COOLEDGE LINE INSTALLATION INSTRUCTIONS

Similar documents
E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - RECESSED MOUNT

The entire TILE Exterior system including light sheets, connectors, cables, and LED power supplies is rated for wet location

COOLEDGE LUMINOUS CEILINGS FABRICATED LUMINAIRE - SUSPENDED

LumaFilm Light Emitter Installation Instructions

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

1 TILE Interior SPECIFICATION

COOLEDGE TILE INTERIOR - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

COOLEDGE TILE EXTERIOR - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

INSTALLATION INSTRUCTIONS

LED STRIP LIGHTING KIT EUKT04 WW30

LED Downlight Ceiling Fixtures

CFP-LED Contractor Select Flat Panel. Installation Instructions

B-RAD Select USER MANUAL TABLE OF CONTENTS

VITALink Taped Splice Pigtail Crimp

Removable Applied Panel Mounting System

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

General Installation Instructions LED

Power Connection Kit installation instructions

USB Charge Port Installation Instructions

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Professional Solar only

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

INSTALLATION. led fairing lights for gl

INSTALLATION INSTRUCTIONS

Technical Installation Manual

Sky FactoryTM. Classic w/ EcoSlim Electrical Instructions (HLG) Installation Instruction includes:

EXT DUCTLESS FUME HOOD

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION & OPERATION MANUAL

For Professional Solar only

Installation Instructions: ACCENT SYSTEM

For BLOWER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions

For AEE SnapNRack Only Please read carefully before installing.

Manual Transfer Switch

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

VEI Systems Installation Instructions OGDI-aaa-bbb-c Dual Gauge Module for Custom Installations Wiring Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

BP1204 INSTALLATION/OWNER'S MANUAL

channel damage the internal components and the weight may break the internal wiring or flexible strip.

4 Installation Guidelines

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Saf-T-Bar Conductor Bar T Series

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

VHX-69C-CAM Dakota Digital VHX Instrument Installation For 69 Chevy Camaro systems

EXT HEPA/CARBON FUME HOOD

24 Volt Eco Flex LED Neon Part Numbers: LFN-2700K, LFN-5800K

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

INSTALLATION GUIDE PRISONER TRANSPORT LIGHTING. pro-gard.com STRONG RELIABLE SECURE

Safety, Installation and Service Manual Models 1952, 1953 & 1972

SloanLED THINLED. Constant Current. Installation Guide

Conductive Fabric Over Foam Gaskets

ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS BEFORE ASSEMBLING, INSTALLING OR USING THIS PRODUCT.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Turbo-House Air Inlet Installation & Operator s Instruction Manual

Combine Cover Manual

INSTALLATION INSTRUCTIONS

Utility Controller Hand Air Operated

Roush Side Rocker Panel Splitters (10-13 All)

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

C Power Connection Kit

LoadMaxx. Installation Guide. For Air Ride Trailers. Air-Weigh Customer Support: PN R0

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Door Restrictor Assembly. Model R2

INSTALLATION/OWNERS MANUAL

Kompensator External Low Voltage Heating Cable System

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

Lumination TM LED Luminaires LAL Series - Continuous Run Option

10W LED Die Cast Small Rectangle Bulkhead Light

LED IMPORTANT SAFETY INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

EUROPLEX SDX EUROPLEX SDX-F. Danger averted! Static dissipative ESD glazing made of polycarbonate

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Service Note. Installing/Replacing Antistatic tape on SPINJET 4000 January Static Charge. Humidity. Grounding. Earthed mains outlet

Flex Tube. User guide

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Derailment Detector Assembly

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Transcription:

