CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

Similar documents
CSO/STORMWATER MANAGEMENT. HYDROVEX FluidGate Control Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidVertic Vertical Vortex Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

CSO/STORMWATER MANAGEMENT. HYDROVEX CCV Check Valve

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMid Flow Monitoring & Regulating Station with Siphon (Type G)

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

pneumatic outflow control

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

A u t o matic Backw ater V alve

neptunetg.com Neptune Technology Group Inc Alabama Highway 229 Tallassee, AL USA Tel: (800) Fax: (334)

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

Sleeve Valves Energy Dissipaters

HP Turbine Installation and Maintenance Guide

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

ABS lifting station Synconta

Gauges, Sight Glasses and Vacuum Breakers

PUMP TYPES. Pump Sizing. Dose to Gravity. Pumping to Gravity Distribution. Systems that need a Lift. Distribution Box and Tiered Trenches.

Nomenclature. Nomenclature Distributing coil types

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

TECHNICAL INFORMATION LOW FLOW METER. (ethylene propylene rubber) optional. Valve trim (seat and stem) is 316 stainless.

Crispin Valves Operating Guide. Crispin

3. The working pressure shall be 145 psi and tested to 230 psi.

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Lane Reverse Q Pond Outlet Installation and Maintenance Guide

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

Experiment (4): Flow measurement

TRU/FLO Compound Installation and Maintenance Guide

VENT SILENCER PRODUCT GUIDE

INNOVATIVE New Generation of Backwater Valves TECHNOLOGY. Fullport Backwater Valve NEW. Access Box Model # PE 2013

1BGrease Traps and. Frequently Asked Questions About Grease:

PAK BENG HYDROPOWER PROJECT

Annular flow valve SV-FA

Low-Cost Pipeline Flow Meter

CASH VALVE K SERIES BACK PRESSURE VALVES

JOULE RETRACTABLE RETARDER INSTALLATION & MAINTENANCE

Spiral Scraper Clarifier

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

FIXED CONE VALVE. The flow is guided by the inner vanes, in order to decrease the vortex and the vibration;

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

Ballcentric Plug Valve

MODEL 7ASX-8 SPECIFICATION

Grease Inspection Program

Valve Selection. 1. Function and service considerations

AZURN Company Fixed Cone Valves. Howell-Bunger and Ring Jet Valves

RAIN BIRD - AQUAGATOR AQUAGATOR INSTALLATION & TROUBLESHOOTING MANUAL

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

Crane. UNI-CHEK High Performance Check Valves

Automatic Control Valves

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

WSB clean: Installation Manual

HYDRAULIC CONTROL VALVES

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

High-Strength Steel Reinforced HDPE Pipe. For pipe specifications, please visit:

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Applied Fluid Mechanics

TECHNICAL DATA OBSOLETE

Hydraulics Guide. Table 1: Conveyance Factors (English Units)... 7 Table 2: Conveyance Factors (Metric Units)... 8

INSTALLATION INSTRUCTIONS

Fluid Coil Installation, Operation and Maintenance

OPERATION & MAINTENANCE MANUAL POLDER PUMP. A Mark of Quality

General Engineering Spray Nozzles & Accessories

HTX-HTH SEPARATORS I&O MANUAL

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

Features 1. Differential Latch-type, lightweight, dependable

Engineering & Design Data

TORQUE-MOTORS. as Actuators in Intake and Exhaust System. SONCEBOZ Rue Rosselet-Challandes 5 CH-2605 Sonceboz.

Flow Control Valve IOM 770-U

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

Types and 52.20, Specialized test procedure Milk receiving and milk pick-up metering systems

Silencers. Transmission and Insertion Loss

SIL Inline Single Stage Centrifugal Pumps

CHAPTER 7 PUMPING SYSTEM DESIGN

5. Underground Requirements

VACOMASS. Technical information VACOMASS square diaphragm control valve

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Cash Valve. A Series. Pressure Regulators. Flow Control. Issued - January 2001 CAVMC-0508-US-0609 ISO 9001 Certified

iglidur G The General Purpose Bearing: most popular iglidur material worldwide

MODEL H INSTALLATION INSTRUCTIONS

VB VALVES & AUTOMATION

Regular inspections are recommended to ensure that the system is functioning as designed.

