circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TeChniCAl DATA

Similar documents
circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications TECHNICAL DATA

circuit breakers circuit breakers Thermal Circuit Breaker, rocker actuated, 1-, 2- or 3-pole Description Applications

circuit breakers circuit breakers Thermal Circuit Breaker, rotary knob actuation, 1-, 2- or 3-pole Description Applications

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3130

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal-Magnetic Circuit Breaker M1-..

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Circuit Breaker / Switch Series 3131

Thermal Circuit Breaker / Switch Series 3131

N W. Thermal Circuit Breaker / Switch Series Description. Typical applications Circuit breaker. Technical data

CIRCUIT BREAKERS FOR EQUIPMENT, 2 POLE, PUSH BUTTON

Thermal Circuit Breaker / Switch Series 3131

SERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES

Magnetic and Hydraulic-Magnetic Circuit Breaker

TMC 91H is now TMC 60 C Series

Electronic circuit breaker EBU10-T

High Performance Thermal Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker

Selection Guide. Control Circuit and Load Protection

max pole for t=15 ms

PD-Series Ground Fault Circuit Protection

Magnetic and Hydraulic-Magnetic Circuit Breaker

Electronic Circuit Breaker ESS20

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

G-Series. Circuit Breaker.

Electronic Circuit Breaker ESS20-0..

Thermal-Magnetic Circuit Breaker 201/-WA

Magnetic Overcurrent Circuit Breaker

Thermal-magnetic Miniature Circuit Breaker 4230-T...

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Technical Information

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

Control Circuit Protection

LUMOTAST 25 selector switch 1-28 LUMOTAST 25 selector switch, Click quick-assembly feature 1-29 LUMOTAST 25 selector switch, ring nut fixing 1-29

Products :: Circuit Protection :: Thermal Circuit Breakers

Control & Signalling Devices 22.5 mm. RoHS. Compliant

High Performance Thermal-Magnetic Circuit Breakers 410/520/

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

UMBW-UL489 and UL1077 Listed

EMO-21. Specifications. Elcom International Pvt. Ltd. Approvals: Screw mounting IEC outlet. Terminals: 6.3 mm Quick Disconnect Tabs.

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Protection components

ID ID. Series 19. Mechanical Products Company

Ordering Information. Text PCB Power Relay G5LE

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

3 - Protection components Motor circuit-breakers

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Thermal-magnetic Miniature Circuit Breaker 4230-T...

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

2600 SERIES ILLUMINATED AND NON-ILLUMINATED ROCKER SWITCHES Overview

3VU13, 3VU16 Circuit-Breakers

Bulletin 193-T1 Bimetallic Overload Relays

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Manual Motor Starters. Meta-MEC

PB-Series. GFCI/ELCI & Panel Seal

10 Load and Motor Switchgear

LK Position Switches TECHNICAL DATASHEET.

PowerLine OS Switch Fuses A, 690V

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Circuit Breakers. DIN rail-mounted equipment protection

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

General_technical_data Series

DPX 1600 Electronic release

Load and Motor Switches, Load-Break Switches Series 8549

MS-Series. Circuit Breaker

PDR circuit breaker - Ground fault Datasheet

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

RoHS. Specifications. Part Number Configurator

Phase + Neutral, neutral on right side

Series L9 UL489 Miniature Circuit Breakers

LUMOTAST FK. General data. Content

LR9 F OVERLOAD RELAYS

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

G-Series DIN-RAIL CIRCUIT BREAKER

Simulator switch, magnetic operation

BETA Switching Switches and Light Indicators

XT IEC Power Control Manual Motor Protectors

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Multi-Pak Group Control

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

1489-M Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers

SIRIUS 3RU2 Thermal Overload Relays

SMD High Power Precision Resistors

Thermal overload relays Type TA Class 10

Transcription:

Thermal Circuit Breaker, rocker actuated, -, 2- or -pole TA -pole TA 2-pole TA -pole Description Thermal circuit breaker -, 2- or -pole Supplementary protector for general industrial use Positively trip-free release Snap-in mounting Version with illuminated rocker Different rocker colours Protection cover for IP6 Standards IEC 69 UL CSA C22.2 2 GB Applications Power tools Industrial equipment Equipment for building construction Medical equipment Cleaning equipment Power generators Commercial and household kitchen appliances Weblinks Approvals: http://www.schurter.com/approvals RoHS: http://www.schurter.com/rohs TeChniCAl DATA Rated voltage U e -pole AC 2 V//6 Hz DC 2 V 2-pole AC 2 V//6 Hz DC 6 V -pole AC Y/2 V//6 Hz Rated current - /2-pole. 2A -pole. 2A Conditional short - / 2-pole, AC 2 V. 2 A: A, SC (C) circuit c -pole, AC V. 2 A: A Degree of protection Accessible range IP Terminal side IP Dielectric strength AC 2 V/Hz V Impulse 2 V Insulation resistance DC V > MOhm Overload IEC 69 min. cycles @6x, cos phi.6 UL min. cycles @. x, cos phi. (OLØ) Admissible ambient C to + C air temperature Resistance to vibration IEC 668-2-6, Test Tc 6 Hz: ±. mm 6 Hz: G Shock resistance Type of tripping IEC 668-2-2, Test Ea G/8ms Weight -pole 9 g 2-pole 2 g -pole g Thermal positivelytrip free Endurance (typical) Mechanical cycles AC: x,cos phi.6 cycles DC: x,l/r =2 ms cycles 2