5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE LINE INSTALLATION INSTRUCTIONS Please read these instructions PRIOR to installation. Installation must be completed by a qualified electrician in accordance with all national and local electrical and construction codes.! Ensure the following steps are completed prior to connecting power to the system. 1.0 IMPORTANT NOTES Cooledge LINE products are rated for dry locations ONLY. Cooledge LINE light sheets must be powered by a Cooledge approved constant voltage LED Driver that has been certified for use in your region. If used with a non-approved power source, the warranty will be voided. 2.0 CARE & HANDLING GUIDELINES Handle light sheets by the borders running the length of the sheet on both sides. Avoid handling, scraping, rubbing, or wiping the active area of the sheet between the borders. LEDs and drive components are bonded to the plastic base material, but it is possible to remove or damage the electrical connection if not handled with care. Avoid penetrating the active area of the sheet for any reason. Mounting holes for fasteners may be located in the border areas along the length of the sheets. As with all electronics, LINE is susceptible to damage from Electrostatic Discharge (ESD). Where possible avoid situations that are conducive to creating static. Avoid creasing or repeated flexing of the light sheets as this may cause separation in the traces of the (safe low voltage DC) electrical circuits located on the sheet surface. Do not install light sheet in a curve with a bend radius of < 2 (50mm). EN 60598 Compliant (as a system) In Canada, LINE must be installed within an enclosure 5 5 Year Limited Warranty: Parts and workmanship Cooledge Lighting Inc. 110-13551 Commerce Parkway Richmond, BC V6V 2L1 Canada O +1 604 273 2665 F +1 604 273 2660 T +1 844 455 4448 W cooledgelighting.com Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company s continuing product improvement program. EXT-0019-R07-061118 (LTR) 1/7

3.0 COOLEDGE LINE SYSTEM CONTENTS One or more LINE sheets with a Molex connector attached to the red/black conductors at the input end of each sheet. One 2-conductor Starter Cable per LINE sheet with a matching Molex connector on one end and bare leads on the other for connection to the LED driver or an Extension Cable. One LED driver certified for use in your region (includes enclosure in N. America) 2 conductor Extension Cable (Optional) Multiple LINE Sheets wired to LED Driver Molex Mini-fit Jr. Connector Driver* Crimp Connector ~ Extension Cable *Driver in enclosure for N. America Starter Cable LINE 4.0 LINE INSTALLATION OVERVIEW 1. Plan your layout or refer to the project drawings and locate the LINE sheets that correspond to the layout. 2. Starting at the input end (the end with the wires and connector) place the LINE in the correct install location. Pull the LINE taught to lie flat on the mounting surface. 3. At the opposite end, determine the amount of material that needs to be cut off (if any). 4. Cut the LINE to length at the appropriate cut point (cut increment). 5. Using mechanical fasteners or double-sided foam tape, attach the LINE to the mounting surface ensuring that it lies flat. 6. At the input end, connect the Starter Cable to the LINE using the white plug connector. This cable will connect to the LED driver or, where many LINE sheets are connected to a single driver, to an Extension Cable. 7. Once the driver is connected to the main power, the installation is complete. EXT-0019-R07-061118 (LTR) 2/7

5.0 LINE INSTALLATION: DETAILS LINE products are designed to mount directly to most common NON-CONDUCTIVE building materials. The choice of using fasteners or adhesive tape should be appropriate for the mounting surface. A. CUTTING 1. LINE products are shipped in standard lengths and may require cutting to a shorter length on-site. 2. LINE sheets may be cut with scissors, shears, and a knife at specific length increments that are unique to each type. 3. Material that is cut from the end of the LINE sheet not connected to the input wires cannot be used and should be discarded. B. MOUNTING LINE may be mounted using double-sided tape, mechanical fasteners, or a combination of both. MECHANICAL FASTENERS 1. Fasteners should be appropriate for the mounting surface. 2. The transparent border of the LINE sheet (identified as the tape region) can be punched at periodic intervals and the sheet attached with mechanical fasteners (e.g. screws, rivets). Ensure that all fasteners are located outside of the active area of the LINE sheet and at least 0.2 (5mm) away from any component. 3. A nylon washer should be used in conjunction with the fastener to allow for expansion/ contraction of the plastic material with relation to the mounting surface and prevent electrical contact with the active area of the light sheet. TAPE 1. Cooledge recommends using a foam type (e.g. 3M VHB or similar) to allow some expansion/ contraction. 2. Adhesive tape must not be applied within 0.5 () distance from a sheet splicing location, which occurs at the intersection of 2 adjacent sheets. 3. It is recommended to only apply tape along the borders of each sheet. EXT-0019-R07-061118 (LTR) 3/7