Tips for Installation, Calibration and Operation of SmartSwitch Tank Management Systems. Contents: Page

Transportation Products

Tow-Bro Unitube Sludge Removers

A new in-chamber double longitudinal culverts filling and emptying system for high head and large navigation lock by

CULVERT DESIGN WITH HY-8

radial GATES Waterman Industries of Egypt

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

THE CARBURETOR: THE ADDITIONAL SYSTEMS

TECHNICAL DATA CAUTION

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

AMERICAN RECIRCULATING SAND FILTER SYSTEMS

7.4 Parshall flumes Description

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

Transcription:

CSO/STORMWATER MANAGEMENT HYDROVEX FluidHook Control Gate Valve

HYDROVEX FLUIDHOOK CONTROL GATE VALVE APPLICATION The flow regulation at storm overflows or retention facilities is usually performed with either a flow regulating valve or a calibrated orifice. These methods, unfortunately, do not represent optimal solutions, either from a technical or economic point of view. These flow-regulating systems are not precise and depend mostly on the pipe roughness, which can vary over time. Also, they depend essentially on high upstream water head to operate. These approaches are at a detrimental loss when regulation of low heads is required. In general, such installation precision can drift of ±15% of the set flow rate over time, due to pipe characteristics variation. The HYDROVEX FluidHook is specially designed for these kinds of applications in CSO s or storm drains, surface pond reservoirs and retention tanks. It is particularly adapted to regulate large or very large flow discharges with small to middle range upstream water heads. Figure 1: The outlet flow of the FluidHook presents a strong jet contraction downstream. Figure on the right hand side shows hydraulic characteristics Q(h). ADVANTAGES The adjustable HYDROVEX FluidHook Flow Control Gate Valve can be manufactured over a wide range of widths. Thus the discharge opening remains very shallow, being able to accept very small upstream water heads, while maintaining a very defined hydraulic regulation characteristic. As a result of this optimized configuration, the FluidHook s geometry presents a particularly strong throttling effect, while maintaining a large free cross-sectional flow. The equipment is completely manufactured from plastic and high-grade steel and presents a high stability. It is very simple in the handling. optimized design for large flow discharge with small upstream head large loss factor creating a strong throttling effect installation upstream from the outlet wall to insure positive water pressure effect precise and direct regulation of the discharge opening set-point metering with a scale and pointer arrangement compact installation no variation of the flow-head relationship over time non-corrosive construction from high-grade steel and HDPE positioning mechanism located above water level accommodates very shallow installations DESIGN & OPERATION The adjustable Flow Control Gate Valve has a lower end forward horizontal bend, directed against the flow. The equipment is adjusted to the opening height "s" supplied by John Meunier Inc. The clear opening becomes a broad but low rectangle. This opening shape is desired: it accepts large water flows even for low upstream heads and can still limit the discharge precisely. In general, market available units present small widths and thus require high opening heights. This leads to flow control effect generated by the building dimensions, rather than the slide gate valve position. In extreme cases, large circular slide gate valves, installed in steep slope areas, would never have the sliding plate in contact with the water at any time.

