP1111 15 3 52 72 42 MEP1311 25 1 58 36 48 MEP2111 25 3 58 84 48 MEP2311 15 1 52 36 42 MEP1121 15 3 52 72 42 MEP1321 25 1 58 36 48 MEP2121 25 3 58 84 48 MEP2321 15 1 52 36 42 MEP1112 15 3 52 72 42 MEP1312 25 1 58 36 48 MEP2112 25 3 58 84 48 MEP2312 15 1 52 36 42 MEP1122 15 3 52 72 42 MEP1322 25 1 58 36 48 MEP2122 25 3 58 84 48 MEP2322 Note: Consult factory for alternate circuit confi gurations Fuse mounting options: Option R - SM-20 non-loadbreak fuse mountings to accept SMU-20 power fuses Option S - SML-20 loadbreak fuse mountings to accept SMU-20 power fuses Option T - SM-4 non-loadbreak fuse mountings to accept SM-4 power fuses Option U - SML-4Z loadbreak fuse mountings to accept SM-4 power fuses Descriptive bulletin ME series dead-front fused sectionalizing enclosures 7

Contact us ABB Inc. 655 Century Point Lake Mary, FL 32746 Phone: +1 407 732 2000 Customer service: +1 800 929 7947 ext. 5 +1 407 732 2000 ext. 2510 E-Mail: customer.service.group@us.abb.com www.abb.com/mediumvoltage All sales are subject to ABB Inc. General Terms and Conditions of Sale. While every effort has been made to assure accuracy, the information in this document is subject to change without notice. Copyright 2008, 2011 ABB Inc. All rights reserved. 1VAM224705-DB Rev C January 2011