6.0 LINE - 2.2 (56MM) WIDTH: CUTTING & MOUNTING Cutting: LINE 450 sheets may be cut every 72mm (2.8 ) with scissors, shears, or a knife. Cut possible every 72mm (2.8 ) ONLY at existing marked locations Wire 56mm (2.2 ) Cut -line marking Mounting: Ensure fasteners are located outside the active area and at least 5mm (0.2 ) away from any component. No tape and no fasteners mounted here 36mm (1.4 ) Active area Fastener mount location Splice location EXT-0019-R07-061118 (LTR) 4/7

7.0 LINE - 3.8 (96MM) WIDTH: CUTTING & MOUNTING Cutting: LINE-850 sheets may be cut every 14mm (0.6 ) with scissors, shears, or a knife. Cut on clear plastic along rows with no white ink Cut possible every 14mm (0.6 ) Wire 96mm (3.8 ) Mounting: Ensure fasteners are located outside the active area and at least 5mm (0.2 ) away from any component. No tape and no fasteners mounted here 70mm (2.8 ) Active area Splice location EXT-0019-R07-061118 (LTR) 5/7

8.0 INSTALLING & CONNECTING THE LED DRIVER! WARNING - Risk of Fire. Do not install insulation within 3 (75mm) of the surface of the LED driver (or UL Listed enclosure). Access above ceiling or behind wall required.! DO NOT connect AC power to the LED driver until all wiring has been completed and checked. GREY VIOLET Cooledge LINE DIMMER OPTIONAL - BY OTHERS LINE NEUTRAL EARTH BLACK WHITE GREEN/YELLOW DRIVER VIOLET GREY RED BLACK EXTENSION CABLE STARTER CABLE ELECTRICAL ENCLOSURE WIRE NUT IF REQUIRED CRIMP CONNECTOR Refer to the wiring diagram above: 1. Mount the LED driver (or enclosure) to the mounting surface using appropriate fasteners. 2. Connect the Start Cable or Extension Cable to the low voltage DC connections on the LED driver. 3. Connect the 0/1-10V dimmer (if required) to the LED drivers. 4. Connect the Extension Cable (if required) to the Starter Cable(s) using a crimp connector. 5. Connect the Starter Cable to the LINE sheet using the wire plug connector. 6. Check that all connections have been made correctly* 7. Connect the AC mains (line) voltage according to the requirements of all applicable electrical codes. *WARNING - Connecting the low voltage DC connections incorrectly will cause damages to the LINE sheet(s). EXT-0019-R07-061118 (LTR) 6/7

5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY 9.0 TROUBLESHOOTING If the LINE does not illuminate when power is applied Check to ensure all electrical connections have been made. Check to ensure that the low voltage wires have been correctly matched. If one (1) section of LEDs on a sheet does not illuminate The circuit for those LEDs has likely been damaged and the LINE sheet should be replaced. If a single LED on a LINE sheet does not illuminate The connection between the LED and the circuit on the Cooledge LINE has likely been short circuited. The overall light output of the system will not be affected and if the LINE sheet is mounted so that the LEDs are not visible, there should not be a need to replace the sheet. If the LEDs are intended to be visible, a replacement LINE sheet may be required. 10.0 PRODUCT SUPPORT Contact Cooledge Technical Support at: E: apps.engineering@cooledgelighting.com O: +1.604.273.2665 T: 1.844.455.4448 (toll free North America) 11.0 WARRANTY Cooledge warrants that the products manufactured, distributed or sold by it will: 1. Be free of any claim of ownership by third parties 2. Be conforming to the Specifications and free from defects in materials and workmanship under normal use, handling, warehousing and service. The warranty period specified in the Cooledge Warranty Terms and Conditions for the products will be for a period of five (5) years from the shipment date of any products sold by Cooledge. EN 60598 Compliant (as a system) In Canada, LINE must be installed within an enclosure 5 5 Year Limited Warranty: Parts and workmanship Cooledge Lighting Inc. 110-13551 Commerce Parkway Richmond, BC V6V 2L1 Canada O +1 604 273 2665 F +1 604 273 2660 T +1 844 455 4448 W cooledgelighting.com Cooledge Lighting reserves the right to change materials or modify the design of its product without notification as part of the company s continuing product improvement program. EXT-0019-R07-061118 (LTR) 7/7