The regulator uses a special hydraulic effect. Until reaching the gate set-point elevation, the water flows under the gate without interference. If the water level rises to the gate level, then the effluent jet is restricted by the horizontal "J" cut shape of the gate, accelerated strongly and pressed down by the natural restricted water flow pattern. The water throttles itself by generating a strong backflow wave downstream from the unit, while maintaining a relatively large opening height, highly desirable in the sewage engineering, to limit blocking of the opening. With large discharges and small upstream head conditions, the design of the chamber plays a very large role in the efficiency of the installation. An important hydraulic back wave develops in the section of the chamber downstream from the gate valve. This back wave makes the flow control independent from the downstream conditions, until completely submerged conditions appear. If the downstream water conditions lead to a submerged output from the gate valve, the calculation is not independent any longer and needs to include intake losses and energy levels need to be considered. If the regulating chamber is constantly operating in submerged conditions on the downstream side, the hydraulic behavior of the FluidHook regulator is partially impaired. We can evaluate and include this situation in our calculation of the FluidHook. The FluidHook regulator remains partially opened in normal operating conditions. In addition, the unit can be closed for inspection purposes or to build up the upstream wastewater head temporarily. Please note that the closing process of the FluidHook is slow and that the unit can never be closed completely, always leaving wastewater flow underneath, as the unit is not built with a lower seal. Figure 2: with extended thread rod for manual operation Middle view: Standard seat framework to be mounted upstream from a rectangular wall opening. Lower view: Showing the optional hydrodynamic inlet arrangement to optimize the flow. The optional hollow bodies are built of stainless steel sheet metal and are filled with concrete after installation. OPTIONS For standard version "S", the FluidHook is sliding up and down by a threaded rod mechanism located above the water level. The spindle operating square nut is located either on a mounting plate inside the chamber or in a key box located outside the chamber. The slide gate valve position is changed with an operating key handle. If the pit is so low that the installation of a spindle is not possible, then the sliding plate must be moved by hand. This option is called type "SS". When the correct adjustment position is reached, the position is secured by installing a holding block. THROTTLE DISCHARGES In cases where a very important upstream slope is present, the water level may only partially fill the FluidHook for a very long period of time. Under these conditions, the water will simply shoot under the gate, without actually being regulated. Depending on the upstream slope, the FluidHook discharge curve will show a more or less important peak flow (or rinsing point) exceeding the regulated flow of the unit, despite the small opening height of the FluidHook gate valve. For this reason, the upstream slope of the pipes should not be selected at more than 5% gradient. The effect of the peak flow (or rinsing point) is included in our calculation procedure to generate the actual selection.

The is manufactured at any width from 400 mm to 2000 mm. The opening height lies between 400 mm and 800 mm. Larger devices can be manufactured upon request. For selection of the optimal dimensions of the hook gate valve, we use an internal hydraulic calculation procedure. To simplify selection, Table 1 shows typical discharges with an upstream head of 1 m. The calculation is developed in such a way that the smallest discharge Q min presents the flow value for a smaller slide gate valve opening "s" no smaller than 100 mm. In combined or sanitary sewage, the minimum nominal diameter should actually never be below 300 mm. However, in the current case, the opening is not circular but a broad rectangular opening. Under these conditions, openings of 100 mm or more do not present a problem. Width B Discharge with h b - 1m (3.28 ft.) mm (in.) Q min in l/s (cfs) Q min in l/s (cfs) 400 (16") 92 (3.2) 480 (17.0) 600 (24") 138 (4.9) 720 (25.4) 800 (32") 184 (6.5) 960 (33.9) 1000 (40") 230 (8.1) 1200 (42.4) 1200 (48") 276 (9.7) 1440 (50.9) 1400 (56") 322 (11.4) 1680 (59.3) 1600 (64") 368 (13.0) 1920 (67.8) 2000 (80") 460 (16.2) 2400 (84.8) Table 1: Discharge flow with a pressure height of HB = 1.0 m (3.28 ft.) MATERIAL Since all parts of the FluidHook contactor are exposed to strong corrosion attack by wastewater and condensed moisture, special attention to the choice of suitable materials was made. The parts coming directly in contact with the wastewater are manufactured either of HDPE and/or Stainless Steel. All mechanical parts, ex: the spindle, the attachments and the screw connection will be manufactured from high-grade steel or bronze. ASSEMBLY The Flow Control Gate Valve is delivered ready to be installed. The concrete chamber (supplied by others) must include a large rectangular recess so the FluidHook regulator can be installed in it. The mounting wall must be vertical and even. The assembly takes a few hours and requires only normal preparation. The lateral funnels are to be constructed afterwards, according to our data by others. Optionally, we can supply pre-manufactured funnel shapes to be used as lost forms. These parts are simply set up in the building and filled with concrete afterwards. Also the shaping of the slide gate valve seat and outlet evacuation pit is manufactured by others after the assembly. A test run or any further control is not required if the correct slide gate valve position "s" is attested by visual inspection. We guarantee an accuracy of the discharge of ±10%. MAINTENANCE Since the Flow Control Gate Valve is directly in the sewer and exposed to all kinds of refuses, site inspection is to be performed occasionally. The operation screw and spindle is to be checked, greased and tested on a regular basis to insure a smooth operation. Any debris before or after the slide gate valve is to be removed. The correct opening "s" is to be controlled at each visit.