www.schurter.com/pg_8_9 TA Tripping ChArACTeriSTiCS [min ] [sec ] ' 6 2` 2 ` Type p TA Rated current <A(TC), 2pole Ambient temp. pole +2 C [min ] [sec ] ' 6 2` 2 ` Type Rated current Ambient temp. TA 2A (TC) ( pole max. 2A),2, pole +2 C 2 2 2 2 2 2,, Tripping time,,2,,, 2 8 Tripping time,,2,,, 2 8 Multiple of rated current [x In ] Multiple of rated current [x In ] The above tripping characteristics apply to symmetrical overloads on all poles on the TA only. At asymmetric overloads on multi-pole types, the tripping characteristic will change. Ifa2-pole type TA is loaded at one pole only, the tripping current will be shifted by factor.. Ifa-pole type TA is loaded at one pole only, the tripping current will be shifted by factor.. To meet the above tripping characteristic at asymmetric overloads on multi-pole types, the value of the rated current of the CBE has to be multiplied by the factor mentioned above. effect of ambient temperature The unit is calibrated for an ambient temperature of +2 C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. Ambient temperature [ C] Correction factor.8.89.9 +2. +. +. +.22 example: Rated current at +2 C. A Ambient temperature + C Correction factor. Chosen rated current at + C ambient temperature: Ax. =. A

Standard rated currents and typical internal resistance In Ri [Ohm] J.. J. 2. J..2 J.. J2 2..9 J2 2.. J28 2.8.9..8....28 6 6..2..6 8 8.... 2 2..68..2..8 6 6..8 8 8..8 2 2..8 unprotected poles (without bimetal).22 ApprovAlS #ofpoles Rated currents Rated voltage AC Rated voltage DC UL UL *. 2 A 2 V 2V 2. 2 A 2 V 6V. 2 A Y/2 V UL CSA C22.2 2 *. 2 A 2 V 2V 2. 2 A 2 V 6V. 2 A Y/2 V VDE IEC 69 *. 2 A 2 V 2V 2. 2 A 2 V 6V. 2 A Y/2 V CQC GB *. 2 A 2 V 2V 2*. 2 A 2 V 6V *. 2 A Y/2 V * Approvals pending Actual information about approvals can be found on: www.schurter.com/approvals.

l www.schurter.com/pg_8_9 TA rocker legend Surface illustration Colour of print F embossed h printed white l l order CoDe -pole 2-pole -pole P P 8 8 8 9 6 Switch without CFC CFT CBC CBT CBD CKC CKD Illumination Switch illuminated V CK CD 2 V CF2 C2F C2 C2 C2 2 V CF CF C C C 2 V CF CF C C C 2 V CF8 C8F C8 C8 C8 V CF9 C9F C9 C9 C9 Momentary without CgC CgT CeC CeT CeD ClC ClD switch illumination Other versions on request TA- CBD W F 2 C No other features Colours Switch front rocker W black white B black black r black red g black green Y black yellow X black orange black clear transparent black red transparent black green transparent 6 black orange transparent black blue transparent Other colours on request ON K printed black ON OFF OFF l printed white M printed black Other legends on request Without thermal overload protection: code C With thermal overload protection: rated current i n (A), J,2 J2, J, J, J,8 J8, J Other rated currents on request,2 J2, J 2, J2 2, J2,,,, 6, 6, 8, 8, 2, 2,, 6, 6 8, 8 2, 2

DiMenSionS TA -pole 6. 9.9. +.2.8.2 L LINE.. Label. +.2 IEC 62 A2.8-. (illuminated version only) 2..8 2. 2...6 Panel thickness.. mm IEC 62 A6.-.8 TA 2-pole 6 29 2.9 26 +.2..2 L LINE.. Label..6 +.2 2. 2. 6. Panel thickness.. mm.8 2. IEC 62 A6.-.8 26 TA -pole 6..9. +.2..2 L LINE.. Label..6 +.2 2..8 2. 6.. Panel thickness.. mm IEC 62 A6.-.8. 6

www.schurter.com/pg_8_9 TA ACCeSSorieS Cover /collar for protection ip 6 CZZ (-pole). +.2 2. 9.8 2 2..8. 9. 2.8 ±. CZZ2 (2-pole). 9.8 2 2.6. 9. 2.8 ±. CZZ (-pole) 2. 9.8 9. 2 6. 6. 2. +.2 ±. 26 +.2 +.2 2. ±. 8. 8 ±. +.2. +.2 2. 2.8 ±.