SPECIFICATIONS Adjustable, special gate valve with rectangular flow through open section and horizontal, "J" type bend folded upstream, suitable for wastewater, presenting an optimized geometry for small flow coefficient. The unit is suitable to throttle large discharges with small pressure heads. Suitable for installation in a pre-constructed and prepared rectangular wall opening with continuous, even installation wall. Sliding plate made of 304 stainless steel, lateral guide rails from HDPE. Slide gate valve scale made of highgrade steel. Clevis mounting to and secured to the wall (optional: Key box), drive of the sliding plate with a threaded rod spindle and square nut, all metal parts made of high grade steel or brass. Mounting elements made of 304 stainless steel high-grade steel. with spindle Calculation pressure height h b Calculation discharge Q b Dry weather discharge Clears opening width B Type HS... mws... m Opening of the gate valve "s" to be set according to hydraulic calculation. Equipment supply to be ready for installation, ex: factory including hydraulic calculations and data sheet. Site preparation and installation is by others according to our supplied information. The adjustment within the inlet range is to be made by others afterwards, according to our data. Please refer to the technical specs for all elevation and pressure head values. Adjustable, special gate valve with rectangular flow through open section and horizontal, "J" type bend folded upstream, suitable for wastewater, presenting an optimized geometry for small flow coefficient. The unit is suitable to throttle large discharges with small pressure heads. Suitable for installation in a pre-constructed and prepared rectangular wall opening with continuous, even installation wall. Sliding plate made of 304 stainless steel, lateral guide rails from HDPE. Slide gate valve scale made of highgrade steel. Adjustment blocks from PVC to adjust the sliding plate position. Mounting elements made of 304 stainless steel highgrade steel. with spindle Calculation pressure height h b Calculation discharge Q b Dry weather discharge Clears opening width B Type HSS... mws... m Opening of the gate valve "s" to be set according to hydraulic calculation. Equipment supply to be ready for installation, ex: factory including hydraulic calculations and data sheet. Site preparation and installation is by others according to our supplied information. The adjustment within the inlet range is to be made by others afterwards, according to our data. Please refer to the technical specs for all elevation and pressure head values. hydrodynamic funnel Quarter circle, hollow bodies for the organization of a hydrodynamic clean inlet to the FluidHook Flow Control Gate Valve. To be installed in the building and subsequent filling with concrete. Sheet metal body made of 304 stainless steel. Sheet metal body Width of the hook contactor Installation depth... mm... mm John Meunier Inc. ISO 9001 : 2000 Head Office 4105 Sartelon Saint-Laurent (Quebec) Canada H4S 2B3 Tel.: 514-334-7230 www.johnmeunier.com Fax: 514-334-5070 cso@johnmeunier.com Ontario Office 2000 Argentia Road, Plaza 4, Unit 430 Mississauga (Ontario) Canada L5N 1W1 Tel.: 905-286-4846 www.johnmeunier.com Fax: 905-286-0488 ontario@johnmeunier.com USA Office 2209 Menlo Avenue Glenside, PA USA 19038 Tel.: 412-417-6614 www.johnmeunier.com Fax: 215-885-4741 asteele@johnmeunier.com Revised : 2008-10-01